{"id":6949,"date":"2025-07-15T11:15:20","date_gmt":"2025-07-15T03:15:20","guid":{"rendered":"https:\/\/www.qualitester.com\/?p=6949"},"modified":"2025-07-28T17:32:59","modified_gmt":"2025-07-28T09:32:59","slug":"film-free-shrink-tester","status":"publish","type":"post","link":"https:\/\/www.qualitester.com\/tr\/film-free-shrink-tester\/","title":{"rendered":"Filmsiz Shrink Test Cihaz\u0131"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6949\" class=\"elementor elementor-6949\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c2bf01 e-flex e-con-boxed e-con e-parent\" data-id=\"5c2bf01\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-643f1c8 elementor-widget elementor-widget-text-editor\" data-id=\"643f1c8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Film shrinkage is a key performance parameter in the flexible packaging industry, directly affecting the appearance, integrity, and application reliability of finished products. A <strong data-start=\"737\" data-end=\"764\">film free shrink tester<\/strong> is the preferred tool for evaluating this behavior under controlled thermal exposure. By simulating real-world heat conditions and quantifying unrestrained shrinkage, quality teams can optimize processing conditions and ensure batch consistency. This article discusses how the film free shrink test works, introduces the <strong data-start=\"1086\" data-end=\"1100\">ASTM D2732<\/strong> testing standard, and recommends how to implement it effectively using Cell Instruments&#8217; <strong data-start=\"1190\" data-end=\"1224\">FST-01 Filmsiz Shrink Test Cihaz\u0131<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bfad030 e-flex e-con-boxed e-con e-parent\" data-id=\"bfad030\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7812c74 elementor-widget elementor-widget-heading\" data-id=\"7812c74\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Understanding Film Shrinkage and Its Importance<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-137c9ba e-flex e-con-boxed e-con e-parent\" data-id=\"137c9ba\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-506aa47 elementor-widget elementor-widget-text-editor\" data-id=\"506aa47\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1285\" data-end=\"1644\">Films made from polymers like <strong data-start=\"1315\" data-end=\"1335\">PET, PVC, and PE<\/strong> are widely used in packaging, medical wrapping, electrical insulation, and industrial bundling. These films often require <strong data-start=\"1458\" data-end=\"1482\">controlled shrinkage<\/strong> when exposed to heat, enabling a tight seal or fit. Inconsistent shrinkage can lead to poor sealing, wrinkling, product damage, or failed regulatory inspections.<\/p><p data-start=\"1646\" data-end=\"1916\">To avoid these issues, manufacturers test shrink properties using a <strong data-start=\"1714\" data-end=\"1741\">film free shrink tester<\/strong>. Unlike constrained methods, the free shrink test evaluates the material\u2019s natural, unrestrained dimensional change under heat\u2014closely reflecting real application conditions.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b2d5abe e-flex e-con-boxed e-con e-parent\" data-id=\"b2d5abe\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bb644ab elementor-widget elementor-widget-heading\" data-id=\"bb644ab\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ASTM D2732: The Standard for Thermal Shrinkage Testing<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-49c8448 e-flex e-con-boxed e-con e-parent\" data-id=\"49c8448\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5958b75 elementor-widget elementor-widget-text-editor\" data-id=\"5958b75\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1983\" data-end=\"2159\">Bu <strong data-start=\"1987\" data-end=\"2001\">ASTM D2732<\/strong> standard specifies a reliable method for determining the free shrinkage of plastic films when subjected to elevated temperatures. It outlines procedures for:<\/p><ul data-start=\"2161\" data-end=\"2281\"><li data-start=\"2161\" data-end=\"2189\"><p data-start=\"2163\" data-end=\"2189\"><strong data-start=\"2163\" data-end=\"2187\">Specimen preparation<\/strong><\/p><\/li><li data-start=\"2190\" data-end=\"2237\"><p data-start=\"2192\" data-end=\"2237\"><strong data-start=\"2192\" data-end=\"2235\">Thermal