{"id":6425,"date":"2025-01-10T11:09:00","date_gmt":"2025-01-10T03:09:00","guid":{"rendered":"https:\/\/www.qualitester.com\/?post_type=product&#038;p=6425"},"modified":"2025-01-10T11:23:17","modified_gmt":"2025-01-10T03:23:17","slug":"iso-7864-needle-penetration-force-measurement-instrument","status":"publish","type":"product","link":"https:\/\/www.qualitester.com\/ro\/produs\/iso-7864-needle-penetration-force-measurement-instrument\/","title":{"rendered":"NPD-01 Tester de penetrare a acului \u0219i for\u021b\u0103 de rezisten\u021b\u0103"},"content":{"rendered":"<p>The <strong>NPD-01 Tester de penetrare a acului \u0219i for\u021b\u0103 de rezisten\u021b\u0103<\/strong> este un instrument de ultim\u0103 genera\u021bie conceput pentru m\u0103surarea precis\u0103 a for\u021belor de penetrare necesare acelor hipodermice. Acesta asigur\u0103 respectarea standardelor interna\u021bionale de testare, precum <a href=\"https:\/\/www.qualitester.com\/ro\/categorie-produs\/iso\/iso-7864\/\" target=\"_blank\" rel=\"noopener\"><strong>ISO 7864<\/strong><\/a> \u0219i <strong>GB 15811<\/strong>, oferind o solu\u021bie fiabil\u0103 pentru testarea performan\u021bei acelor \u00een diverse aplica\u021bii medicale, inclusiv dispozitive de injectare, ace de testare \u0219i alte produse biomedicale.<\/p>\n<h2>Aplica\u021bie pentru testarea penetr\u0103rii \u0219i a for\u021bei de rezisten\u021b\u0103 la \u00eenaintare<\/h2>\n<p>The <strong>Aparat de m\u0103surare a for\u021bei de penetrare a acului<\/strong> este esen\u021bial pentru testarea acelor utilizate \u00eentr-o gam\u0103 larg\u0103 de aplica\u021bii medicale, farmaceutice \u0219i de cercetare. Principalele domenii de aplicare includ:<\/p>\n<ul>\n<li><strong>Dispozitive medicale \u0219i produse farmaceutice<\/strong>: Asigurarea faptului c\u0103 acele hipodermice, lancetele \u0219i alte dispozitive medicale ascu\u021bite permit o inserare u\u0219oar\u0103, care reduce la minimum durerea, men\u021bin\u00e2nd \u00een acela\u0219i timp fiabilitatea \u00een mediul clinic.<\/li>\n<li><strong>Produc\u0103tori de ace<\/strong>: Asigurarea calit\u0103\u021bii pe liniile de produc\u021bie pentru ace hipodermice, seringi \u0219i alte instrumente cu ac.<\/li>\n<li><strong>Cercetare medical\u0103<\/strong>: Testarea unor noi modele de ace \u0219i a unor noi compozi\u021bii pentru ob\u021binerea unor rezultate clinice \u00eembun\u0103t\u0103\u021bite.<\/li>\n<li><strong>Ambalaje<\/strong>: Asigurarea faptului c\u0103 ambalajele medicale pentru ace \u0219i seringi sunt proiectate corespunz\u0103tor, astfel \u00eenc\u00e2t s\u0103 reziste la for\u021bele implicate \u00een procesul de inserare a acului \u0219i \u00een func\u021bionarea sistemelor de administrare a medicamentelor.<\/li>\n<\/ul>\n<h2>Necesitatea test\u0103rii penetr\u0103rii cu acul<\/h2>\n<p>\u00cen\u021belegerea <strong>metoda de testare a penetr\u0103rii cu acul<\/strong> este esen\u021bial pentru asigurarea siguran\u021bei \u0219i eficacit\u0103\u021bii dispozitivelor medicale cu ac. Testarea <strong>for\u021ba de penetrare<\/strong> \u0219i <strong>for\u021ba de rezisten\u021b\u0103 la \u00eenaintare<\/strong> are un dublu scop:<\/p>\n<ol>\n<li><strong>Confortul pacientului<\/strong>: For\u021ba excesiv\u0103 sau frecarea pot provoca durere, anxietate \u0219i complica\u021bii \u00een timpul inject\u0103rii. Prin evaluarea for\u021bei necesare pentru inserare \u0219i mi\u0219care, produc\u0103torii pot proiecta ace care reduc la minimum disconfortul.<\/li>\n<li><strong>Eficacitatea clinic\u0103<\/strong>: Introducerea eficient\u0103 a acului este esen\u021bial\u0103 \u00een contextul clinic. Acele trebuie s\u0103 penetreze cu u\u0219urin\u021b\u0103 pielea sau \u021besutul, f\u0103r\u0103 a provoca \u00eens\u0103 leziuni tisulare \u0219i f\u0103r\u0103 a afecta calitatea administr\u0103rii medicamentului.