{"id":6719,"date":"2025-06-30T16:52:24","date_gmt":"2025-06-30T08:52:31","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=6719"},"modified":"2026-07-21T16:56:21","modified_gmt":"2026-07-21T08:56:21","slug":"pstc-16","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/sv\/standards\/pstc-16\/","title":{"rendered":"PSTC 16"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"381\" data-end=\"855\">PSTC 16<br \/>\nLoop Tack Testing of Pressure Sensitive Tapes and Films<\/h1>\n<p data-start=\"539\" data-end=\"981\">Den <a href=\"https:\/\/www.qualitester.com\/sv\/standards\/astm-d3420\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"543\" data-end=\"554\">PSTC 16<\/strong><\/a> standard plays a vital role in quality control for adhesive products such as pressure-sensitive tapes, films, medical dressings, and industrial labels. Among the many parameters assessed in adhesive performance, <strong data-start=\"767\" data-end=\"780\">\u00f6gla tack<\/strong>\u2014or the initial \u201cstick\u201d upon contact\u2014is one of the most critical. This property determines how well a material bonds on first touch, impacting everything from user experience to functional reliability.<\/p>\n<p data-start=\"983\" data-end=\"1235\">In this article, we will explore the fundamentals of <strong data-start=\"1036\" data-end=\"1047\">PSTC 16<\/strong>, how the <strong data-start=\"1057\" data-end=\"1099\">pressure sensitive tape loop tack test<\/strong> works, and how Cell Instruments\u2019 <strong data-start=\"1133\" data-end=\"1153\">\u00d6glan Tack Tester<\/strong> provides accurate, efficient, and compliant solutions for industry professionals.<\/p>\n<h2 data-start=\"1095\" data-end=\"1451\">Understanding Loop Tack and Its Role in Adhesive Performance<\/h2>\n<p data-start=\"1308\" data-end=\"1611\">Loop tack is the <strong data-start=\"1325\" data-end=\"1390\">peak force required to separate a pressure-sensitive adhesive<\/strong> (PSA) from a test surface after brief contact under minimal pressure. Unlike peel adhesion, which measures sustained force over distance, <strong data-start=\"1529\" data-end=\"1542\">\u00f6gla tack<\/strong> quantifies instant adhesion. This makes it especially important for:<\/p>\n<ul data-start=\"1613\" data-end=\"1967\">\n<li data-start=\"1613\" data-end=\"1688\">\n<p data-start=\"1615\" data-end=\"1688\"><strong data-start=\"1615\" data-end=\"1638\">Labels and stickers<\/strong> applied in automated or high-speed environments<\/p>\n<\/li>\n<li data-start=\"1689\" data-end=\"1790\">\n<p data-start=\"1691\" data-end=\"1790\"><strong data-start=\"1691\" data-end=\"1712\">Medical adhesives<\/strong> like wound dressings and electrode patches, where reliable contact is vital<\/p>\n<\/li>\n<li data-start=\"1791\" data-end=\"1872\">\n<p data-start=\"1793\" data-end=\"1872\"><strong data-start=\"1793\" data-end=\"1825\">Protective and masking tapes<\/strong> that must adhere quickly to various surfaces<\/p>\n<\/li>\n<li data-start=\"1873\" data-end=\"1967\">\n<p data-start=\"1875\" data-end=\"1967\"><strong data-start=\"1875\" data-end=\"1898\">F\u00f6rpackningsmaterial<\/strong> that require firm initial bonding under minimal application pressure<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1969\" data-end=\"2145\">By assessing loop tack using <strong data-start=\"1998\" data-end=\"2009\">PSTC 16<\/strong>, manufacturers gain clear, quantitative insights into adhesive responsiveness\u2014crucial for optimizing formulations and process settings.