{"id":6847,"date":"2025-07-16T15:26:51","date_gmt":"2025-07-16T07:26:51","guid":{"rendered":"https:\/\/www.qualitester.com\/?p=6847"},"modified":"2025-07-28T17:31:08","modified_gmt":"2025-07-28T09:31:08","slug":"short-span-compression-testing-for-paper","status":"publish","type":"post","link":"https:\/\/www.qualitester.com\/tr\/short-span-compression-testing-for-paper\/","title":{"rendered":"Short Span Compression Testing for Paper"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6847\" class=\"elementor elementor-6847\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dd0a945 e-flex e-con-boxed e-con e-parent\" data-id=\"dd0a945\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fd14ea4 elementor-widget elementor-widget-text-editor\" data-id=\"fd14ea4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"407\" data-end=\"873\">In packaging, printing, and industrial applications, the strength of paper is a critical performance indicator. Among the most accurate ways to assess this property is through <strong data-start=\"583\" data-end=\"627\">short span compression testing for paper<\/strong>, a standardized method for measuring the compressive strength over a very short span. This test is essential for quality control in paperboard production, carton manufacturing, and corrugated board applications where buckling resistance matters.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b6ad712 e-flex e-con-boxed e-con e-parent\" data-id=\"b6ad712\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1a967aa elementor-widget elementor-widget-heading\" data-id=\"1a967aa\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Understanding the Test SCT and ISO 9895 Compliance<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d7e76cf e-flex e-con-boxed e-con e-parent\" data-id=\"d7e76cf\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d0209e3 elementor-widget elementor-widget-text-editor\" data-id=\"d0209e3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"936\" data-end=\"1252\">Bu <strong data-start=\"940\" data-end=\"977\">short span compression test (SCT)<\/strong> is guided by international standard <strong data-start=\"1014\" data-end=\"1026\">ISO 9895<\/strong>, which defines how paper and board samples should be prepared, clamped, and tested. The SCT method is designed to simulate real-world compressive forces, such as those encountered during stacking, folding, or machine feeding.<\/p><p data-start=\"1254\" data-end=\"1593\">In this method, a 15 mm-wide strip of paper is clamped with a span of just <strong data-start=\"1329\" data-end=\"1340\">0.70 mm<\/strong> between jaws. A compressive load is applied until the specimen buckles. The maximum force recorded is used to calculate the <strong data-start=\"1465\" data-end=\"1507\">short span compressive strength (SSCS)<\/strong>, typically expressed in <strong data-start=\"1532\" data-end=\"1540\">kN\/m<\/strong> veya <strong data-start=\"1544\" data-end=\"1553\">N.m\/g<\/strong> depending on the material basis weight.<\/p><p data-start=\"1595\" data-end=\"1632\"><strong data-start=\"1595\" data-end=\"1631\">Key elements of ISO 9895 include<\/strong>:<\/p><ul data-start=\"1633\" data-end=\"1869\"><li data-start=\"1633\" data-end=\"1673\"><p data-start=\"1635\" data-end=\"1673\">Clamp alignment to ensure parallelism.<\/p><\/li><li data-start=\"1674\" data-end=\"1755\"><p data-start=\"1676\" data-end=\"1755\">Pneumatic or mechanical clamping with specified force (typically 2300 \u00b1 500 N).<\/p><\/li><li data-start=\"1756\" data-end=\"1804\"><p data-start=\"1758\" data-end=\"1804\">Test speed customization based on paper grade.<\/p><\/li><li data-start=\"1805\" data-end=\"1869\"><p data-start=\"1807\" data-end=\"1869\">Result recording with real-time display and optional printout.<\/p><\/li><\/ul><p data-start=\"1871\" data-end=\"2050\">This test is preferred over ring crush or other legacy methods due to its <strong data-start=\"1945\" data-end=\"1992\">better correlation with end-use performance<\/strong>, especially in corrugated board liners and fluting media.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f4bd7be e-flex e-con-boxed e-con e-parent\" data-id=\"f4bd7be\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b276572 elementor-widget elementor-widget-heading\" data-id=\"b276572\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why Short Span Compression Testing for Paper Matters<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8d2fcf9 e-flex e-con-boxed e-con e-parent\" data-id=\"8d2fcf9\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a5e9133 elementor-widget elementor-widget-text-editor\" data-id=\"a5e9133\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2115\" data-end=\"2234\">Paper and paperboard products must resist crushing under mechanical stress. Short span compression strength influences:<\/p><ul data-start=\"2235\" data-end=\"2544\"><li data-start=\"2235\" data-end=\"2298\"><p data-start=\"2237\" data-end=\"2298\"><strong data-start=\"2237\" data-end=\"2271\">Stacking load-bearing capacity<\/strong> of cartons during storage.<\/p><\/li><li data-start=\"2299\" data-end=\"2353\"><p data-start=\"2301\" data-end=\"2353\"><strong data-start=\"2301\" data-end=\"2342\">Runability in printing and converting<\/strong> processes.