exposure using liquid immersion<\/strong><\/p><\/li><li data-start=\"2238\" data-end=\"2281\"><p data-start=\"2240\" data-end=\"2281\"><strong data-start=\"2240\" data-end=\"2281\">Post-exposure dimensional measurement<\/strong><\/p><\/li><\/ul><p data-start=\"2283\" data-end=\"2552\">During the test, a film specimen is immersed into a controlled-temperature fluid bath for a set duration. The changes in length along the <strong data-start=\"2421\" data-end=\"2447\">makine y\u00f6n\u00fc (MD)<\/strong> ve <strong data-start=\"2452\" data-end=\"2481\">enine y\u00f6n (TD)<\/strong> are measured and recorded to calculate the <strong data-start=\"2525\" data-end=\"2551\">thermal shrinkage rate<\/strong>.<\/p><blockquote data-start=\"2576\" data-end=\"2656\"><p data-start=\"2578\" data-end=\"2656\"><strong data-start=\"2578\" data-end=\"2656\">Shrinkage (%) = [(Original Length \u2013 Final Length) \/ Original Length] \u00d7 100<\/strong><\/p><\/blockquote><p data-start=\"2658\" data-end=\"2787\">Following <strong data-start=\"2668\" data-end=\"2682\">ASTM D2732<\/strong> ensures test repeatability and allows results to be compared across production runs, labs, or suppliers.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0455ee2 e-flex e-con-boxed e-con e-parent\" data-id=\"0455ee2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-baf9e1c elementor-widget elementor-widget-heading\" data-id=\"baf9e1c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How a Film Free Shrink Tester Works<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc6d69d e-flex e-con-boxed e-con e-parent\" data-id=\"dc6d69d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4a813cb elementor-widget elementor-widget-text-editor\" data-id=\"4a813cb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>A <strong data-start=\"2837\" data-end=\"2864\">film free shrink tester<\/strong> like Cell Instruments&#8217;<a href=\"https:\/\/www.qualitester.com\/tr\/urun\/film-free-shrink-tester-fst-01\/\" target=\"_blank\" rel=\"noopener\"> <strong data-start=\"2888\" data-end=\"2898\">FST-01<\/strong><\/a> is designed to simulate uniform thermal exposure in a lab environment. Here&#8217;s how the process works:<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9806104 e-flex e-con-boxed e-con e-parent\" data-id=\"9806104\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6c0c88b e-con-full e-flex e-con e-child\" data-id=\"6c0c88b\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ee09ada elementor-widget elementor-widget-text-editor\" data-id=\"ee09ada\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul><li data-start=\"3001\" data-end=\"3143\"><p data-start=\"3004\" data-end=\"3143\"><strong data-start=\"3004\" data-end=\"3022\">Specimen Setup<\/strong>:<br data-start=\"3023\" data-end=\"3026\" \/>Cut the film sample to standard size (\u2264160 mm \u00d7 160 mm). Mark both MD and TD lines to assist accurate measurement.<\/p><\/li><li data-start=\"3145\" data-end=\"3329\"><p data-start=\"3148\" data-end=\"3329\"><strong data-start=\"3148\" data-end=\"3167\">Heating Process<\/strong>:<br data-start=\"3168\" data-end=\"3171\" \/>The film is quickly immersed into a <strong data-start=\"3210\" data-end=\"3252\">thermostatically controlled fluid bath<\/strong>. The temperature can be adjusted from ambient to 200\u00b0C with \u00b10.3\u00b0C accuracy.<\/p><\/li><li data-start=\"3331\" data-end=\"3565\"><p data-start=\"3334\" data-end=\"3565\"><strong data-start=\"3334\" data-end=\"3356\">Shrink Measurement<\/strong>:<br data-start=\"3357\" data-end=\"3360\" \/>After removing the film, it is laid flat and the lengths along both MD and TD are measured using a high-precision ruler or tool (\u00b11 mm). These values are used to calculate <strong data-start=\"3535\" data-end=\"3564\">free shrinkage percentage<\/strong>.<\/p><\/li><li data-start=\"3331\" data-end=\"3565\"><p data-start=\"3567\" data-end=\"3817\">The FST-01 tester ensures <strong data-start=\"3593\" data-end=\"3622\">uniform heat distribution<\/strong>, <strong data-start=\"3624\" data-end=\"3656\">accurate temperature control<\/strong>, ve <strong data-start=\"3662\" data-end=\"3692\">repeatable test conditions<\/strong>, enabling professionals to determine how a film will behave in actual applications such as shrink sleeves, lids, or bundles.