{"id":7754,"date":"2025-12-26T14:04:58","date_gmt":"2025-12-26T06:04:58","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7754"},"modified":"2025-12-26T14:06:03","modified_gmt":"2025-12-26T06:06:03","slug":"astm-d6653","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/lv\/standards\/astm-d6653\/","title":{"rendered":"ASTM D6653"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"388\" data-end=\"734\">ASTM D6653<\/h1>\n<h1 style=\"text-align: center;\" data-start=\"388\" data-end=\"734\">Vakuuma nopl\u016bdes p\u0101rbaude<\/h1>\n<p data-start=\"6041\" data-end=\"6231\">Port\u0101ls <a href=\"https:\/\/www.qualitester.com\/lv\/applications\/vacuum-leak-test-for-bottles\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"398\" data-end=\"412\">ASTM D6653<\/strong><\/a> Standarts nosaka metodi, k\u0101 p\u0101rbaud\u012bt t\u0101du iepakojuma sist\u0113mu integrit\u0101ti, kas tiek pak\u013cautas liela augstuma apst\u0101k\u013ciem. \u0160is tests ir \u013coti svar\u012bgs, lai noteiktu, k\u0101 produkti un to iepakojuma sist\u0113mas darbojas spiediena starp\u012bbu apst\u0101k\u013cos, kas rodas transport\u0113\u0161anas laik\u0101, jo \u012bpa\u0161i p\u0101rs\u016bt\u012b\u0161anas lidma\u0161\u012bn\u0101s, kas lido p\u0101ri augstiem kalnu p\u0101rej\u0101m. \u0160is <strong data-start=\"740\" data-end=\"760\">vakuuma nopl\u016bdes tests<\/strong> \u0160aj\u0101 standart\u0101 nor\u0101d\u012bt\u0101 metode nov\u0113rt\u0113 iepakojuma sist\u0113mu iztur\u012bbu \u0161\u0101du spiediena izmai\u0146u apst\u0101k\u013cos.<\/p>\n<hr \/>\n<h2 data-start=\"6041\" data-end=\"6231\">ASTM D6653 standarta izpratne un t\u0101 noz\u012bme<\/h2>\n<p data-start=\"956\" data-end=\"1425\"><strong data-start=\"956\" data-end=\"970\">ASTM D6653<\/strong> ir standarta test\u0113\u0161anas metode, ar ko nov\u0113rt\u0113 liela augstuma apst\u0101k\u013cu ietekmi uz iepakojuma sist\u0113m\u0101m. \u0160is tests imit\u0113 spiediena starp\u012bbas, k\u0101das produktiem rodas gaisa transporta laik\u0101, piem\u0113ram, p\u0101rs\u0113din\u0101\u0161anas lidma\u0161\u012bn\u0101s, kuras var sasniegt 5 791 metru (19 000 p\u0113du) vai liel\u0101ku augstumu. \u0160\u012b test\u0113\u0161anas metode galvenok\u0101rt nov\u0113rt\u0113 <strong data-start=\"1297\" data-end=\"1322\">vakuuma nopl\u016b\u017eu noteik\u0161ana<\/strong> iepakojuma sist\u0113m\u0101s, kur\u0101m \u0161\u0101dos ekstrem\u0101los apst\u0101k\u013cos ir j\u0101nodro\u0161ina to integrit\u0101te.<\/p>\n<p data-start=\"1427\" data-end=\"1762\">\u0160is tests ir b\u016btisks iepakojuma ra\u017eot\u0101jiem, jo \u012bpa\u0161i tiem, kas str\u0101d\u0101 ar jut\u012bgiem produktiem, tostarp z\u0101l\u0113m, medic\u012bnas ier\u012bc\u0113m vai p\u0101rtiku, kur iepakojuma integrit\u0101te ir iz\u0161\u0137iro\u0161a. Simul\u0113jot re\u0101los apst\u0101k\u013cus, tests nodro\u0161ina, ka iepakojuma sist\u0113ma nedarbosies nepareizi vai ne\u013caus notikt pies\u0101r\u0146ojumam spiediena izmai\u0146u d\u0113\u013c.