<\/p><\/li><li data-start=\"2354\" data-end=\"2461\"><p data-start=\"2356\" data-end=\"2461\"><strong data-start=\"2356\" data-end=\"2381\">Material optimization<\/strong>, allowing manufacturers to reduce basis weight without sacrificing performance.<\/p><\/li><li data-start=\"2462\" data-end=\"2544\"><p data-start=\"2464\" data-end=\"2544\"><strong data-start=\"2464\" data-end=\"2489\">Supplier benchmarking<\/strong> and compliance with international packaging standards.<\/p><\/li><\/ul><p data-start=\"2546\" data-end=\"2703\">Therefore, short span compression testing for paper plays a vital role in <strong data-start=\"2620\" data-end=\"2675\">cost control, quality assurance, and sustainability<\/strong> in modern packaging chains.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-739b84b e-con-full e-flex e-con e-parent\" data-id=\"739b84b\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-29257df elementor-widget elementor-widget-heading\" data-id=\"29257df\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How the SCT Method Works in Practice<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ae6631e e-flex e-con-boxed e-con e-parent\" data-id=\"ae6631e\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a17c8a4 elementor-widget elementor-widget-text-editor\" data-id=\"a17c8a4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2752\" data-end=\"2798\">Here\u2019s a brief overview of the test procedure:<\/p><ol data-start=\"2799\" data-end=\"3348\"><li data-start=\"2799\" data-end=\"2915\"><p data-start=\"2802\" data-end=\"2915\"><strong data-start=\"2802\" data-end=\"2824\">\u00d6rnek Haz\u0131rlama<\/strong><br data-start=\"2824\" data-end=\"2827\" \/>A 15 mm \u00d7 60 mm paper strip is conditioned and prepared per ISO 187 or lab protocols.<\/p><\/li><li data-start=\"2917\" data-end=\"3049\"><p data-start=\"2920\" data-end=\"3049\"><strong data-start=\"2920\" data-end=\"2932\">S\u0131k\u0131\u015ft\u0131rma<\/strong><br data-start=\"2932\" data-end=\"2935\" \/>The strip is clamped in <strong data-start=\"2962\" data-end=\"2979\">parallel jaws<\/strong> with a short 0.70 mm gap. Pneumatic clamps offer consistent pressure.<\/p><\/li><li data-start=\"3051\" data-end=\"3170\"><p data-start=\"3054\" data-end=\"3170\"><strong data-start=\"3054\" data-end=\"3074\">S\u0131k\u0131\u015ft\u0131rma Testi<\/strong><br data-start=\"3074\" data-end=\"3077\" \/>The jaws move inward at a defined speed, applying compressive force until the paper fails.<\/p><\/li><li data-start=\"3172\" data-end=\"3348\"><p data-start=\"3175\" data-end=\"3348\"><strong data-start=\"3175\" data-end=\"3194\">Veri Toplama<\/strong><br data-start=\"3194\" data-end=\"3197\" \/>Bu <strong data-start=\"3204\" data-end=\"3233\">maximum compressive force<\/strong> is recorded and converted into SSCS. Readings can be displayed in multiple units or printed via built-in printers.<\/p><\/li><\/ol><p data-start=\"3350\" data-end=\"3589\">To obtain <strong data-start=\"3360\" data-end=\"3395\">repeatable and accurate results<\/strong>, precision alignment of clamps and stability of movement are essential. That\u2019s where specialized equipment like the <strong data-start=\"3512\" data-end=\"3569\">Cell Instruments SCT-01 Short Span Compression Tester<\/strong> makes a difference.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a0ba8d5 e-flex e-con-boxed e-con e-parent\" data-id=\"a0ba8d5\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d07d4f elementor-widget elementor-widget-heading\" data-id=\"7d07d4f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Recommended Equipment: Cell Instruments SCT-01 Short Span Compression Tester<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd96b64 e-flex e-con-boxed e-con e-parent\" data-id=\"fd96b64\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-44e6158 e-con-full e-flex e-con e-child\" data-id=\"44e6158\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf9c874 elementor-widget elementor-widget-video\" data-id=\"bf9c874\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=FXr-QgOkRws&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5e2ad3c e-con-full e-flex e-con e-child\" data-id=\"5e2ad3c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3dc5c57 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"3dc5c57\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Bu<a href=\"https:\/\/www.qualitester.com\/tr\/?s=SCT-01\" target=\"_blank\" rel=\"noopener\"> <strong data-start=\"3682\" data-end=\"3692\">SCT-01<\/strong> <\/a>from Cell Instruments is engineered for <strong data-start=\"3733\" data-end=\"3791\">high-accuracy short span compression testing for paper<\/strong>, fully compliant with <a href=\"https:\/\/www.qualitester.com\/tr\/urun-kategori\/iso\/iso-9895\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\"><strong data-start=\"3814\" data-end=\"3826\">ISO 9895<\/strong><\/a>. With <strong data-start=\"3833\" data-end=\"3861\">PLC kontroll\u00fc \u00e7al\u0131\u015fma<\/strong>, pneumatic sample clamping, and <strong data-start=\"3894\" data-end=\"3923\">adjustable speed settings<\/strong>, it delivers unmatched performance in labs and production environments.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4dca79e e-flex e-con-boxed e-con e-parent\" data-id=\"4dca79e\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-457d06c elementor-widget elementor-widget-text-editor\" data-id=\"457d06c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3997\" data-end=\"4016\">Highlights include:<\/p><ul data-start=\"4017\" data-end=\"4198\"><li data-start=\"4017\" data-end=\"4065\"><p data-start=\"4019\" data-end=\"4065\">Multi-unit data display: Newtons, kN\/m, N.m\/g.