<\/li>\n<li><strong>Conformitatea cu reglement\u0103rile<\/strong>: Standarde interna\u021bionale precum <strong>ISO 7864<\/strong> \u0219i <strong>GB 15811<\/strong> impun ca acele s\u0103 \u00eendeplineasc\u0103 anumite criterii de performan\u021b\u0103. Aceste <strong>Aparat de testare NPD-01<\/strong> asigur\u0103 respectarea acestor reglement\u0103ri, reduc\u00e2nd riscul de nerespectare a acestora.<\/li>\n<\/ol>\n<p>\u00cen lipsa unor teste precise, produsele care implic\u0103 utilizarea acelor ar putea prezenta deficien\u021be \u00een domenii cruciale, cum ar fi <strong>sterilitate<\/strong>, <strong>fluiditatea injec\u021biei<\/strong>, \u0219i <strong>experien\u021ba utilizatorului<\/strong>, ceea ce ar putea duce la complica\u021bii clinice \u0219i la disconfortul pacientului. Prin urmare, <strong>test de penetrare cu acul<\/strong> nu este doar o chestiune de natur\u0103 tehnic\u0103; este o necesitate pentru integritatea sistemului de s\u0103n\u0103tate.<\/p>\n<h2>Metoda de testare a penetr\u0103rii cu acul<\/h2>\n<p>The <strong>NPD-01 \u2013 Aparat de m\u0103surare a for\u021bei de penetrare a acului<\/strong> func\u021bioneaz\u0103 pe baza unui principiu sofisticat, dar u\u0219or de utilizat:<\/p>\n<ol>\n<li><strong>Configurare<\/strong>: Acul care urmeaz\u0103 s\u0103 fie testat este fixat cu ajutorul unui con Luer de tip tat\u0103, care se conecteaz\u0103 la <strong>celul\u0103 de sarcin\u0103<\/strong>.<\/li>\n<li><strong>Introducerea substratului<\/strong>: Acul este deplasat c\u0103tre un substrat specific (cum ar fi materiale similare pielii sau \u021besuturi sintetice) la o vitez\u0103 controlat\u0103.<\/li>\n<li><strong>M\u0103surarea for\u021bei<\/strong>: \u00cen timpul inser\u0103rii, un <strong>celul\u0103 de sarcin\u0103<\/strong> m\u0103soar\u0103 \u00een mod continuu for\u021ba aplicat\u0103 pe m\u0103sur\u0103 ce acul p\u0103trunde \u00een material. Aceast\u0103 for\u021b\u0103 este \u00eenregistrat\u0103 \u00een diferite etape ale procesului de inserare.<\/li>\n<li><strong>Evaluarea for\u021bei de rezisten\u021b\u0103 la trac\u021biune<\/strong>: Dup\u0103 penetrarea ini\u021bial\u0103, <strong>for\u021ba de rezisten\u021b\u0103 la \u00eenaintare<\/strong> sau se m\u0103soar\u0103 for\u021ba de frecare necesar\u0103 pentru a deplasa acul prin material. Acesta este un indicator esen\u021bial al performan\u021bei acului \u00een condi\u021bii reale de utilizare.<\/li>\n<li><strong>Ie\u0219ire de date<\/strong>: Sistemul transmite datele printr-o interfa\u021b\u0103 intuitiv\u0103 <strong>Ecran tactil HMI<\/strong> \u0219i afi\u0219eaz\u0103 rezultatele folosind un sistem integrat <b>microimprimant\u0103<\/b>.<\/li>\n<\/ol>\n<p>Valorile for\u021bei ob\u021binute \u00een urma testului ofer\u0103 o imagine detaliat\u0103 at\u00e2t asupra <strong>for\u021ba ini\u021bial\u0103 maxim\u0103 de penetrare<\/strong> \u0219i <strong>for\u021bele de frecare<\/strong>, ceea ce \u00eel transform\u0103 \u00eentr-un instrument valoros pentru controlul calit\u0103\u021bii, cercetare \u0219i dezvoltare, precum \u0219i pentru respectarea cerin\u021belor de reglementare.<\/p>\n<h2>Specifica\u021bii tehnice ale aparatului de testare a for\u021bei de rezisten\u021b\u0103 a acului<\/h2>\n<p>Iat\u0103 <strong>caracteristici tehnice principale<\/strong> al <strong>NPD-01 Tester de penetrare a acului \u0219i for\u021b\u0103 de rezisten\u021b\u0103<\/strong>:<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"144\">Celul\u0103 de sarcin\u0103<\/td>\n<td width=\"276\">50 N (sau conform cerin\u021belor)<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">Viteza de testare<\/td>\n<td width=\"276\">1 ~ 500mm\/min<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">Precizia for\u021bei<\/td>\n<td width=\"276\">0,5% F.S.