{"id":7295,"date":"2025-07-30T14:43:33","date_gmt":"2025-07-30T06:43:33","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7295"},"modified":"2025-07-30T14:53:42","modified_gmt":"2025-07-30T06:53:42","slug":"paper-stiffness-tester-with-iso-2493-1-2","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/pl\/applications\/paper-stiffness-tester-with-iso-2493-1-2\/","title":{"rendered":"Tester sztywno\u015bci papieru"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"370\" data-end=\"882\">Kompletny przewodnik po testerach sztywno\u015bci papieru<br \/>\n<small>ISO 2493-1<\/small><\/h1>\n<hr \/>\n<h2><img decoding=\"async\" class=\"wp-image-7302 alignleft\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/ISO-Logo_\u526f\u672c-300x283.webp\" alt=\"urz\u0105dzenie do pomiaru sztywno\u015bci zgodne z norm\u0105 ISO 2493-1\" width=\"127\" height=\"120\" srcset=\"\" sizes=\"(max-width: 127px) 100vw, 127px\" data-srcset=\"\" \/>Zrozumienie normy ISO 2493-1 w kontek\u015bcie testera sztywno\u015bci papieru<\/h2>\n<p>Dok\u0142adny pomiar sztywno\u015bci papieru i tektury ma zasadnicze znaczenie dla zapewnienia optymalnych w\u0142a\u015bciwo\u015bci tych materia\u0142\u00f3w w opakowaniach, poligrafii i innych zastosowaniach przemys\u0142owych. <strong data-start=\"690\" data-end=\"704\">ISO 2493-1<\/strong> Norma ta okre\u015bla niezawodn\u0105 metod\u0119 okre\u015blania odporno\u015bci na zginanie, zapewniaj\u0105c sp\u00f3jno\u015b\u0107 i por\u00f3wnywalno\u015b\u0107 wynik\u00f3w w ramach globalnych proces\u00f3w kontroli jako\u015bci. W niniejszym artykule przedstawiono, jak prawid\u0142owo przeprowadza\u0107 badania zgodnie z norm\u0105 ISO 2493-1, oraz podkre\u015blono znaczenie stosowania odpowiedniego sprz\u0119tu, takiego jak <a href=\"https:\/\/www.qualitester.com\/pl\/produkt-2\/sale-paper-bending-stiffness-tester\/\"><strong data-start=\"1012\" data-end=\"1047\">Tester sztywno\u015bci zginania WTD-01<\/strong><\/a> firmy Cell Instruments.<\/p>\n<hr \/>\n<h2>Dlaczego norma ISO 2493-1 ma znaczenie w przypadku tester\u00f3w papieru<\/h2>\n<p data-start=\"1077\" data-end=\"1489\">Norma ISO 2493-1 okre\u015bla znormalizowan\u0105 metod\u0119 pomiaru <strong data-start=\"1183\" data-end=\"1224\">wytrzyma\u0142o\u015b\u0107 papieru i tektury na zginanie<\/strong> poprzez przy\u0142o\u017cenie si\u0142y na okre\u015blonej d\u0142ugo\u015bci zginania (zazwyczaj 50 mm lub 10 mm) do momentu, gdy pr\u00f3bka osi\u0105gnie okre\u015blony k\u0105t (15\u00b0 lub 7,5\u00b0). Takie podej\u015bcie zapewnia jednolito\u015b\u0107 i powtarzalno\u015b\u0107 wynik\u00f3w, co ma zasadnicze znaczenie dla kontroli jako\u015bci, rozwoju produkt\u00f3w oraz weryfikacji dostawc\u00f3w.<\/p>\n<p data-start=\"1491\" data-end=\"1534\">Do g\u0142\u00f3wnych korzy\u015bci wynikaj\u0105cych ze stosowania normy ISO 2493-1 nale\u017c\u0105:<\/p>\n<ul>\n<li data-start=\"1537\" data-end=\"1574\">Sp\u00f3jno\u015b\u0107 danych mi\u0119dzy laboratoriami<\/li>\n<li data-start=\"1577\" data-end=\"1620\">Wiarygodne por\u00f3wnanie sztywno\u015bci materia\u0142\u00f3w<\/li>\n<li data-start=\"1623\" data-end=\"1678\">Lepsza kontrola w procesach konwersji i drukowania<\/li>\n<\/ul>\n<p data-start=\"1680\" data-end=\"1794\">Dla producent\u00f3w przestrzeganie normy ISO 2493-1 oznacza wi\u0119ksz\u0105 niezawodno\u015b\u0107 produkt\u00f3w i zmniejszenie liczby awarii podczas u\u017cytkowania.