{"id":7336,"date":"2025-07-31T15:17:43","date_gmt":"2025-07-31T07:17:43","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7336"},"modified":"2025-07-31T15:23:02","modified_gmt":"2025-07-31T07:23:02","slug":"nf-t54-116","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/lv\/standards\/nf-t54-116\/","title":{"rendered":"NF T54-116"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"368\" data-end=\"454\">NF T54-116<\/h1>\n<h2 style=\"text-align: center;\" data-start=\"368\" data-end=\"454\">Film Pendulum Impact Test<\/h2>\n<h2 data-start=\"456\" data-end=\"512\"><\/h2>\n<p data-start=\"514\" data-end=\"987\">Port\u0101ls <strong data-start=\"518\" data-end=\"532\">NF T54-116<\/strong> standard defines a reliable method for measuring the <strong data-start=\"586\" data-end=\"623\">plastmasas pl\u0113ves triecieniztur\u012bba<\/strong> izmantojot <strong data-start=\"632\" data-end=\"655\">sv\u0101rsta trieciena tests<\/strong>. It is especially valuable for evaluating the performance of flexible films used in <strong data-start=\"740\" data-end=\"783\">packaging, pharmaceuticals, electronics<\/strong>, un <strong data-start=\"789\" data-end=\"817\">medical device materials<\/strong>. By using<span style=\"font-size: 16px;\"> this method, manufacturers can determine how well a film resists sudden impacts that could lead to ruptur<\/span><span style=\"font-size: 16px;\">e or puncture during ha<\/span><span style=\"font-size: 16px;\">ndling, transporta<\/span><img decoding=\"async\" class=\"wp-image-7338 alignright\" style=\"font-weight: inherit;\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/pendulum-impact-tester-2_11zon-300x300.webp\" alt=\"NF T54-116 with film pendulum impact tester \" width=\"169\" height=\"169\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/pendulum-impact-tester-2_11zon-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/pendulum-impact-tester-2_11zon-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/pendulum-impact-tester-2_11zon-768x768.webp 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/pendulum-impact-tester-2_11zon-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/pendulum-impact-tester-2_11zon-600x600.webp 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/pendulum-impact-tester-2_11zon-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/pendulum-impact-tester-2_11zon.webp 1024w\" sizes=\"(max-width: 169px) 100vw, 169px\" \/><span style=\"font-size: 16px;\">tion, or use.<\/span><\/p>\n<p data-start=\"989\" data-end=\"1295\">vietn\u0113 <strong data-start=\"992\" data-end=\"1012\">\u0160\u016bnu instrumenti<\/strong>, we specialize in offering advanced <strong data-start=\"1049\" data-end=\"1081\">film pendulum impact testers<\/strong>, such as the <a href=\"https:\/\/www.qualitester.com\/lv\/film-pendulum-impact-tester\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"1095\" data-end=\"1105\">PIT-01<\/strong><\/a>, that meet NF T54-116 and global standards like <strong data-start=\"1154\" data-end=\"1168\">ASTM D3420<\/strong>. In this article, you\u2019ll learn what NF T54-116 entails, how the test is performed, and why it\u2019s essential for quality control.<\/p>\n<hr data-start=\"1297\" data-end=\"1300\" \/>\n<h2 data-start=\"1302\" data-end=\"1354\">Film Pendulum Impact Tester and Related Standards<\/h2>\n<p data-start=\"1356\" data-end=\"1653\">Port\u0101ls <strong data-start=\"1360\" data-end=\"1391\">pl\u0113ves sv\u0101rsta trieciena testeris<\/strong> is designed to simulate mechanical shock on thin plastic sheets by measuring the energy required to puncture them. The <strong data-start=\"1511\" data-end=\"1557\">plastmasas pl\u0113ves triecieniztur\u012bba pret sv\u0101rsta triecienu<\/strong> is a critical property that reflects the material\u2019s ability to withstand real-world conditions.