<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">Acurate\u021be<\/td>\n<td width=\"276\">0.01mm<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">Putere<\/td>\n<td width=\"276\">110~220V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Caracteristici tehnice ale aparatului de testare a for\u021bei de penetrare a acului<\/h2>\n<ol>\n<li><strong>Precizie \u0219i fiabilitate<\/strong>: Cu o precizie de 0,01 mm \u0219i o precizie de m\u0103surare a for\u021bei de 0,51 TP3T.<\/li>\n<li><strong>Versatilitate<\/strong>: Instrumentul este compatibil cu ace de diferite dimensiuni \u0219i tipuri, permi\u021b\u00e2nd efectuarea unor teste exhaustive pe o gam\u0103 larg\u0103 de dispozitive medicale.<\/li>\n<li><strong>U\u0219urin\u021ba utiliz\u0103rii<\/strong>: Sistemul controlat prin PLC \u0219i interfa\u021ba intuitiv\u0103 <strong>Ecran tactil HMI<\/strong> s\u0103 faciliteze operatorilor configurarea, monitorizarea \u0219i interpretarea testelor.<\/li>\n<li><strong>Personalizare<\/strong>: Set\u0103rile de vitez\u0103 variabil\u0103 \u0219i ad\u00e2ncimea de penetrare reglabil\u0103 asigur\u0103 adaptarea dispozitivului la cerin\u021bele specifice de testare.<\/li>\n<li><strong>Conformitatea cu standardele<\/strong>: Respect\u0103 pe deplin standardele interna\u021bionale, cum ar fi <strong>ISO 7864<\/strong> \u0219i <strong>GB 15811<\/strong>, ceea ce \u00eel face potrivit pentru test\u0103rile de conformitate cu reglement\u0103rile din diverse regiuni.<\/li>\n<\/ol>\n<h2>Standardul privind testul de penetrare cu acul<\/h2>\n<p>The <strong>NPD-01 \u2013 Aparat de m\u0103surare a for\u021bei de penetrare a acului<\/strong> respect\u0103 diverse standarde interna\u021bionale, fiind astfel adecvat pentru test\u0103ri medicale \u0219i farmaceutice la nivel mondial:<\/p>\n<h3><strong><a href=\"https:\/\/www.iso.org\/standard\/60481.html\" target=\"_blank\" rel=\"nofollow noopener\">ISO 7864<\/a> Anexa D<\/strong><\/h3>\n<ul>\n<li>Specific\u0103 metoda de testare pentru m\u0103surarea <strong>for\u021ba de penetrare<\/strong> \u0219i <strong>for\u021ba de rezisten\u021b\u0103 la \u00eenaintare<\/strong> a acelor, aspect esen\u021bial pentru asigurarea performan\u021bei acestora \u00een timpul utiliz\u0103rii.<\/li>\n<\/ul>\n<h3><strong>GB 15811<\/strong><\/h3>\n<ul>\n<li>Prezentul standard chinez prezint\u0103 metode specifice pentru <strong>test de penetrare cu acul<\/strong>, pe care NPD-01 \u00eel respect\u0103.<\/li>\n<\/ul>\n<p>Utilizarea acestui instrument garanteaz\u0103 c\u0103 produsele dumneavoastr\u0103 respect\u0103 cele mai \u00eenalte standarde din industrie \u0219i sunt adecvate pentru ob\u021binerea aprob\u0103rilor de reglementare pe diferite pie\u021be.<\/p>\n<h2>Asisten\u021b\u0103 \u0219i instruire<\/h2>\n<p>Cell Instruments ofer\u0103 <strong>asisten\u021b\u0103 \u0219i instruire complet\u0103<\/strong> pentru a ajuta utilizatorii s\u0103 profite la maximum de <strong>NPD-01 \u2013 Aparat de m\u0103surare a for\u021bei de penetrare a acului<\/strong>:<\/p>\n<ul>\n<li><strong>Instruirea utilizatorilor<\/strong>: Programele noastre de instruire sunt concepute special pentru a v\u0103 ajuta s\u0103 \u00een\u021belege\u021bi func\u021bionarea instrumentului \u0219i principiile de <strong>testarea acelor<\/strong>.<\/li>\n<li><strong>Asisten\u021b\u0103 tehnic\u0103<\/strong>: Oferim asisten\u021b\u0103 tehnic\u0103 continu\u0103 pentru depanare, \u00eentre\u021binere \u0219i calibrare.