{"id":6648,"date":"2025-05-09T11:42:03","date_gmt":"2025-05-09T03:42:03","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=6648"},"modified":"2025-11-13T09:38:29","modified_gmt":"2025-11-13T01:38:29","slug":"iso-7886-1","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/sl\/standards\/iso-7886-1\/","title":{"rendered":"ISO 7886-1"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"370\" data-end=\"882\"><small>ISO 7886-1<\/small><\/h1>\n<h1 style=\"text-align: center;\" data-start=\"370\" data-end=\"882\"><small>Test s podko\u017eno injekcijsko brizgalko<\/small><\/h1>\n<p class=\"\" data-start=\"370\" data-end=\"882\">Spletna stran <strong data-start=\"349\" data-end=\"363\">ISO 7886-1<\/strong> Standard dolo\u010da zahteve glede zmogljivosti in varnosti za <em data-start=\"425\" data-end=\"446\">injekcijske brizge<\/em> namenjeni za enkratno uporabo, pri \u010demer se poudarjajo vidiki, kot so <em data-start=\"497\" data-end=\"514\">odpornost proti pu\u0161\u010danju<\/em>, <em data-start=\"516\" data-end=\"528\">mrtvi prostor<\/em>, in <em data-start=\"534\" data-end=\"547\">sila drsenja<\/em>. Proizvajalci in ekipe za zagotavljanje kakovosti morajo razumeti preskusne postopke, opisane v standardu ISO 7886-1, da se zagotovi skladnost izdelkov in varnost pacientov.<\/p>\n<p class=\"\" data-start=\"1369\" data-end=\"1391\">Standard ISO 7886-1 velja za:<\/p>\n<ul data-start=\"1393\" data-end=\"1559\">\n<li class=\"\" data-start=\"1393\" data-end=\"1438\">\n<p class=\"\" data-start=\"1395\" data-end=\"1438\">Sterilne brizge iz plasti\u010dnih materialov.<\/p>\n<\/li>\n<li class=\"\" data-start=\"1439\" data-end=\"1523\">\n<p class=\"\" data-start=\"1441\" data-end=\"1523\">Brizge, ki se uporabljajo skupaj s podko\u017enimi iglami za podko\u017ene ali intramuskularne injekcije.<\/p>\n<\/li>\n<li class=\"\" data-start=\"1524\" data-end=\"1559\">\n<p class=\"\" data-start=\"1526\" data-end=\"1559\">Brizge za enkratno uporabo.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"1561\" data-end=\"1706\">Ta standard <strong data-start=\"1580\" data-end=\"1593\">se ne uporablja<\/strong> za injekcijske brizge za inzulin (v skladu s standardom ISO 8537), za zobozdravstveno rabo (v skladu s standardom ISO 7885) ali za infuzijske \u010drpalke.<\/p>\n<hr class=\"\" data-start=\"884\" data-end=\"887\" \/>\n<h2 class=\"\" data-start=\"912\" data-end=\"952\">Presku\u0161anje po standardu ISO 7886 in njegov pomen<\/h2>\n<p class=\"\" data-start=\"954\" data-end=\"1117\"><strong data-start=\"954\" data-end=\"968\">ISO 7886-1<\/strong> se osredoto\u010da na zahteve glede zmogljivosti in preskusne metode za <em data-start=\"1026\" data-end=\"1047\">injekcijske brizge<\/em>, zlasti tisti, ki se uporabljajo z iglami ali brez njih. Ti testi zagotavljajo:<\/p>\n<h3 class=\"\" data-start=\"1861\" data-end=\"1895\">1. <strong data-start=\"1868\" data-end=\"1895\">Na\u010drtovanje in gradnja<\/strong><\/h3>\n<ul data-start=\"1896\" data-end=\"2054\">\n<li class=\"\" data-start=\"1896\" data-end=\"1951\">\n<p class=\"\" data-start=\"1898\" data-end=\"1951\">Prozorno ohi\u0161je za vizualni pregled vsebine.<\/p>\n<\/li>\n<li class=\"\" data-start=\"1952\" data-end=\"1997\">\n<p class=\"\" data-start=\"1954\" data-end=\"1997\">Stopnjevana skala, natisnjena s trajnim \u010drnilom.<\/p>\n<\/li>\n<li class=\"\" data-start=\"1998\" data-end=\"2054\">\n<p class=\"\" data-start=\"2000\" data-end=\"2054\">Zagotovite trdno pritrditev bata, da prepre\u010dite uhajanje ali izpadanje.<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2056\" data-end=\"2082\">2. <strong data-start=\"2063\" data-end=\"2082\">Natan\u010dnost merjenja prostornine<\/strong><\/h3>\n<ul data-start=\"2083\" data-end=\"2260\">\n<li class=\"\" data-start=\"2083\" data-end=\"2192\">\n<p class=\"\" data-start=\"2085\" data-end=\"2192\">Dejanska dobavljena prostornina mora v okviru dolo\u010denih odstopanj ustrezati nazivni prostornini, ozna\u010deni na cevi.