<\/p>\n<h2 data-start=\"2075\" data-end=\"2354\">Loop Tack, Pressure Sensitive Tape Loop Tack Test, and PSTC 16<\/h2>\n<p data-start=\"2220\" data-end=\"2378\">Den <strong data-start=\"2224\" data-end=\"2266\">pressure sensitive tape loop tack test<\/strong> definierad i <strong data-start=\"2278\" data-end=\"2289\">PSTC 16<\/strong> provides a repeatable, controlled procedure to evaluate tackiness. The process includes:<\/p>\n<ol data-start=\"2380\" data-end=\"2933\">\n<li data-start=\"2380\" data-end=\"2524\">\n<p data-start=\"2383\" data-end=\"2524\"><strong data-start=\"2383\" data-end=\"2405\">F\u00f6rberedelse av prov<\/strong>: A strip of adhesive tape (typically 25 mm \u00d7 175 mm or 125 mm) is formed into a loop with the adhesive facing outward.<\/p>\n<\/li>\n<li data-start=\"2525\" data-end=\"2656\">\n<p data-start=\"2528\" data-end=\"2656\"><strong data-start=\"2528\" data-end=\"2545\">Contact Phase<\/strong>: The loop is gently lowered onto a standardized test plate (usually polished float glass) using gravity alone.<\/p>\n<\/li>\n<li data-start=\"2657\" data-end=\"2761\">\n<p data-start=\"2660\" data-end=\"2761\"><strong data-start=\"2660\" data-end=\"2680\">Separation Phase<\/strong>: The plate or loop is moved vertically at a controlled speed (e.g., 300 mm\/min).<\/p>\n<\/li>\n<li data-start=\"2762\" data-end=\"2933\">\n<p data-start=\"2765\" data-end=\"2933\"><strong data-start=\"2765\" data-end=\"2780\">M\u00e4tning<\/strong>: The tester records the <strong data-start=\"2805\" data-end=\"2834\">maximum force (peak load)<\/strong> needed to initiate separation. This is the <strong data-start=\"2878\" data-end=\"2897\">loop tack value<\/strong>, typically reported in Newtons (N).<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"2935\" data-end=\"3058\">This method simulates real-world application conditions, ensuring that adhesives meet customer and regulatory expectations.<\/p>\n<h2 data-start=\"2539\" data-end=\"2603\">Standards Compliance: PSTC 16, ASTM D6195, and FINAT FTM 9<img fetchpriority=\"high\" decoding=\"async\" class=\"alignright wp-image-6974 size-medium\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/4.LTT-01-Loop-Tack-Tester-3_11zon-300x300.webp\" alt=\"Loop Tack Tester fr\u00e5n Cell Instruments m\u00f6jligg\u00f6r noggranna och repeterbara provningar som helt uppfyller kraven i PSTC 16 och tillh\u00f6rande metoder\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/4.LTT-01-Loop-Tack-Tester-3_11zon-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/4.LTT-01-Loop-Tack-Tester-3_11zon-1024x1024.webp 1024w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/4.LTT-01-Loop-Tack-Tester-3_11zon-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/4.LTT-01-Loop-Tack-Tester-3_11zon-768x768.webp 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/4.LTT-01-Loop-Tack-Tester-3_11zon-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/4.LTT-01-Loop-Tack-Tester-3_11zon-600x600.webp 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/4.LTT-01-Loop-Tack-Tester-3_11zon-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/4.LTT-01-Loop-Tack-Tester-3_11zon.webp 1080w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/h2>\n<p data-start=\"3129\" data-end=\"3242\">While <strong data-start=\"3135\" data-end=\"3146\">PSTC 16<\/strong> is widely used in North America, international testing may reference related standards such as:<\/p>\n<ul data-start=\"3244\" data-end=\"3376\">\n<li data-start=\"3244\" data-end=\"3313\">\n<p data-start=\"3246\" data-end=\"3313\"><strong data-start=\"3246\" data-end=\"3260\">ASTM D6195<\/strong> \u2013 Test Method C closely mirrors PSTC 16 procedures<\/p>\n<\/li>\n<li data-start=\"3314\" data-end=\"3376\">\n<p data-start=\"3316\" data-end=\"3376\"><strong data-start=\"3316\" data-end=\"3331\">FINAT FTM 9<\/strong> \u2013 A European counterpart for tack evaluation<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3378\" data-end=\"3672\">Regardless of the standard, the core principle remains consistent: <strong data-start=\"3445\" data-end=\"3521\">quantify the instantaneous bond strength of pressure-sensitive adhesives<\/strong> under defined conditions. For manufacturers, testing in accordance with these methods ensures compatibility with global clients and regulatory bodies.