<\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b086628 e-con-full e-flex e-con e-child\" data-id=\"b086628\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-4029173 e-con-full e-flex e-con e-child\" data-id=\"4029173\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-34ab7ae elementor-widget elementor-widget-image\" data-id=\"34ab7ae\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-02-2_11zon-1-300x300.webp\" class=\"attachment-medium size-medium wp-image-6955\" alt=\"A film free shrink tester is essential for any manufacturer working with heat-shrinkable films. When combined with the ASTM D2732 standard\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-02-2_11zon-1-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-02-2_11zon-1-1024x1024.webp 1024w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-02-2_11zon-1-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-02-2_11zon-1-768x768.webp 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-02-2_11zon-1-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-02-2_11zon-1-600x600.webp 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-02-2_11zon-1-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-02-2_11zon-1.webp 1080w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-01c2c1e e-con-full e-flex e-con e-child\" data-id=\"01c2c1e\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-16904d8 elementor-widget elementor-widget-image\" data-id=\"16904d8\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-021_11zon-300x300.webp\" class=\"attachment-medium size-medium wp-image-6956\" alt=\"A film free shrink tester is essential for any manufacturer working with heat-shrinkable films. When combined with the ASTM D2732 standard\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-021_11zon-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-021_11zon-1024x1024.webp 1024w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-021_11zon-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-021_11zon-768x768.webp 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-021_11zon-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-021_11zon-600x600.webp 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-021_11zon-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/1.FST-01-Film-Free-Shrink-Tester-ASTM-D2732-021_11zon.webp 1080w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f0b9f29 e-flex e-con-boxed e-con e-parent\" data-id=\"f0b9f29\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-479a54b elementor-widget elementor-widget-heading\" data-id=\"479a54b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why Choose the FST-01 Film Free Shrink Tester from Cell Instruments?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4824abf e-flex e-con-boxed e-con e-parent\" data-id=\"4824abf\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a679f0 elementor-widget elementor-widget-text-editor\" data-id=\"8a679f0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3898\" data-end=\"4045\">For packaging manufacturers and converters looking to maintain high standards, the <strong data-start=\"3981\" data-end=\"4015\">FST-01 Filmsiz Shrink Test Cihaz\u0131<\/strong> provides a powerful solution:<\/p><ul data-start=\"4047\" data-end=\"4479\"><li data-start=\"4047\" data-end=\"4131\"><p data-start=\"4049\" data-end=\"4131\"><strong data-start=\"4049\" data-end=\"4074\">Real-world simulation<\/strong> of heat-induced shrink behavior using fluid immersion.<\/p><\/li><li data-start=\"4132\" data-end=\"4222\"><p data-start=\"4134\" data-end=\"4222\"><strong data-start=\"4134\" data-end=\"4160\">High temperature range<\/strong> (Ambient ~ 200\u00b0C) suitable for a variety of film materials.<\/p><\/li><li data-start=\"4223\" data-end=\"4292\"><p data-start=\"4225\" data-end=\"4292\"><strong data-start=\"4225\" data-end=\"4246\">Precision control<\/strong> with \u00b10.3\u00b0C accuracy for batch consistency.<\/p><\/li><li data-start=\"4293\" data-end=\"4362\"><p data-start=\"4295\" data-end=\"4362\"><strong data-start=\"4295\" data-end=\"4311\">Compact size<\/strong> (37 \u00d7 44 \u00d7 28 cm) fits in most labs or QC areas.<\/p><\/li><li data-start=\"4363\" data-end=\"4479\"><p data-start=\"4365\" data-end=\"4479\"><strong data-start=\"4365\" data-end=\"4417\">Ideal for PET, PVC, PE, and laminated structures<\/strong>, as well as medical wraps and heat-shrink insulation sleeves.