{"id":7246,"date":"2025-07-30T09:01:04","date_gmt":"2025-07-30T01:01:04","guid":{"rendered":"https:\/\/www.qualitester.com\/?p=7246"},"modified":"2025-07-30T09:08:41","modified_gmt":"2025-07-30T01:08:41","slug":"tablet-hardness-test","status":"publish","type":"post","link":"https:\/\/www.qualitester.com\/sk\/tablet-hardness-test\/","title":{"rendered":"Test tvrdosti tabliet"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"211\" data-end=\"282\">Test tvrdosti tabliet<\/h1>\n<h2 data-start=\"284\" data-end=\"323\"><\/h2>\n<p data-start=\"325\" data-end=\"725\">Str\u00e1nka <strong data-start=\"329\" data-end=\"353\">test tvrdosti tabliet<\/strong> je z\u00e1kladn\u00fd postup kontroly kvality pou\u017e\u00edvan\u00fd vo farmaceutickom priemysle na ur\u010denie mechanickej pevnosti tabliet. Zabezpe\u010duje, aby si tablety zachovali svoju \u0161truktur\u00e1lnu integritu po\u010das v\u00fdroby, balenia, prepravy a pou\u017e\u00edvania. Nedostato\u010dn\u00e1 tvrdos\u0165 m\u00f4\u017ee vies\u0165 k rozpadu alebo rozbitiu, zatia\u013e \u010do nadmern\u00e1 tvrdos\u0165 m\u00f4\u017ee zhor\u0161i\u0165 rozpad a biologick\u00fa dostupnos\u0165.<\/p>\n<p data-start=\"727\" data-end=\"1041\">V\u00fdrobcovia liekov sa spoliehaj\u00fa na tento test, aby splnili regula\u010dn\u00e9 po\u017eiadavky a zabezpe\u010dili konzistentn\u00fa \u00fa\u010dinnos\u0165 liekov. Na str\u00e1nke <strong data-start=\"856\" data-end=\"876\">Mobiln\u00e9 n\u00e1stroje<\/strong>, podporujeme laborat\u00f3ri\u00e1 a v\u00fdrobn\u00e9 prostredia pomocou pokro\u010dil\u00fdch rie\u0161en\u00ed, ako je napr. <a href=\"https:\/\/www.tablethardness.com\/\" target=\"_blank\" rel=\"noopener nofollow\"><strong data-start=\"963\" data-end=\"996\">MPT-02 Tester tvrdosti tabliet<\/strong><\/a> zefekt\u00edvni\u0165 tento kritick\u00fd proces testovania.<\/p>\n<hr data-start=\"1043\" data-end=\"1046\" \/>\n<h2 data-start=\"1048\" data-end=\"1098\">\u00daloha testu stla\u010denia pri tvrdosti tabliet<\/h2>\n<p data-start=\"1100\" data-end=\"1385\">A <strong data-start=\"1102\" data-end=\"1122\">kompresn\u00fd test<\/strong> meria silu potrebn\u00fa na zlomenie alebo deform\u00e1ciu tablety. Pri testovan\u00ed tabliet sa be\u017ene ozna\u010duje ako <strong data-start=\"1233\" data-end=\"1263\">test sily l\u00e1mania tabliet<\/strong>. Pon\u00faka poh\u013ead na mechanick\u00fa odolnos\u0165 tablety a odha\u013euje potenci\u00e1lne probl\u00e9my so zlo\u017een\u00edm alebo v\u00fdrobou.<\/p>\n<p data-start=\"1387\" data-end=\"1624\">Ak je tvrdos\u0165 pr\u00edli\u0161 n\u00edzka, tablety sa m\u00f4\u017eu zlomi\u0165 u\u017e pri minim\u00e1lnom nam\u00e1han\u00ed, napr\u00edklad pri plnen\u00ed f\u013ea\u0161e alebo pri manipul\u00e1cii s pacientom. Naopak, pr\u00edli\u0161 tvrd\u00e9 tablety m\u00f4\u017eu odol\u00e1va\u0165 potrebn\u00e9mu rozpadu v gastrointestin\u00e1lnom trakte, \u010do ovplyv\u0148uje uvo\u013e\u0148ovanie lie\u010diva.