{"id":7956,"date":"2026-05-07T15:44:25","date_gmt":"2026-05-07T07:44:25","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7956"},"modified":"2026-05-07T16:19:47","modified_gmt":"2026-05-07T08:19:47","slug":"iso-8537","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/lv\/standards\/iso-8537\/","title":{"rendered":"ISO 8537"},"content":{"rendered":"<p data-start=\"397\" data-end=\"745\">Standarts ISO 8537 nosaka kritiskos veiktsp\u0113jas testus steriliem vienreizlietojamiem insul\u012bna \u0161\u013circes, tostarp injic\u0113jam\u012bbu, \u0161\u013circes nopl\u016bdi, iztur\u012bbu pret vakuuma nopl\u016bdi, sl\u012bd\u0113\u0161anas sp\u0113ku un miru\u0161\u0101 tilpuma m\u0113r\u012bjumus. \u0160ie testi nov\u0113rt\u0113 herm\u0113tiskumu, virzu\u013ca darb\u012bbas sp\u0113ku, aspir\u0101cijas veiktsp\u0113ju un atliku\u0161\u0101 tilpuma precizit\u0101ti, lai nodro\u0161in\u0101tu \u0161\u013circes dro\u0161\u012bbu un devas noteik\u0161anas uzticam\u012bbu. Modernas test\u0113\u0161anas sist\u0113mas pal\u012bdz ra\u017eot\u0101jiem nodro\u0161in\u0101t konsekventu kvalit\u0101tes kontroli, atbilst\u012bbu normat\u012bvaj\u0101m pras\u012bb\u0101m un uzlabotu produktu veiktsp\u0113ju farm\u0101cijas un medic\u012bnas ier\u012b\u010du lietojumos.<\/p>\n<p data-start=\"397\" data-end=\"745\">Steril\u0101m insul\u012bna \u0161\u013circ\u0113m kl\u012bnisk\u0101s lieto\u0161anas laik\u0101 j\u0101nodro\u0161ina prec\u012bzas devas, j\u0101uztur herm\u0113tiskums un j\u0101nodro\u0161ina vienm\u0113r\u012bga virzu\u013ca kust\u012bba. <strong data-start=\"535\" data-end=\"547\">ISO 8537<\/strong>, starptautiskais standarts steriliem vienreizlietojamiem insul\u012bna \u0161\u013circes ar vai bez adat\u0101m, nosaka ra\u017eot\u0101jiem un kvalit\u0101tes kontroles laboratorij\u0101m oblig\u0101t\u0101s darb\u012bbas un dro\u0161\u012bbas pras\u012bbas.<\/p>\n<p data-start=\"747\" data-end=\"1121\">Standarts ietver vair\u0101kus b\u016btiskus funkcion\u0101los nov\u0113rt\u0113jumus, piem\u0113ram, <strong data-start=\"823\" data-end=\"845\">ievad\u0101m\u012bbas tests<\/strong>, <strong data-start=\"847\" data-end=\"871\">\u0161\u013circes nopl\u016bdes p\u0101rbaude<\/strong>, <strong data-start=\"873\" data-end=\"908\">vakuuma nopl\u016bdes p\u0101rbaude farm\u0101cijas nozar\u0113<\/strong>, <strong data-start=\"910\" data-end=\"941\">\u0161\u013circes sl\u012bd\u0113\u0161anas sp\u0113ka test\u0113\u0161ana<\/strong>, un <strong data-start=\"947\" data-end=\"973\">neizmantot\u0101s telpas m\u0113r\u012b\u0161ana<\/strong>. \u0160ie testi pal\u012bdz ra\u017eot\u0101jiem p\u0101rbaud\u012bt \u0161\u013cir\u010du uzticam\u012bbu, samazin\u0101t devu noteik\u0161anas k\u013c\u016bdas un nodro\u0161in\u0101t atbilst\u012bbu starptautiskajiem medic\u012bnisko ier\u012b\u010du noteikumiem.