{"id":2268,"date":"2023-05-18T10:57:00","date_gmt":"2023-05-18T02:57:00","guid":{"rendered":"https:\/\/www.qualitester.com\/?post_type=product&#038;p=2268"},"modified":"2025-04-08T16:16:55","modified_gmt":"2025-04-08T08:16:55","slug":"lt-01-leak-tester","status":"publish","type":"product","link":"https:\/\/www.qualitester.com\/sk\/produkt-2\/lt-01-leak-tester\/","title":{"rendered":"LT-01 Tester netesnost\u00ed"},"content":{"rendered":"<h2 data-start=\"1173\" data-end=\"1228\"><strong data-start=\"1173\" data-end=\"1228\">Z\u00e1klady fungovania v\u00e1kuov\u00e9ho testera tesnosti pre obaly\u00a0<\/strong><\/h2>\n<p class=\"\" data-start=\"1230\" data-end=\"1607\">Str\u00e1nka <strong data-start=\"1234\" data-end=\"1271\">pr\u00edstroj na testovanie tesnosti v\u00e1kuov\u00fdch obalov <\/strong>je ur\u010den\u00fd na detekciu netesnost\u00ed v hermeticky uzavret\u00fdch flexibiln\u00fdch obaloch prostredn\u00edctvom pozorovania \u00faniku vzduchu alebo plynu pri vytvoren\u00ed v\u00e1kua. T\u00e1to technika je zalo\u017een\u00e1 na <strong data-start=\"1410\" data-end=\"1435\">diferenci\u00e1lny tlak<\/strong>, kde tlak vo vn\u00fatri obalu kontrastuje s v\u00e1kuov\u00fdm prostred\u00edm v komore. Ak doch\u00e1dza k \u00faniku, vzduch alebo v\u00fdpary z produktu unikaj\u00fa vo forme vidite\u013en\u00e9ho pr\u00fadu bubl\u00edn.<\/p>\n<p class=\"\" data-start=\"1609\" data-end=\"1973\">Cell Instruments\u2019 <strong data-start=\"1627\" data-end=\"1648\">Tester tesnosti LT-01<\/strong> pon\u00faka spo\u013eahliv\u00fd a ekonomick\u00fd sp\u00f4sob vykonania tohto postupu. Vyu\u017e\u00edva <strong data-start=\"1728\" data-end=\"1744\">Venturiho trubica<\/strong> na vytvorenie v\u00e1kua a\u017e do \u201390 kPa, \u010do umo\u017e\u0148uje stabiln\u00e9 a nastavite\u013en\u00e9 v\u00e1kuov\u00e9 podmienky bez potreby elektrick\u00e9ho zdroja. Okrem toho poskytuje <strong data-start=\"1897\" data-end=\"1929\">akrylov\u00e1 komora s mo\u017enos\u0165ou prisp\u00f4sobenia<\/strong> tak, aby vyhovovali r\u00f4znym ve\u013ekostiam a tvarom obalov.<\/p>\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"V\u00e1kuov\u00e9 tesnostn\u00e9 testery Cell INSTRUMENTS v troch modeloch\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/UcL0JjOEm04?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<hr class=\"\" data-start=\"1975\" data-end=\"1978\" \/>\n<h2 data-start=\"1980\" data-end=\"2027\"><strong data-start=\"1980\" data-end=\"2027\">Met\u00f3da v\u00e1kuovej sk\u00fa\u0161ky tesnosti pod\u013ea normy ASTM a s\u00falad s \u0148ou<\/strong><\/h2>\n<p class=\"\" data-start=\"2029\" data-end=\"2304\">Aby sa zabezpe\u010dili konzistentn\u00e9 a presn\u00e9 v\u00fdsledky, zariadenie na testovanie tesnosti vo v\u00e1kuu by malo sp\u013a\u0148a\u0165 po\u017eiadavky <strong data-start=\"2118\" data-end=\"2143\">V\u00e1kuov\u00e1 sk\u00fa\u0161ka tesnosti pod\u013ea normy ASTM<\/strong> met\u00f3da op\u00edsan\u00e1 v <a href=\"https:\/\/www.qualitester.com\/sk\/standards\/astm-d3078\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"2163\" data-end=\"2177\">ASTM D3078<\/strong><\/a>. T\u00e1to medzin\u00e1rodn\u00e1 norma stanovuje, ako vykon\u00e1va\u0165 detekciu \u00faniku prostredn\u00edctvom <strong data-start=\"2253\" data-end=\"2280\">sk\u00fa\u0161ky emisi\u00ed bubl\u00edn<\/strong> pre flexibiln\u00e9 obaly.