{"id":3223,"date":"2023-08-07T08:52:04","date_gmt":"2023-08-07T00:52:04","guid":{"rendered":"https:\/\/www.qualitester.com\/?post_type=product&#038;p=3223"},"modified":"2024-12-04T16:01:26","modified_gmt":"2024-12-04T08:01:26","slug":"how-to-test-the-force-about-ampoule-breaking","status":"publish","type":"product","link":"https:\/\/www.qualitester.com\/lv\/products-2\/how-to-test-the-force-about-ampoule-breaking\/","title":{"rendered":"BST-01 Ampu\u013cu lau\u0161anas testeris"},"content":{"rendered":"<h2><strong>Ievads ampulu l\u016bzuma sp\u0113ka testera izmanto\u0161an\u0101<\/strong><\/h2>\n<p>Port\u0101ls <strong>ampulu l\u016bzuma sp\u0113ka test\u0113t\u0101js<\/strong> ir b\u016btisks instruments farm\u0101cijas un medic\u012bnisk\u0101s iepakojuma ra\u017eo\u0161anas nozar\u0113s, kas paredz\u0113ts, lai noteiktu sp\u0113ku, kas nepiecie\u0161ams, lai salauztu ampulas kakli\u0146u. Ampulas ir herm\u0113tiski nosl\u0113gtas tvertnes, kuras izmanto jut\u012bgu farmaceitisko vielu uzglab\u0101\u0161anai. Kakli\u0146a l\u016bzuma iztur\u012bba ir \u013coti svar\u012bga, lai nodro\u0161in\u0101tu iek\u0161\u0101 eso\u0161\u0101 produkta dro\u0161\u012bbu un integrit\u0101ti. Prec\u012bzs un uzticams test\u0113t\u0101js ir nepiecie\u0161ams, lai nodro\u0161in\u0101tu, ka ampulas atbilst nepiecie\u0161amajiem standartiem dro\u0161ai lieto\u0161anai un apstr\u0101dei.<\/p>\n<h2><strong>ISO 9187 izpratne: standarts ampulu l\u016bzuma sp\u0113ka test\u0113\u0161anai<\/strong><\/h2>\n<p><a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 9187<\/a> ir starptautisks standarts, kas nosaka ampulu l\u016bzuma sp\u0113ka p\u0101rbaudes metodi. Taj\u0101 sniegtas detaliz\u0113tas vadl\u012bnijas par to, k\u0101 j\u0101veic p\u0101rbaudes process, k\u0101 ar\u012b par nepiecie\u0161amo apr\u012bkojumu un m\u0113r\u0101majiem parametriem, lai nodro\u0161in\u0101tu konsekventus un prec\u012bzus rezult\u0101tus. Iev\u0113rojot ISO 9187, ra\u017eot\u0101ji var b\u016bt p\u0101rliecin\u0101ti, ka vi\u0146u ampulas atbilst dro\u0161\u012bbas pras\u012bb\u0101m, t\u0101d\u0113j\u0101di samazinot to l\u016b\u0161anas risku uzglab\u0101\u0161anas un p\u0101rvieto\u0161anas laik\u0101.<\/p>\n<h3><strong>P\u0101rbaudes metode saska\u0146\u0101 ar <a href=\"https:\/\/www.qualitester.com\/lv\/produkta-kategorija\/iso\/iso-9187\/\" target=\"_blank\" rel=\"noopener\">ISO 9187<\/a><\/strong><\/h3>\n<p>Test\u0101 ampulu novieto uz stiprin\u0101juma un, izmantojot test\u0113\u0161anas iek\u0101rtu, uz t\u0101s kakli\u0146a iedarbojas ar sp\u0113ku, kas v\u0113rsts uz leju. \u0160is <strong>BST-01 ampulu l\u016bzuma sp\u0113ka test\u0113t\u0101js<\/strong> izmanto augstas precizit\u0101tes slodzes dev\u0113ju, lai izm\u0113r\u012btu sp\u0113ku, kas nepiecie\u0161ams, lai salauztu ampulas kakli\u0146u. \u0160is tests nodro\u0161ina, ka ampulas ir ne tikai dro\u0161as lieto\u0161an\u0101, bet ar\u012b atbilst farmaceitiskaj\u0101m pras\u012bb\u0101m.