<\/p>\n<hr \/>\n<h2 data-start=\"1680\" data-end=\"1794\">Urz\u0105dzenie do badania sztywno\u015bci papieru oraz metoda badania sztywno\u015bci wed\u0142ug Tabera<\/h2>\n<p data-start=\"1801\" data-end=\"2143\">The <strong data-start=\"1870\" data-end=\"1901\">Metoda badania sztywno\u015bci metod\u0105 Tabera<\/strong> jest to powszechnie stosowana metoda oceny sztywno\u015bci na zginanie materia\u0142\u00f3w papierowych i tekturowych. Polega ona na zamocowaniu pr\u00f3bki i przy\u0142o\u017ceniu si\u0142y za pomoc\u0105 st\u0119pionego ostrza no\u017ca umieszczonego w sta\u0142ej odleg\u0142o\u015bci, tak aby wygi\u0105\u0107 pr\u00f3bk\u0119 pod okre\u015blonym k\u0105tem.<\/p>\n<p data-start=\"2145\" data-end=\"2229\">Aby spe\u0142ni\u0107 wymagania normy ISO 2493-1, wysokiej jako\u015bci <strong data-start=\"2187\" data-end=\"2213\">urz\u0105dzenie do badania sztywno\u015bci papieru<\/strong> musi zawiera\u0107:<\/p>\n<ul>\n<li data-start=\"2232\" data-end=\"2286\">Precyzyjne czujniki si\u0142y (\u00b15% poni\u017cej 100 mN, \u00b12% powy\u017cej)<\/li>\n<li data-start=\"2289\" data-end=\"2346\">Precyzyjna regulacja k\u0105ta gi\u0119cia (15\u00b0 lub opcjonalnie 7,5\u00b0)<\/li>\n<li data-start=\"2349\" data-end=\"2411\">Regulowany nacisk zacisku zapobiegaj\u0105cy ze\u015blizgiwaniu si\u0119 lub odkszta\u0142ceniom<\/li>\n<li data-start=\"2414\" data-end=\"2445\">Powtarzalne ustawianie pr\u00f3bki<\/li>\n<\/ul>\n<p data-start=\"2447\" data-end=\"2724\">The <strong data-start=\"2451\" data-end=\"2503\">Cell Instruments WTD-01 \u2013 tester sztywno\u015bci przy zginaniu<\/strong> jest w pe\u0142ni zgodny z norm\u0105 ISO 2493-1 i zaprojektowany z my\u015bl\u0105 o wysokiej precyzji oraz \u0142atwo\u015bci obs\u0142ugi. Wyposa\u017cony jest w inteligentny interfejs, automatyczn\u0105 regulacj\u0119 k\u0105ta oraz solidne mechanizmy mocuj\u0105ce, co gwarantuje precyzyjne przeprowadzenie badania.<\/p>\n<hr \/>\n<h2 data-start=\"2447\" data-end=\"2724\">Procedury przygotowania pr\u00f3bek i przeprowadzania bada\u0144<\/h2>\n<p>W\u0142a\u015bciwe przygotowanie i kondycjonowanie maj\u0105 kluczowe znaczenie dla uzyskania miarodajnych wynik\u00f3w bada\u0144. Nale\u017cy post\u0119powa\u0107 zgodnie z poni\u017cszymi wskaz\u00f3wkami, zgodnie z norm\u0105 ISO 2493-1:<\/p>\n<h3>Przygotowanie pr\u00f3bek i pobieranie pr\u00f3bek<\/h3>\n<ul>\n<li data-start=\"2937\" data-end=\"2984\">Przygotowanie pr\u00f3bek zgodnie z <strong data-start=\"2970\" data-end=\"2981\">ISO 187<\/strong>.<\/li>\n<li data-start=\"2987\" data-end=\"3039\">Wybierz pr\u00f3bki na <strong data-start=\"3006\" data-end=\"3017\">ISO 186<\/strong> do oceny dzia\u0142ki.<\/li>\n<\/ul>\n<h3>Ci\u0119cie pr\u00f3bek<\/h3>\n<ul>\n<li data-start=\"3069\" data-end=\"3141\">Wytnij po 10 pr\u00f3bek w ka\u017cdym z g\u0142\u00f3wnych kierunk\u00f3w (wzd\u0142u\u017c i\/lub w poprzek).<\/li>\n<li data-start=\"3144\" data-end=\"3223\">Wymiary: szeroko\u015b\u0107 (38,0 \u00b1 0,2) mm, d\u0142ugo\u015b\u0107 co najmniej 80 mm przy d\u0142ugo\u015bci zgi\u0119cia wynosz\u0105cej 50 mm.