<\/p>\n<p data-start=\"1626\" data-end=\"1693\"><strong data-start=\"1626\" data-end=\"1692\">K\u013e\u00fa\u010dov\u00e9 parametre posudzovan\u00e9 po\u010das testovania tvrdosti tabliet zah\u0155\u0148aj\u00fa<\/strong>:<\/p>\n<ul data-start=\"1694\" data-end=\"1842\">\n<li data-start=\"1694\" data-end=\"1757\">\n<p data-start=\"1696\" data-end=\"1757\">Maxim\u00e1lna sila potrebn\u00e1 na rozdrvenie tablety (zvy\u010dajne v newtonoch)<\/p>\n<\/li>\n<li data-start=\"1758\" data-end=\"1797\">\n<p data-start=\"1760\" data-end=\"1797\">Posunutie v mieste zlomu<\/p>\n<\/li>\n<li data-start=\"1798\" data-end=\"1842\">\n<p data-start=\"1800\" data-end=\"1842\">Charakteristiky testovacej r\u00fdchlosti a silovej krivky<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"1844\" data-end=\"1847\" \/>\n<h2 data-start=\"1849\" data-end=\"1913\">V\u00fdznam tvrdosti tabliet pri v\u00fdrobe liekov<\/h2>\n<p data-start=\"1915\" data-end=\"1952\"><strong data-start=\"1915\" data-end=\"1934\">Tvrdos\u0165 tabliet<\/strong> priamo ovplyv\u0148uje:<\/p>\n<ul data-start=\"1953\" data-end=\"2118\">\n<li data-start=\"1953\" data-end=\"1990\">\n<p data-start=\"1955\" data-end=\"1990\"><strong data-start=\"1955\" data-end=\"1990\">Konzistentnos\u0165 a kvalita v\u00fdrobkov<\/strong><\/p>\n<\/li>\n<li data-start=\"1991\" data-end=\"2033\">\n<p data-start=\"1993\" data-end=\"2033\"><strong data-start=\"1993\" data-end=\"2033\">R\u00fdchlos\u0165 dezintegr\u00e1cie a rozp\u00fa\u0161\u0165ania<\/strong><\/p>\n<\/li>\n<li data-start=\"2034\" data-end=\"2071\">\n<p data-start=\"2036\" data-end=\"2071\"><strong data-start=\"2036\" data-end=\"2071\">Trvanlivos\u0165 a bezpe\u010dnos\u0165 pri preprave<\/strong><\/p>\n<\/li>\n<li data-start=\"2072\" data-end=\"2118\">\n<p data-start=\"2074\" data-end=\"2118\"><strong data-start=\"2074\" data-end=\"2118\">Dodr\u017eiavanie pr\u00e1vnych predpisov a bezpe\u010dnos\u0165 pacientov<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2120\" data-end=\"2334\">Pod\u013ea <strong data-start=\"2133\" data-end=\"2147\">USP<\/strong> a \u010fal\u0161\u00edch liekopisn\u00fdch noriem, pravideln\u00e9 testovanie tvrdosti pom\u00e1ha v\u00fdrobcom udr\u017eiava\u0165 kontrolu procesu a identifikova\u0165 probl\u00e9my, ako je nekonzistentnos\u0165 granul\u00e1cie alebo nespr\u00e1vna sila stla\u010denia.<\/p>\n<hr data-start=\"2336\" data-end=\"2339\" \/>\n<h2 data-start=\"2341\" data-end=\"2384\">Zariadenia na testovanie tvrdosti<\/h2>\n<figure id=\"attachment_7247\" aria-describedby=\"caption-attachment-7247\" style=\"width: 333px\" class=\"wp-caption alignright\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-7247\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/tablet-hardness-tester-1_-300x300.webp\" alt=\"test tvrdosti tabliet pomocou testera tvrdosti tabliet.\" width=\"333\" height=\"333\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/tablet-hardness-tester-1_-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/tablet-hardness-tester-1_-1024x1024.webp 1024w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/tablet-hardness-tester-1_-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/tablet-hardness-tester-1_-768x768.webp 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/tablet-hardness-tester-1_-1536x1536.webp 1536w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/tablet-hardness-tester-1_-2048x2048.webp 2048w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/tablet-hardness-tester-1_-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/tablet-hardness-tester-1_-600x600.webp 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/tablet-hardness-tester-1_-100x100.webp 100w\" sizes=\"(max-width: 333px) 100vw, 333px\" \/><figcaption id=\"caption-attachment-7247\" class=\"wp-caption-text\">\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Tester