<\/p><\/li><li data-start=\"4363\" data-end=\"4479\">Integrating FST-01 into your testing workflow helps prevent production issues, meet client specs, and maintain competitive product quality.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f3c7aa6 e-flex e-con-boxed e-con e-parent\" data-id=\"f3c7aa6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9bf945c elementor-widget elementor-widget-heading\" data-id=\"9bf945c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Sonu\u00e7<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f057c89 e-flex e-con-boxed e-con e-parent\" data-id=\"f057c89\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a6464ed elementor-widget elementor-widget-text-editor\" data-id=\"a6464ed\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>A <strong data-start=\"4645\" data-end=\"4672\">film free shrink tester<\/strong> is essential for any manufacturer working with heat-shrinkable films. When combined with the<a href=\"https:\/\/www.qualitester.com\/tr\/urun-kategori\/astm\/astm-d2732\/\" target=\"_blank\" rel=\"noopener\"> <strong data-start=\"4766\" data-end=\"4780\">ASTM D2732<\/strong><\/a> standard, it provides actionable data to refine materials and processes, ensuring product reliability and appearance. <strong data-start=\"4899\" data-end=\"4927\"><a href=\"https:\/\/www.celtec.cn\" target=\"_blank\" rel=\"noopener nofollow\">H\u00fccre Enstr\u00fcmanlar\u0131<\/a>&#8216; FST-01<\/strong> offers an advanced, reliable platform to perform these tests with precision and ease.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d4c3a77 e-flex e-con-boxed e-con e-parent\" data-id=\"d4c3a77\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-42ff441 e-con-full e-flex e-con e-child\" data-id=\"42ff441\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c29a6f2 elementor-widget elementor-widget-video\" data-id=\"c29a6f2\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=loAtWddAIfc&quot;,&quot;mute&quot;:&quot;yes&quot;,&quot;loop&quot;:&quot;yes&quot;,&quot;modestbranding&quot;:&quot;yes&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-862b262 e-con-full e-flex e-con e-child\" data-id=\"862b262\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a0e77f elementor-widget elementor-widget-text-editor\" data-id=\"3a0e77f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"5015\" data-end=\"5232\">Whether you are in <strong data-start=\"5034\" data-end=\"5108\">packaging, pharmaceuticals, electronics, or industrial film production<\/strong>, implementing free shrink testing can dramatically improve quality control and reduce failure rates on the production line.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Film b\u00fcz\u00fclmesi, esnek ambalaj end\u00fcstrisinde bitmi\u015f \u00fcr\u00fcnlerin g\u00f6r\u00fcn\u00fcm\u00fcn\u00fc, b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc ve uygulama g\u00fcvenilirli\u011fini do\u011frudan etkileyen \u00f6nemli bir performans parametresidir. Filmsiz b\u00fcz\u00fclme test cihaz\u0131, kontroll\u00fc termal maruziyet alt\u0131nda bu davran\u0131\u015f\u0131 de\u011ferlendirmek i\u00e7in tercih edilen bir ara\u00e7t\u0131r. Kalite ekipleri, ger\u00e7ek d\u00fcnyadaki \u0131s\u0131 ko\u015fullar\u0131n\u0131 sim\u00fcle ederek ve s\u0131n\u0131rland\u0131r\u0131lmam\u0131\u015f b\u00fcz\u00fclmeyi \u00f6l\u00e7erek i\u015fleme ko\u015fullar\u0131n\u0131 optimize edebilir ...<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/tr\/film-free-shrink-tester\/\"> <span class=\"screen-reader-text\">Filmsiz Shrink Test Cihaz\u0131<\/span> Devam\u0131 \"<\/a><\/p>","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-6949","post","type-post","status-publish","format-standard","hentry","category-test-method"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/posts\/6949","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/comments?post=6949"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/posts\/6949\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/media?parent=6949"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/categories?post=6949"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/tags?post=6949"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}