<\/p>\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Loop tack test according to  ASTM D6195, PSTC-16, FINAT No 9.\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/L1HbDnq-LxQ?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<h2 data-start=\"3720\" data-end=\"3976\">Cell Instruments\u2019 Loop Tack Tester: Precision Meets Simplicity<\/h2>\n<p data-start=\"3747\" data-end=\"3917\">Den <strong data-start=\"3751\" data-end=\"3771\">\u00d6glan Tack Tester<\/strong> fr\u00e5n <strong data-start=\"3777\" data-end=\"3797\">Cellinstrument<\/strong> delivers accurate and repeatable testing in full compliance with <strong data-start=\"3863\" data-end=\"3874\">PSTC 16<\/strong> and related methods. Key features include:<\/p>\n<ul data-start=\"3919\" data-end=\"4427\">\n<li data-start=\"3919\" data-end=\"4003\">\n<p data-start=\"3921\" data-end=\"4003\"><strong data-start=\"3921\" data-end=\"3977\">Industrial-grade PLC control with 7-inch touchscreen<\/strong> f\u00f6r intuitiv anv\u00e4ndning<\/p>\n<\/li>\n<li data-start=\"4004\" data-end=\"4093\">\n<p data-start=\"4006\" data-end=\"4093\"><strong data-start=\"4006\" data-end=\"4059\">Customizable speed, dwell time, and stroke length<\/strong> for full procedural flexibility<\/p>\n<\/li>\n<li data-start=\"4094\" data-end=\"4188\">\n<p data-start=\"4096\" data-end=\"4188\"><strong data-start=\"4096\" data-end=\"4128\">High-resolution load sensors<\/strong> capable of detecting slight variations in loop tack force<\/p>\n<\/li>\n<li data-start=\"4189\" data-end=\"4266\">\n<p data-start=\"4191\" data-end=\"4266\"><strong data-start=\"4191\" data-end=\"4230\">Standardized float glass test plate<\/strong> for repeatable contact conditions<\/p>\n<\/li>\n<li data-start=\"4267\" data-end=\"4348\">\n<p data-start=\"4269\" data-end=\"4348\"><strong data-start=\"4269\" data-end=\"4305\">Microprinter and RS232 data port<\/strong> for instant test reports and data export<\/p>\n<\/li>\n<li data-start=\"4349\" data-end=\"4427\">\n<p data-start=\"4351\" data-end=\"4427\"><strong data-start=\"4351\" data-end=\"4379\">Multi-unit force display<\/strong> (N, gf, kgf, lbf) to meet regional requirements<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4429\" data-end=\"4596\">Oavsett om det g\u00e4ller testning <strong data-start=\"4445\" data-end=\"4458\">PSA tapes<\/strong>, <strong data-start=\"4460\" data-end=\"4481\">medical adhesives<\/strong>, eller <strong data-start=\"4486\" data-end=\"4508\">labeling materials<\/strong>, Cell Instruments\u2019 system supports R&amp;D, QC, and production-level evaluations with ease.<\/p>\n<h2 data-start=\"4238\" data-end=\"4279\">Slutsats<\/h2>\n<p data-start=\"4619\" data-end=\"4961\">Testing to <a href=\"https:\/\/www.qualitester.com\/sv\/standards\/astm-d3420\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"4630\" data-end=\"4641\">PSTC 16<\/strong> <\/a>standards is essential for validating the <strong data-start=\"4684\" data-end=\"4697\">\u00f6gla tack<\/strong> of pressure-sensitive adhesives used in tapes, labels, medical dressings, and industrial laminates. The <strong data-start=\"4802\" data-end=\"4844\">pressure sensitive tape loop tack test<\/strong> delivers critical data on initial bond strength, supporting both performance optimization and regulatory compliance.<\/p>\n<p data-start=\"4963\" data-end=\"5153\">For laboratories and production environments seeking accuracy, efficiency, and repeatability, Cell Instruments\u2019 <strong data-start=\"5075\" data-end=\"5095\">\u00d6glan Tack Tester<\/strong> offers an advanced solution tailored to real-world needs.