tvrdosti tabliet<\/figcaption><\/figure>\n<p data-start=\"2386\" data-end=\"2615\">Spo\u013eahliv\u00fd <strong data-start=\"2397\" data-end=\"2423\">tester tvrdosti tabliet<\/strong> mus\u00ed pon\u00faka\u0165 presnos\u0165, opakovate\u013enos\u0165 a u\u017e\u00edvate\u013esky pr\u00edvetiv\u00fa obsluhu. Str\u00e1nka <a href=\"https:\/\/www.tablethardness.com\/\" target=\"_blank\" rel=\"nofollow noopener\"><strong data-start=\"2494\" data-end=\"2527\">MPT-02 Tester tvrdosti tabliet<\/strong> <\/a>od spolo\u010dnosti Cell Instruments je navrhnut\u00fd tak, aby sp\u013a\u0148al tieto krit\u00e9ri\u00e1 s nasleduj\u00facimi v\u00fdhodami:<\/p>\n<ul data-start=\"2617\" data-end=\"2964\">\n<li data-start=\"2617\" data-end=\"2677\">\n<p data-start=\"2619\" data-end=\"2677\"><strong data-start=\"2619\" data-end=\"2636\">Vysok\u00e1 presnos\u0165<\/strong> (0,5% F.S.) a <strong data-start=\"2653\" data-end=\"2677\">rozl\u00ed\u0161enie 0,01 mm<\/strong><\/p>\n<\/li>\n<li data-start=\"2678\" data-end=\"2728\">\n<p data-start=\"2680\" data-end=\"2728\"><strong data-start=\"2680\" data-end=\"2706\">7-palcov\u00fd dotykov\u00fd displej HMI<\/strong> na intuit\u00edvne ovl\u00e1danie<\/p>\n<\/li>\n<li data-start=\"2729\" data-end=\"2786\">\n<p data-start=\"2731\" data-end=\"2786\"><strong data-start=\"2731\" data-end=\"2758\">Zobrazenie sily v re\u00e1lnom \u010dase<\/strong> na dynamick\u00e9 monitorovanie \u00fadajov<\/p>\n<\/li>\n<li data-start=\"2787\" data-end=\"2831\">\n<p data-start=\"2789\" data-end=\"2831\"><strong data-start=\"2789\" data-end=\"2814\">Nastavite\u013en\u00e1 r\u00fdchlos\u0165 testu<\/strong> do 500 mm\/min<\/p>\n<\/li>\n<li data-start=\"2832\" data-end=\"2898\">\n<p data-start=\"2834\" data-end=\"2898\"><strong data-start=\"2834\" data-end=\"2859\">Zabudovan\u00e1 mikrotla\u010diare\u0148<\/strong> a volite\u013en\u00fd softv\u00e9r na sledovanie<\/p>\n<\/li>\n<li data-start=\"2899\" data-end=\"2964\">\n<p data-start=\"2901\" data-end=\"2964\"><strong data-start=\"2901\" data-end=\"2922\">Viacero pr\u00edslu\u0161enstva<\/strong> pre r\u00f4zne tvary a sily tabliet<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2966\" data-end=\"3134\">Tento tester podporuje oba <strong data-start=\"2992\" data-end=\"3020\">met\u00f3da pevnosti v tlaku<\/strong> a <strong data-start=\"3025\" data-end=\"3053\">met\u00f3da h\u013abky vtla\u010dku<\/strong>, \u010do umo\u017e\u0148uje komplexn\u00e9 pos\u00fadenie na z\u00e1klade po\u017eiadaviek na v\u00fdrobok a pr\u00e1vnych predpisov.<\/p>\n<hr data-start=\"3136\" data-end=\"3139\" \/>\n<h2 data-start=\"3141\" data-end=\"3186\">Porovnanie s in\u00fdmi testami pevnosti tabliet<\/h2>\n<p data-start=\"3188\" data-end=\"3280\">Okrem testu tvrdosti tabliet sa kvalita tabliet hodnot\u00ed aj nieko\u013ek\u00fdmi \u010fal\u0161\u00edmi mechanick\u00fdmi testami:<\/p>\n<h3 data-start=\"3282\" data-end=\"3301\">Sk\u00fa\u0161ka drobivosti<\/h3>\n<p data-start=\"3303\" data-end=\"3514\">Str\u00e1nka <strong data-start=\"3307\" data-end=\"3326\">sk\u00fa\u0161ka drobivosti<\/strong> ur\u010duje, ako \u013eahko sa tableta rozpadne pri mechanickom nam\u00e1han\u00ed, simuluj\u00fac manipul\u00e1ciu a prepravu. K\u00fdm tvrdos\u0165 meria silu l\u00e1mania, drobivos\u0165 odr\u00e1\u017ea odolnos\u0165 vo\u010di opotrebovaniu povrchu.