<\/p>\n<p data-start=\"1655\" data-end=\"1730\">NF T54-116 is frequently used alongside international standards, including:<\/p>\n<ul data-start=\"1732\" data-end=\"2021\">\n<li data-start=\"1732\" data-end=\"1820\">\n<p data-start=\"1734\" data-end=\"1820\"><strong data-start=\"1734\" data-end=\"1748\">ASTM D3420<\/strong> \u2013 Standard Test Method for Pendulum Impact Resistance of Plastic Film<\/p>\n<\/li>\n<li data-start=\"1821\" data-end=\"1941\">\n<p data-start=\"1823\" data-end=\"1941\"><strong data-start=\"1823\" data-end=\"1846\">Spencer Impact Test<\/strong> \u2013 Used in North American labs and often performed using <strong data-start=\"1903\" data-end=\"1939\">spencer impact testing equipment<\/strong><\/p>\n<\/li>\n<li data-start=\"1942\" data-end=\"2021\">\n<p data-start=\"1944\" data-end=\"2021\"><strong data-start=\"1944\" data-end=\"1957\">GB\/T 8809<\/strong> \u2013 China\u2019s national standard for <strong data-start=\"1990\" data-end=\"2021\">pl\u0113ves triecieniztur\u012bbas tests<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2023\" data-end=\"2191\">These standards, although varied in procedures, all aim to assess <strong data-start=\"2089\" data-end=\"2124\">film pendulum impact resistance<\/strong> to support product development, compliance, and quality assurance.<\/p>\n<hr data-start=\"2193\" data-end=\"2196\" \/>\n<h2 data-start=\"2198\" data-end=\"2245\">How the NF T54-116 Pendulum Shock Test Works<\/h2>\n<p data-start=\"2247\" data-end=\"2424\">NF standard specifies the use of a <strong data-start=\"2281\" data-end=\"2312\">pendulum impact test system<\/strong> that incorporates a hemispherical striker and a rigid specimen clamping mechanism. Here\u2019s how the method works:<\/p>\n<p data-start=\"2426\" data-end=\"2445\"><strong data-start=\"2426\" data-end=\"2445\">Test Principle:<\/strong><\/p>\n<ul data-start=\"2447\" data-end=\"2814\">\n<li data-start=\"2447\" data-end=\"2546\">\n<p data-start=\"2449\" data-end=\"2546\">A <strong data-start=\"2451\" data-end=\"2466\">film sample<\/strong> (100\u00d7100 mm or \u00d8100 mm) is clamped securely using pneumatic or manual fixtures.<\/p>\n<\/li>\n<li data-start=\"2547\" data-end=\"2664\">\n<p data-start=\"2549\" data-end=\"2664\">A <strong data-start=\"2551\" data-end=\"2563\">pendulum<\/strong>, fitted with a <strong data-start=\"2579\" data-end=\"2608\">hemispherical impact head<\/strong> (usually \u00d838.1 mm), swings from a predetermined height.<\/p>\n<\/li>\n<li data-start=\"2665\" data-end=\"2814\">\n<p data-start=\"2667\" data-end=\"2814\">The pendulum hits the center of the specimen, and the <strong data-start=\"2721\" data-end=\"2740\">absorb\u0113t\u0101 ener\u0123ija<\/strong> is calculated from the difference in swing angle before and after impact.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2816\" data-end=\"2839\"><strong data-start=\"2816\" data-end=\"2839\">Energy Measurement:<\/strong><\/p>\n<p data-start=\"2841\" data-end=\"3071\">The result, in joules, is normalized against the film\u2019s thickness to determine its <strong data-start=\"2924\" data-end=\"2962\">specific resistance to perforation<\/strong>. The goal is to ensure that the <strong data-start=\"2995\" data-end=\"3030\">pendulum impact resistance test<\/strong> reflects realistic material performance.