{"id":6928,"date":"2025-07-15T16:28:36","date_gmt":"2025-07-15T08:28:36","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=6928"},"modified":"2025-07-23T13:53:20","modified_gmt":"2025-07-23T05:53:20","slug":"astm-d6195-2","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/nb\/standards\/astm-d6195-2\/","title":{"rendered":"ASTM D6195"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"381\" data-end=\"855\">ASTM D6195<br \/>\nMetode for testing av l\u00f8kkeklammer<\/h1>\n<p data-start=\"542\" data-end=\"1040\">For produsenter av trykkf\u00f8lsomme lim (PSA) er det avgj\u00f8rende \u00e5 oppn\u00e5 sterk initial klebrighet - spesielt n\u00e5r det gjelder h\u00f8yhastighetsemballasje, medisinske teip, etiketter og industrifilmer. Den <a href=\"https:\/\/www.qualitester.com\/nb\/standards\/astm-d6195\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"727\" data-end=\"741\">ASTM D6195<\/strong> <\/a>testmetode tilbyr en standardisert tiln\u00e6rming til \u00e5 evaluere denne \"quick-stick\"-atferden. Testmetoden er spesielt utviklet for \u00e5 kvantifisere hvor godt et lim fester seg under minimalt trykk og kort kontakttid, og loop tack-testen som er beskrevet i ASTM D6195, er avgj\u00f8rende for b\u00e5de produktutvikling og kvalitetskontroll.<\/p>\n<p data-start=\"1042\" data-end=\"1352\">Ved hjelp av en dedikert <strong data-start=\"1060\" data-end=\"1080\">loop tack tester<\/strong>-som for eksempel LTT-01 fra<a href=\"https:\/\/www.celtec.cn\" target=\"_blank\" rel=\"noopener nofollow\"> Cell Instruments<\/a>-sikrer n\u00f8yaktighet, repeterbarhet og samsvar med internasjonale standarder. I denne artikkelen forklarer vi ASTM D6195-standarden, beskriver testprosedyren i detalj og forklarer hvorfor loop tack er viktig i evalueringen av limets ytelse.<\/p>\n<h2 data-start=\"1095\" data-end=\"1451\">Testmetode for sl\u00f8yfeklebrighet og sl\u00f8yfeklebrighetstester i ASTM D6195<\/h2>\n<p data-start=\"1421\" data-end=\"1651\">Den <strong data-start=\"1425\" data-end=\"1450\">metode for testing av l\u00f8kkeheft<\/strong>som definert i ASTM D6195, m\u00e5ler den maksimale kraften som kreves for \u00e5 skille en l\u00f8kke av teip fra en standardisert overflate etter et \u00f8yeblikks kontakt. Det finnes to offisielle metoder i henhold til denne standarden:<\/p>\n<ul data-start=\"1653\" data-end=\"1846\">\n<li data-start=\"1653\" data-end=\"1740\">\n<p data-start=\"1655\" data-end=\"1740\"><strong data-start=\"1655\" data-end=\"1667\">Metode A<\/strong>: Utf\u00f8rt p\u00e5 en universell strekktester ved hjelp av en 7-tommers klebestrimmel<\/p>\n<\/li>\n<li data-start=\"1741\" data-end=\"1846\">\n<p data-start=\"1743\" data-end=\"1846\"><strong data-start=\"1743\" data-end=\"1755\">Metode B<\/strong>: Bruker en dedikert <strong data-start=\"1774\" data-end=\"1794\">loop tack tester<\/strong> med en 5-tommers stripe for str\u00f8mlinjeformede QC-applikasjoner<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1848\" data-end=\"2142\">I begge tilfeller formes limpr\u00f8ven til en l\u00f8kke og bringes i kontakt med en <strong data-start=\"1937\" data-end=\"1967\">testpanel i rustfritt st\u00e5l<\/strong>. De <strong data-start=\"1973\" data-end=\"2007\">maksimal kraft som kreves for \u00e5 skrelle<\/strong> limsl\u00f8yfen fra overflaten registreres som <em data-start=\"2062\" data-end=\"2079\">loop tack-verdi<\/em>-en direkte indikator p\u00e5 limets opprinnelige limstyrke.