<\/p>\n<h3 data-start=\"3516\" data-end=\"3544\">Sk\u00fa\u0161ka trojbodov\u00fdm ohybom<\/h3>\n<p data-start=\"3546\" data-end=\"3737\">Pou\u017e\u00edva sa v \u0161peci\u00e1lnych pr\u00edpadoch. <strong data-start=\"3573\" data-end=\"3601\">trojbodov\u00e1 sk\u00fa\u0161ka ohybom<\/strong> p\u00f4sob\u00ed sila v strede dosky podopretej na oboch koncoch. Vyhodnocuje sa <strong data-start=\"3679\" data-end=\"3698\">sila tablety<\/strong> v ohybn\u00fdch alebo podlhovast\u00fdch liekov\u00fdch form\u00e1ch.<\/p>\n<hr data-start=\"3739\" data-end=\"3742\" \/>\n<h2 data-start=\"3744\" data-end=\"3793\">Ako vykona\u0165 \u0161tandardn\u00fd test tvrdosti tabliet<\/h2>\n<p data-start=\"3795\" data-end=\"3880\"><strong data-start=\"3795\" data-end=\"3817\">Sprievodca krok za krokom<\/strong> na vykonanie sk\u00fa\u0161ky tvrdosti pomocou MPT-02 alebo podobn\u00fdch zariaden\u00ed:<\/p>\n<ol data-start=\"3882\" data-end=\"4243\">\n<li data-start=\"3882\" data-end=\"3952\">\n<p data-start=\"3885\" data-end=\"3952\"><strong data-start=\"3885\" data-end=\"3900\">Pr\u00edprava<\/strong>: Vyberte reprezentat\u00edvne vzorky tabliet zo \u0161ar\u017ee.<\/p>\n<\/li>\n<li data-start=\"3953\" data-end=\"4020\">\n<p data-start=\"3956\" data-end=\"4020\"><strong data-start=\"3956\" data-end=\"3965\">Nastavenie<\/strong>: Umiestnite tabletu vodorovne medzi lisovacie \u010de\u013euste.<\/p>\n<\/li>\n<li data-start=\"4021\" data-end=\"4082\">\n<p data-start=\"4024\" data-end=\"4082\"><strong data-start=\"4024\" data-end=\"4035\">Testovanie<\/strong>: P\u00f4sobte stl\u00e1\u010dacou silou rovnomernou r\u00fdchlos\u0165ou.<\/p>\n<\/li>\n<li data-start=\"4083\" data-end=\"4154\">\n<p data-start=\"4086\" data-end=\"4154\"><strong data-start=\"4086\" data-end=\"4105\">Zber \u00fadajov<\/strong>: Zaznamenajte silu, pri ktorej sa tableta zlom\u00ed.<\/p>\n<\/li>\n<li data-start=\"4155\" data-end=\"4243\">\n<p data-start=\"4158\" data-end=\"4243\"><strong data-start=\"4158\" data-end=\"4170\">Anal\u00fdza<\/strong>: Porovnajte nameran\u00e9 hodnoty so \u0161pecifik\u00e1ciami v\u00fdrobku a regula\u010dn\u00fdmi limitmi.<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"4245\" data-end=\"4340\">Na zachovanie presnosti merania a zhody je nevyhnutn\u00e9 zariadenie pravidelne kalibrova\u0165.<\/p>\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Testovanie tvrdosti tabliet Sk\u00fa\u0161ka tvrdosti v tlaku pre tablety liekov\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/uYgafVVSvpY?start=1&#038;feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<hr data-start=\"4342\" data-end=\"4345\" \/>\n<h2 data-start=\"4347\" data-end=\"4386\">Dodr\u017eiavanie regula\u010dn\u00fdch noriem<\/h2>\n<p data-start=\"4388\" data-end=\"4456\">Testovanie tvrdosti tabliet je v s\u00falade s medzin\u00e1rodn\u00fdmi normami, ako s\u00fa:<\/p>\n<ul data-start=\"4457\" data-end=\"4602\">\n<li data-start=\"4457\" data-end=\"4496\">\n<p data-start=\"4459\" data-end=\"4496\"><strong data-start=\"4459\" data-end=\"4473\">USP<\/strong>: Sila l\u00e1mania tabletu<\/p>\n<\/li>\n<li data-start=\"4497\" data-end=\"4546\">\n<p data-start=\"4499\" data-end=\"4546\"><strong data-start=\"4499\" data-end=\"4511\">EP 2.9.8<\/strong>: Odolnos\u0165 tabliet vo\u010di rozdrveniu<\/p>\n<\/li>\n<li data-start=\"4497\" data-end=\"4546\">\n<p data-start=\"4499\" data-end=\"4546\"><span style=\"font-size: 16px;\">Pou\u017eitie \u0161tandardizovan\u00e9ho testera, ako je <\/span><strong style=\"font-size: 16px;\" data-start=\"4637\" data-end=\"4647\">MPT-02<\/strong><span style=\"font-size: 16px;\"> zabezpe\u010duje s\u00falad s t\u00fdmito regula\u010dn\u00fdmi r\u00e1mcami, \u010d\u00edm zvy\u0161uje pripravenos\u0165 na audit a d\u00f4veryhodnos\u0165 trhu.