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2193\" data-end=\"2260\">\n<p class=\"\" data-start=\"2195\" data-end=\"2260\">Natan\u010dnost se preizku\u0161a pri 10%, 50% in 100% nazivne zmogljivosti.<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2262\" data-end=\"2286\">3. <strong data-start=\"2269\" data-end=\"2286\">Preskusi tesnosti<\/strong><\/h3>\n<ul data-start=\"2287\" data-end=\"2457\">\n<li class=\"\" data-start=\"2287\" data-end=\"2384\">\n<p class=\"\" data-start=\"2289\" data-end=\"2384\"><strong data-start=\"2289\" data-end=\"2304\">Uhajanje zraka<\/strong> in . <strong data-start=\"2309\" data-end=\"2327\">iztekanje teko\u010dine<\/strong> se presku\u0161ajo pod dolo\u010denimi pogoji tlaka in prostornine.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2385\" data-end=\"2457\">\n<p class=\"\" data-start=\"2387\" data-end=\"2457\">Iz cevi ali med sestavnimi deli ne sme prihajati do vidnega uhajanja.<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2459\" data-end=\"2480\">4. <strong data-start=\"2466\" data-end=\"2480\">Dead Space<\/strong><\/h3>\n<ul data-start=\"2481\" data-end=\"2614\">\n<li class=\"\" data-start=\"2481\" data-end=\"2614\">\n<p class=\"\" data-start=\"2483\" data-end=\"2614\">Koli\u010dina, ki ostane v injekcijski brizgi po popolnem potisnitvi bata, ne sme presegati navedene najve\u010dje vrednosti (obi\u010dajno \u2264 0,07 ml).<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2616\" data-end=\"2643\">5. <strong data-start=\"2623\" data-end=\"2643\">Funkcija bata<\/strong><\/h3>\n<ul data-start=\"2644\" data-end=\"2782\">\n<li class=\"\" data-start=\"2644\" data-end=\"2708\">\n<p class=\"\" data-start=\"2646\" data-end=\"2708\">Bati se mora premikati gladko, brez zatikanja ali zdrsa.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2709\" data-end=\"2782\">\n<p class=\"\" data-start=\"2711\" data-end=\"2782\">Pri normalnem delovnem tlaku ne sme priti do pu\u0161\u010danja ali lo\u010devanja.<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2784\" data-end=\"2827\">6. <strong data-start=\"2791\" data-end=\"2827\">Zlomna sila in lo\u010ditvena sila<\/strong><\/h3>\n<ul data-start=\"2828\" data-end=\"2945\">\n<li class=\"\" data-start=\"2828\" data-end=\"2945\">\n<p class=\"\" data-start=\"2830\" data-end=\"2945\">Najve\u010dja sila, potrebna za zlom potisnega elementa ali lo\u010ditev sestavnih delov, ne sme biti manj\u0161a od varnostnih mejnih vrednosti.<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2947\" data-end=\"2974\">7. <strong data-start=\"2954\" data-end=\"2974\">Biokompatibilnost<\/strong><\/h3>\n<ul data-start=\"2975\" data-end=\"3080\">\n<li class=\"\" data-start=\"2975\" data-end=\"3080\">\n<p class=\"\" data-start=\"2977\" data-end=\"3080\">Materiali, ki pridejo v stik z zdravilom ali mestom injekcije, morajo uspe\u0161no prestati preskuse biokompatibilnosti iz serije standardov ISO 10993.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"1313\" data-end=\"1462\">Vsak preskus pomaga ugotoviti, ali je brizga varna, zanesljiva in ali deluje dosledno.<\/p>\n<hr class=\"\" data-start=\"1766\" data-end=\"1769\" \/>\n<h2 class=\"\" data-start=\"1568\" data-end=\"1616\">Metode presku\u0161anja injekcijskih brizgalk v standardu ISO 7886-1<\/h2>\n<h3 class=\"\" data-start=\"1618\" data-end=\"1673\">1. Preskus tesnosti injekcijskih brizgalk pod vakuumom (Priloga B)<img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-6651 alignright\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-B.webp\" alt=\"ISO 7886-1 Priloga B\" width=\"398\" height=\"327\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-B.webp 694w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-B-300x246.