<\/p>\n<p data-start=\"3073\" data-end=\"3095\"><strong data-start=\"3073\" data-end=\"3095\">Visual Inspection:<\/strong><\/p>\n<p data-start=\"3097\" data-end=\"3235\">In addition to numeric values, the <strong data-start=\"3132\" data-end=\"3165\">appearance of the perforation<\/strong> is also noted\u2014whether the film tears cleanly, stretches, or shatters.<\/p>\n<hr data-start=\"3237\" data-end=\"3240\" \/>\n<h2 data-start=\"3242\" data-end=\"3282\">Why Use Film Pendulum Impact Testing?<\/h2>\n<p data-start=\"3284\" data-end=\"3428\"><strong data-start=\"3284\" data-end=\"3318\">Film impact resistance testing<\/strong> is essential for materials used in high-performance applications. It is widely adopted in industries such as:<\/p>\n<ul data-start=\"3430\" data-end=\"3773\">\n<li data-start=\"3430\" data-end=\"3519\">\n<p data-start=\"3432\" data-end=\"3519\"><strong data-start=\"3432\" data-end=\"3454\">Elast\u012bgais iepakojums<\/strong>: Ensures pouch, sachet, and blister durability during transport.<\/p>\n<\/li>\n<li data-start=\"3520\" data-end=\"3605\">\n<p data-start=\"3522\" data-end=\"3605\"><strong data-start=\"3522\" data-end=\"3541\">Medic\u012bnisk\u0101s ier\u012bces<\/strong>: Validates the structural integrity of sterile barrier systems.<\/p>\n<\/li>\n<li data-start=\"3606\" data-end=\"3687\">\n<p data-start=\"3608\" data-end=\"3687\"><strong data-start=\"3608\" data-end=\"3627\">P\u0101rtika un dz\u0113rieni<\/strong>: Tests multi-layer films and laminates for shipping stress.<\/p>\n<\/li>\n<li data-start=\"3688\" data-end=\"3773\">\n<p data-start=\"3690\" data-end=\"3773\"><strong data-start=\"3690\" data-end=\"3720\">Automotive and Electronics<\/strong>: Evaluates composite membranes and protective films.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3775\" data-end=\"3962\">Manufacturers must ensure that materials will not fail under mechanical stress. This makes <strong data-start=\"3866\" data-end=\"3902\">pendulum impact resistance tests<\/strong> a standard quality control procedure in R&amp;D and production.<\/p>\n<hr data-start=\"3964\" data-end=\"3967\" \/>\n<h2 data-start=\"3969\" data-end=\"4041\">PIT-01 Pendulum Impact Tester: Trusted Solution from Cell Instruments<\/h2>\n<p data-start=\"4043\" data-end=\"4255\">For accurate, repeatable <strong data-start=\"4068\" data-end=\"4100\">pl\u0113ves sv\u0101rsta trieciena test\u0113\u0161ana<\/strong>, <strong data-start=\"4102\" data-end=\"4130\">Cell Instruments\u2019 PIT-01<\/strong> is a preferred choice. The PIT-01 is engineered in strict accordance with <strong data-start=\"4205\" data-end=\"4219\">NF T54-116<\/strong>, <strong data-start=\"4221\" data-end=\"4235\">ASTM D3420<\/strong>, un <strong data-start=\"4241\" data-end=\"4254\">GB\/T 8809<\/strong>.<\/p>\n<h3 data-start=\"4257\" data-end=\"4274\">Galven\u0101s funkcijas:<\/h3>\n<ul data-start=\"4276\" data-end=\"4613\">\n<li data-start=\"4276\" data-end=\"4339\">\n<p data-start=\"4278\" data-end=\"4339\"><strong data-start=\"4278\" data-end=\"4306\">Multiple impact energies<\/strong>: 1 J, 2 J, 3 J, and optional 5 J<\/p>\n<\/li>\n<li data-start=\"4340\" data-end=\"4393\">\n<p data-start=\"4342\" data-end=\"4393\"><strong data-start=\"4342\" data-end=\"4365\">Hemispherical heads<\/strong>: \u00d825.4 mm, \u00d819 mm, \u00d812.7 mm<\/p>\n<\/li>\n<li data-start=\"4394\" data-end=\"4440\">\n<p data-start=\"4396\" data-end=\"4440\"><strong data-start=\"4396\" data-end=\"4431\">High-accuracy energy resolution<\/strong>: 0.001 J<\/p>\n<\/li>\n<li data-start=\"4441\" data-end=\"4498\">\n<p data-start=\"4443\" data-end=\"4498\"><strong data-start=\"4443\" data-end=\"4468\">Auto-release