{"id":5124,"date":"2024-10-29T16:56:05","date_gmt":"2024-10-29T08:56:05","guid":{"rendered":"https:\/\/www.qualitester.com\/?post_type=product&#038;p=5124"},"modified":"2024-12-05T12:00:24","modified_gmt":"2024-12-05T04:00:24","slug":"sale-syringe-plunger-glide-force-tester","status":"publish","type":"product","link":"https:\/\/www.qualitester.com\/sv\/produkt-2\/sale-syringe-plunger-glide-force-tester\/","title":{"rendered":"MST-01 Tester f\u00f6r medicinska sprutor"},"content":{"rendered":"<p>Den <strong>Testare av glidkraft f\u00f6r spruta och kolv<\/strong> \u00e4r ett specialiserat instrument som \u00e4r utformat f\u00f6r att m\u00e4ta den kraft som kr\u00e4vs f\u00f6r att driva kolven i hypodermiska sprutor, vilket s\u00e4kerst\u00e4ller kvaliteten och s\u00e4kerheten f\u00f6r medicintekniska produkter som anv\u00e4nds i patientv\u00e5rden. Med fokus p\u00e5 precision och efterlevnad av branschstandarder \u00e4r denna testare oumb\u00e4rlig vid testning av medicinska f\u00f6rpackningar och l\u00e4kemedel, eftersom den ger exakta bed\u00f6mningar av sprutans prestanda. Genom att fastst\u00e4lla viktiga m\u00e4tv\u00e4rden som kolvens glidkraft och kolvens glidkraft \u00e4r detta instrument avg\u00f6rande f\u00f6r tillverkare som str\u00e4var efter att uppfylla lagstadgade krav och leverera s\u00e4kra produkter till slutanv\u00e4ndarna.<\/p>\n<h2>ISO 7886-1 Compliance and Its Importance<\/h2>\n<p>The Syringe Plunger Glide Force Tester is fully compliant with <a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\"><strong>ISO 7886-1<\/strong><\/a>, an international standard governing the design and testing of sterile, single-use hypodermic syringes. <a href=\"https:\/\/www.qualitester.com\/sv\/produkt-kategori\/iso\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\">ISO 7886-1<\/a> specifies the methods for evaluating syringe functionality, including glide force measurement, to guarantee the syringe\u2019s usability and performance under varied conditions. Testing in accordance with ISO 7886-1 not only helps ensure user safety but also aids manufacturers in meeting regulatory standards essential for market approval.<\/p>\n<h2>Versatile Testing Methods<\/h2>\n<p>Detta <strong>Testare av glidkraft f\u00f6r spruta och kolv<\/strong> offers a variety of test methods to evaluate multiple aspects of syringe performance, including but not limited to:<\/p>\n<ul>\n<li><strong>Piston Glide Force Measurement<\/strong>: Precisely measures the force required to operate the syringe plunger, critical for ensuring a smooth and consistent glide.<\/li>\n<li><strong>Syringe Sliding Resistance Test<\/strong>: Evaluates the resistance during plunger movement to assess friction levels and ensure optimal functionality.<\/li>\n<li><strong>Liquid Leakage Test<\/strong>: Under compression, this test identifies any leaks at the plunger stopper, verifying the syringe\u2019s integrity when subjected to pressure.<\/li>\n<li><strong>Needle Penetration Test<\/strong>: Determines the force needed for the needle to penetrate, supporting safe and effective syringe use.<\/li>\n<li><strong>Plunger Pull-Out Test<\/strong>: Measures the force required to pull out the plunger, testing the syringe for structural resilience and user safety.<\/li>\n<\/ul>\n<p>These tests provide a comprehensive understanding of the syringe\u2019s mechanical properties, ensuring reliability and safety in its end-use application.<\/p>\n<h2>Wide Applications Across Industries<\/h2>\n<p>Den <strong>Testare av glidkraft f\u00f6r spruta och kolv<\/strong> is widely used across industries such as:<\/p>\n<ul>\n<li><strong>Medical Packaging<\/strong>: Ensures that syringes meet necessary mechanical standards.<\/li>\n<li><strong>Pharmaceutical Testing<\/strong>: Validates syringe performance, helping pharmaceutical companies guarantee product quality.<\/li>\n<li><strong>Organ f\u00f6r kvalitetskontroll<\/strong>: Provides regulatory assurance by confirming that medical syringes comply with safety standards.<\/li>\n<\/ul>\n<p>Through these applications, the tester supports quality control efforts, giving manufacturers and regulatory bodies confidence in syringe functionality and safety.<\/p>\n<h2>Viktiga f\u00f6rdelar<\/h2>\n<ul>\n<li><strong>Multi-Functional Testing<\/strong>: Embedded with multiple test programs in a single machine, this device is cost-effective and versatile for varied quality assurance tasks.<\/li>\n<li><strong>User-Defined Program Design<\/strong>: Customized testing programs are available to meet specific user requirements, accommodating various syringe types and sizes.<\/li>\n<li><strong>Standard-Conforming Processes<\/strong>: Testing processes strictly align with ISO standards, promoting reliable and consistent results across batches.<\/li>\n<li><strong>Flexibility for Diverse Medical Materials<\/strong>: Adaptable to the unique needs of medical-grade testing, enhancing its usability for a broad range of medical applications.<\/li>\n<\/ul>\n<h2>Advanced Technical Features<\/h2>\n<p>The Syringe Plunger Glide Force Tester integrates state-of-the-art technical features to ensure accuracy and ease of use:<\/p>\n<ul>\n<li><strong>PLC-kontrollenhet<\/strong>: Ensures precise control and monitoring of all testing parameters, offering reliable and repeatable test results.