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-B-15x12.webp 15w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-B-600x493.webp 600w\" sizes=\"(max-width: 398px) 100vw, 398px\" \/><\/h3>\n<p class=\"\" data-start=\"1675\" data-end=\"1866\">Preizkusiti je treba uhajanje mimo zapore bata pod podtlakom, da se prepre\u010di onesna\u017eenje ali vdor zraka. To <strong data-start=\"1793\" data-end=\"1825\">preskus tesnosti s podko\u017eno injekcijsko brizgalko<\/strong> je nujno potrebno za preverjanje zrakotesnosti.<\/p>\n<ul data-start=\"1868\" data-end=\"2062\">\n<li class=\"\" data-start=\"1868\" data-end=\"1979\">\n<p class=\"\" data-start=\"1870\" data-end=\"1979\"><strong data-start=\"1870\" data-end=\"1881\">Metoda:<\/strong> Napolnite brizgo z vodo (vsaj do 25% prostornine), zategnite bat in ustvarite vakuum -88 kPa.<\/p>\n<\/li>\n<li class=\"\" data-start=\"1980\" data-end=\"2062\">\n<p class=\"\" data-start=\"1982\" data-end=\"2062\"><strong data-start=\"1982\" data-end=\"1998\">Opazka:<\/strong> Preverite, ali obstajajo morebitne pu\u0161\u010danje zraka ali odlepljenje zapore bata.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"2064\" data-end=\"2229\"><strong data-start=\"2064\" data-end=\"2090\">Priporo\u010dena oprema:<\/strong><br data-start=\"2090\" data-end=\"2093\" \/>Celi\u010dni instrumenti\u2019 <strong data-start=\"2111\" data-end=\"2141\">SLT-02 <a href=\"https:\/\/www.qualitester.com\/sl\/izdelek\/syringe-air-leakage-tester-iso-7886-1\/\">Naprava za preizku\u0161anje tesnosti injekcijskih brizgalk<\/a><\/strong> omogo\u010da natan\u010dno regulacijo vakuuma in avtomatsko od\u010ditavanje vrednosti, s \u010dimer zagotavlja skladnost s Prilogo B.<\/p>\n<hr class=\"\" data-start=\"2231\" data-end=\"2234\" \/>\n<h3 class=\"\" data-start=\"2236\" data-end=\"2303\">2. Preskus tesnosti teko\u010dine v injekcijski brizgi pod pritiskom (Priloga D)<\/h3>\n<p class=\"\" data-start=\"2305\" data-end=\"2418\">Spletna stran <strong data-start=\"2309\" data-end=\"2348\">preskus tesnosti teko\u010dine pri injekcijski brizgi<\/strong> preverja neopore\u010dnost injekcijske brizge pri aksialni in bo\u010dni mehanski obremenitvi.<\/p>\n<ul data-start=\"2420\" data-end=\"2647\">\n<li class=\"\" data-start=\"2420\" data-end=\"2565\">\n<p class=\"\" data-start=\"2422\" data-end=\"2565\"><strong data-start=\"2422\" data-end=\"2433\">Metoda:<\/strong> Po zaprtju \u0161obe se na bat deluje s stransko silo, da se ga odkloni, nato pa sledi aksialno stiskanje, s \u010dimer se simulira delovanje uporabnika.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2566\" data-end=\"2647\">\n<p class=\"\" data-start=\"2568\" data-end=\"2647\"><strong data-start=\"2568\" data-end=\"2584\">Opazka:<\/strong> Preverite, ali prihaja do uhajanja teko\u010dine pri tlakih 200 kPa in 300 kPa.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"2649\" data-end=\"2835\"><strong data-start=\"2649\" data-end=\"2675\">Priporo\u010dena oprema:<\/strong><br data-start=\"2675\" data-end=\"2678\" \/>Uporabite <strong data-start=\"2682\" data-end=\"2728\">SPPT-01 <a href=\"https:\/\/www.qualitester.com\/sl\/izdelek\/syringe-liquid-leakage-tester\/\">Naprava za preizku\u0161anje tesnosti brizgalk pod pozitivnim tlakom<\/a><\/strong>\u00a0iz podjetja Cell Instruments za izvajanje nadzorovanih mehanskih sil in spremljanje morebitnih okvar v neprepustnosti tesnila.