pendulum<\/strong> with real-time energy reading<\/p>\n<\/li>\n<li data-start=\"4499\" data-end=\"4554\">\n<p data-start=\"4501\" data-end=\"4554\"><strong data-start=\"4501\" data-end=\"4523\">Pneimatisk\u0101 iesp\u012bl\u0113\u0161ana<\/strong> for consistent test conditions<\/p>\n<\/li>\n<li data-start=\"4555\" data-end=\"4613\">\n<p data-start=\"4557\" data-end=\"4613\"><strong data-start=\"4557\" data-end=\"4576\">Touchscreen HMI<\/strong> and integrated statistical reporting<\/p>\n<\/li>\n<\/ul>\n<p style=\"text-align: left;\" data-start=\"4615\" data-end=\"4879\"><strong data-start=\"4615\" data-end=\"4625\">PIT-01<\/strong> helps R&amp;D teams and quality assurance professionals assess the <strong data-start=\"4689\" data-end=\"4735\">plastmasas pl\u0113ves triecieniztur\u012bba pret sv\u0101rsta triecienu<\/strong> with confidence. It also simplifies compliance with <strong data-start=\"4788\" data-end=\"4837\">astm standards for impact testing of plastics<\/strong> un <strong data-start=\"4842\" data-end=\"4865\">Spencera trieciena tests<\/strong> requirements.<\/p>\n<hr data-start=\"4881\" data-end=\"4884\" \/>\n<h2 data-start=\"4886\" data-end=\"4953\">How to Perform a Film Impact Resistance Test Based on NF T54-116<\/h2>\n<p data-start=\"4955\" data-end=\"5089\"><strong data-start=\"4955\" data-end=\"4980\">1. Parauga sagatavo\u0161ana<\/strong><br data-start=\"4980\" data-end=\"4983\" \/>Cut 10 test specimens (100\u00d7100 mm or \u00d8100 mm). Condition them at 23\u202f\u00b1\u202f2\u00b0C and 50% RH for at least 2 hours.<\/p>\n<p data-start=\"5091\" data-end=\"5255\"><strong data-start=\"5091\" data-end=\"5111\">2. Machine Setup<\/strong><br data-start=\"5111\" data-end=\"5114\" \/>Calibrate the <strong data-start=\"5128\" data-end=\"5159\">pl\u0113ves sv\u0101rsta trieciena testeris<\/strong>, zero the pointer without a specimen, and select the appropriate impact head and c<strong style=\"font-size: 16px; font-style: normal;\" data-start=\"4443\" data-end=\"4468\"><strong style=\"font-size: 16px; font-style: normal; text-align: right;\" data-start=\"4615\" data-end=\"4625\"><span style=\"font-size: 16px;\">ounterweight.<\/span><\/strong><\/strong><\/p>\n<p data-start=\"5257\" data-end=\"5383\"><strong data-start=\"5257\" data-end=\"5272\">3. Clamping<\/strong><br data-start=\"5272\" data-end=\"5275\" \/>Use pneumatic clamping to secure the specimen in a horizontal plane. Ensure pressure is stable and centered.<\/p>\n<p data-start=\"5385\" data-end=\"5553\"><strong data-start=\"5385\" data-end=\"5406\">4. Impact Testing<\/strong><br data-start=\"5406\" data-end=\"5409\" \/>Release the pendulum. It strikes the specimen at a fixed energy level, and the <strong data-start=\"5488\" data-end=\"5507\">absorb\u0113t\u0101 ener\u0123ija<\/strong> during perforation is automatically recorded.<\/p>\n<p data-start=\"5555\" data-end=\"5721\"><strong data-start=\"5555\" data-end=\"5576\">5. Data Recording<\/strong><br data-start=\"5576\" data-end=\"5579\" \/>Log the absorbed energy, calculate specific resistance (J\/\u03bcm), and observe the perforation type: brittle or ductile. Repeat for all specimens.