<\/p>\n<hr \/>\n<h2 data-start=\"1427\" data-end=\"1762\">ASTM D6653 test\u0113\u0161anas metodes galven\u0101s sast\u0101vda\u013cas<a href=\"https:\/\/www.qualitester.com\/lv\/applications\/vacuum-leak-test-for-bottles\/\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-7757 alignright\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test-300x300.webp\" alt=\"ASTM D6653 vakuuma nopl\u016bdes p\u0101rbaude\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test.webp 600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/h2>\n<p>Port\u0101ls <strong data-start=\"1822\" data-end=\"1842\">vakuuma nopl\u016bdes tests<\/strong> aprakst\u012bts <strong data-start=\"1856\" data-end=\"1870\">ASTM D6653<\/strong> tas ietver testa parauga, kas ir samont\u0113ta iepakojuma sist\u0113ma, pak\u013cau\u0161anu simul\u0113tai liela augstuma videi. Spiediena starp\u012bba izraisa iepakojuma sist\u0113mas izple\u0161anos, un t\u0101s integrit\u0101te tiek p\u0101rbaud\u012bta, m\u0113rot <strong data-start=\"2100\" data-end=\"2120\">vakuuma necaurlaid\u012bba<\/strong> k\u0101 ar\u012b jebk\u0101das nopl\u016bdes vai deform\u0101cijas, kas var\u0113tu rasties.<\/p>\n<hr \/>\n<h2>Testam nepiecie\u0161amais apr\u012bkojums<\/h2>\n<p data-start=\"2210\" data-end=\"2271\">Vakuuma nopl\u016bdes p\u0101rbaudei ir nepiecie\u0161ams \u0161\u0101ds apr\u012bkojums:<\/p>\n<ol data-start=\"2273\" data-end=\"2831\">\n<li data-start=\"2273\" data-end=\"2510\">\n<p data-start=\"2276\" data-end=\"2510\"><strong data-start=\"2276\" data-end=\"2294\">Vakuuma kamera<\/strong> \u2013 Kamera, kas sp\u0113j iztur\u0113t spiediena starp\u012bbu aptuveni vienas atmosf\u0113ras apm\u0113r\u0101. \u0160ai kamerai j\u0101b\u016bt ar vakuumnecaurlaid\u012bgu v\u0101ku un pietiekami lielai, lai taj\u0101 var\u0113tu ievietot test\u0113jamo paraugu, vienlaikus \u0146emot v\u0113r\u0101 t\u0101 izple\u0161anos.<\/p>\n<\/li>\n<li data-start=\"2515\" data-end=\"2718\">\n<p data-start=\"2518\" data-end=\"2718\"><strong data-start=\"2518\" data-end=\"2545\">Vakuuma m\u0113r\u012bt\u0101js un avots<\/strong> \u2013 Augstas precizit\u0101tes vakuuma m\u0113r\u012bt\u0101js ar m\u0113r\u012bjumu diapazonu no 0 l\u012bdz 100 kPa (no 0 l\u012bdz 30 in. Hg), precizit\u0101ti \u00b12%, k\u0101 ar\u012b iepl\u016bdes cauruli no vakuuma avota un izpl\u016bdes cauruli uz atmosf\u0113ru.<\/p>\n<\/li>\n<li data-start=\"2723\" data-end=\"2831\">\n<p data-start=\"2726\" data-end=\"2831\"><strong data-start=\"2726\" data-end=\"2745\">Vakuuma vad\u012bbas ier\u012bces<\/strong> \u2013 Manu\u0101lie v\u0101rsti, kas paredz\u0113ti vakuuma atbr\u012bvo\u0161anas un pievad\u012b\u0161anas regul\u0113\u0161anai ar noteiktu \u0101trumu.<\/p>\n<\/li>\n<\/ol>\n<hr \/>\n<h2>Testa veik\u0161anas k\u0101rt\u012bba<\/h2>\n<ul>\n<li data-start=\"2876\" data-end=\"3095\">\n<p data-start=\"2879\" data-end=\"3095\"><strong data-start=\"2879\" data-end=\"2904\">Parauga sagatavo\u0161ana:<\/strong><br data-start=\"2904\" data-end=\"2907\" \/>Test\u0113jam\u0101 iepakojuma sist\u0113ma tiek r\u016bp\u012bgi sagatavota, nodro\u0161inot, ka t\u0101 atspogu\u013co tipisku ra\u017eo\u0161anas partiju. Test\u0113jamais paraugs tiek kondicion\u0113ts temperat\u016br\u0101 5,6 \u00b1 2 \u00b0C [42 \u00b1 3,6 \u00b0F] vismaz 24 stundas.