<\/span><\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"4757\" data-end=\"4760\" \/>\n<h2 data-start=\"4762\" data-end=\"4829\">Z\u00e1ver: Optimaliz\u00e1cia kvality liekov pomocou spr\u00e1vnych testovac\u00edch n\u00e1strojov<\/h2>\n<p data-start=\"4831\" data-end=\"5059\">Spr\u00e1vne vykonan\u00e1 <strong data-start=\"4851\" data-end=\"4875\">test tvrdosti tabliet<\/strong> zohr\u00e1va d\u00f4le\u017eit\u00fa \u00falohu pri zabezpe\u010dovan\u00ed \u00fa\u010dinnosti liekov, bezpe\u010dnosti pacientov a dodr\u017eiavania pr\u00e1vnych predpisov. Umo\u017e\u0148uje farmaceutick\u00fdm odborn\u00edkom optimalizova\u0165 zlo\u017eenie a v\u00fdrobn\u00e9 parametre.<\/p>\n<p data-start=\"5061\" data-end=\"5280\">Na str\u00e1nke <strong data-start=\"5064\" data-end=\"5084\">Mobiln\u00e9 n\u00e1stroje<\/strong>, uvedomujeme si, ak\u00fa d\u00f4le\u017eit\u00fa \u00falohu tento test zohr\u00e1va. Na\u0161e str\u00e1nky <a href=\"https:\/\/www.qualitester.com\/sk\/produkt-2\/sale-hardness-test-apparatus-for-tablet\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5139\" data-end=\"5172\">MPT-02 <\/strong><\/a>poskytuje farmaceutick\u00fdm v\u00fdrobcom presnos\u0165 a spo\u013eahlivos\u0165 potrebn\u00fa pre modern\u00fa kontrolu kvality.<\/p>\n<p data-start=\"5282\" data-end=\"5446\">Pre farmaceutick\u00e9 laborat\u00f3ri\u00e1, v\u00fdrobcov a t\u00edmy kontroly kvality, ktor\u00e9 sa sna\u017eia o presnos\u0165, zhodu a efekt\u00edvnos\u0165.<strong data-start=\"5393\" data-end=\"5445\">Cell Instruments je v\u00e1\u0161 d\u00f4veryhodn\u00fd partner pre testovanie<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Sk\u00fa\u0161ka tvrdosti tabliet Sk\u00fa\u0161ka tvrdosti tabliet je z\u00e1kladn\u00fd postup kontroly kvality pou\u017e\u00edvan\u00fd vo farmaceutickom priemysle na ur\u010denie mechanickej pevnosti tabliet. Zabezpe\u010duje, aby si tablety zachovali svoju \u0161truktur\u00e1lnu integritu po\u010das v\u00fdroby, balenia, prepravy a pou\u017e\u00edvania. Nedostato\u010dn\u00e1 tvrdos\u0165 m\u00f4\u017ee vies\u0165 k rozpadu alebo rozbitiu, zatia\u013e \u010do nadmern\u00e1 tvrdos\u0165 m\u00f4\u017ee zhor\u0161i\u0165 rozpad a biologick\u00fa dostupnos\u0165. ...<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/sk\/tablet-hardness-test\/\"> <span class=\"screen-reader-text\">Test tvrdosti tabliet<\/span> \u010c\u00edtajte viac \"<\/a><\/p>","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-7246","post","type-post","status-publish","format-standard","hentry","category-test-method"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/posts\/7246","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/comments?post=7246"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/posts\/7246\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/media?parent=7246"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/categories?post=7246"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.qualitester.com\/sk\/wp-json\/wp\/v2\/tags?post=7246"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}