{"id":7328,"date":"2025-07-31T13:49:15","date_gmt":"2025-07-31T05:49:15","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7328"},"modified":"2025-07-31T13:52:22","modified_gmt":"2025-07-31T05:52:22","slug":"usp-1217","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/ru\/standards\/usp-1217\/","title":{"rendered":"USP 1217"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"529\" data-end=\"1070\"><strong data-start=\"529\" data-end=\"599\">\u00a0USP 1217<\/strong><\/h1>\n<h2 style=\"text-align: center;\" data-start=\"529\" data-end=\"1070\"><strong data-start=\"529\" data-end=\"599\">The Standard for Tablet Strength Testing<\/strong><\/h2>\n<p data-start=\"529\" data-end=\"1070\"><br data-start=\"599\" data-end=\"602\" \/>In pharmaceutical production, <strong data-start=\"632\" data-end=\"652\">tablet integrity<\/strong> is not just about appearance\u2014it directly influences efficacy, stability, and patient experience. <strong data-start=\"750\" data-end=\"764\">USP<\/strong> establishes a comprehensive framework for evaluating tablet mechanical strength, focusing on <strong data-start=\"858\" data-end=\"877\">tablet hardness<\/strong>, <strong data-start=\"879\" data-end=\"897\">breaking force<\/strong>, and structural durability. These metrics guide formulation, inform quality control, and ensure tablets can withstand manufacturing and real-world handling without failure.<\/p>\n<p data-start=\"1072\" data-end=\"1318\">Modern instrumentation\u2014like Cell Instruments\u2019 <strong data-start=\"1118\" data-end=\"1151\">MPT-02 \u0422\u0435\u0441\u0442\u0435\u0440 \u0442\u0432\u0435\u0440\u0434\u043e\u0441\u0442\u0438 \u0442\u0430\u0431\u043b\u0435\u0442\u043e\u043a<\/strong>\u2014enables manufacturers to perform these tests with precision and repeatability, aligning with USP &lt;1217&gt; while supporting process efficiency and regulatory compliance.<\/p>\n<hr data-start=\"1320\" data-end=\"1323\" \/>\n<h2 data-start=\"1325\" data-end=\"1398\"><strong data-start=\"1325\" data-end=\"1396\">Critical Testing Protocols: From Tablet Hardness Test to Friability<\/strong><\/h2>\n<p>&nbsp;<\/p>\n<h3 data-start=\"1400\" data-end=\"1810\"><strong data-start=\"1400\" data-end=\"1467\">Tablet Hardness Test and Break Test: Why Breaking Force Matters<\/strong><\/h3>\n<h2 style=\"text-align: center;\" data-start=\"529\" data-end=\"1070\"><strong style=\"font-size: 27.2px;\" data-start=\"529\" data-end=\"599\"><img decoding=\"async\" class=\"wp-image-7332 alignright\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/usp1217-tablet-hardness_11zon-150x150.webp\" alt=\"USP 1217 with tablet hardness tester\" width=\"212\" height=\"212\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/usp1217-tablet-hardness_11zon-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/usp1217-tablet-hardness_11zon-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/usp1217-tablet-hardness_11zon-100x100.webp 100w\" sizes=\"(max-width: 212px) 100vw, 212px\" \/><\/strong><\/h2>\n<p data-start=\"1400\" data-end=\"1810\">The <strong data-start=\"1474\" data-end=\"1498\">\u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u0442\u0432\u0435\u0440\u0434\u043e\u0441\u0442\u044c \u0442\u0430\u0431\u043b\u0435\u0442\u043e\u043a<\/strong> isn&#8217;t simply about measuring surface resistance. In the context of USP &lt;1217&gt;, it refers to the <strong data-start=\"1595\" data-end=\"1609\">break test<\/strong>\u2014the compressive force needed to fracture a tablet. This force, also called the <strong data-start=\"1689\" data-end=\"1717\">tablet crushing strength<\/strong>, offers insights into internal bonding, compression uniformity, and formulation performance.