<\/p><\/li><li data-start=\"4066\" data-end=\"4108\"><p data-start=\"4068\" data-end=\"4108\">Micro-printer for instant result output.<\/p><\/li><li data-start=\"4109\" data-end=\"4152\"><p data-start=\"4111\" data-end=\"4152\">RS-232 interface for digital integration.<\/p><\/li><li data-start=\"4153\" data-end=\"4198\"><p data-start=\"4155\" data-end=\"4198\">Over-range protection and safety enclosure.<\/p><\/li><\/ul><p data-start=\"4200\" data-end=\"4389\">Bu <strong data-start=\"4204\" data-end=\"4214\">SCT-01<\/strong> is particularly well-suited for <strong data-start=\"4247\" data-end=\"4321\">paperboard producers, packaging converters, and quality assurance labs<\/strong> that demand traceable, consistent, and efficient testing workflows.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4eaafa8 e-flex e-con-boxed e-con e-parent\" data-id=\"4eaafa8\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-65ee10d elementor-widget elementor-widget-heading\" data-id=\"65ee10d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion: Driving Paper Packaging Quality with SCT Testing<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a14cb5a e-flex e-con-boxed e-con e-parent\" data-id=\"a14cb5a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-48e91ef e-con-full e-flex e-con e-child\" data-id=\"48e91ef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0a46b24 elementor-widget elementor-widget-text-editor\" data-id=\"0a46b24\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>As packaging evolves to meet sustainability and performance demands, <strong data-start=\"4531\" data-end=\"4575\">short span compression testing for paper<\/strong> becomes an indispensable tool for evaluating strength and functionality. Following the <a href=\"https:\/\/www.iso.org\/standard\/41400.html\" target=\"_blank\" rel=\"noopener nofollow\"><strong data-start=\"4663\" data-end=\"4675\">ISO 9895<\/strong><\/a> standard and implementing reliable SCT testers ensures that every roll or sheet of paper meets the intended mechanical criteria.<\/p><p>With the right testing approach, businesses can reduce material use, minimize product failures, and improve packaging performance.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6fe2636 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"6fe2636\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/SCT-01-Short-Span-Compression-Tester_11zon-1024x1024.webp\" class=\"attachment-large size-large wp-image-6849\" alt=\"The SCT-01 from Cell Instruments is engineered for high-accuracy short span compression testing for paper, fully compliant with ISO 9895.\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/SCT-01-Short-Span-Compression-Tester_11zon-1024x1024.webp 1024w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/SCT-01-Short-Span-Compression-Tester_11zon-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/SCT-01-Short-Span-Compression-Tester_11zon-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/SCT-01-Short-Span-Compression-Tester_11zon-768x768.webp 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/SCT-01-Short-Span-Compression-Tester_11zon-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/SCT-01-Short-Span-Compression-Tester_11zon-600x600.webp 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/SCT-01-Short-Span-Compression-Tester_11zon-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/SCT-01-Short-Span-Compression-Tester_11zon.webp 1080w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d10ef56 e-flex e-con-boxed e-con e-parent\" data-id=\"d10ef56\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a4b684f elementor-widget elementor-widget-text-editor\" data-id=\"a4b684f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>\u00a0For professionals looking to adopt or optimize SCT testing, Cell Instruments offers trusted solutions and expert technical support tailored to global quality standards.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>In packaging, printing, and industrial applications, the strength of paper is a critical performance indicator. Among the most accurate ways to assess this property is through short span compression testing for paper, a standardized method for measuring the compressive strength over a very short span. This test is essential for quality control in paperboard production, &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/tr\/short-span-compression-testing-for-paper\/\"> <span class=\"screen-reader-text\">Short Span Compression Testing for Paper<\/span> Devam\u0131 \"<\/a><\/p>","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-6847","post","type-post","status-publish","format-standard","hentry","category-test-method"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/posts\/6847","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/comments?post=6847"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/posts\/6847\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/media?parent=6847"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/categories?post=6847"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.qualitester.com\/tr\/wp-json\/wp\/v2\/tags?post=6847"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}