<\/p>\n<h2 data-section-id=\"3lxdx6\" data-start=\"1322\" data-end=\"1380\">ISO 8537. Pras\u012bbas \u0161\u013cir\u010du kvalit\u0101tei<\/h2>\n<p data-start=\"1382\" data-end=\"1497\">Standarts ISO 8537 ir velt\u012bts sterilu vienreizlietojamo insul\u012bna \u0161\u013cir\u010du darb\u012bbas raksturlielumiem. Standarts nov\u0113rt\u0113:<\/p>\n<ul data-start=\"1499\" data-end=\"1705\">\n<li data-section-id=\"km50lt\" data-start=\"1499\" data-end=\"1523\">Gaisa nopl\u016bdes pretest\u012bba<\/li>\n<li data-section-id=\"413t8n\" data-start=\"1524\" data-end=\"1551\">Iztur\u012bba pret \u0161\u0137idruma nopl\u016bdi<\/li>\n<li data-section-id=\"fak85b\" data-start=\"1552\" data-end=\"1576\">Virzu\u013ca darb\u012bbas sp\u0113ks<\/li>\n<li data-section-id=\"1iislmh\" data-start=\"1577\" data-end=\"1617\">Adatas un sprauslas savienojuma herm\u0113tiskums<\/li>\n<li data-section-id=\"w4478w\" data-start=\"1618\" data-end=\"1648\">Atliku\u0161ais tilpums (miru\u0161ais tilpums)<\/li>\n<li data-section-id=\"1pxb9hs\" data-start=\"1649\" data-end=\"1705\">Konstrukcijas integrit\u0101te aspir\u0101cijas un saspie\u0161anas laik\u0101<\/li>\n<\/ul>\n<p data-start=\"1707\" data-end=\"1816\">\u0160ie darb\u012bbas r\u0101d\u012bt\u0101ji tie\u0161i ietekm\u0113 injekcijas precizit\u0101ti, sterilit\u0101tes nodro\u0161in\u0101\u0161anu un lietot\u0101ja pieredzi.<\/p>\n<p data-start=\"1818\" data-end=\"2034\">At\u0161\u0137ir\u012bb\u0101 no vienk\u0101r\u0161\u0101m vizu\u0101l\u0101m p\u0101rbaud\u0113m, ISO 8537 test\u0113\u0161anai ir nepiecie\u0161amas kontrol\u0113tas laboratorijas proced\u016bras un prec\u012bzi m\u0113rinstrumenti, kas sp\u0113j rad\u012bt atk\u0101rtojamu meh\u0101nisko sp\u0113ku, vakuuma spiedienu un nodro\u0161in\u0101t m\u0113r\u012bjumu precizit\u0101ti.<\/p>\n<h2 data-section-id=\"rfstg1\" data-start=\"2041\" data-end=\"2084\">Ievad\u0101m\u012bbas tests saska\u0146\u0101 ar standartu ISO 8537<\/h2>\n<p data-start=\"2086\" data-end=\"2328\">Port\u0101ls <strong data-start=\"2090\" data-end=\"2112\">ievad\u0101m\u012bbas tests<\/strong> nov\u0113rt\u0113 darb\u012bbas sp\u0113ku, kas nepiecie\u0161ams, lai uzs\u0101ktu un uztur\u0113tu virzu\u013ca kust\u012bbu \u0161\u0137idruma padeves laik\u0101. Saska\u0146\u0101 ar ISO 8537 C pielikumu pirms test\u0113\u0161anas \u0161\u013circi piepilda ar destil\u0113tu \u016bdeni l\u012bdz 50% no t\u0101s nomin\u0101l\u0101s ietilp\u012bbas.<\/p>\n<p data-start=\"2330\" data-end=\"2377\">\u0160\u012b proced\u016bra m\u0113ra divus b\u016btiskus parametrus:<\/p>\n<ul data-start=\"2379\" data-end=\"2530\">\n<li data-section-id=\"psx7ug\" data-start=\"2379\" data-end=\"2457\"><strong data-start=\"2381\" data-end=\"2402\">Atbr\u012bvojo\u0161ais sp\u0113ks<\/strong> \u2014 s\u0101kotn\u0113jais sp\u0113ks, kas nepiecie\u0161ams, lai uzs\u0101ktu virzuli kust\u012bbu<\/li>\n<li data-section-id=\"x7byum\" data-start=\"2458\" data-end=\"2530\"><strong data-start=\"2460\" data-end=\"2475\">Sl\u012bd\u0113\u0161anas sp\u0113ks<\/strong> \u2014 past\u0101v\u012bgais sp\u0113ks, kas nepiecie\u0161ams, lai uztur\u0113tu virzu\u013ca kust\u012bbu<\/li>\n<\/ul>\n<p data-start=\"2532\" data-end=\"2561\">P\u0101rm\u0113r\u012bga sp\u0113ka pielieto\u0161ana var liecin\u0101t par:<\/p>\n<ul data-start=\"2562\" data-end=\"2680\">\n<li data-section-id=\"165iqxg\" data-start=\"2562\" data-end=\"2580\">Nepietiekama e\u013c\u013co\u0161ana<\/li>\n<li data-section-id=\"qnjztr\" data-start=\"2581\" data-end=\"2610\">Defekt\u012bvi elastom\u0113ra bl\u012bv\u0113jumi<\/li>\n<li data-section-id=\"19shynq\" data-start=\"2611\" data-end=\"2645\">Mucas izm\u0113ru neatbilst\u012bba<\/li>\n<li data-section-id=\"z1rwsc\" data-start=\"2646\" data-end=\"2680\">Nepietiekama ra\u017eo\u0161anas kontrole<\/li>\n<\/ul>\n<p data-start=\"2682\" data-end=\"2763\">Nepietiekama sp\u0113ka pielieto\u0161ana var samazin\u0101t doz\u0113\u0161anas precizit\u0101ti un apdraud\u0113t apstr\u0101des stabilit\u0101ti.