<\/p>\n<\/li>\n<li data-start=\"3097\" data-end=\"3291\">\n<p data-start=\"3100\" data-end=\"3291\"><strong data-start=\"3100\" data-end=\"3125\">Vakuuma kameras uzst\u0101d\u012b\u0161ana:<\/strong><br data-start=\"3125\" data-end=\"3128\" \/>Ievietojiet paraugu vakuuma kamer\u0101, p\u0101rliecinoties, ka kamera ir herm\u0113tiski nosl\u0113gta. Kamera iepl\u016bdes v\u0101rsts ir aizv\u0113rts, bet izpl\u016bdes v\u0101rsts ir atv\u0113rts, lai rad\u012btu vakuumu.<\/p>\n<\/li>\n<li data-start=\"3293\" data-end=\"3543\">\n<p data-start=\"3296\" data-end=\"3543\"><strong data-start=\"3296\" data-end=\"3321\">Spiediena pielieto\u0161ana:<\/strong><br data-start=\"3321\" data-end=\"3324\" \/>Vakuums tiek rad\u012bts ar \u0101trumu aptuveni 305 metri (1 000 p\u0113das) 30\u201360 sekund\u0113s. Standarta test\u0101 spiediens kameras iek\u0161ien\u0113 tiek pazemin\u0101ts l\u012bdz l\u012bmenim, kas atbilst augstumam 16 000 p\u0113das \u00b15%.<\/p>\n<\/li>\n<li data-start=\"3545\" data-end=\"3677\">\n<p data-start=\"3548\" data-end=\"3677\"><strong data-start=\"3548\" data-end=\"3566\">Testa ilgums:<\/strong><br data-start=\"3566\" data-end=\"3569\" \/>Paraugs tiek pak\u013cauts \u0161im vakuumam 60 min\u016btes, t\u0101d\u0113j\u0101di imit\u0113jot transport\u0113\u0161anas liela augstum\u0101 rad\u012bt\u0101s sekas.<\/p>\n<\/li>\n<li data-start=\"3679\" data-end=\"3835\">\n<p data-start=\"3682\" data-end=\"3835\"><strong data-start=\"3682\" data-end=\"3704\">Vakuuma atbr\u012bvo\u0161ana:<\/strong><br data-start=\"3704\" data-end=\"3707\" \/>P\u0113c testa beig\u0101m vakuums tiek l\u0113n\u0101m atbr\u012bvots, un paraugs tiek p\u0101rbaud\u012bts, lai konstat\u0113tu jebk\u0101das boj\u0101jumu vai deform\u0101ciju paz\u012bmes.<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h2>Rezult\u0101tu nov\u0113rt\u0113\u0161ana<\/h2>\n<p>P\u0113c p\u0101rbaudes iepako\u0161anas sist\u0113ma tiek r\u016bp\u012bgi p\u0101rbaud\u012bta, lai konstat\u0113tu jebk\u0101das paz\u012bmes, kas liecina par <strong data-start=\"3944\" data-end=\"3955\">nopl\u016bde<\/strong> vai <strong data-start=\"3959\" data-end=\"3974\">deform\u0101cija<\/strong>. Ja iepakojums saglab\u0101 savu integrit\u0101ti bez b\u016btiskas deform\u0101cijas vai nopl\u016bdes, tas iztur p\u0101rbaudi, liecinot, ka tas sp\u0113j iztur\u0113t transport\u0113\u0161anas laik\u0101 valdo\u0161os apst\u0101k\u013cus liel\u0101 augstum\u0101. Ja paraugs uzr\u0101da boj\u0101jumu paz\u012bmes, ra\u017eot\u0101ji var nov\u0113rt\u0113t, vai spiediena starp\u012bba ir ietekm\u0113jusi \u0161uves vai iepakojuma integrit\u0101ti.<\/p>\n<hr \/>\n<h2>K\u0101p\u0113c vakuuma nopl\u016bdes p\u0101rbaude ir svar\u012bga iepakojumam?<\/h2>\n<p data-start=\"5053\" data-end=\"5309\">Iepakojumam ir iz\u0161\u0137iro\u0161a noz\u012bme produktu aizsardz\u012bb\u0101, jo \u012bpa\u0161i t\u0101d\u0101s nozar\u0113s k\u0101 farm\u0101cija un p\u0101rtikas r\u016bpniec\u012bba. <strong data-start=\"5164\" data-end=\"5187\">Vakuuma nopl\u016bdes p\u0101rbaude<\/strong> nodro\u0161ina, ka iepakojums sp\u0113j iztur\u0113t spiediena sv\u0101rst\u012bbas, t\u0101d\u0113j\u0101di garant\u0113jot, ka produkti transport\u0113\u0161anas laik\u0101 paliek dro\u0161i un nepies\u0101r\u0146oti.