{"id":6958,"date":"2025-07-15T13:32:24","date_gmt":"2025-07-15T05:32:24","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=6958"},"modified":"2025-07-15T13:32:24","modified_gmt":"2025-07-15T05:32:24","slug":"finat-ftm-9","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/nb\/standards\/finat-ftm-9\/","title":{"rendered":"FINAT FTM 9"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"370\" data-end=\"882\">FINAT FTM 9<br \/>\n<small>Loop Tack Testing<\/small><\/h1>\n<hr \/>\n<p data-start=\"437\" data-end=\"768\">Pressure-sensitive adhesives (PSAs) are essential in packaging, labeling, and other industrial applications, where their <strong data-start=\"558\" data-end=\"574\">initial tack<\/strong>\u2014the ability to quickly grab a surface\u2014is critical. The <strong data-start=\"630\" data-end=\"645\">FINAT FTM 9<\/strong> test method provides a reliable and standardized procedure for measuring this property through a loop tack configuration.<\/p>\n<p data-start=\"770\" data-end=\"1180\">Used globally in quality control and R&amp;D, <em data-start=\"812\" data-end=\"825\">FINAT FTM 9<\/em> plays a crucial role in helping manufacturers select the most effective adhesive materials, particularly for high-speed automatic labeling lines. In this article, we will delve into the <strong data-start=\"1012\" data-end=\"1037\">metode for testing av l\u00f8kkeheft<\/strong>, its importance, procedures, equipment requirements, and how Cell Instruments&#8217; <em data-start=\"1117\" data-end=\"1142\"><a href=\"https:\/\/www.qualitester.com\/nb\/produkt-2\/sale-tape-loop-tack-testing-machine\/\">LTT-01<\/a> Loop Tack Tester<\/em> ensures compliance with the standard.<\/p>\n<hr \/>\n<h2 data-start=\"770\" data-end=\"1180\">What Is FINAT FTM 9?<\/h2>\n<p data-start=\"1213\" data-end=\"1568\"><strong data-start=\"1213\" data-end=\"1228\">FINAT FTM 9<\/strong> is a standardized test method published by FINAT (the European association for the self-adhesive label industry) for determining the <strong data-start=\"1362\" data-end=\"1375\">l\u00f8kkeheft<\/strong> of pressure-sensitive materials. Tack, distinct from adhesion or cohesion, refers to the adhesive\u2019s ability to form an immediate bond with a substrate under brief contact and minimal pressure.<\/p>\n<p data-start=\"1570\" data-end=\"1779\">This method offers a practical way to compare the &#8220;grab&#8221; strength of different label or tape materials, a property that is especially relevant in fast-paced application environments such as labeling machinery.<\/p>\n<hr \/>\n<h2 data-start=\"1570\" data-end=\"1779\">Why Is Loop Tack Testing Important?<\/h2>\n<p data-start=\"1827\" data-end=\"2059\">Den <strong data-start=\"1831\" data-end=\"1844\">l\u00f8kkeheft<\/strong> value directly correlates with application performance, especially in systems where the adhesive must bond instantly with minimal dwell time. A high loop tack value indicates better immediate adhesion, critical in:<\/p>\n<ul>\n<li data-start=\"2063\" data-end=\"2120\"><strong data-start=\"2063\" data-end=\"2084\">Labeling machines<\/strong> where materials must bond instantly<\/li>\n<li data-start=\"2123\" data-end=\"2152\"><strong data-start=\"2123\" data-end=\"2152\">Medical tape applications<\/strong><\/li>\n<li data-start=\"2155\" data-end=\"2203\"><strong data-start=\"2155\" data-end=\"2177\">Consumer packaging<\/strong> requiring instant closure<\/li>\n<li data-start=\"2206\" data-end=\"2233\"><strong data-start=\"2206\" data-end=\"2233\">Temporary bonding needs<\/strong><\/li>\n<\/ul>\n<p data-start=\"2235\" data-end=\"2373\">Accurate measurement of loop tack helps manufacturers control quality, fine-tune formulations, and meet customer performance expectations.<\/p>\n<hr \/>\n<h2 data-start=\"2235\" data-end=\"2373\">Loop Tack Test Method Overview<\/h2>\n<p>Den <strong data-start=\"2420\" data-end=\"2445\">metode for testing av l\u00f8kkeheft<\/strong>, slik det er definert i <em data-start=\"2461\" data-end=\"2474\">FINAT FTM 9<\/em>, involves bringing a looped strip of pressure-sensitive material into contact with a standard substrate (typically float glass), then separating it at a fixed speed to measure the peak force of detachment.