<\/p>\n<h3 data-start=\"2981\" data-end=\"3195\"><a href=\"https:\/\/www.qualitester.com\/lv\/products-2\/syringe-piston-glide-force-tester\/\" target=\"_blank\" rel=\"noopener\">SSR-01 \u0160\u013circes sl\u012bd\u0113\u0161anas pretest\u012bbas test\u0113t\u0101js<\/a><\/h3>\n<p><a href=\"https:\/\/www.qualitester.com\/lv\/products-2\/syringe-piston-glide-force-tester\/\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-6642 size-medium\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/Syringe-Piston-Glide-Force-Tester-ISO-7886-1-Annex-E-300x300.webp\" alt=\"\u0160\u013circes virzuli sl\u012bd\u0113\u0161anas sp\u0113ka test\u0113t\u0101js \u2014 ISO 7886-1 E pielikums\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/Syringe-Piston-Glide-Force-Tester-ISO-7886-1-Annex-E-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/Syringe-Piston-Glide-Force-Tester-ISO-7886-1-Annex-E-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/Syringe-Piston-Glide-Force-Tester-ISO-7886-1-Annex-E-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/Syringe-Piston-Glide-Force-Tester-ISO-7886-1-Annex-E-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/Syringe-Piston-Glide-Force-Tester-ISO-7886-1-Annex-E.webp 600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<h2 data-section-id=\"1sgck7w\" data-start=\"3202\" data-end=\"3251\">\u0160\u013circes nopl\u016bdes p\u0101rbaude, lai p\u0101rliecin\u0101tos par t\u0101s herm\u0113tiskumu<\/h2>\n<p data-start=\"3253\" data-end=\"3383\">Port\u0101ls <strong data-start=\"3257\" data-end=\"3281\">\u0161\u013circes nopl\u016bdes p\u0101rbaude<\/strong> kas aprakst\u012bta ISO 8537 E pielikum\u0101, p\u0101rbauda \u0161\u0137idruma necaurlaid\u012bbu iek\u0161\u0113j\u0101 spiediena apst\u0101k\u013cos.<\/p>\n<p data-start=\"3385\" data-end=\"3406\">Proced\u016bras laik\u0101:<\/p>\n<ol data-start=\"3407\" data-end=\"3646\">\n<li data-section-id=\"1gqsp1l\" data-start=\"3407\" data-end=\"3455\">\u0160\u013circe ir piepild\u012bta p\u0101rsniedzot nomin\u0101lo tilpumu.<\/li>\n<li data-section-id=\"1tw1yle\" data-start=\"3456\" data-end=\"3486\">Gaiss ir piln\u012bb\u0101 izlaists.<\/li>\n<li data-section-id=\"139f7ck\" data-start=\"3487\" data-end=\"3525\">Sprausla vai adatas gals ir nosl\u0113gts.<\/li>\n<li data-section-id=\"1w1iqbn\" data-start=\"3526\" data-end=\"3589\">Lai pan\u0101ktu maksim\u0101lu virzuli novirzi, tiek pielikta s\u0101nu slodze.<\/li>\n<li data-section-id=\"jl8kyz\" data-start=\"3590\" data-end=\"3646\">Iek\u0161\u0113jais spiediens sasniedz <strong data-start=\"3619\" data-end=\"3630\">300 kPa<\/strong> 30 sekundes.<\/li>\n<\/ol>\n<p data-start=\"3648\" data-end=\"3675\">Tad operators p\u0101rbauda:<\/p>\n<ul data-start=\"3676\" data-end=\"3777\">\n<li data-section-id=\"1v1bjqk\" data-start=\"3676\" data-end=\"3697\">V\u0101rsta bl\u012bv\u0113juma nopl\u016bde<\/li>\n<li data-section-id=\"bqbg1c\" data-start=\"3698\" data-end=\"3718\">Nopl\u016bde no sprauslas\/savienojuma<\/li>\n<li data-section-id=\"e0n55p\" data-start=\"3719\" data-end=\"3748\">Nopl\u016bde adatas un cilindra savienojum\u0101<\/li>\n<li data-section-id=\"12599qq\" data-start=\"3749\" data-end=\"3777\">Neparedz\u0113ta virzu\u013ca kust\u012bba<\/li>\n<\/ul>\n<p data-start=\"3779\" data-end=\"3897\">\u0160is tests imit\u0113 re\u0101lus kl\u012bniskos ekspluat\u0101cijas apst\u0101k\u013cus, kuros vienlaikus var rasties s\u0101nu slodzes un iek\u0161\u0113jais spiediens.