<\/p>\n<p data-start=\"5311\" data-end=\"5582\">Ra\u017eot\u0101jiem, <strong data-start=\"5330\" data-end=\"5344\">ASTM D6653<\/strong> sniedz v\u0113rt\u012bgus datus par iepakojuma veiktsp\u0113ju ekstrem\u0101los apst\u0101k\u013cos. Izmantojot \u0161o testu, uz\u0146\u0113mumi var p\u0101rliecin\u0101ties, ka to iepakojuma risin\u0101jumi atbilst nozares standartiem attiec\u012bb\u0101 uz p\u0101rvad\u0101jumiem liel\u0101 augstum\u0101, un nov\u0113rst iesp\u0113jamus produktu boj\u0101jumus.<\/p>\n<hr \/>\n<h2 data-start=\"5311\" data-end=\"5582\">Secin\u0101jums<\/h2>\n<p>Port\u0101ls <strong data-start=\"5608\" data-end=\"5628\">vakuuma nopl\u016bdes tests<\/strong> izkl\u0101st\u012bts <strong data-start=\"5641\" data-end=\"5655\">ASTM D6653<\/strong> ir \u013coti svar\u012bga proced\u016bra ra\u017eot\u0101jiem un kvalit\u0101tes kontroles speci\u0101listiem, lai nov\u0113rt\u0113tu iepakojuma sist\u0113mu integrit\u0101ti. Simul\u0113jot apst\u0101k\u013cus liel\u0101 augstum\u0101, \u0161is tests pal\u012bdz nodro\u0161in\u0101t, ka produkti transport\u0113\u0161anas laik\u0101 paliek dro\u0161i un neskarti. Izmantojot <strong data-start=\"5906\" data-end=\"5940\">\u2019Cell Instruments\u201c nopl\u016bdes testeri<\/strong>, ra\u017eot\u0101ji var prec\u012bzi veikt \u0161os testus, nodro\u0161inot, ka to iepakojuma sist\u0113mas atbilst m\u016bsdienu transporta un izplat\u012b\u0161anas t\u012bklu stingraj\u0101m pras\u012bb\u0101m.<\/p>\n<hr \/>\n<h2>BIE\u017d\u0100K UZDOTIE JAUT\u0100JUMI<\/h2>\n<p>&nbsp;<\/p>\n<p data-start=\"92\" data-end=\"165\"><strong data-start=\"92\" data-end=\"165\">1. jaut\u0101jums: Kas ir ASTM D6653 un k\u0101p\u0113c tas ir svar\u012bgs iepakojuma sist\u0113m\u0101m?<\/strong><\/p>\n<p data-start=\"167\" data-end=\"730\"><strong data-start=\"167\" data-end=\"174\">A1:<\/strong><br data-start=\"174\" data-end=\"177\" \/>ASTM D6653 ir standarta test\u0113\u0161anas metode, kas nov\u0113rt\u0113 liela augstuma apst\u0101k\u013cu ietekmi uz iepakojuma sist\u0113m\u0101m, jo \u012bpa\u0161i attiec\u012bb\u0101 uz produktiem, kurus ar lidma\u0161\u012bn\u0101m p\u0101rvad\u0101 p\u0101ri augstiem kalnu p\u0101rej\u0101m. \u0160is tests simul\u0113 spiediena starp\u012bbas, kas rodas, kad iepakojuma sist\u0113mas tiek pak\u013cautas liela augstuma apst\u0101k\u013ciem, nodro\u0161inot, ka iepakojums saglab\u0101 savu integrit\u0101ti un nov\u0113r\u0161 boj\u0101jumus p\u0101rvad\u0101\u0161anas laik\u0101. Tas ir \u013coti svar\u012bgi iepakojuma sist\u0113m\u0101m t\u0101d\u0101s nozar\u0113s k\u0101 farm\u0101cija, p\u0101rtikas r\u016bpniec\u012bba un elektronika, kur iepakojuma boj\u0101jumi var apdraud\u0113t produkta dro\u0161\u012bbu vai kvalit\u0101ti.<\/p>\n<hr data-start=\"732\" data-end=\"735\" \/>\n<p data-start=\"737\" data-end=\"794\"><strong data-start=\"737\" data-end=\"794\">2. jaut\u0101jums: K\u0101 darbojas vakuuma nopl\u016bdes p\u0101rbaude saska\u0146\u0101 ar standartu ASTM D6653?