<\/p>\n<h3>Test Equipment<\/h3>\n<ul>\n<li data-start=\"2704\" data-end=\"2892\">A <strong data-start=\"2706\" data-end=\"2724\">strekkpr\u00f8vetester<\/strong> or universal testing machine with a vertical jaw separation speed of <strong data-start=\"2794\" data-end=\"2808\">300 mm\/min<\/strong>, reversible direction, and force measurement up to <strong data-start=\"2860\" data-end=\"2873\">20 Newton<\/strong> with \u00b12% accuracy.<\/li>\n<li data-start=\"2895\" data-end=\"2984\">A <strong data-start=\"2897\" data-end=\"2912\">glass plate<\/strong> measuring 25 mm \u00d7 30 mm (\u00b1 tolerances), attached to a peg for mounting.<\/li>\n<\/ul>\n<hr \/>\n<h2>Klargj\u00f8ring og kondisjonering av pr\u00f8ver<\/h2>\n<ul>\n<li data-start=\"3211\" data-end=\"3272\">Strips should be <strong data-start=\"3228\" data-end=\"3258\">25 mm wide and 175 mm long<\/strong>, cleanly cut.<\/li>\n<li data-start=\"3275\" data-end=\"3323\">Backing material is removed just before testing.<\/li>\n<li data-start=\"3326\" data-end=\"3411\">Strips are looped with <strong data-start=\"3349\" data-end=\"3370\">adhesive side out<\/strong> and clamped into the tester&#8217;s upper jaw.<\/li>\n<li data-start=\"3414\" data-end=\"3560\">Test conditions are set at <strong data-start=\"3441\" data-end=\"3455\">23\u00b0C \u00b1 2\u00b0C<\/strong> og <strong data-start=\"3460\" data-end=\"3475\">50% RH \u00b1 5%<\/strong> with a minimum <strong data-start=\"3491\" data-end=\"3514\">4-hour conditioning<\/strong> period for both test specimens and substrate.<\/li>\n<\/ul>\n<hr \/>\n<h2>Test Procedure<\/h2>\n<ol>\n<li data-start=\"3590\" data-end=\"3648\">Loop the adhesive strip and insert it into the upper grip.<\/li>\n<li data-start=\"3652\" data-end=\"3702\">Clamp the cleaned glass plate into the lower grip.<\/li>\n<li data-start=\"3706\" data-end=\"3780\">Bring the adhesive loop into contact with the substrate at <strong data-start=\"3765\" data-end=\"3779\">300 mm\/min<\/strong>.<\/li>\n<li data-start=\"3784\" data-end=\"3853\">Immediately reverse direction to separate the loop at the same speed.<\/li>\n<li data-start=\"3857\" data-end=\"3916\">Ta opp <strong data-start=\"3868\" data-end=\"3882\">maksimal kraft<\/strong> (excluding initial noise spikes).<\/li>\n<li data-start=\"3920\" data-end=\"3993\">Repeat with <strong data-start=\"3932\" data-end=\"3948\">five samples<\/strong> and report the average value in <strong data-start=\"3981\" data-end=\"3992\">Newtons<\/strong>.<\/li>\n<\/ol>\n<p data-start=\"3995\" data-end=\"4005\">Notations:<\/p>\n<ul>\n<li data-start=\"4008\" data-end=\"4080\">If tearing occurs before adhesive release \u2192 mark with <em data-start=\"4062\" data-end=\"4066\">PT<\/em> (paper tear).<\/li>\n<li data-start=\"4083\" data-end=\"4186\">If adhesive transfers to the plate \u2192 mark with <em data-start=\"4130\" data-end=\"4134\">AT<\/em> (adhesive transfer), noting approximate percentage.\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Finat 9 Loop Tack Test Sample\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/tVZSoEi7Blk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/li>\n<\/ul>\n<hr \/>\n<h2>Factors Influencing Test Accuracy<\/h2>\n<p data-start=\"4232\" data-end=\"4279\">Several variables can affect loop tack results:<\/p>\n<ul>\n<li data-start=\"4283\" data-end=\"4446\"><strong data-start=\"4283\" data-end=\"4308\">Substrate cleanliness<\/strong> \u2013 Use non-residual solvents like MEK, acetone, or n-heptane. Repeat cleaning three times and let plates condition for 4 hours before use.<\/li>\n<li data-start=\"4449\" data-end=\"4507\"><strong data-start=\"4449\" data-end=\"4468\">Sample rigidity<\/strong> \u2013 Affects loop shape and contact area.<\/li>\n<li data-start=\"4510\" data-end=\"4618\"><strong data-start=\"4510\" data-end=\"4538\">Environmental conditions<\/strong> \u2013 Must be strictly controlled as tack is sensitive to humidity and temperature.