<\/li>\n<li><strong>Servicii de calibrare<\/strong>: Pentru a asigura men\u021binerea preciziei, oferim servicii profesionale de calibrare anual.<\/li>\n<\/ul>\n<h2>\u00centreb\u0103ri frecvente (FAQ)<\/h2>\n<p><strong>\u00centrebarea 1: Care sunt avantajele test\u0103rii for\u021bei de rezisten\u021b\u0103 la deplasare a acului?<br \/>\n<\/strong>A1: Testarea for\u021bei de frecare asigur\u0103 deplasarea lin\u0103 a acului prin \u021besuturi, reduc\u00e2nd disconfortul \u0219i \u00eembun\u0103t\u0103\u021bind eficacitatea clinic\u0103. De asemenea, ajut\u0103 la previzionarea performan\u021bei acelor \u00een diverse condi\u021bii.<\/p>\n<p><strong>\u00centrebarea 2: Acest tester poate fi folosit pentru testarea diferitelor tipuri de ace?<\/strong><br \/>\nA2: Da, <strong>NPD-01<\/strong> este un dispozitiv versatil \u0219i poate testa o gam\u0103 larg\u0103 de ace, inclusiv seringi, lancete \u0219i ace hipodermice. Dispozitivul include mai multe suporturi pentru ace de diferite dimensiuni.<\/p>\n<p><strong>\u00centrebarea 3: NPD-01 respect\u0103 standardele interna\u021bionale de testare?<\/strong><br \/>\nA3: Da, <strong>NPD-01<\/strong> respect\u0103 <strong>ISO 7864<\/strong> \u0219i <strong>GB 15811<\/strong>, asigur\u00e2ndu-se c\u0103 acesta respect\u0103 standardele interna\u021bionale de testare pentru dispozitivele medicale.<\/p>\n<p><strong>\u00centrebarea 4: Ce tip de date genereaz\u0103 NPD-01?<\/strong><br \/>\nA4: Dispozitivul NPD-01 ofer\u0103 at\u00e2t m\u0103sur\u0103tori ale for\u021bei \u00een timp real, c\u00e2t \u0219i date privind ad\u00e2ncimea de penetrare, rezultatele fiind disponibile prin intermediul <strong>Ecran tactil HMI<\/strong> \u0219i un sistem integrat <strong>microimprimant\u0103<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Aparatul de m\u0103surare a for\u021bei de penetrare a acului NPD-01 asigur\u0103 test\u0103ri precise \u0219i fiabile ale for\u021bei de inser\u021bie \u0219i a rezisten\u021bei la \u00eenaintare ale acului, esen\u021biale pentru industriile medical\u0103 \u0219i farmaceutic\u0103. Afla\u021bi mai multe despre aplica\u021biile, principiile de func\u021bionare \u0219i caracteristicile tehnice ale acestuia.<\/p>","protected":false},"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":""},"product_cat":[953,956,955,845,1178,1177,934,954,957,958,952,959,149,95],"product_tag":[],"class_list":["post-6425","product","type-product","status-publish","product_cat-bursting-tester","product_cat-cobb-tester","product_cat-crush-tester","product_cat-customization","product_cat-gb-15811","product_cat-iso-7864","product_cat-medical-packaging-tester","product_cat-paper-tear-tester","product_cat-plybond-tester","product_cat-puncture-tester","product_cat-rub-tester","product_cat-stiffness-tester","product_cat-pharma-and-medical-testers","product_cat-products","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/ro\/wp-json\/wp\/v2\/product\/6425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/ro\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.qualitester.com\/ro\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/ro\/wp-json\/wp\/v2\/comments?post=6425"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/ro\/wp-json\/wp\/v2\/product\/6425\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/ro\/wp-json\/wp\/v2\/media?parent=6425"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.qualitester.com\/ro\/wp-json\/wp\/v2\/product_cat?post=6425"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.qualitester.com\/ro\/wp-json\/wp\/v2\/product_tag?post=6425"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}