<\/p>\n<p data-start=\"3899\" data-end=\"3932\">Nopl\u016bdes var rasties \u0161\u0101du iemeslu d\u0113\u013c:<\/p>\n<ul data-start=\"3933\" data-end=\"4042\">\n<li data-section-id=\"1hlhp7v\" data-start=\"3933\" data-end=\"3957\">Nepietiekama elastom\u0113ra bl\u012bv\u0113juma efektivit\u0101te<\/li>\n<li data-section-id=\"1ls3zqh\" data-start=\"3958\" data-end=\"3989\">Neprec\u012bzas lie\u0161anas pielaides<\/li>\n<li data-section-id=\"1ho49jl\" data-start=\"3990\" data-end=\"4009\">V\u0101j\u0161 rumbas mezgls<\/li>\n<li data-section-id=\"bxum84\" data-start=\"4010\" data-end=\"4042\">Nepietiekama sa\u0137ere<\/li>\n<\/ul>\n<h3 data-start=\"4236\" data-end=\"4373\"><a href=\"https:\/\/www.qualitester.com\/lv\/products-2\/syringe-liquid-leakage-tester\/\" target=\"_blank\" rel=\"noopener\">SPPT-01 \u0160\u013circes \u0161\u0137idruma nopl\u016bdes test\u0113t\u0101js<\/a><\/h3>\n<p><img decoding=\"async\" class=\"size-medium wp-image-6634\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SPPT-01-ISO-7886-1-Syringe-Liquid-Leakage-Tester-300x300.jpg\" alt=\"SPPT-01 ISO 7886-1 \u0161\u013circes \u0161\u0137idruma nopl\u016bdes test\u0113t\u0101js\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SPPT-01-ISO-7886-1-Syringe-Liquid-Leakage-Tester-300x300.jpg 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SPPT-01-ISO-7886-1-Syringe-Liquid-Leakage-Tester-150x150.jpg 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SPPT-01-ISO-7886-1-Syringe-Liquid-Leakage-Tester-768x768.jpg 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SPPT-01-ISO-7886-1-Syringe-Liquid-Leakage-Tester-12x12.jpg 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SPPT-01-ISO-7886-1-Syringe-Liquid-Leakage-Tester-600x600.jpg 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SPPT-01-ISO-7886-1-Syringe-Liquid-Leakage-Tester-100x100.jpg 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SPPT-01-ISO-7886-1-Syringe-Liquid-Leakage-Tester.jpg 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h2 data-section-id=\"1i0hskc\" data-start=\"4380\" data-end=\"4439\">Vakuuma nopl\u016bdes p\u0101rbaude farm\u0101cijas nozar\u0113 saska\u0146\u0101 ar standartu ISO 8537<\/h2>\n<p data-start=\"4441\" data-end=\"4575\">Port\u0101ls <strong data-start=\"4445\" data-end=\"4480\">vakuuma nopl\u016bdes p\u0101rbaude farm\u0101cijas nozar\u0113<\/strong> ISO 8537 B pielikum\u0101 aprakst\u012bt\u0101 proced\u016bra nov\u0113rt\u0113 gaisa nopl\u016bdi gar \u0161\u013circes virzuli aspir\u0101cijas laik\u0101.<\/p>\n<p data-start=\"4577\" data-end=\"4763\">\u0160\u013circe ir da\u013c\u0113ji piepild\u012bta ar destil\u0113tu \u016bdeni un savienota ar etalona konisko savienot\u0101juzmavu. Sist\u0113ma pak\u0101peniski rada vakuumu, kas sasniedz <strong data-start=\"4725\" data-end=\"4762\">88 kPa zem atmosf\u0113ras spiediena<\/strong>.