<\/p>\n<h2><strong>Ampulu l\u016bzuma sp\u0113ka testera p\u0101rbaudes process<\/strong><\/h2>\n<ul>\n<li><strong>1. solis<\/strong>: Novietojiet ampulu uz speci\u0101la tur\u0113t\u0101ja, kas paredz\u0113ts da\u017e\u0101da izm\u0113ra ampul\u0101m (1 ml, 2 ml, 5 ml, 10 ml, 20 ml).<\/li>\n<li><strong>2. solis<\/strong>: Uzs\u0101ciet testu, kur\u0101 spiedgalvi\u0146a p\u0101rvietojas uz leju ar nemain\u012bgu \u0101trumu 10 mm\/min (regul\u0113jams diapazon\u0101 no 1 l\u012bdz 500 mm\/min).<\/li>\n<li><strong>3. solis<\/strong>: Augstas precizit\u0101tes slodzes dev\u0113js nosaka sp\u0113ku, kas nepiecie\u0161ams, lai salauztu ampulas kakli\u0146u.<\/li>\n<li><strong>4. solis<\/strong>: Tiek re\u0123istr\u0113ts p\u0101rr\u0101vuma sp\u0113ks, un rezult\u0101ti tiek par\u0101d\u012bti uz HMI sk\u0101rienekr\u0101na vai izdruk\u0101ti, izmantojot ieb\u016bv\u0113to mikroprinti.<\/li>\n<\/ul>\n<p>\u0160is process nodro\u0161ina, ka ampulu p\u0101rrau\u0161anas sp\u0113ks tiek prec\u012bzi izm\u0113r\u012bts saska\u0146\u0101 ar nozares standartiem.<\/p>\n<h2><strong>BST-01 ampulu iztur\u012bbas testera tehniskie raksturlielumi<\/strong><\/h2>\n<p>Port\u0101ls <strong>BST-01 ampulu iztur\u012bbas pret l\u016b\u0161anu test\u0113t\u0101js<\/strong> ir apr\u012bkots ar virkni modernu funkciju, kas uzlabo t\u0101 precizit\u0101ti un daudzpus\u012bbu:<\/p>\n<ul>\n<li><strong>Augstas precizit\u0101tes slodzes \u0161\u016bna<\/strong>: Nodro\u0161ina uzticamus un prec\u012bzus sp\u0113ka m\u0113r\u012bjumus ar iz\u0161\u0137irtsp\u0113ju 0,1 N.<\/li>\n<li><strong>Daudzveid\u012bgas iek\u0101rtu uzst\u0101d\u012b\u0161anas iesp\u0113jas<\/strong>: Test\u0113\u0161anas ier\u012bces 1 ml, 2 ml, 5 ml, 10 ml un 20 ml ampul\u0101m \u013cauj test\u0113t\u0101jam piel\u0101goties da\u017e\u0101da izm\u0113ra ampul\u0101m.<\/li>\n<li><strong>Regul\u0113jams testa \u0101trums<\/strong>: Test\u0113\u0161anas \u0101trumu var regul\u0113t diapazon\u0101 no 1 l\u012bdz 500 mm\/min, t\u0101d\u0113j\u0101di nodro\u0161inot atbilst\u012bbu da\u017e\u0101d\u0101m test\u0113\u0161anas pras\u012bb\u0101m.<\/li>\n<li><strong>PLC vad\u012bba un HMI sk\u0101rienj\u016bt\u012bgais ekr\u0101ns<\/strong>: Lai nodro\u0161in\u0101tu vienk\u0101r\u0161u darb\u012bbu un test\u0113\u0161anas procesa automatiz\u0101ciju.<\/li>\n<li><strong>So\u013cdzin\u0113js ar prec\u012bzu lod\u012b\u0161u v\u012btni<\/strong>: Nodro\u0161ina prec\u012bzu \u0101truma regul\u0113\u0161anu, lai veiktu prec\u012bzus testus.<\/li>\n<li><strong>Dro\u0161\u012bbas l\u012bdzek\u013ci<\/strong>: Komplekt\u0101 ietilpst aizsargp\u0101rsegs, kas nov\u0113r\u0161 parauga izl\u0113cienu, sav\u0101k\u0161anas caurule paraugiem no sapl\u012bsu\u0161\u0101m ampul\u0101m, k\u0101 ar\u012b autom\u0101tisk\u0101s atgrie\u0161anas funkcija.<\/li>\n<li><strong>Papildu savienojam\u012bbas iesp\u0113jas<\/strong>: RS-232 savienojam\u012bba integr\u0101cijai ar profesion\u0101lo programmat\u016bru un sist\u0113m\u0101m.