<\/li>\n<li><strong>7-Inch HMI Touch Screen<\/strong>: Provides a user-friendly interface, allowing operators to set and monitor tests with ease.<\/li>\n<li><strong>Precision Ball Screw Mechanism<\/strong>: Enhances speed and displacement accuracy for reliable test conditions.<\/li>\n<li><strong>Variabel testhastighet<\/strong>: Adjustable from 1 to 500 mm\/min, allowing for a customized approach depending on test requirements.<\/li>\n<li><strong>S\u00e4kerhetsfunktioner<\/strong>: Includes position restrictors, overload protection, and an automatic return function to prevent damage and ensure operator safety.<\/li>\n<\/ul>\n<h2>Customizable Clamps for Specialized Testing<\/h2>\n<p>The Syringe Plunger Glide Force Tester features customizable clamps made on demand to fit a range of syringe designs. This flexibility allows users to adapt the device to various configurations, ensuring that every test is accurate, relevant, and reliable.<\/p>\n<h2>Huvudparametrar<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: center;\"><strong>Testomr\u00e5de<\/strong><\/td>\n<td style=\"text-align: center;\">50N (customizable as needed)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><strong>Stroke<\/strong><\/td>\n<td style=\"text-align: center;\">200 mm (utan kl\u00e4mma)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><strong>Testhastighet<\/strong><\/td>\n<td style=\"text-align: center;\">1~500 mm\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><strong>Noggrannhet f\u00f6r f\u00f6rskjutning<\/strong><\/td>\n<td style=\"text-align: center;\">0.01 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><strong>Overall Accuracy<\/strong><\/td>\n<td style=\"text-align: center;\">0,5% F.S.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><strong>Output Options<\/strong><\/td>\n<td style=\"text-align: center;\">Screen, Microprinter, RS232 (optional)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><strong>Str\u00f6mf\u00f6rs\u00f6rjning<\/strong><\/td>\n<td style=\"text-align: center;\">110~220V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Vanliga fr\u00e5gor<\/h2>\n<ol>\n<li><strong>What is the purpose of the Syringe Plunger Glide Force Tester?<\/strong>\n<ul>\n<li>It measures the force required to move the syringe plunger, ensuring it meets quality standards for smooth operation and patient safety.<\/li>\n<\/ul>\n<\/li>\n<li><strong>How does this tester comply with ISO 7886-1?<\/strong>\n<ul>\n<li>The tester adheres to ISO 7886-1 requirements, offering standardized test methods to verify syringe performance and usability.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Can the tester accommodate different syringe designs?<\/strong>\n<ul>\n<li>Yes, the tester includes customizable clamps that adapt to various syringe designs, enabling flexible testing.<\/li>\n<\/ul>\n<\/li>\n<li><strong>What types of tests can be performed with this instrument?<\/strong>\n<ul>\n<li>Tests include piston glide force, syringe sliding resistance, liquid leakage, needle penetration, and plunger pull-out.<\/li>\n<\/ul>\n<\/li>\n<li><strong>How is data output managed?<\/strong>\n<ul>\n<li>Data can be outputted to the screen, microprinter, or RS232 interface, providing multiple ways to record and analyze results.<\/li>\n<\/ul>\n<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Den <strong>Testare av glidkraft f\u00f6r spruta och kolv<\/strong> \u00e4r ett specialiserat instrument som \u00e4r utformat f\u00f6r att m\u00e4ta den kraft som kr\u00e4vs f\u00f6r att driva kolven i hypodermiska sprutor, vilket s\u00e4kerst\u00e4ller kvaliteten och s\u00e4kerheten f\u00f6r medicintekniska produkter som anv\u00e4nds i patientv\u00e5rden. Med fokus p\u00e5 precision och efterlevnad av branschstandarder \u00e4r denna testare oumb\u00e4rlig vid testning av medicinska f\u00f6rpackningar och l\u00e4kemedel, eftersom den ger exakta bed\u00f6mningar av sprutans prestanda. Genom att fastst\u00e4lla viktiga m\u00e4tv\u00e4rden som kolvens glidkraft och kolvens glidkraft \u00e4r detta instrument avg\u00f6rande f\u00f6r tillverkare som str\u00e4var efter att uppfylla lagstadgade krav och leverera s\u00e4kra produkter till slutanv\u00e4ndarna.<\/p>","protected":false},"featured_media":6220,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":""},"product_cat":[679,845,1121,1122,1053,1120,1123,1124,149,95],"product_tag":[],"class_list":["post-5124","product","type-product","status-publish","has-post-thumbnail","product_cat-tensile-tester","product_cat-customization","product_cat-iso-11040-4","product_cat-iso-11608-5","product_cat-iso-7886-1","product_cat-iso-8537","product_cat-usp","product_cat-usp-382","product_cat-pharma-and-medical-testers","product_cat-products","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/product\/5124","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/comments?post=5124"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/product\/5124\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/media\/6220"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/media?parent=5124"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/product_cat?post=5124"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/product_tag?post=5124"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}