<\/p>\n<p data-start=\"4765\" data-end=\"4783\">P\u0113c tam eksamin\u0113t\u0101js:<\/p>\n<ul data-start=\"4784\" data-end=\"4918\">\n<li data-section-id=\"p6yoi4\" data-start=\"4784\" data-end=\"4810\">P\u0101rbauda, vai nav gaisa nopl\u016bdes<\/li>\n<li data-section-id=\"s0iwov\" data-start=\"4811\" data-end=\"4855\">Nodro\u0161ina spiediena stabilit\u0101ti 60 sekundes<\/li>\n<li data-section-id=\"jv7vas\" data-start=\"4856\" data-end=\"4918\">P\u0101rbauda, vai gumijas aizb\u0101znis atdal\u0101s no virzuli<\/li>\n<\/ul>\n<p data-start=\"4920\" data-end=\"5004\">\u0160is tests ir \u012bpa\u0161i svar\u012bgs, jo aspir\u0101cijas efektivit\u0101te tie\u0161i ietekm\u0113:<\/p>\n<ul data-start=\"5005\" data-end=\"5102\">\n<li data-section-id=\"17ofnkc\" data-start=\"5005\" data-end=\"5030\">Prec\u012bza insul\u012bna devas noteik\u0161ana<\/li>\n<li data-section-id=\"1vsyzsa\" data-start=\"5031\" data-end=\"5054\">Gaisa burbu\u013cu nov\u0113r\u0161ana<\/li>\n<li data-section-id=\"4bkl5w\" data-start=\"5055\" data-end=\"5078\">Sterilit\u0101tes nodro\u0161in\u0101\u0161ana<\/li>\n<li data-section-id=\"6gyd3l\" data-start=\"5079\" data-end=\"5102\">Ievad\u012b\u0161anas konsistence<\/li>\n<\/ul>\n<p data-start=\"5104\" data-end=\"5180\">Stabils vakuums bez spiediena krituma liecina par efekt\u012bvu bl\u012bv\u0113juma integrit\u0101ti.<\/p>\n<h3 data-start=\"5370\" data-end=\"5466\"><a href=\"https:\/\/www.qualitester.com\/lv\/products-2\/syringe-air-leakage-tester-iso-7886-1\/\" target=\"_blank\" rel=\"noopener\">SLT-02 \u0160\u013circes gaisa nopl\u016bdes test\u0113t\u0101js<\/a><\/h3>\n<p data-start=\"2981\" data-end=\"3195\"><a href=\"https:\/\/www.qualitester.com\/lv\/products-2\/syringe-air-leakage-tester-iso-7886-1\/\"><img decoding=\"async\" class=\"wp-image-6628 size-medium\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SLT-02-Syringe-Air-Leakage-Tester-ISO-7886-1-300x300.jpg\" alt=\"SLT-02 \u0160\u013circes gaisa nopl\u016bdes test\u0113t\u0101js \u2014 ISO 7886-1\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SLT-02-Syringe-Air-Leakage-Tester-ISO-7886-1-300x300.jpg 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SLT-02-Syringe-Air-Leakage-Tester-ISO-7886-1-150x150.jpg 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SLT-02-Syringe-Air-Leakage-Tester-ISO-7886-1-12x12.jpg 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SLT-02-Syringe-Air-Leakage-Tester-ISO-7886-1-100x100.jpg 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/04\/SLT-02-Syringe-Air-Leakage-Tester-ISO-7886-1.jpg 600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<h2 data-section-id=\"1a8ay7g\" data-start=\"5473\" data-end=\"5526\">\u0160\u013circes sl\u012bd\u0113\u0161anas sp\u0113ka test\u0113\u0161ana, lai nov\u0113rt\u0113tu virzu\u013ca darb\u012bbu<\/h2>\n<p data-start=\"5528\" data-end=\"5642\"><strong data-start=\"5528\" data-end=\"5559\">\u0160\u013circes sl\u012bd\u0113\u0161anas sp\u0113ka test\u0113\u0161ana<\/strong> ir viens no svar\u012bg\u0101kajiem lietojam\u012bbas nov\u0113rt\u0113jumiem, veicot atbilst\u012bbas p\u0101rbaudi saska\u0146\u0101 ar standartu ISO 8537.