<\/p>\n<p class=\"\" data-start=\"2306\" data-end=\"2364\">Pod\u013ea <strong data-start=\"2319\" data-end=\"2333\">ASTM D3078<\/strong>, a takto cel\u00fd proces prebieha:<\/p>\n<ul data-start=\"2366\" data-end=\"2855\">\n<li class=\"\" data-start=\"2366\" data-end=\"2442\">\n<p class=\"\" data-start=\"2368\" data-end=\"2442\">Bal\u00edk je ponoren\u00fd do vody vo vn\u00fatri <strong data-start=\"2411\" data-end=\"2441\">prieh\u013eadn\u00e1 v\u00e1kuov\u00e1 komora<\/strong>.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2443\" data-end=\"2547\">\n<p class=\"\" data-start=\"2445\" data-end=\"2547\">Vytv\u00e1ra sa podtlak, ktor\u00fd sa zvy\u010dajne zvy\u0161uje r\u00fdchlos\u0165ou 1 in. Hg\/s, a\u017e k\u00fdm sa nedosiahne cie\u013eov\u00e1 \u00farove\u0148.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2548\" data-end=\"2630\">\n<p class=\"\" data-start=\"2550\" data-end=\"2630\">Ako tlak kles\u00e1, <strong data-start=\"2573\" data-end=\"2629\">ak\u00fdko\u013evek \u00fanik sa prejavuje ako nepretr\u017eit\u00fd pr\u00fad bubl\u00edn<\/strong>.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2631\" data-end=\"2755\">\n<p class=\"\" data-start=\"2633\" data-end=\"2755\">V\u00e1kuum sa udr\u017eiava po\u010das stanoven\u00e9ho \u010dasu (zvy\u010dajne 30 sek\u00fand), po uplynut\u00ed ktor\u00e9ho sa obal skontroluje, \u010di do neho neprenikla testovacia kvapalina.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2756\" data-end=\"2855\">\n<p class=\"\" data-start=\"2758\" data-end=\"2855\">Bal\u00ed\u010dky, z ktor\u00fdch unikaj\u00fa bubliny alebo ktor\u00e9 vykazuj\u00fa zn\u00e1mky vn\u00fatornej kontamin\u00e1cie tekutinou, sa pova\u017euj\u00fa za po\u0161koden\u00e9.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"2857\" data-end=\"3010\">T\u00e1to met\u00f3da je \u00fa\u010dinn\u00e1 pri identifik\u00e1cii mal\u00fdch dierok, slab\u00fdch tesnen\u00ed alebo nespr\u00e1vneho uzavretia, ktor\u00e9 by mohli sp\u00f4sobi\u0165 vniknutie vzduchu, vlhkosti alebo ne\u010dist\u00f4t do obalu.<\/p>\n<hr class=\"\" data-start=\"3012\" data-end=\"3015\" \/>\n<h2 data-start=\"3017\" data-end=\"3061\"><strong data-start=\"3017\" data-end=\"3061\">K\u013e\u00fa\u010dov\u00e9 vlastnosti v\u00e1kuov\u00e9ho testeru tesnosti LT-01<\/strong><\/h2>\n<p class=\"\" data-start=\"3063\" data-end=\"3232\">Str\u00e1nka <strong data-start=\"3067\" data-end=\"3088\">Tester tesnosti LT-01<\/strong> od spolo\u010dnosti Cell Instruments je navrhnut\u00fd tak, aby zjednodu\u0161il detekciu netesnost\u00ed a z\u00e1rove\u0148 poskytoval <strong data-start=\"3166\" data-end=\"3194\">presnos\u0165 a odolnos\u0165<\/strong>. Ni\u017e\u0161ie uv\u00e1dzame niektor\u00e9 z jeho hlavn\u00fdch vlastnost\u00ed:<\/p>\n<ul data-start=\"3234\" data-end=\"3668\">\n<li class=\"\" data-start=\"3234\" data-end=\"3310\">\n<p class=\"\" data-start=\"3236\" data-end=\"3310\"><strong data-start=\"3236\" data-end=\"3252\">Ru\u010dn\u00fd model<\/strong>: Navrhnut\u00e9 s oh\u013eadom na jednoduchos\u0165 a n\u00edzkon\u00e1kladov\u00e9 testovanie.