<\/strong><\/p>\n<p data-start=\"796\" data-end=\"1338\"><strong data-start=\"796\" data-end=\"803\">A2:<\/strong><br data-start=\"803\" data-end=\"806\" \/>Vakuuma nopl\u016bdes tests saska\u0146\u0101 ar standartu ASTM D6653 tiek veikts, pak\u013caujot iepakoto produktu simul\u0113tai liela augstuma videi vakuuma kamer\u0101. Test\u0101 iepakojuma sist\u0113mai tiek rad\u012bts vakuums, lai simul\u0113tu spiediena starp\u012bbu, kas rodas gaisa transporta laik\u0101 lielos augstumos. P\u0113c tam iepakojumu p\u0101rbauda, lai konstat\u0113tu jebk\u0101das deform\u0101cijas, nopl\u016bdes vai boj\u0101jumu paz\u012bmes p\u0113c pak\u013cau\u0161anas vakuumam. Tas pal\u012bdz noteikt, vai iepakojums sp\u0113j iztur\u0113t spiediena izmai\u0146as, neietekm\u0113jot t\u0101 sp\u0113ju aizsarg\u0101t produktu.<\/p>\n<hr data-start=\"1340\" data-end=\"1343\" \/>\n<p data-start=\"1345\" data-end=\"1433\"><strong data-start=\"1345\" data-end=\"1433\">3. jaut\u0101jums: K\u0101das ir galven\u0101s iek\u0101rtas, kas nepiecie\u0161amas ASTM D6653 vakuuma nopl\u016bdes p\u0101rbau\u017eu veik\u0161anai?<\/strong><\/p>\n<p data-start=\"1435\" data-end=\"1523\"><strong data-start=\"1435\" data-end=\"1442\">A3:<\/strong><br data-start=\"1442\" data-end=\"1445\" \/>Lai veiktu ASTM D6653 vakuuma nopl\u016bdes p\u0101rbaudes, ir nepiecie\u0161ams \u0161\u0101ds apr\u012bkojums:<\/p>\n<ol>\n<li data-start=\"1527\" data-end=\"1658\"><strong data-start=\"1527\" data-end=\"1546\">Vakuuma kamera:<\/strong> Kamera, kas sp\u0113j iztur\u0113t aptuveni vienas atmosf\u0113ras spiediena starp\u012bbu un ir apr\u012bkota ar vakuumiztur\u012bgu v\u0101ku.<\/li>\n<li data-start=\"1662\" data-end=\"1783\"><strong data-start=\"1662\" data-end=\"1679\">Vakuuma m\u0113r\u012bt\u0101js:<\/strong> Laboratorijas kvalit\u0101tes vakuuma m\u0113r\u012bt\u0101js ar m\u0113r\u012bjumu diapazonu no 0 l\u012bdz 100 kPa (no 0 l\u012bdz 30 in. Hg) un precizit\u0101ti \u00b12%.<\/li>\n<li data-start=\"1787\" data-end=\"1924\"><strong data-start=\"1787\" data-end=\"1817\">Vakuuma avots un vad\u012bba:<\/strong> Ieejas un izejas caurules, kas apr\u012bkotas ar manu\u0101li darbin\u0101miem v\u0101rstiem, lai regul\u0113tu vakuuma rad\u012b\u0161anu un atbr\u012bvo\u0161anu.<\/li>\n<li data-start=\"1925\" data-end=\"2035\">\n<p data-start=\"1928\" data-end=\"2035\"><strong data-start=\"1928\" data-end=\"1946\">Parauga tur\u0113t\u0101js:<\/strong> Tur\u0113t\u0101js, kas ir pietiekami liels, lai taj\u0101 var\u0113tu ievietot testa paraugu un nodro\u0161in\u0101tu t\u0101 izple\u0161anos testa laik\u0101.<\/p>\n<\/li>\n<\/ol>\n<hr data-start=\"2037\" data-end=\"2040\" \/>\n<p data-start=\"2042\" data-end=\"2114\"><strong data-start=\"2042\" data-end=\"2114\">4. jaut\u0101jums: Cik ilgi saska\u0146\u0101 ar standartu ASTM D6653 j\u0101ilgst vakuuma nopl\u016bdes p\u0101rbaudei?