<\/p>\n<p data-start=\"5644\" data-end=\"5673\">Vienm\u0113r\u012bga virzu\u013ca kust\u012bba nodro\u0161ina:<\/p>\n<ul data-start=\"5674\" data-end=\"5787\">\n<li data-section-id=\"181tqit\" data-start=\"5674\" data-end=\"5708\">\u0112rta injekcijas veik\u0161ana<\/li>\n<li data-section-id=\"rk7z4p\" data-start=\"5709\" data-end=\"5739\">Prec\u012bza z\u0101\u013cu pieg\u0101de<\/li>\n<li data-section-id=\"mf38ad\" data-start=\"5740\" data-end=\"5764\">Stabils iesmidzin\u0101\u0161anas \u0101trums<\/li>\n<li data-section-id=\"1rflcw2\" data-start=\"5765\" data-end=\"5787\">Maz\u0101ks roku nogurums<\/li>\n<\/ul>\n<p data-start=\"5789\" data-end=\"5878\">Test\u0101 tiek re\u0123istr\u0113ts nep\u0101rtraukts sp\u0113ka profils, kam\u0113r virzulis p\u0101rvietojas pa cilindru.<\/p>\n<p data-start=\"5880\" data-end=\"5906\">Tipisk\u0101 anal\u012bze ietver:<\/p>\n<ul data-start=\"5907\" data-end=\"5992\">\n<li data-section-id=\"3d9wpq\" data-start=\"5907\" data-end=\"5928\">Maksim\u0101l\u0101 plan\u0113\u0161anas sp\u0113ks<\/li>\n<li data-section-id=\"fj68np\" data-start=\"5929\" data-end=\"5950\">Vid\u0113j\u0101 plan\u0113\u0161anas pretest\u012bba<\/li>\n<li data-section-id=\"1equdqt\" data-start=\"5951\" data-end=\"5970\">Sp\u0113ka sv\u0101rst\u012bbas<\/li>\n<li data-section-id=\"sf8nbd\" data-start=\"5971\" data-end=\"5992\">\u201eStick-slip\u201d par\u0101d\u012bba<\/li>\n<\/ul>\n<p data-start=\"5994\" data-end=\"6032\">Neregul\u0101ras sp\u0113ka l\u012bknes bie\u017ei liecina par:<\/p>\n<ul data-start=\"6033\" data-end=\"6144\">\n<li data-section-id=\"1rxq1ai\" data-start=\"6033\" data-end=\"6067\">Probl\u0113mas ar silikona e\u013c\u013cas sadali<\/li>\n<li data-section-id=\"15d0d3\" data-start=\"6068\" data-end=\"6095\">Virsmas raupjuma defekti<\/li>\n<li data-section-id=\"13y0btp\" data-start=\"6096\" data-end=\"6116\">Virzu\u013ca deform\u0101cija<\/li>\n<li data-section-id=\"1ysw8ll\" data-start=\"6117\" data-end=\"6144\">Stobra \u0123eometrijas izmai\u0146as<\/li>\n<\/ul>\n<p data-start=\"6146\" data-end=\"6365\">Uz\u0146\u0113mums \u201eCell Instruments\u201c pied\u0101v\u0101 sp\u0113ka test\u0113\u0161anas sist\u0113mas, kas sp\u0113j re\u0101llaik\u0101 \u0123ener\u0113t sp\u0113ka\u2013p\u0101rvietojuma l\u012bknes, lai veiktu detaliz\u0113tu \u0161\u013cir\u010du darb\u012bbas anal\u012bzi. \u0160\u012bs sist\u0113mas atbalsta p\u0113tniec\u012bbas un att\u012bst\u012bbas optimiz\u0101ciju, k\u0101 ar\u012b partiju kvalit\u0101tes p\u0101rbaudi.<\/p>\n<h3 data-start=\"6146\" data-end=\"6365\"><a href=\"https:\/\/www.qualitester.com\/lv\/products-2\/sale-syringe-plunger-glide-force-tester\/\" target=\"_blank\" rel=\"noopener\">MST-01 Medic\u012bnas \u0161\u013cir\u010du testeris<\/a><\/h3>\n<p data-start=\"6146\" data-end=\"6365\"><a href=\"https:\/\/www.qualitester.com\/lv\/products-2\/sale-syringe-plunger-glide-force-tester\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-5116 size-medium\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2024\/10\/MST-01-Syringe-Plunger-Glide-Force-Tester-03-300x300.jpg\" alt=\"MST-01 \u0160\u013circes virzuli sl\u012bd\u0113\u0161anas sp\u0113ka test\u0113t\u0101js 03\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2024\/10\/MST-01-Syringe-Plunger-Glide-Force-Tester-03-300x300.jpg 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2024\/10\/MST-01-Syringe-Plunger-Glide-Force-Tester-03-150x150.jpg 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2024\/10\/MST-01-Syringe-Plunger-Glide-Force-Tester-03-600x600.jpg 