<\/li>\n<\/ul>\n<h3>Protok\u00f3\u0142 bada\u0144<\/h3>\n<ol>\n<li data-start=\"3251\" data-end=\"3340\">W\u0142\u00f3\u017c pr\u00f3bk\u0119 do zacisku, dbaj\u0105c o prawid\u0142owe ustawienie i minimalny kontakt z r\u0119kami.<\/li>\n<li data-start=\"3344\" data-end=\"3424\">Nale\u017cy stosowa\u0107 standardow\u0105 d\u0142ugo\u015b\u0107 gi\u0119cia wynosz\u0105c\u0105 50 mm (lub 10 mm w przypadku materia\u0142\u00f3w o niskiej sztywno\u015bci).<\/li>\n<li data-start=\"3428\" data-end=\"3517\">Ustaw instrument na <strong data-start=\"3452\" data-end=\"3473\">K\u0105t zgi\u0119cia 15\u00b0<\/strong> (lub 7,5\u00b0 w przypadku pr\u00f3bek grubych lub wra\u017cliwych).<\/li>\n<li data-start=\"3521\" data-end=\"3578\">Przed przeprowadzeniem badania nale\u017cy unika\u0107 zginania lub zagniatania pr\u00f3bki.<\/li>\n<li data-start=\"3582\" data-end=\"3639\">Zarejestruj si\u0142\u0119 wywieran\u0105 przez n\u00f3\u017c podczas wyginania pr\u00f3bki.<\/li>\n<\/ol>\n<p><strong data-start=\"3643\" data-end=\"3656\">Wa\u017cne<\/strong>: Nale\u017cy stosowa\u0107 sta\u0142y nacisk mocowania i unika\u0107 ponownego wykorzystywania pr\u00f3bek. Du\u017ca si\u0142a mocowania mo\u017ce spowodowa\u0107 sztucznie zani\u017cone warto\u015bci sztywno\u015bci.<\/p>\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Test sztywno\u015bci zginania papieru i tektury ISO 5628 ISO 2493\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/yuaDfFkcMtA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<hr \/>\n<h2>Typowe wyzwania i sposoby ich unikania<\/h2>\n<ul>\n<li data-start=\"4475\" data-end=\"4574\"><strong data-start=\"4475\" data-end=\"4504\">Odkszta\u0142canie lub zwijanie si\u0119 pr\u00f3bki<\/strong>: Prowadzi to do niewiarygodnych wynik\u00f3w. Nale\u017cy unika\u0107 stosowania pr\u00f3bek, kt\u00f3re s\u0105 w widoczny spos\u00f3b zdeformowane.<\/li>\n<li data-start=\"4577\" data-end=\"4651\"><strong data-start=\"4577\" data-end=\"4602\">Nier\u00f3wnomierne zaciskanie<\/strong>: Aby zapewni\u0107 sta\u0142y nacisk, nale\u017cy stosowa\u0107 zaciski pneumatyczne.<\/li>\n<li data-start=\"4654\" data-end=\"4773\"><strong data-start=\"4654\" data-end=\"4692\">B\u0142\u0119dne podanie d\u0142ugo\u015bci gi\u0119cia<\/strong>: Nale\u017cy zawsze podawa\u0107, czy zastosowano 10 mm; warto\u015bci wynosz\u0105 <strong data-start=\"4738\" data-end=\"4745\">nie<\/strong> mo\u017cna stosowa\u0107 zamiennie z rozmiarem 50 mm.<\/li>\n<\/ul>\n<hr \/>\n<h2>Dlaczego warto wybra\u0107 <a href=\"https:\/\/www.qualitester.com\/pl\/\">Cell Instruments<\/a> WTD-01 Tester sztywno\u015bci<\/h2>\n<p data-start=\"4780\" data-end=\"5018\" data-wp-editing=\"1\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-7300 alignright\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/DJI_20230420_161326_147_\u526f\u672c_\u526f\u672c_\u526f\u672c-300x237.webp\" alt=\"tester sztywno\u015bci \" width=\"300\" height=\"237\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/DJI_20230420_161326_147_\u526f\u672c_\u526f\u672c_\u526f\u672c-300x237.