<\/p>\n<p data-start=\"4770\" data-end=\"5262\">Att f\u00f6rst\u00e5 och till\u00e4mpa <strong data-start=\"4814\" data-end=\"4828\">ASTM D3420<\/strong> ensures that your packaging and film materials meet performance expectations under dynamic stress. By using a <strong data-start=\"4939\" data-end=\"4970\">slagprovare f\u00f6r filmpendel<\/strong>\u2014especially one like the <strong data-start=\"4995\" data-end=\"5022\">Cell Instruments PIT-01<\/strong>\u2014you can standardize quality control, reduce product failure rates, and comply with international specifications. Whether you&#8217;re developing new films or conducting batch testing, ASTM D3420 remains an essential tool in your testing arsenal.<\/p>\n<h2 data-start=\"5269\" data-end=\"5318\">Vanliga fr\u00e5gor<\/h2>\n<p data-start=\"5170\" data-end=\"5333\"><strong data-start=\"5170\" data-end=\"5193\">1. What is PSTC 16?<\/strong><br data-start=\"5193\" data-end=\"5196\" \/>PSTC 16 is a standard method used to measure the initial tack or bonding strength of pressure-sensitive adhesives using a loop tack test.<\/p>\n<p data-start=\"5335\" data-end=\"5539\"><strong data-start=\"5335\" data-end=\"5369\">2. Why is loop tack important?<\/strong><br data-start=\"5369\" data-end=\"5372\" \/>Loop tack reflects the adhesive\u2019s ability to bond instantly upon contact, which is crucial for performance in fast-paced applications like labeling and medical taping.<\/p>\n<p data-start=\"5541\" data-end=\"5695\"><strong data-start=\"5541\" data-end=\"5601\">3. What materials can be tested with a loop tack tester?<\/strong><br data-start=\"5601\" data-end=\"5604\" \/>Pressure-sensitive tapes, labels, films, medical adhesives, protective laminates, and more.<\/p>\n<p data-start=\"5697\" data-end=\"5900\"><strong data-start=\"5697\" data-end=\"5769\">4. How does the Cell Instruments Loop Tack Tester ensure compliance?<\/strong><br data-start=\"5769\" data-end=\"5772\" \/>It uses standardized surfaces, adjustable parameters, and accurate sensors, all aligned with PSTC 16, ASTM, and FINAT standards.<\/p>\n<p data-start=\"5902\" data-end=\"6074\"><strong data-start=\"5902\" data-end=\"5965\">5. Can this tester be used in both R&amp;D and QC environments?<\/strong><br data-start=\"5965\" data-end=\"5968\" \/>Yes. It is designed for versatile applications, from formulation development to production quality checks.<\/p>","protected":false},"excerpt":{"rendered":"<p>PSTC 16 \u2013 Testning av vidh\u00e4ftningsf\u00f6rm\u00e5ga vid kontakt (Loop Tack) f\u00f6r tryckk\u00e4nsliga tejp och filmer Standarden PSTC 16 spelar en avg\u00f6rande roll i kvalitetskontrollen av sj\u00e4lvh\u00e4ftande produkter s\u00e5som tryckk\u00e4nsliga tejp, filmer, medicinska f\u00f6rband och industriella etiketter. Bland de m\u00e5nga parametrar som utv\u00e4rderas n\u00e4r det g\u00e4ller limmets prestanda \u00e4r loop tack \u2013 det vill s\u00e4ga den initiala \u201cvidh\u00e4ftningen\u201d vid kontakt \u2013 en av de mest avg\u00f6rande. \u2026<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/sv\/standards\/pstc-16\/\"> <span class=\"screen-reader-text\">PSTC 16<\/span> L\u00e4s mer \"<\/a><\/p>","protected":false},"author":4,"featured_media":6974,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-6719","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/pages\/6719","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/comments?post=6719"}],"version-history":[{"count":1,"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/pages\/6719\/revisions"}],"predecessor-version":[{"id":8059,"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/pages\/6719\/revisions\/8059"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/pages\/4948"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/media\/6974"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/sv\/wp-json\/wp\/v2\/media?parent=6719"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}