<\/p>\n<h2 data-start=\"2075\" data-end=\"2354\">Steg-for-steg-veiledning til ASTM D6195 Loop Tack Testing<\/h2>\n<p data-start=\"2205\" data-end=\"2327\">For \u00e5 sikre konsistente og p\u00e5litelige resultater for sl\u00f8yfeklebning er det avgj\u00f8rende \u00e5 f\u00f8lge standardprosedyren som er beskrevet i ASTM D6195:<\/p>\n<p><strong data-start=\"2329\" data-end=\"2354\">1. Forberedelse av pr\u00f8ven<\/strong><\/p>\n<ul>\n<li data-start=\"2357\" data-end=\"2431\">\n<p data-start=\"2359\" data-end=\"2431\">Klipp til tre selvklebende strimler, hver p\u00e5 <strong data-start=\"2401\" data-end=\"2419\">25 mm \u00d7 125 mm<\/strong> (1\u2033 \u00d7 5\u2033)<\/p>\n<\/li>\n<li data-start=\"2432\" data-end=\"2537\">\n<p data-start=\"2434\" data-end=\"2537\">Hvis limet ikke har st\u00f8tte (f.eks. overf\u00f8ringstape), m\u00e5 det lamineres p\u00e5 2 mil PET-film f\u00f8r skj\u00e6ring.<\/p>\n<\/li>\n<li data-start=\"2538\" data-end=\"2619\">\n<p data-start=\"2540\" data-end=\"2619\">Konditioner alle pr\u00f8ver ved <strong data-start=\"2565\" data-end=\"2578\">23 \u00b1 2 \u00b0C<\/strong> og <strong data-start=\"2583\" data-end=\"2597\">50 \u00b1 5% RH<\/strong> i minst 24 timer<\/p>\n<\/li>\n<\/ul>\n<figure id=\"attachment_6978\" aria-describedby=\"caption-attachment-6978\" style=\"width: 298px\" class=\"wp-caption alignright\"><a href=\"http:\/\/https:\/\/www.celtec.cn\" rel=\"nofollow\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-6978\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.Loop-Tack-Tester-01-q_11zon-300x300.webp\" alt=\"Loop Tack Tester st\u00e5r for ASTM D6195\" width=\"298\" height=\"298\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.Loop-Tack-Tester-01-q_11zon-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.Loop-Tack-Tester-01-q_11zon-1024x1024.webp 1024w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.Loop-Tack-Tester-01-q_11zon-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.Loop-Tack-Tester-01-q_11zon-768x768.webp 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.Loop-Tack-Tester-01-q_11zon-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.Loop-Tack-Tester-01-q_11zon-600x600.webp 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.Loop-Tack-Tester-01-q_11zon-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.Loop-Tack-Tester-01-q_11zon.webp 1080w\" sizes=\"(max-width: 298px) 100vw, 298px\" \/><\/a><figcaption id=\"caption-attachment-6978\" class=\"wp-caption-text\">Loop Tack Tester st\u00e5r for ASTM D6195<\/figcaption><\/figure>\n<p data-start=\"2540\" data-end=\"2619\"><strong data-start=\"2621\" data-end=\"2644\">2. Rengj\u00f8ring av overflater<\/strong><\/p>\n<ul>\n<li data-start=\"2647\" data-end=\"2722\">\n<p data-start=\"2649\" data-end=\"2722\">Rengj\u00f8r testpanelet i rustfritt st\u00e5l med <strong data-start=\"2692\" data-end=\"2703\">aceton<\/strong> eller <strong data-start=\"2707\" data-end=\"2720\">n-heptan<\/strong><\/p>\n<\/li>\n<li data-start=\"2723\" data-end=\"2800\">\n<p data-start=\"2725\" data-end=\"2800\">Bruk <strong data-start=\"2729\" data-end=\"2748\">lofri v\u00e5tservietter<\/strong> og verifiser renheten ved hjelp av en <strong data-start=\"2780\" data-end=\"2800\">vannbruddstest<\/strong><\/p>\n<\/li>\n<\/ul>\n<p><strong data-start=\"2802\" data-end=\"2823\">3. Sl\u00f8yfedannelse<\/strong><\/p>\n<ul>\n<li data-start=\"2826\" data-end=\"2902\">\n<p data-start=\"2828\" data-end=\"2902\">Brett hver stripe forsiktig tilbake p\u00e5 seg selv for \u00e5 danne en <strong data-start=\"2876\" data-end=\"2900\">dr\u00e5peformet sl\u00f8yfe<\/strong><\/p>\n<\/li>\n<li data-start=\"2903\" data-end=\"2991\">\n<p data-start=\"2905\" data-end=\"2991\">Bruk <strong data-start=\"2909\" data-end=\"2932\">1-tommers maskeringstape<\/strong> for \u00e5 feste endene uten \u00e5 forurense klebeomr\u00e5det<\/p>\n<\/li>\n<\/ul>\n<p><strong data-start=\"2993\" data-end=\"3014\">4. Testgjennomf\u00f8ring<\/strong><\/p>\n<ul>\n<li data-start=\"3017\" data-end=\"3095\">\n<p data-start=\"3019\" data-end=\"3095\">Sett de teipede endene inn i <strong data-start=\"3050\" data-end=\"3065\">\u00f8vre klemme<\/strong> av <strong data-start=\"3073\" data-end=\"3093\">loop tack tester<\/strong><\/p>\n<\/li>\n<li