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3311\" data-end=\"3374\">\n<p class=\"\" data-start=\"3313\" data-end=\"3374\"><strong data-start=\"3313\" data-end=\"3329\">Rozsah v\u00e1kua<\/strong>: 0 a\u017e \u201390 kPa, nastavite\u013en\u00e9 pomocou regul\u00e1tora tlaku vzduchu.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3375\" data-end=\"3470\">\n<p class=\"\" data-start=\"3377\" data-end=\"3470\"><strong data-start=\"3377\" data-end=\"3410\">Vytv\u00e1ranie v\u00e1kua pomocou Venturiho efektu<\/strong>: V\u010faka vyu\u017eitiu stla\u010den\u00e9ho vzduchu nie je potrebn\u00e1 elektrick\u00e1 energia.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3471\" data-end=\"3553\">\n<p class=\"\" data-start=\"3473\" data-end=\"3553\"><strong data-start=\"3473\" data-end=\"3503\">Pevn\u00e1 prieh\u013eadn\u00e1 komora<\/strong>: Jednoduch\u00e9 vizu\u00e1lne sledovanie a odoln\u00e1 kon\u0161trukcia.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3554\" data-end=\"3668\">\n<p class=\"\" data-start=\"3556\" data-end=\"3668\"><strong data-start=\"3556\" data-end=\"3580\">Rozmery kom\u00f4r na mieru<\/strong>: K dispoz\u00edcii vo valcovom alebo kv\u00e1drovom tvare, aby vyhovovali \u0161irokej \u0161k\u00e1le typov obalov.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"3670\" data-end=\"3829\">Okrem toho je mo\u017en\u00e9 model LT-01 vybavi\u0165 <strong data-start=\"3713\" data-end=\"3728\">v\u00e1kuov\u00e1 pumpa<\/strong> aby sp\u013a\u0148ali pr\u00edsnej\u0161ie sk\u00fa\u0161obn\u00e9 met\u00f3dy, ako napr\u00edklad <strong data-start=\"3770\" data-end=\"3784\">ASTM D4991<\/strong>, \u010d\u00edm \u010falej roz\u0161iruje svoje testovacie kapacity.<\/p>\n<hr class=\"\" data-start=\"4580\" data-end=\"4583\" \/>\n<h2 data-start=\"4585\" data-end=\"4637\"><strong data-start=\"4585\" data-end=\"4637\">Vyu\u017eitie v\u00e1kuov\u00e9ho testeru tesnosti pre <\/strong><strong data-start=\"1173\" data-end=\"1228\">Kontajnery<\/strong><\/h2>\n<p class=\"\" data-start=\"4639\" data-end=\"4730\">Str\u00e1nka <strong data-start=\"4643\" data-end=\"4679\">pr\u00edstroj na testovanie tesnosti podtlakom pre c<\/strong><strong data-start=\"1173\" data-end=\"1228\">kontajnery <\/strong>sa \u0161iroko vyu\u017e\u00edva v r\u00f4znych odvetviach, napr\u00edklad:<\/p>\n<ul data-start=\"4732\" data-end=\"5065\">\n<li class=\"\" data-start=\"4732\" data-end=\"4823\">\n<p class=\"\" data-start=\"4734\" data-end=\"4823\"><strong data-start=\"4734\" data-end=\"4753\">Potraviny a n\u00e1poje<\/strong>: Na kontrolu tesnosti vrec\u00fa\u0161ok, s\u00e1\u010dkov a pru\u017en\u00fdch f\u00f3li\u00ed.