<\/p>\n<p data-start=\"1812\" data-end=\"2215\">The <a href=\"https:\/\/www.qualitester.com\/ru\/tablet-hardness-test\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"1816\" data-end=\"1849\">MPT-02 \u0422\u0435\u0441\u0442\u0435\u0440 \u0442\u0432\u0435\u0440\u0434\u043e\u0441\u0442\u0438 \u0442\u0430\u0431\u043b\u0435\u0442\u043e\u043a<\/strong><\/a>, with a digital force sensor and constant platen movement, is tailored for such analysis. It records peak force applied to a sample placed between two platens, helping users determine if the tablet meets required strength standards. The test is especially important for chewable, coated, or scored tablets, where breakage can alter drug delivery or dosage accuracy.<\/p>\n<hr data-start=\"2217\" data-end=\"2220\" \/>\n<h2 data-start=\"2222\" data-end=\"2578\"><strong data-start=\"2222\" data-end=\"2288\">Friability of Tablet: Mechanical Robustness Beyond Compression\u00a0\u00a0<\/strong><\/h2>\n<p data-start=\"2222\" data-end=\"2578\"><br data-start=\"2288\" data-end=\"2291\" \/>While breaking force tests the resistance to direct pressure, <strong data-start=\"2353\" data-end=\"2373\">friability tests<\/strong> simulate abrasion and surface stress during handling. According to USP &lt;1216&gt;, which complements USP &lt;1217&gt;, tablets are tumbled inside a rotating drum to measure <strong data-start=\"2537\" data-end=\"2577\">weight loss from chipping or erosion<\/strong>.<\/p>\n<p data-start=\"2580\" data-end=\"2841\">Friability is critical when evaluating fragile formulations or tablets with surface coatings. Excessive friability suggests that a tablet might crumble during packaging, shipping, or administration. A <strong data-start=\"2781\" data-end=\"2814\">weight loss greater than 1.0%<\/strong> is typically unacceptable.<\/p>\n<p data-start=\"2843\" data-end=\"3138\">For manufacturers aiming to minimize friability issues, it&#8217;s crucial to adjust binder concentrations, optimize compression forces, or refine tablet shape. These adjustments should always be verified using <strong data-start=\"3048\" data-end=\"3078\">a calibrated tablet tester<\/strong> to prevent overcorrection that might hinder disintegration.<\/p>\n<hr data-start=\"3140\" data-end=\"3143\" \/>\n<h2 data-start=\"3145\" data-end=\"3595\"><strong data-start=\"3145\" data-end=\"3218\">Flexure Test and Tablet Brittleness Test: Advanced Structural Insight<\/strong><\/h2>\n<p data-start=\"3145\" data-end=\"3595\"><br data-start=\"3218\" data-end=\"3221\" \/>Not all tablets fail in the same way. Some exhibit <strong data-start=\"3272\" data-end=\"3291\">brittle failure<\/strong>, cracking under minimal stress, while others bend or deform. This is where a <strong data-start=\"3369\" data-end=\"3385\">flexure test<\/strong>\u2014often a <strong data-start=\"3394\" data-end=\"3422\">\u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u0442\u0440\u0435\u0445\u0442\u043e\u0447\u0435\u0447\u043d\u044b\u0439 \u0438\u0437\u0433\u0438\u0431<\/strong>\u2014becomes valuable. It evaluates how tablets behave under bending forces, simulating handling scenarios that compress the tablet on one side while stretching it on the other.<\/p>\n<p data-start=\"3597\" data-end=\"3937\">The <strong data-start=\"3601\" data-end=\"3628\">tablet brittleness test<\/strong> evaluates fracture behavior across different strain rates. If a formulation is prone to brittle failure, it may crack during automatic feeding or blister packaging. Flexure testing is especially recommended for elongated or capsule-shaped tablets where diametral compression may not provide reliable results.