<\/li>\n<\/ul>\n<h2><strong>Citi attiec\u012bgie standarti un atbilst\u012bba<\/strong><\/h2>\n<p>Papildus <strong>ISO 9187<\/strong>, un <strong>BST-01 ampulu l\u016bzuma sp\u0113ka test\u0113t\u0101js<\/strong> atbilst vair\u0101kiem citiem nozares standartiem, tostarp:<\/p>\n<ul>\n<li><strong>GB 2637<\/strong>: \u0136\u012bnas valsts standarts ampulu test\u0113\u0161anai.<\/li>\n<li><strong>YBB00332002<\/strong>: \u0136\u012bnas standarts ampul\u0101m, ko izmanto farmaceitisko izstr\u0101d\u0101jumu iepakojum\u0101.<\/li>\n<\/ul>\n<p>\u0160ie standarti nodro\u0161ina ier\u012bces daudzpus\u012bbu un atbilst\u012bbu starptautiskaj\u0101m test\u0113\u0161anas pras\u012bb\u0101m.<\/p>\n<h2><strong>Ampulu l\u016bzuma sp\u0113ka testera galvenie parametri<\/strong><\/h2>\n<table>\n<tbody>\n<tr>\n<td style=\"text-align: center;\" width=\"87\">Testa diapazons<\/td>\n<td style=\"text-align: center;\" width=\"188\">0 ~ 200 N (vai p\u0113c vajadz\u012bbas)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"87\">\u0100trums<\/td>\n<td style=\"text-align: center;\" width=\"188\">1 ~ 500 mm\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"87\">Rezol\u016bcija<\/td>\n<td style=\"text-align: center;\" width=\"188\">0,1 N<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"87\">Precizit\u0101te<\/td>\n<td style=\"text-align: center;\" width=\"188\">0,5% F.S.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"87\">Power<\/td>\n<td style=\"text-align: center;\" width=\"188\">110~ 220V 50\/60Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Port\u0101ls <strong>BST-01 ampulu l\u016bzuma sp\u0113ka test\u0113t\u0101js<\/strong> ir uzticams, daudzfunkcion\u0101ls un \u013coti prec\u012bzs ier\u012bce, kas izstr\u0101d\u0101ta, lai atbilstu farm\u0101cijas un medic\u012bnisk\u0101s iepakojuma ra\u017eo\u0161anas nozaru stingraj\u0101m test\u0113\u0161anas pras\u012bb\u0101m. Iev\u0113rojot starptautiskos standartus, piem\u0113ram, <strong>ISO 9187<\/strong>, test\u0113t\u0101js nodro\u0161ina, ka ampulas ir dro\u0161as lieto\u0161anai un atbilst nepiecie\u0161amaj\u0101m pras\u012bb\u0101m attiec\u012bb\u0101 uz salau\u0161anas sp\u0113ku. Pateicoties sav\u0101m modernaj\u0101m funkcij\u0101m, elast\u012bgumam da\u017e\u0101da izm\u0113ra ampulu test\u0113\u0161an\u0101 un vienk\u0101r\u0161ajai lieto\u0161anai, BST-01 ir neaizst\u0101jams r\u012bks ra\u017eot\u0101jiem un kvalit\u0101tes kontroles laboratorij\u0101m.<\/p>\n<h4><strong>Bie\u017e\u0101k uzdoto jaut\u0101jumu sada\u013ca<\/strong><\/h4>\n<ol>\n<li><strong>K\u0101ds ir ampulu l\u016bzuma sp\u0113ka testera m\u0113r\u0137is?<\/strong><br \/>\nTest\u0113t\u0101js m\u0113ra sp\u0113ku, kas nepiecie\u0161ams, lai salauztu ampulas kakli\u0146u, t\u0101d\u0113j\u0101di nodro\u0161inot t\u0101s iztur\u012bbu un dro\u0161\u012bbu apstr\u0101des un lieto\u0161anas laik\u0101.<\/li>\n<li><strong>K\u0101da ir ISO 9187 saist\u012bba ar ampulu test\u0113\u0161anu?