<\/strong><\/p>\n<p data-start=\"2116\" data-end=\"2463\"><strong data-start=\"2116\" data-end=\"2123\">A4:<\/strong><br data-start=\"2123\" data-end=\"2126\" \/>Saska\u0146\u0101 ar standartu ASTM D6653 vakuuma nopl\u016bdes p\u0101rbaudei j\u0101ilgst 60 min\u016btes, kuras laik\u0101 p\u0101rbaud\u0101mais paraugs tiek pak\u013cauts vakuuma spiedienam, kas atbilst lielam augstumam (piem\u0113ram, 16 000 p\u0113du \u00b1 5%). \u0160is laiks \u013cauj pietiekami prec\u012bzi simul\u0113t apst\u0101k\u013cus, k\u0101diem iepakojums var tikt pak\u013cauts, to transport\u0113jot caur liel\u0101 augstum\u0101 eso\u0161iem re\u0123ioniem.<\/p>\n<hr data-start=\"2465\" data-end=\"2468\" \/>\n<p data-start=\"2470\" data-end=\"2556\"><strong data-start=\"2470\" data-end=\"2556\">5. jaut\u0101jums: K\u0101di ir galvenie rezult\u0101ti, uz kuriem j\u0101piev\u0113r\u0161 uzman\u012bba p\u0113c vakuuma nopl\u016bdes p\u0101rbaudes veik\u0161anas?<\/strong><\/p>\n<p data-start=\"2558\" data-end=\"2647\"><strong data-start=\"2558\" data-end=\"2565\">A5:<\/strong><br data-start=\"2565\" data-end=\"2568\" \/>P\u0113c vakuuma nopl\u016bdes p\u0101rbaudes veik\u0161anas ir j\u0101izv\u0113rt\u0113 \u0161\u0101di b\u016btiskie rezult\u0101ti:<\/p>\n<ol>\n<li data-start=\"2651\" data-end=\"2802\"><strong data-start=\"2651\" data-end=\"2667\">Deform\u0101cija:<\/strong> P\u0101rbaudiet, vai iepakojums nav deform\u0113jies spiediena sv\u0101rst\u012bbu d\u0113\u013c. Iepakojums, kas iev\u0113rojami izple\u0161as vai maina formu, var b\u016bt boj\u0101ts.<\/li>\n<li data-start=\"2806\" data-end=\"2949\"><strong data-start=\"2806\" data-end=\"2818\">Nopl\u016bde:<\/strong> P\u0101rbaudiet iepakojumu, vai uz t\u0101 nav nopl\u016bdes paz\u012bmes, kas liecin\u0101tu par to, ka nav izdevies saglab\u0101t herm\u0113tisk\u0101 iepakojuma integrit\u0101ti.<\/li>\n<li data-start=\"2953\" data-end=\"3097\"><strong data-start=\"2953\" data-end=\"2978\">Konstrukcijas integrit\u0101te:<\/strong> P\u0101rliecinieties, ka visas iepakojuma \u0161uves, aizdares un deta\u013cas ir neskartas un bez redzam\u0101m plais\u0101m vai boj\u0101jumiem.<\/li>\n<\/ol>\n<p data-start=\"3099\" data-end=\"3224\">Ja nav nov\u0113roti noz\u012bm\u012bgi boj\u0101jumi vai nopl\u016bdes, iepakojuma sist\u0113mu var uzskat\u012bt par piem\u0113rotu transport\u0113\u0161anai liel\u0101 augstum\u0101.<\/p>","protected":false},"excerpt":{"rendered":"<p>ASTM D6653 Vacuum Leak Test The ASTM D6653 standard outlines a method for testing the integrity of packaging systems exposed to high-altitude conditions. This test is crucial for determining how products and their packaging systems perform under pressure differentials encountered during transport, especially in feeder aircraft traveling over high mountain passes. The vacuum leak test &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/lv\/standards\/astm-d6653\/\"> <span class=\"screen-reader-text\">ASTM D6653<\/span> Las\u012bt vair\u0101k \"<\/a><\/p>","protected":false},"author":4,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7754","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/7754","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/comments?post=7754"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/7754\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/media?parent=7754"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}