<\/li>\n<\/ul>\n<hr \/>\n<h2>Hvorfor velge <a href=\"https:\/\/www.qualitester.com\/nb\/\">Cell Instruments<\/a>\u2019 LTT-01 for Loop Tack Testing<\/h2>\n<figure id=\"attachment_6966\" aria-describedby=\"caption-attachment-6966\" style=\"width: 300px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.qualitester.com\/nb\/produkt-2\/sale-tape-loop-tack-testing-machine\/\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-6966 size-medium\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Tape-Loop-Tack-Testing-Machine-300x300.webp\" alt=\"FINAT FTM 9 is a standardized loop tack test method.\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Tape-Loop-Tack-Testing-Machine-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Tape-Loop-Tack-Testing-Machine-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Tape-Loop-Tack-Testing-Machine-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Tape-Loop-Tack-Testing-Machine-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Tape-Loop-Tack-Testing-Machine.webp 600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-6966\" class=\"wp-caption-text\">LTT-01 Loop Tack Tester<\/figcaption><\/figure>\n<p data-start=\"4688\" data-end=\"4809\">Den <strong data-start=\"4692\" data-end=\"4719\">LTT-01 Loop Tack Tester<\/strong> from Cell Instruments is designed specifically to meet <strong data-start=\"4775\" data-end=\"4790\">FINAT FTM 9<\/strong> requirements with:<\/p>\n<ul>\n<li data-start=\"4813\" data-end=\"4887\"><strong data-start=\"4813\" data-end=\"4836\">Precision mechanics<\/strong> ensuring consistent 300 mm\/min contact\/separation.<\/li>\n<li data-start=\"4890\" data-end=\"4964\"><strong data-start=\"4890\" data-end=\"4945\">Touchscreen control and programmable test sequences<\/strong> for repeatability.<\/li>\n<li data-start=\"4967\" data-end=\"5042\"><strong data-start=\"4967\" data-end=\"4993\">Data output in Newtons<\/strong>, including automatic averaging of multiple runs.<\/li>\n<li data-start=\"5045\" data-end=\"5099\"><strong data-start=\"5045\" data-end=\"5081\">Compliance with global standards<\/strong> for tack testing.<\/li>\n<\/ul>\n<p data-start=\"5101\" data-end=\"5318\">For manufacturers and labs aiming to ensure consistent product quality or meet regulatory and customer-specific adhesive performance benchmarks, LTT-01 offers the ideal balance of accuracy, usability, and reliability.<\/p>\n<hr \/>\n<h2 data-start=\"5101\" data-end=\"5318\">Konklusjon<\/h2>\n<p data-start=\"5341\" data-end=\"5700\">Den <strong data-start=\"5345\" data-end=\"5360\">FINAT FTM 9<\/strong> loop tack test method is a critical tool for evaluating the initial tack of pressure-sensitive adhesives. By adopting this standardized approach and using reliable instruments like the <strong data-start=\"5546\" data-end=\"5573\">LTT-01 Loop Tack Tester<\/strong> fra <strong data-start=\"5579\" data-end=\"5599\">Cell Instruments<\/strong>, manufacturers can ensure high-performance bonding in labeling, packaging, and medical applications.<\/p>\n<p data-start=\"5702\" data-end=\"5854\">Understanding loop tack values is not just about numbers\u2014it\u2019s about optimizing performance, reducing failure rates, and improving end-user satisfaction.<\/p>","protected":false},"excerpt":{"rendered":"<p>FINAT FTM 9-test av klebeevne ved l\u00f8kke: Trykkf\u00f8lsomme lim (PSA) er avgj\u00f8rende innen emballasje, merking og andre industrielle anvendelser, der deres innledende klebeevne \u2013 evnen til raskt \u00e5 feste seg til en overflate \u2013 er avgj\u00f8rende. Testmetoden FINAT FTM 9 gir en p\u00e5litelig og standardisert prosedyre for m\u00e5ling av denne egenskapen ved hjelp av en loop-tack-konfigurasjon. Brukes globalt innen kvalitetskontroll \u2026<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/nb\/standards\/finat-ftm-9\/\"> <span class=\"screen-reader-text\">FINAT FTM 9<\/span> Les mer \"<\/a><\/p>","protected":false},"author":3,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-6958","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/pages\/6958","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/comments?post=6958"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/pages\/6958\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/media?parent=6958"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}