<\/p>\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u0442\u0432\u0435\u0440\u0434\u043e\u0441\u0442\u044c \u0442\u0430\u0431\u043b\u0435\u0442\u043a\u0438 \u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0435 \u043d\u0430 \u0442\u0432\u0435\u0440\u0434\u043e\u0441\u0442\u044c \u043f\u0440\u0438 \u0441\u0436\u0430\u0442\u0438\u0438 \u0434\u043b\u044f \u0442\u0430\u0431\u043b\u0435\u0442\u043a\u0438 \u043b\u0435\u043a\u0430\u0440\u0441\u0442\u0432\u0430\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/uYgafVVSvpY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<hr data-start=\"3939\" data-end=\"3942\" \/>\n<h2 data-start=\"3944\" data-end=\"4293\"><strong data-start=\"3944\" data-end=\"4007\">Tablet Crushing Strength Testing: Getting the Metrics Right<\/strong><\/h2>\n<p data-start=\"3944\" data-end=\"4293\"><br data-start=\"4007\" data-end=\"4010\" \/>While USP standard discourages using &#8220;hardness&#8221; as a generic term, <strong data-start=\"4075\" data-end=\"4096\">crushing strength<\/strong> remains a widely recognized descriptor for measuring the <strong data-start=\"4154\" data-end=\"4204\">force needed to compress and fracture a tablet<\/strong>. Key variables in this test include platen speed, tablet geometry, and support fixtures.<\/p>\n<p data-start=\"4295\" data-end=\"4602\">Consistency is key. Results must be recorded in newtons (N), and equipment must maintain a <strong data-start=\"4386\" data-end=\"4411\">constant loading rate<\/strong>. Instruments like the <strong data-start=\"4434\" data-end=\"4467\">MPT-02 <\/strong>\u00a0automatically adjust speed and capture real-time data, minimizing operator error and ensuring compliance with pharmacopeial protocols.<\/p>\n<hr data-start=\"4604\" data-end=\"4607\" \/>\n<h2 data-start=\"4609\" data-end=\"4960\"><strong data-start=\"4609\" data-end=\"4662\">Why Tablet Testing is Critical for Your Operation<\/strong><\/h2>\n<p data-start=\"4609\" data-end=\"4960\"><br data-start=\"4662\" data-end=\"4665\" \/>For QA teams, R&amp;D departments, and production engineers, understanding and applying <strong data-start=\"4749\" data-end=\"4763\">USP<\/strong>\u00a0 testing methods helps identify formulation weaknesses before tablets reach the market. Proper testing also reduces returns, supports regulatory audits, and increases confidence in product quality.<\/p>\n<p data-start=\"4962\" data-end=\"5333\">At Cell Instruments, we offer more than just reliable testers\u2014we deliver <strong data-start=\"5035\" data-end=\"5057\">tailored solutions<\/strong> for clients across pharmaceutical, medical packaging, and material science sectors. Whether you&#8217;re evaluating <strong data-start=\"5168\" data-end=\"5190\">tablet brittleness<\/strong>, conducting <strong data-start=\"5203\" data-end=\"5223\">friability tests<\/strong>, or validating <strong data-start=\"5239\" data-end=\"5260\">crushing strength<\/strong>, our instruments support accurate, reproducible measurements every time.<\/p>\n<hr data-start=\"5335\" data-end=\"5338\" \/>\n<h2 data-start=\"5340\" data-end=\"5793\"><strong data-start=\"5340\" data-end=\"5416\">Conclusion: Bring Precision to Your Tablet Testing with Cell Instruments<\/strong><\/h2>\n<p data-start=\"5340\" data-end=\"5793\"><br data-start=\"5416\" data-end=\"5419\" \/>From <strong data-start=\"5424\" data-end=\"5438\">break test<\/strong> \u043a <strong data-start=\"5442\" data-end=\"5458\">flexure test<\/strong>, and from <strong data-start=\"5469\" data-end=\"5488\">\u0442\u0432\u0435\u0440\u0434\u043e\u0441\u0442\u044c<\/strong> \u043a <strong data-start=\"5492\" data-end=\"5506\">friability<\/strong>, every mechanical evaluation provides critical insight into the physical performance of solid dosage forms. By following <strong data-start=\"5628\" data-end=\"5642\">USP<\/strong> and integrating advanced solutions like the <a href=\"https:\/\/www.celtec.cn\/newsinfo\/7623506.html\" target=\"_blank\" rel=\"noopener nofollow\"><strong data-start=\"5687\" data-end=\"5720\">MPT-02 \u0422\u0435\u0441\u0442\u0435\u0440 \u0442\u0432\u0435\u0440\u0434\u043e\u0441\u0442\u0438 \u0442\u0430\u0431\u043b\u0435\u0442\u043e\u043a<\/strong><\/a>, manufacturers can ensure tablets are robust, consistent, and compliant.