<\/p>\n<\/li>\n<li class=\"\" data-start=\"4824\" data-end=\"4902\">\n<p class=\"\" data-start=\"4826\" data-end=\"4902\"><strong data-start=\"4826\" data-end=\"4845\">Farmaceutick\u00e9 v\u00fdrobky<\/strong>: Aby sa zabezpe\u010dilo, \u017ee steriln\u00e9 bari\u00e9rov\u00e9 syst\u00e9my zostan\u00fa neporu\u0161en\u00e9.<\/p>\n<\/li>\n<li class=\"\" data-start=\"4903\" data-end=\"4983\">\n<p class=\"\" data-start=\"4905\" data-end=\"4983\"><strong data-start=\"4905\" data-end=\"4924\">Zdravotn\u00edcke pom\u00f4cky<\/strong>: Na detekciu netesnost\u00ed v steriln\u00fdch obaloch a baleniach komponentov.<\/p>\n<\/li>\n<li class=\"\" data-start=\"4984\" data-end=\"5065\">\n<p class=\"\" data-start=\"4986\" data-end=\"5065\"><strong data-start=\"4986\" data-end=\"5013\">Elektronika a chemik\u00e1lie<\/strong>: Na zachovanie vlastnost\u00ed vlhkostnej a paroz\u00e1brany.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"5067\" data-end=\"5190\">Spo\u013eahliv\u00e1 detekcia \u00fanikov je nevyhnutn\u00e1 pre <strong data-start=\"5108\" data-end=\"5154\">predch\u00e1dzanie stiahnutiu v\u00fdrobkov z trhu, zni\u017eovanie mno\u017estva odpadu<\/strong>, a zlep\u0161ovanie <strong data-start=\"5170\" data-end=\"5189\">bezpe\u010dnos\u0165 spotrebite\u013eov<\/strong>.<\/p>\n<hr class=\"\" data-start=\"3831\" data-end=\"3834\" \/>\n<h2 data-start=\"3836\" data-end=\"3896\"><strong data-start=\"3836\" data-end=\"3896\">Pre\u010do si vybra\u0165 v\u00e1kuov\u00fd tester tesnosti od spolo\u010dnosti Cell Instruments<\/strong><\/h2>\n<p class=\"\" data-start=\"3898\" data-end=\"4002\">V\u00fdber <strong data-start=\"3909\" data-end=\"3934\">pr\u00edstroj na meranie \u00faniku vo v\u00e1kuu<\/strong> od spolo\u010dnosti Cell Instruments pon\u00faka v\u00fdhody, ktor\u00e9 presahuj\u00fa r\u00e1mec splnenia \u0161tandardov:<\/p>\n<ul data-start=\"4004\" data-end=\"4429\">\n<li class=\"\" data-start=\"4004\" data-end=\"4093\">\n<p class=\"\" data-start=\"4006\" data-end=\"4093\"><strong data-start=\"4006\" data-end=\"4032\">Rie\u0161enia na mieru<\/strong>: Komory a zostavy prisp\u00f4soben\u00e9 r\u00f4znym form\u00e1tom balenia.<\/p>\n<\/li>\n<li class=\"\" data-start=\"4094\" data-end=\"4204\">\n<p class=\"\" data-start=\"4096\" data-end=\"4204\"><strong data-start=\"4096\" data-end=\"4130\">Podpora viacer\u00fdch \u0161tandardov<\/strong>: Okrem toho <a href=\"https:\/\/www.astm.org\/d3078-02r21e01.html\" target=\"_blank\" rel=\"noopener nofollow\">ASTM D3078<\/a>, jednotky je mo\u017en\u00e9 prisp\u00f4sobi\u0165 pre <a href=\"https:\/\/www.astm.org\/d4991-07r15.html\" target=\"_blank\" rel=\"noopener nofollow\">ASTM D4991<\/a> a \u010fal\u0161ie.<\/p>\n<\/li>\n<li class=\"\" data-start=\"4205\" data-end=\"4330\">\n<p class=\"\" data-start=\"4207\" data-end=\"4330\"><strong data-start=\"4207\" data-end=\"4229\">Odborn\u00e9 znalosti v danom odvetv\u00ed<\/strong>: Preuk\u00e1zate\u013en\u00e9 sk\u00fasenosti v oblasti <strong data-start=\"4252\" data-end=\"4329\">testovanie obalov v oblasti zdravotn\u00edctva, potravin\u00e1rstva, farmaceutick\u00e9ho priemyslu, lepidiel a elektroniky<\/strong>.