data-start=\"3096\" data-end=\"3168\">\n<p data-start=\"3098\" data-end=\"3168\">Senk l\u00f8kken ned p\u00e5 en 1 in\u00b2 stor testflate av st\u00e5l med kontrollert hastighet<\/p>\n<\/li>\n<li data-start=\"3169\" data-end=\"3244\">\n<p data-start=\"3171\" data-end=\"3244\">Reverser retning og <strong data-start=\"3193\" data-end=\"3218\">registrere toppkraften<\/strong> n\u00f8dvendig for \u00e5 l\u00f8sne l\u00f8kken<\/p>\n<\/li>\n<\/ul>\n<p><strong data-start=\"3246\" data-end=\"3281\">5. Datainnsamling og analyse<\/strong><\/p>\n<ul data-start=\"3284\" data-end=\"3482\">\n<li data-start=\"3284\" data-end=\"3349\">\n<p data-start=\"3286\" data-end=\"3349\">Fang opp <strong data-start=\"3298\" data-end=\"3326\">maksimal separasjonskraft<\/strong> i Newton eller pund<\/p>\n<\/li>\n<li data-start=\"3350\" data-end=\"3424\">\n<p data-start=\"3352\" data-end=\"3424\">Ta opp <strong data-start=\"3363\" data-end=\"3379\">feilmodus<\/strong> (adhesjon, kohesjon eller limoverf\u00f8ring)<\/p>\n<\/li>\n<li data-start=\"3425\" data-end=\"3482\">\n<p data-start=\"3427\" data-end=\"3482\">Gjenta for alle pr\u00f8ver for \u00e5 sikre statistisk sikkerhet<\/p>\n<\/li>\n<\/ul>\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Sl\u00f8yfetest i henhold til ASTM D6195, PSTC-16, FINAT nr. 9.\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/L1HbDnq-LxQ?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<h2 data-start=\"3720\" data-end=\"3976\">Bruksomr\u00e5der og viktigheten av ASTM D6195 p\u00e5 tvers av bransjer<\/h2>\n<p data-start=\"3554\" data-end=\"3646\">Den <strong data-start=\"3558\" data-end=\"3572\">ASTM D6195<\/strong> loop tack-test er mye brukt i sektorer som er avhengige av PSA-ytelse:<\/p>\n<ul data-start=\"3648\" data-end=\"3987\">\n<li data-start=\"3648\" data-end=\"3715\">\n<p data-start=\"3650\" data-end=\"3715\"><strong data-start=\"3650\" data-end=\"3663\">Emballasje<\/strong>: Verifiserer rask klebrighet i forseglings- og bunteb\u00e5nd<\/p>\n<\/li>\n<li data-start=\"3716\" data-end=\"3811\">\n<p data-start=\"3718\" data-end=\"3811\"><strong data-start=\"3718\" data-end=\"3729\">Medisinsk<\/strong>: Bekrefter sk\u00e5nsom, men umiddelbar binding i s\u00e5rbandasjer og elektrodeplaster<\/p>\n<\/li>\n<li data-start=\"3812\" data-end=\"3897\">\n<p data-start=\"3814\" data-end=\"3897\"><strong data-start=\"3814\" data-end=\"3829\">Elektronikk<\/strong>: Sikrer sikker vedheft i etiketter, membraner eller midlertidige bindinger<\/p>\n<\/li>\n<li data-start=\"3898\" data-end=\"3987\">\n<p data-start=\"3900\" data-end=\"3987\"><strong data-start=\"3900\" data-end=\"3923\">Tekstil og kl\u00e6r<\/strong>: Evaluerer avtakbare tagger eller trykkf\u00f8lsomme designfunksjoner<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3989\" data-end=\"4180\">Ved \u00e5 m\u00e5le <em data-start=\"4006\" data-end=\"4017\">l\u00f8kkeheft<\/em>kan produsentene sammenligne formuleringer, justere beleggvekter og optimalisere overflatebehandlinger - noe som resulterer i mer p\u00e5litelige og h\u00f8ytytende limprodukter.<\/p>\n<h2 data-start=\"4238\" data-end=\"4279\">Forbedrer testn\u00f8yaktigheten med Cell Instruments' Loop Tack Tester<\/h2>\n<p data-start=\"4259\" data-end=\"4452\">For laboratorier og produksjonsmilj\u00f8er er det en fordel \u00e5 bruke en <strong data-start=\"4305\" data-end=\"4335\">dedikert loop tack-tester<\/strong>-som f.eks. <strong data-start=\"4348\" data-end=\"4380\">LTT-01 fra<a href=\"https:\/\/www.celtec.cn\" rel=\"nofollow noopener\" target=\"_blank\"> Cell Instruments<\/a><\/strong>-sikrer full overensstemmelse med <strong data-start=\"4410\" data-end=\"4433\">ASTM D6195 Metode B<\/strong>. Funksjoner inkluderer:<\/p>\n<ul data-start=\"4454\" data-end=\"4772\">\n<li data-start=\"4454\" data-end=\"4511\">\n<p data-start=\"4456\" data-end=\"4511\"><strong