<\/p>\n<p data-start=\"5795\" data-end=\"6005\">If you&#8217;re optimizing a production line or developing new formulations, contact <strong data-start=\"5874\" data-end=\"5904\">Cell Instruments Co., Ltd.<\/strong> for professional support and high-performance testing instruments that adapt to your evolving needs.<\/p>\n<p data-start=\"5795\" data-end=\"6005\">","protected":false},"excerpt":{"rendered":"<p>\u00a0USP 1217 - \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442 \u0434\u043b\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439 \u0442\u0430\u0431\u043b\u0435\u0442\u043e\u043a \u043d\u0430 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c \u0412 \u0444\u0430\u0440\u043c\u0430\u0446\u0435\u0432\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u043c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0435 \u0446\u0435\u043b\u043e\u0441\u0442\u043d\u043e\u0441\u0442\u044c \u0442\u0430\u0431\u043b\u0435\u0442\u043e\u043a - \u044d\u0442\u043e \u043d\u0435 \u043f\u0440\u043e\u0441\u0442\u043e \u0432\u043d\u0435\u0448\u043d\u0438\u0439 \u0432\u0438\u0434, \u043e\u043d\u0430 \u043d\u0430\u043f\u0440\u044f\u043c\u0443\u044e \u0432\u043b\u0438\u044f\u0435\u0442 \u043d\u0430 \u044d\u0444\u0444\u0435\u043a\u0442\u0438\u0432\u043d\u043e\u0441\u0442\u044c, \u0441\u0442\u0430\u0431\u0438\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u0438 \u0432\u043f\u0435\u0447\u0430\u0442\u043b\u0435\u043d\u0438\u044f \u043f\u0430\u0446\u0438\u0435\u043d\u0442\u043e\u0432. \u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442 USP  \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0435\u0442 \u0432\u0441\u0435\u043e\u0431\u044a\u0435\u043c\u043b\u044e\u0449\u0438\u0435 \u0440\u0430\u043c\u043a\u0438 \u0434\u043b\u044f \u043e\u0446\u0435\u043d\u043a\u0438 \u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438 \u0442\u0430\u0431\u043b\u0435\u0442\u043e\u043a, \u0443\u0434\u0435\u043b\u044f\u044f \u043e\u0441\u043e\u0431\u043e\u0435 \u0432\u043d\u0438\u043c\u0430\u043d\u0438\u0435 \u0442\u0432\u0435\u0440\u0434\u043e\u0441\u0442\u0438, \u0443\u0441\u0438\u043b\u0438\u044e \u043d\u0430 \u0440\u0430\u0437\u0440\u044b\u0432 \u0438 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u043d\u043e\u0439 \u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u0438. \u042d\u0442\u0438 \u043f\u043e\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u0438 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u044f\u044e\u0442 \u0440\u0435\u0446\u0435\u043f\u0442\u0443\u0440\u0443, \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0438\u0432\u0430\u044e\u0442 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c \u043a\u0430\u0447\u0435\u0441\u0442\u0432\u0430 \u0438 \u0433\u0430\u0440\u0430\u043d\u0442\u0438\u0440\u0443\u044e\u0442, \u0447\u0442\u043e \u0442\u0430\u0431\u043b\u0435\u0442\u043a\u0438 ...<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/ru\/standards\/usp-1217\/\"> <span class=\"screen-reader-text\">USP 1217<\/span> \u0427\u0438\u0442\u0430\u0442\u044c \u0434\u0430\u043b\u0435\u0435 \"<\/a><\/p>","protected":false},"author":3,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7328","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/ru\/wp-json\/wp\/v2\/pages\/7328","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/ru\/wp-json\/wp\/v2\/comments?post=7328"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/ru\/wp-json\/wp\/v2\/pages\/7328\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/ru\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/ru\/wp-json\/wp\/v2\/media?parent=7328"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}