<\/p>\n<\/li>\n<li class=\"\" data-start=\"4331\" data-end=\"4429\">\n<p class=\"\" data-start=\"4333\" data-end=\"4429\"><strong data-start=\"4333\" data-end=\"4360\">Nie je potrebn\u00e1 elektrick\u00e1 energia<\/strong>: \u0160etrn\u00e9 k \u017eivotn\u00e9mu prostrediu a bezpe\u010dnej\u0161ie v r\u00f4znych v\u00fdrobn\u00fdch prostrediach.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"4431\" data-end=\"4578\">V\u010faka t\u00fdmto v\u00fdhod\u00e1m je model LT-01 vynikaj\u00facou vo\u013ebou pre spolo\u010dnosti, ktor\u00e9 sa sna\u017eia zlep\u0161i\u0165 <strong data-start=\"4514\" data-end=\"4543\">zabezpe\u010denie kvality balenia<\/strong> a stretn\u00fa\u0165 sa <strong data-start=\"4553\" data-end=\"4577\">regula\u010dn\u00e9 normy<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p class=\"\" data-start=\"473\" data-end=\"983\">Zabezpe\u010denie integrity obalu m\u00e1 k\u013e\u00fa\u010dov\u00fd v\u00fdznam pre zachovanie bezpe\u010dnosti v\u00fdrobku, pred\u013a\u017eenie doby trvanlivosti a dodr\u017eiavanie medzin\u00e1rodn\u00fdch noriem. Jedn\u00fdm z naj\u00fa\u010dinnej\u0161\u00edch a najroz\u0161\u00edrenej\u0161\u00edch n\u00e1strojov na tento \u00fa\u010del je <strong data-start=\"694\" data-end=\"730\">pr\u00edstroj na testovanie tesnosti v\u00e1kuov\u00fdch obalov<\/strong>. Tento testovac\u00ed pr\u00edstroj, ktor\u00fd sa pou\u017e\u00edva v r\u00f4znych odvetviach, ako s\u00fa potravin\u00e1rstvo, zdravotn\u00edctvo, farmaceutick\u00fd priemysel, elektronika a kontrola kvality, hodnot\u00ed pevnos\u0165 zvaru a tesnos\u0165 flexibiln\u00fdch obalov s cie\u013eom odhali\u0165 pr\u00edpadn\u00e9 netesnosti, ktor\u00e9 by mohli ohrozi\u0165 kvalitu v\u00fdrobku.<\/p>\n<p class=\"\" data-start=\"985\" data-end=\"1166\">Pozrime sa, ako tento n\u00e1stroj funguje a ak\u00fd m\u00e1 v\u00fdznam pre glob\u00e1lne \u0161tandardy, ako napr\u00edklad <strong data-start=\"1068\" data-end=\"1082\">ASTM D3078<\/strong>, a pre\u010do je model LT-01 spolo\u010dnosti Cell Instruments ide\u00e1lnym rie\u0161en\u00edm pre va\u0161e testovacie potreby.<\/p>","protected":false},"featured_media":5980,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":""},"product_cat":[845,675,17,149,16,105,135,95],"product_tag":[],"class_list":["post-2268","product","type-product","status-publish","has-post-thumbnail","product_cat-customization","product_cat-leak-tester","product_cat-package-container-testers","product_cat-pharma-and-medical-testers","product_cat-plastic-packaging-testers","product_cat-astm-d3078","product_cat-astm-d4991","product_cat-products","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/product\/2268","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/comments?post=2268"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/product\/2268\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/media\/5980"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/media?parent=2268"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/product_cat?post=2268"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/product_tag?post=2268"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}