<\/p>\n<hr class=\"\" data-start=\"2837\" data-end=\"2840\" \/>\n<h3 data-start=\"2842\" data-end=\"2907\">3. Preskus mrtvega prostora v injekcijski brizgi: zmanj\u0161anje koli\u010dine zavr\u017eenih zdravil (Priloga C)<\/h3>\n<p class=\"\" data-start=\"2909\" data-end=\"3067\">Mrtvi prostor ozna\u010duje koli\u010dino teko\u010dine, ki ostane v brizgi po popolnem iztiskanju. Prevelik mrtvi prostor lahko povzro\u010di izgubo zdravila in neto\u010dno odmerjanje.<\/p>\n<ul data-start=\"3069\" data-end=\"3238\">\n<li class=\"\" data-start=\"3069\" data-end=\"3162\">\n<p class=\"\" data-start=\"3071\" data-end=\"3162\"><strong data-start=\"3071\" data-end=\"3082\">Metoda:<\/strong> Pretehtajte prazno brizgo, nato pa jo pretehtajte \u0161e enkrat, potem ko ste jo napolnili z vodo in jo izpraznili.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3163\" data-end=\"3238\">\n<p class=\"\" data-start=\"3165\" data-end=\"3238\"><strong data-start=\"3165\" data-end=\"3181\">Izra\u010dun:<\/strong> Razlika v te\u017ei ka\u017ee, da <strong data-start=\"3217\" data-end=\"3231\">mrtvi prostor<\/strong> v ml.<\/p>\n<\/li>\n<\/ul>\n<hr class=\"\" data-start=\"3437\" data-end=\"3440\" \/>\n<h3 data-start=\"3442\" data-end=\"3490\">4. Preskus sile drsenja za bat brizge (Priloga E)<img decoding=\"async\" class=\"wp-image-6652 alignright\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-E.webp\" alt=\"ISO 7886-1 Priloga E\" width=\"272\" height=\"358\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-E.webp 546w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-E-228x300.webp 228w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-E-9x12.webp 9w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/><\/h3>\n<p class=\"\" data-start=\"3492\" data-end=\"3683\">Nemoteno gibanje bata je klju\u010dnega pomena za udobje uporabnika in natan\u010den nadzor nad odmerjanjem. To <strong data-start=\"3576\" data-end=\"3596\">preskus sile drsenja<\/strong> meri silo, potrebno za enakomerno delovanje bata skozi celoten hod.<\/p>\n<ul data-start=\"3685\" data-end=\"3873\">\n<li class=\"\" data-start=\"3685\" data-end=\"3798\">\n<p class=\"\" data-start=\"3687\" data-end=\"3798\"><strong data-start=\"3687\" data-end=\"3698\">Metoda:<\/strong> Mehanski preskusni stroj potiska bat z dolo\u010deno hitrostjo in pri tem v realnem \u010dasu bele\u017ei upornost.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3799\" data-end=\"3873\">\n<p class=\"\" data-start=\"3801\" data-end=\"3873\"><strong data-start=\"3801\" data-end=\"3813\">Namen:<\/strong> Preverja uporabnost injekcijskih brizgalk in njihovo enotnost med posameznimi serijami.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"3875\" data-end=\"4084\"><strong data-start=\"3875\" data-end=\"3901\">Priporo\u010dena oprema:<\/strong><br data-start=\"3901\" data-end=\"3904\" \/><strong data-start=\"3904\" data-end=\"3958\">Cell Instruments MST-01 <a href=\"https:\/\/www.qualitester.com\/sl\/izdelek\/sale-syringe-plunger-glide-force-tester\/\">Naprava za testiranje medicinskih injekcijskih brizgalk<\/a><\/strong>\u00a0je idealno za <strong data-start=\"3972\" data-end=\"3992\">preskus sile drsenja<\/strong> uporabe. Merilnik bele\u017ei profile sile in izpolnjuje zahteve glede natan\u010dnosti iz standarda ISO 7886-1.<\/p>\n<hr class=\"\" data-start=\"4086\" data-end=\"4089\" \/>\n<h2 class=\"\" data-start=\"4091\" data-end=\"4143\">Zakaj izbrati podjetje Cell Instruments za preskuse v skladu s standardom ISO 7886?