<\/p>\n<p style=\"text-align: left;\" data-start=\"5723\" data-end=\"5779\"><strong data-start=\"5723\" data-end=\"5744\">6. Report Results<\/strong><br data-start=\"5744\" data-end=\"5747\" \/>Your test report should include:<\/p>\n<ul data-start=\"5780\" data-end=\"5940\">\n<li data-start=\"5780\" data-end=\"5830\">\n<p data-start=\"5782\" data-end=\"5830\">Mean and standard deviation of absorbed energy<\/p>\n<\/li>\n<li data-start=\"5831\" data-end=\"5850\">\n<p style=\"text-align: left;\" data-start=\"5833\" data-end=\"5850\">Type of failure<\/p>\n<\/li>\n<li data-start=\"5851\" data-end=\"5879\">\n<p data-start=\"5853\" data-end=\"5879\">Vides apst\u0101k\u013ci<\/p>\n<\/li>\n<li data-start=\"5880\" data-end=\"5907\">\n<p data-start=\"5882\" data-end=\"5907\">Equipment configuration<\/p>\n<\/li>\n<li data-start=\"5908\" data-end=\"5940\">\n<p data-start=\"5910\" data-end=\"5940\">Full specimen identification<\/p>\n<\/li>\n<\/ul>\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Sample preparation for film pendulum impact tester\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/DuAGnqNIaOE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<hr data-start=\"6045\" data-end=\"6048\" \/>\n<h2 data-start=\"6050\" data-end=\"6107\">Conclusion: Reliable Testing for Safer, Stronger Films<\/h2>\n<p data-start=\"6109\" data-end=\"6396\">Port\u0101ls <strong data-start=\"6113\" data-end=\"6153\">NF T54-116 film pendulum impact test<\/strong> is essential for validating the durability and toughness of plastic sheets used in sensitive and demanding environments. It not only ensures regulatory compliance but also helps prevent packaging failures that could compromise product safety.<\/p>\n<p data-start=\"6398\" data-end=\"6613\">With advanced solutions like the <strong data-start=\"6431\" data-end=\"6464\"><a href=\"https:\/\/www.celtec.cn\/productinfo\/1239673.html\" target=\"_blank\" rel=\"noopener nofollow\">PIT-01 Pendulum Impact Teste<\/a>r<\/strong> no <strong data-start=\"6470\" data-end=\"6490\">\u0160\u016bnu instrumenti<\/strong>, laboratories and manufacturers can carry out <strong data-start=\"6537\" data-end=\"6573\">pendulum impact resistance tests<\/strong> with unmatched accuracy and efficiency.<\/p>\n<p data-start=\"6615\" data-end=\"6783\" data-is-last-node=\"\" data-is-only-node=\"\"><strong data-start=\"6615\" data-end=\"6783\" data-is-last-node=\"\">Get in touch with Cell Instruments to explore how the PIT-01 can enhance your material testing capabilities and ensure your films meet global performance standa<\/strong><strong style=\"font-size: 16px; font-style: normal;\" data-start=\"4443\" data-end=\"4468\"><strong style=\"font-size: 16px; font-style: normal; text-align: right;\" data-start=\"4615\" data-end=\"4625\"><strong style=\"font-size: 16px;\" data-start=\"6615\" data-end=\"6783\" data-is-last-node=\"\">rds.<\/strong><\/strong><\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>NF T54-116 Pl\u0113ves sv\u0101rsta triecieniztur\u012bbas tests Standarts NF T54-116 nosaka uzticamu metodi plastmasas pl\u0113ves triecieniztur\u012bbas m\u0113r\u012b\u0161anai, izmantojot sv\u0101rsta trieciena testu. T\u0101 ir \u012bpa\u0161i v\u0113rt\u012bga, lai nov\u0113rt\u0113tu elast\u012bgo pl\u0113vju, ko izmanto iepakojuma, farm\u0101cijas, elektronikas un medic\u012bnas ier\u012b\u010du materi\u0101lu ra\u017eo\u0161an\u0101, veiktsp\u0113ju. Izmantojot \u0161o metodi, ra\u017eot\u0101ji var noteikt, cik ...<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/lv\/standards\/nf-t54-116\/\"> <span class=\"screen-reader-text\">NF T54-116<\/span> Las\u012bt vair\u0101k \"<\/a><\/p>","protected":false},"author":3,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7336","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/7336","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/comments?post=7336"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/7336\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/media?parent=7336"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}