<\/strong><br \/>\nStandarts ISO 9187 nosaka ampulu l\u016bzuma sp\u0113ka p\u0101rbaudes metodi un vadl\u012bnijas, nodro\u0161inot p\u0101rbaudes procesa konsekvenci un uzticam\u012bbu.<\/li>\n<li><strong>K\u0101das ir galven\u0101s tehnisk\u0101s \u012bpa\u0161\u012bbas BST-01 ampulu l\u016bzuma sp\u0113ka test\u0113t\u0101jam?<\/strong><br \/>\nTest\u0113t\u0101jam ir augstas precizit\u0101tes slodzes dev\u0113js, da\u017e\u0101da izm\u0113ra stiprin\u0101jumi, regul\u0113jami test\u0113\u0161anas \u0101trumi, PLC vad\u012bba, k\u0101 ar\u012b dro\u0161\u012bbas funkcijas, piem\u0113ram, aizsargp\u0101rsegi un sav\u0101k\u0161anas caurules.<\/li>\n<li><strong>Vai BST-01 var izmantot citu materi\u0101lu p\u0101rbaudei, ne tikai ampul\u0101m?<\/strong><br \/>\nJ\u0101, BST-01 ir univers\u0101ls un ar to var p\u0101rbaud\u012bt ar\u012b citus medic\u012bniskos iepakojuma materi\u0101lus, piem\u0113ram, \u0161\u013circes, v\u0101ci\u0146us un aizb\u0101\u017e\u0146us.<\/li>\n<li><strong>K\u0101da ir BST-01 ampulu l\u016bzuma sp\u0113ka testera precizit\u0101te?<\/strong><br \/>\nTesteris nodro\u0161ina precizit\u0101ti 0,51 TP3T no pilnas skalas (F.S.), t\u0101d\u0113j\u0101di garant\u0113jot prec\u012bzus un uzticamus test\u0113\u0161anas rezult\u0101tus.<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Port\u0101ls <strong>ampulu l\u016bzuma sp\u0113ka test\u0113t\u0101js<\/strong> ir b\u016btisks instruments farm\u0101cijas un medic\u012bnisk\u0101s iepakojuma ra\u017eo\u0161anas nozar\u0113s, kas paredz\u0113ts, lai noteiktu sp\u0113ku, kas nepiecie\u0161ams, lai salauztu ampulas kakli\u0146u. Ampulas ir herm\u0113tiski nosl\u0113gtas tvertnes, kuras izmanto jut\u012bgu farmaceitisko vielu uzglab\u0101\u0161anai. Kakli\u0146a l\u016bzuma iztur\u012bba ir \u013coti svar\u012bga, lai nodro\u0161in\u0101tu iek\u0161\u0101 eso\u0161\u0101 produkta dro\u0161\u012bbu un integrit\u0101ti. Prec\u012bzs un uzticams test\u0113t\u0101js ir nepiecie\u0161ams, lai nodro\u0161in\u0101tu, ka ampulas atbilst nepiecie\u0161amajiem standartiem dro\u0161ai lieto\u0161anai un apstr\u0101dei.<\/p>","protected":false},"featured_media":6120,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":""},"product_cat":[933,845,149,173,95],"product_tag":[],"class_list":["post-3223","product","type-product","status-publish","has-post-thumbnail","product_cat-ampoule-breaking-tester","product_cat-customization","product_cat-pharma-and-medical-testers","product_cat-iso-9187","product_cat-products","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/product\/3223","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/comments?post=3223"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/product\/3223\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/media\/6120"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/media?parent=3223"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/product_cat?post=3223"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/product_tag?post=3223"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}