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2024\/10\/MST-01-Syringe-Plunger-Glide-Force-Tester-03-100x100.jpg 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2024\/10\/MST-01-Syringe-Plunger-Glide-Force-Tester-03.jpg 750w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<h2 data-section-id=\"sepro\" data-start=\"6372\" data-end=\"6409\">Miru\u0161\u0101s telpas m\u0113r\u012b\u0161ana saska\u0146\u0101 ar standartu ISO 8537<\/h2>\n<p data-start=\"6411\" data-end=\"6538\"><strong data-start=\"6411\" data-end=\"6437\">Tuk\u0161\u0101s telpas m\u0113r\u012b\u0161ana<\/strong> nosaka atliku\u0161o \u0161\u0137idruma tilpumu, kas paliek \u0161\u013circes iek\u0161ien\u0113 p\u0113c virzuli piln\u012bb\u0101 nospie\u017eot.<\/p>\n<p data-start=\"6540\" data-end=\"6582\">ISO 8537 D pielikum\u0101 neakt\u012bv\u0101 telpa tiek noteikta \u0161\u0101di:<\/p>\n<ol data-start=\"6583\" data-end=\"6756\">\n<li data-section-id=\"5n54cf\" data-start=\"6583\" data-end=\"6612\">Tuk\u0161as \u0161\u013circes sv\u0113r\u0161ana<\/li>\n<li data-section-id=\"1po99wn\" data-start=\"6613\" data-end=\"6656\">\u0160\u013circes piepild\u012b\u0161ana ar destil\u0113tu \u016bdeni<\/li>\n<li data-section-id=\"1rejvy1\" data-start=\"6657\" data-end=\"6691\">\u0160\u0137idruma piln\u012bga izs\u016bkn\u0113\u0161ana<\/li>\n<li data-section-id=\"1w7zx7c\" data-start=\"6692\" data-end=\"6717\">\u0160\u013circes atk\u0101rtota nosv\u0113r\u0161ana<\/li>\n<li data-section-id=\"1syj61a\" data-start=\"6718\" data-end=\"6756\">Atliku\u0161\u0101s \u016bdens masas apr\u0113\u0137in\u0101\u0161ana<\/li>\n<\/ol>\n<p data-start=\"6758\" data-end=\"6789\">Mazs neizmantotais tilpums ir \u013coti svar\u012bgs:<\/p>\n<ul data-start=\"6790\" data-end=\"6871\">\n<li data-section-id=\"17ofnkc\" data-start=\"6790\" data-end=\"6815\">Prec\u012bza insul\u012bna devas noteik\u0161ana<\/li>\n<li data-section-id=\"1015ofw\" data-start=\"6816\" data-end=\"6836\">Z\u0101\u013cu atkritumu samazin\u0101\u0161ana<\/li>\n<li data-section-id=\"1u8enyk\" data-start=\"6837\" data-end=\"6871\">Uzlabota terapijas konsekvence<\/li>\n<\/ul>\n<p data-start=\"6873\" data-end=\"6979\">\u0160is parametrs k\u013c\u016bst \u012bpa\u0161i svar\u012bgs d\u0101rgiem biolo\u0123iskajiem prepar\u0101tiem un zemu devu injic\u0113jamiem prepar\u0101tiem.<\/p>\n<p data-start=\"6981\" data-end=\"7068\">Atbilst\u012bbas p\u0101rbaud\u0113m parasti ir nepiecie\u0161ami prec\u012bzie svari ar iz\u0161\u0137irtsp\u0113ju 0,001 g.<\/p>\n<p data-start=\"7070\" data-end=\"7230\">Ra\u017eot\u0101ji bie\u017ei vien apvieno neizmantot\u0101s telpas anal\u012bzi ar izm\u0113ru p\u0101rbaudi un injekcijas sp\u0113ka test\u0113\u0161anu, lai pan\u0101ktu visaptvero\u0161u \u0161\u013circes darb\u012bbas p\u0101rbaudi.<\/p>\n<h2 data-section-id=\"1r8frcv\" data-start=\"8150\" data-end=\"8179\">Bie\u017e\u0101k uzdotie jaut\u0101jumi<\/h2>\n<p data-section-id=\"t3k96d\" data-start=\"8181\" data-end=\"8202\"><strong>Kas ir ISO 8537?<\/strong><br \/>\nISO 8537 ir starptautisks standarts, kas nosaka pras\u012bbas un p\u0101rbaudes metodes steriliem vienreizlietojamiem insul\u012bna \u0161\u013circes ar adatu vai bez t\u0101s.<\/p>\n<p><strong>K\u0101p\u0113c ir svar\u012bgi p\u0101rbaud\u012bt \u0161\u013circes sl\u012bd\u0113\u0161anas sp\u0113ku?