<\/h2>\n<p class=\"\" data-start=\"4145\" data-end=\"4312\">Podjetje Cell Instruments ponuja celovit nabor re\u0161itev za testiranje injekcijskih brizgalk, ki proizvajalcem pomaga izpolniti in prese\u010di <strong data-start=\"4253\" data-end=\"4267\">ISO 7886-1<\/strong> zahteve. Na\u0161a oprema je namenjena:<\/p>\n<ul data-start=\"4313\" data-end=\"4476\">\n<li class=\"\" data-start=\"4313\" data-end=\"4344\">\n<p class=\"\" data-start=\"4315\" data-end=\"4344\">Visoka natan\u010dnost in avtomatizacija<\/p>\n<\/li>\n<li class=\"\" data-start=\"4345\" data-end=\"4386\">\n<p class=\"\" data-start=\"4347\" data-end=\"4386\">Skladnost z mednarodnimi standardi<\/p>\n<\/li>\n<li class=\"\" data-start=\"4387\" data-end=\"4422\">\n<p class=\"\" data-start=\"4389\" data-end=\"4422\">Enostavno upravljanje in bele\u017eenje podatkov<\/p>\n<\/li>\n<li class=\"\" data-start=\"4423\" data-end=\"4476\">\n<p class=\"\" data-start=\"4425\" data-end=\"4476\">Prilagodljivost, ki omogo\u010da prilagajanje posebnim testnim konfiguracijam<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"4478\" data-end=\"4682\">Ne glede na to, ali preverjate zasnovo izdelka ali vodite testiranje za spro\u0161\u010danje serij, <strong data-start=\"4554\" data-end=\"4564\">SLT-01<\/strong>, <strong data-start=\"4566\" data-end=\"4577\">SPPT-01<\/strong>, in <strong data-start=\"4583\" data-end=\"4593\">MST-01<\/strong> zagotavljajo zanesljive in ponovljive rezultate, prilagojene potrebam industrije medicinskih pripomo\u010dkov.<\/p>\n<hr class=\"\" data-start=\"4684\" data-end=\"4687\" \/>\n<p class=\"\" data-start=\"4704\" data-end=\"5183\">Doseganje skladnosti z <a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\"><strong data-start=\"4730\" data-end=\"4744\">ISO 7886-1<\/strong><\/a> To ni le regulativna ovira \u2013 gre za zavezo kakovosti in varnosti pacientov. Z razumevanjem in izvajanjem klju\u010dnih preiskav, kot so <strong data-start=\"4885\" data-end=\"4912\">test s podko\u017eno injekcijo<\/strong>, <strong data-start=\"4914\" data-end=\"4927\">preskus tesnosti<\/strong>, <strong data-start=\"4929\" data-end=\"4956\">preskus mrtvega prostora v injekcijski brizgi<\/strong>, in <strong data-start=\"4962\" data-end=\"4982\">preskus sile drsenja<\/strong>, lahko proizvajalci brez skrbi uvajajo izdelke na trg. Opremite svoj laboratorij z naprednimi merilnimi napravami podjetja Cell Instruments, da poenostavite testiranje in zagotovite natan\u010dnost v vseh fazah proizvodnje injekcijskih brizgalk.<\/p>\n<p class=\"\" data-start=\"5185\" data-end=\"5296\"><strong data-start=\"5185\" data-end=\"5296\">Za tehni\u010dna svetovanja, izbiro instrumentov ali re\u0161itve po meri se \u0161e danes obrnite na podjetje Cell Instruments.<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>ISO 7886-1 Preskus podko\u017enih brizg Standard ISO 7886-1 opredeljuje zahteve za delovanje in varnost podko\u017enih brizg za enkratno uporabo, pri \u010demer poudarja vidike, kot so odpornost proti pu\u0161\u010danju, mrtvi prostor in drsna sila. Proizvajalci in ekipe za zagotavljanje kakovosti morajo razumeti postopke presku\u0161anja, opisane v standardu ISO 7886-1, da zagotovijo skladnost izdelka in varnost bolnikov. ISO 7886-1 ...<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/sl\/standards\/iso-7886-1\/\"> <span class=\"screen-reader-text\">ISO 7886-1<\/span> Preberite ve\u010d \u00bb<\/a><\/p>","protected":false},"author":4,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-6648","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/sl\/wp-json\/wp\/v2\/pages\/6648","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/sl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/sl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sl\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sl\/wp-json\/wp\/v2\/comments?post=6648"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/sl\/wp-json\/wp\/v2\/pages\/6648\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sl\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/sl\/wp-json\/wp\/v2\/media?parent=6648"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}