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/DJI_20230420_161326_147_\u526f\u672c_\u526f\u672c_\u526f\u672c-1024x811.webp 1024w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/DJI_20230420_161326_147_\u526f\u672c_\u526f\u672c_\u526f\u672c-768x608.webp 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/DJI_20230420_161326_147_\u526f\u672c_\u526f\u672c_\u526f\u672c-1536x1216.webp 1536w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/DJI_20230420_161326_147_\u526f\u672c_\u526f\u672c_\u526f\u672c-2048x1621.webp 2048w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/DJI_20230420_161326_147_\u526f\u672c_\u526f\u672c_\u526f\u672c-15x12.webp 15w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/DJI_20230420_161326_147_\u526f\u672c_\u526f\u672c_\u526f\u672c-600x475.webp 600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>The <strong data-start=\"4846\" data-end=\"4881\">Tester sztywno\u015bci zginania WTD-01<\/strong> z <strong data-start=\"4887\" data-end=\"4907\">Cell Instruments<\/strong> zapewnia pe\u0142n\u0105 zgodno\u015b\u0107 z norm\u0105 ISO 2493-1 oraz umo\u017cliwia przeprowadzanie precyzyjnych i powtarzalnych bada\u0144. Do g\u0142\u00f3wnych zalet nale\u017c\u0105:<\/p>\n<ul>\n<li data-start=\"5021\" data-end=\"5061\">Automatyczna regulacja k\u0105ta (15\u00b0 i 7,5\u00b0)<\/li>\n<li data-start=\"5064\" data-end=\"5095\">Czujniki si\u0142y o wysokiej rozdzielczo\u015bci<\/li>\n<li data-start=\"5098\" data-end=\"5148\">Obs\u0142uga d\u0142ugo\u015bci gi\u0119cia zar\u00f3wno 50 mm, jak i 10 mm<\/li>\n<li data-start=\"5151\" data-end=\"5207\">Intuicyjny interfejs oprogramowania z funkcj\u0105 analizy statystycznej<\/li>\n<\/ul>\n<p data-start=\"5209\" data-end=\"5381\">Urz\u0105dzenie to idealnie nadaje si\u0119 dla laboratori\u00f3w kontroli jako\u015bci oraz zespo\u0142\u00f3w badawczo-rozwojowych w bran\u017cach opakowaniowej, poligraficznej i produkcji materia\u0142\u00f3w, kt\u00f3re wymagaj\u0105 dok\u0142adno\u015bci i niezawodno\u015bci w pomiarach sztywno\u015bci.<\/p>\n<hr \/>\n<h2 data-start=\"5209\" data-end=\"5381\">Wnioski<\/h2>\n<p data-start=\"5388\" data-end=\"5870\">Zgodnie z <strong data-start=\"5420\" data-end=\"5434\">ISO 2493-1<\/strong> zapewnia dok\u0142adne i znormalizowane badania sztywno\u015bci papieru. Dzi\u0119ki zastosowaniu <strong data-start=\"5510\" data-end=\"5541\">Metoda badania sztywno\u015bci metod\u0105 Tabera<\/strong> oraz korzystaj\u0105c z us\u0142ug wykwalifikowanego <strong data-start=\"5564\" data-end=\"5590\">urz\u0105dzenie do badania sztywno\u015bci papieru<\/strong> tak jak <strong data-start=\"5600\" data-end=\"5632\">WTD-01 firmy Cell Instruments<\/strong>, specjali\u015bci mog\u0105 uzyska\u0107 wiarygodne wyniki, poprawi\u0107 w\u0142a\u015bciwo\u015bci materia\u0142\u00f3w oraz zapewni\u0107 jako\u015b\u0107 produkt\u00f3w. Prawid\u0142owe przygotowanie bada\u0144, kalibracja sprz\u0119tu oraz przestrzeganie standardowych procedur maj\u0105 zasadnicze znaczenie dla uzyskania wiarygodnych wynik\u00f3w.<\/p>\n<hr \/>\n<h2 data-start=\"5388\" data-end=\"5870\">Sekcja FAQ<\/h2>\n<ol>\n<li><strong data-start=\"5896\" data-end=\"5959\">Jaki jest g\u0142\u00f3wny cel normy ISO 2493-1 w badaniach papieru?