<br \/>\n<\/strong>\u0160\u013circes sl\u012bd\u0113\u0161anas sp\u0113ka p\u0101rbaude nodro\u0161ina vienm\u0113r\u012bgu virzu\u013ca kust\u012bbu, stabilu injekcijas veik\u0161anu un prec\u012bzu z\u0101\u013cu ievad\u012b\u0161anu kl\u012bniskaj\u0101 lieto\u0161an\u0101.<\/p>\n<p><strong>K\u0101ds spiediens tiek izmantots \u0161\u013circes nopl\u016bdes test\u0101 saska\u0146\u0101 ar standartu ISO 8537?<br \/>\n<\/strong>Saska\u0146\u0101 ar ISO 8537 E pielikumu iek\u0161\u0113jajam spiedienam j\u0101b\u016bt <strong data-start=\"8655\" data-end=\"8666\">300 kPa<\/strong> nopl\u016bdes nov\u0113rt\u0113\u0161anas laik\u0101 tiek uztur\u0113ts 30 sekundes.<\/p>\n<p><strong>Ko nov\u0113rt\u0113 farm\u0101cijas nozares vakuuma nopl\u016bdes p\u0101rbaudes proced\u016bra?<br \/>\n<\/strong>Farmaceitisk\u0101 vakuuma nopl\u016bdes p\u0101rbaudes metode nov\u0113rt\u0113 gaisa nopl\u016bdi gar \u0161\u013circes virzu\u013ca bl\u012bv\u0113m un p\u0101rbauda virzu\u013ca un aizb\u0101\u017e\u0146a savienojuma herm\u0113tiskumu negat\u012bva spiediena apst\u0101k\u013cos.<\/p>\n<p><strong>K\u0101p\u0113c \u201etuk\u0161\u0101s telpas\u201d m\u0113r\u012b\u0161ana ir \u013coti svar\u012bga insul\u012bna \u0161\u013cir\u010du gad\u012bjum\u0101?<\/strong><br \/>\nNeizmantot\u0101s telpas m\u0113r\u012b\u0161ana pal\u012bdz samazin\u0101t z\u0101\u013cu atlikuma apjomu, uzlabojot devas precizit\u0101ti un samazinot z\u0101\u013cu iz\u0161\u0137\u0113rd\u0113\u0161anu.<\/p>\n<p><strong>K\u0101di instrumenti parasti tiek izmantoti, lai <a href=\"http:\/\/iso.org\/standard\/60510.html\" rel=\"nofollow noopener\" target=\"_blank\">ISO 8537<\/a> test\u0113\u0161ana?<\/strong><br \/>\nParastie m\u0113rinstrumenti ietver univers\u0101l\u0101s test\u0113\u0161anas iek\u0101rtas, vakuuma nopl\u016bdes test\u0113t\u0101jus, spiediena nopl\u016bdes sist\u0113mas, prec\u012bzijas svarus un automatiz\u0113tus sp\u0113ka analizatorus.<\/p>","protected":false},"excerpt":{"rendered":"<p>Standarts ISO 8537 nosaka kritiskos veiktsp\u0113jas testus steriliem vienreizlietojamiem insul\u012bna \u0161\u013circes, tostarp injic\u0113jam\u012bbu, \u0161\u013circes nopl\u016bdi, iztur\u012bbu pret vakuuma nopl\u016bdi, sl\u012bd\u0113\u0161anas sp\u0113ku un miru\u0161\u0101 tilpuma m\u0113r\u012bjumus. \u0160ie testi nov\u0113rt\u0113 herm\u0113tiskumu, virzu\u013ca darb\u012bbas sp\u0113ku, aspir\u0101cijas veiktsp\u0113ju un atliku\u0161\u0101 tilpuma precizit\u0101ti, lai nodro\u0161in\u0101tu \u0161\u013circes dro\u0161\u012bbu un devas noteik\u0161anas uzticam\u012bbu. Modernas test\u0113\u0161anas sist\u0113mas pal\u012bdz ra\u017eot\u0101jiem nodro\u0161in\u0101t konsekventu kvalit\u0101tes kontroli, \u2026<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/lv\/standards\/iso-8537\/\"> <span class=\"screen-reader-text\">ISO 8537<\/span> Las\u012bt vair\u0101k \"<\/a><\/p>","protected":false},"author":4,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7956","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/7956","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/comments?post=7956"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/7956\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/media?parent=7956"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}