data-start=\"4456\" data-end=\"4485\">Digital kraftm\u00e5ling<\/strong> med 0,001 N oppl\u00f8sning<\/p>\n<\/li>\n<li data-start=\"4512\" data-end=\"4564\">\n<p data-start=\"4514\" data-end=\"4564\"><strong data-start=\"4514\" data-end=\"4544\">Programmerbar hastighetskontroll<\/strong> fra 1-500 mm\/min<\/p>\n<\/li>\n<li data-start=\"4565\" data-end=\"4630\">\n<p data-start=\"4567\" data-end=\"4630\"><strong data-start=\"4567\" data-end=\"4605\">Standardisert plate i rustfritt st\u00e5l<\/strong> for jevn kontakt<\/p>\n<\/li>\n<li data-start=\"4631\" data-end=\"4704\">\n<p data-start=\"4633\" data-end=\"4704\"><strong data-start=\"4633\" data-end=\"4675\">Grensesnitt med ber\u00f8ringsskjerm og mikroskriver<\/strong> for datafangst i sanntid<\/p>\n<\/li>\n<li data-start=\"4705\" data-end=\"4772\">\n<p data-start=\"4707\" data-end=\"4772\"><strong data-start=\"4707\" data-end=\"4740\">Valgfri programvareintegrasjon<\/strong> for testanalyse og arkivering<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4774\" data-end=\"4983\">LTT-01 er spesielt egnet for produsenter som arbeider med <strong data-start=\"4839\" data-end=\"4868\">trykkf\u00f8lsomme etiketter<\/strong>, <strong data-start=\"4870\" data-end=\"4887\">medisinske b\u00e5nd<\/strong>, og <strong data-start=\"4893\" data-end=\"4924\">industrielle beskyttelsesfilmer<\/strong>, der sl\u00f8yfens klebrighet er avgj\u00f8rende for produktets brukervennlighet.<\/p>\n<h3 data-start=\"4617\" data-end=\"4644\">Konklusjon<\/h3>\n<p data-start=\"5006\" data-end=\"5291\">Den <a href=\"https:\/\/www.qualitester.com\/nb\/standards\/astm-d6195\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5010\" data-end=\"5024\">ASTM D6195<\/strong><\/a> standard tilbyr en presis, repeterbar metode for \u00e5 evaluere <strong data-start=\"5086\" data-end=\"5114\">ytelse ved f\u00f8rste takling<\/strong> av trykkf\u00f8lsomme lim. Enten det brukes i h\u00f8yhastighetsemballasje, kliniske milj\u00f8er eller elektronikk, <strong data-start=\"5225\" data-end=\"5246\">testing av l\u00f8kkeklammer<\/strong> sikrer at limene oppfyller kravene til bruksomr\u00e5det.<\/p>\n<p data-start=\"5293\" data-end=\"5594\">Ved \u00e5 bruke en profesjonell<a href=\"https:\/\/www.qualitester.com\/nb\/produkt-2\/sale-tape-loop-tack-testing-machine\/\" target=\"_blank\" rel=\"noopener\"> <strong data-start=\"5318\" data-end=\"5338\">loop tack tester<\/strong><\/a> Som Cell Instruments' LTT-01 sikrer samsvar, konsistens og handlingsrettede data for produktoptimalisering og kvalitetskontroll. For bedrifter som er opptatt av limets p\u00e5litelighet, er det en smart og skalerbar investering \u00e5 integrere ASTM D6195 i QA-prosessen.<\/p>","protected":false},"excerpt":{"rendered":"<p>ASTM D6195 Testmetode for klebeevne ved loop-test For produsenter av trykkf\u00f8lsomme lim (PSA) er det avgj\u00f8rende \u00e5 oppn\u00e5 sterk innledende klebeevne \u2013 spesielt innen h\u00f8yhastighetsemballasje, medisinske teip, etiketter og industrielle filmer. Testmetoden ASTM D6195 tilbyr en standardisert tiln\u00e6rming til \u00e5 evaluere denne \u201cquick-stick\u201d-egenskapen. Den er spesielt utviklet for \u00e5 kvantifisere hvor godt et lim fester seg ved minimalt trykk og kort \u2026<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/nb\/standards\/astm-d6195-2\/\"> <span class=\"screen-reader-text\">ASTM D6195<\/span> Les mer \"<\/a><\/p>","protected":false},"author":3,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-6928","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/pages\/6928","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/comments?post=6928"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/pages\/6928\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/nb\/wp-json\/wp\/v2\/media?parent=6928"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}