<\/strong><br data-start=\"5959\" data-end=\"5962\" \/>Norma ta ujednolica metod\u0119 okre\u015blania wytrzyma\u0142o\u015bci papieru i tektury na zginanie w celu zapewnienia sp\u00f3jnych i por\u00f3wnywalnych wynik\u00f3w.<\/li>\n<li><strong data-start=\"6093\" data-end=\"6143\">Kiedy nale\u017cy stosowa\u0107 k\u0105t zgi\u0119cia wynosz\u0105cy 7,5\u00b0?<\/strong><br data-start=\"6143\" data-end=\"6146\" \/>W przypadku grubych lub sztywnych pr\u00f3bek, kt\u00f3re mog\u0105 ulec odkszta\u0142ceniu lub p\u0119kni\u0119ciu przed osi\u0105gni\u0119ciem k\u0105ta 15\u00b0, nale\u017cy ustawi\u0107 k\u0105t 7,5\u00b0.<\/li>\n<li><strong data-start=\"6229\" data-end=\"6302\">Czy mo\u017cna por\u00f3wna\u0107 wyniki bada\u0144 dla d\u0142ugo\u015bci zginania wynosz\u0105cych 10 mm i 50 mm?<\/strong><br data-start=\"6302\" data-end=\"6305\" \/>Nie. Wyniki uzyskane dla r\u00f3\u017cnych d\u0142ugo\u015bci zginania nie s\u0105 bezpo\u015brednio por\u00f3wnywalne i nale\u017cy je przedstawia\u0107 oddzielnie.<\/li>\n<li><strong data-start=\"6410\" data-end=\"6469\">Ile pr\u00f3bek nale\u017cy zbada\u0107 w ka\u017cdym kierunku?<\/strong><br data-start=\"6469\" data-end=\"6472\" \/>Co najmniej 10 pr\u00f3bek w ka\u017cdym kierunku (wzd\u0142u\u017cnym i\/lub poprzecznym) z prawid\u0142owymi pomiarami.<\/li>\n<li><strong data-start=\"6555\" data-end=\"6629\">Dlaczego tester sztywno\u015bci przy zginaniu WTD-01 jest zgodny z norm\u0105 ISO 2493-1?<\/strong><br data-start=\"6629\" data-end=\"6632\" \/>Urz\u0105dzenie zapewnia automatyczne sterowanie, wysok\u0105 dok\u0142adno\u015b\u0107, zgodno\u015b\u0107 ze wszystkimi wymaganiami normy ISO 2493-1 oraz \u0142atw\u0105 obs\u0142ug\u0119.<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Kompletny przewodnik po testerze sztywno\u015bci papieru ISO 2493-1 Zrozumienie normy ISO 2493-1 w testerze sztywno\u015bci papieru Dok\u0142adny pomiar sztywno\u015bci papieru i tektury jest niezb\u0119dny do zapewnienia optymalnej wydajno\u015bci materia\u0142u w opakowaniach, druku i innych zastosowaniach przemys\u0142owych. Norma ISO 2493-1 okre\u015bla niezawodn\u0105 metod\u0119 okre\u015blania odporno\u015bci na zginanie, oferuj\u0105c sp\u00f3jno\u015b\u0107 i por\u00f3wnywalno\u015b\u0107 na ca\u0142ym \u015bwiecie ...<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/pl\/applications\/paper-stiffness-tester-with-iso-2493-1-2\/\"> <span class=\"screen-reader-text\">Tester sztywno\u015bci papieru<\/span> Czytaj wi\u0119cej \"<\/a><\/p>","protected":false},"author":3,"featured_media":0,"parent":6794,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7295","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/pl\/wp-json\/wp\/v2\/pages\/7295","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/pl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/pl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/pl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/pl\/wp-json\/wp\/v2\/comments?post=7295"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/pl\/wp-json\/wp\/v2\/pages\/7295\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/pl\/wp-json\/wp\/v2\/pages\/6794"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/pl\/wp-json\/wp\/v2\/media?parent=7295"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}