{"id":7087,"date":"2025-07-21T09:12:31","date_gmt":"2025-07-21T01:12:31","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7087"},"modified":"2025-07-21T09:12:31","modified_gmt":"2025-07-21T01:12:31","slug":"breaking-tester","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/lv\/applications\/breaking-tester\/","title":{"rendered":"K\u0101 lietot ampulu salau\u0161anas testeri: ISO 9187"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"370\" data-end=\"882\">K\u0101 lietot ampulu p\u0101rrau\u0161anas testeri<br \/>\n<small>ISO 9187<\/small><\/h1>\n<hr \/>\n<p data-start=\"299\" data-end=\"916\">Ampulu meh\u0101nisk\u0101s integrit\u0101tes p\u0101rbaude ir \u0101rk\u0101rt\u012bgi svar\u012bga, lai nodro\u0161in\u0101tu dro\u0161u z\u0101\u013cu pieg\u0101di, jo \u012bpa\u0161i attiec\u012bb\u0101 uz injic\u0113jamiem medikamentiem. \u0160is raksts pied\u0101v\u0101 detaliz\u0113tu un profesion\u0101lu ce\u013cvedi par <strong data-start=\"486\" data-end=\"520\">k\u0101 lietot ampulu salau\u0161anas testeri<\/strong> ampul\u0101m, saska\u0146\u0101 ar <a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noopener nofollow\"><strong data-start=\"554\" data-end=\"566\">ISO 9187<\/strong><\/a> standarti. Turkl\u0101t taj\u0101 ir izskaidrots ar\u012b <strong data-start=\"607\" data-end=\"627\">ampulas stiprums<\/strong> test\u0113\u0161anu un ievie\u0161 <strong data-start=\"655\" data-end=\"685\">L\u016bzuma sp\u0113ka test\u0113\u0161anas iek\u0101rta<\/strong> k\u0101 b\u016btisks instruments farmaceitisk\u0101s kvalit\u0101tes kontrol\u0113. Neatkar\u012bgi no t\u0101, vai esat kvalit\u0101tes nodro\u0161in\u0101\u0161anas tehni\u0137is, regulat\u012bv\u0101s atbilst\u012bbas speci\u0101lists vai laboratorijas vad\u012bt\u0101js, \u0161is raksts sniedz praktiski pielietojamas atzi\u0146as, kas tie\u0161i atbalsta j\u016bsu m\u0113r\u0137us atbilst\u012bbas nodro\u0161in\u0101\u0161an\u0101 un produktu integrit\u0101tes saglab\u0101\u0161an\u0101.<\/p>\n<hr \/>\n<h2 data-start=\"299\" data-end=\"916\">Ampulu iztur\u012bbas un ampulu l\u016bzuma sp\u0113ka test\u0113\u0161anas izpratne<\/h2>\n<p data-start=\"982\" data-end=\"1256\"><strong data-start=\"982\" data-end=\"1002\">Ampul\u012btes koncentr\u0101cija<\/strong> attiecas uz ampulas iztur\u012bbu pret \u0101r\u0113jiem meh\u0101niskiem sp\u0113kiem, l\u012bdz t\u0101 p\u0101rtr\u016bkst paredz\u0113taj\u0101 l\u016bzuma viet\u0101. \u0160\u012b l\u016bzuma sp\u0113ka prec\u012bza noteik\u0161ana ir b\u016btiska, lai nodro\u0161in\u0101tu produkta dro\u0161\u012bbu un lieto\u0161anas \u0113rtumu. Nepareizi noteikti l\u016bzuma sp\u0113ki var izrais\u012bt:<\/p>\n<ul>\n<li data-start=\"1260\" data-end=\"1295\">Ampulas sapl\u012b\u0161ana atv\u0113r\u0161anas br\u012bd\u012b<\/li>\n<li data-start=\"1298\" data-end=\"1339\">Pies\u0101r\u0146ojums, ko izraisa nekontrol\u0113ta l\u016bzuma d\u0113\u013c<\/li>\n<li data-start=\"1342\" data-end=\"1393\">Gr\u016bt\u012bbas atv\u0113r\u0161an\u0101 vesel\u012bbas apr\u016bpes speci\u0101listiem<\/li>\n<\/ul>\n<p data-start=\"1395\" data-end=\"1590\">Lai nov\u0113rt\u0113tu \u0161o raksturlielumu, <strong data-start=\"1432\" data-end=\"1462\">L\u016bzuma sp\u0113ka test\u0113\u0161anas iek\u0101rta<\/strong> tam ir iz\u0161\u0137iro\u0161a noz\u012bme. Tas rada stiepes sp\u0113ku ar kontrol\u0113tu \u0101trumu un le\u0146\u0137i, nodro\u0161inot uzticamus un atk\u0101rtojamus m\u0113r\u012bjumus.<\/p>\n<hr \/>\n<h2 data-start=\"1395\" data-end=\"1590\">K\u0101p\u0113c izmantot ampulu l\u016bzuma sp\u0113ka test\u0113\u0161anas iek\u0101rtu?<\/h2>\n<p data-start=\"1639\" data-end=\"1933\">A <strong data-start=\"1641\" data-end=\"1671\">L\u016bzuma sp\u0113ka test\u0113\u0161anas iek\u0101rta<\/strong> nodro\u0161ina prec\u012bzus un standartiz\u0113tus m\u0113r\u012bjumus par to sp\u0113ku, kas nepiecie\u0161ams, lai atdal\u012btu ampulas k\u0101ti\u0146u no t\u0101s korpusa. Saska\u0146\u0101 ar <strong data-start=\"1807\" data-end=\"1826\">ISO 9187-1:2010<\/strong>, 6. punkts \u2014 \u0161\u012b ir noteikt\u0101 metode ampulas meh\u0101nisk\u0101s integrit\u0101tes nov\u0113rt\u0113\u0161anai. Galven\u0101s priek\u0161roc\u012bbas ir \u0161\u0101das:<\/p>\n<ul>\n<li data-start=\"1937\" data-end=\"1998\">Atbilst\u012bba <strong data-start=\"1953\" data-end=\"1967\">ISO 7500-1<\/strong> stiepes izm\u0113\u0123in\u0101jumu iek\u0101rt\u0101m<\/li>\n<li data-start=\"2001\" data-end=\"2058\">Sp\u0113ka diapazons l\u012bdz 200 N, p\u0101rbaudes \u0101trums 10 mm\/min<\/li>\n<li data-start=\"2061\" data-end=\"2089\">Minim\u0101la operatora ietekme<\/li>\n<li data-start=\"2092\" data-end=\"2144\">Sp\u0113ja noteikt, vai boj\u0101jums ir t\u012brs l\u016bzums vai l\u016bzuma veida boj\u0101jums<\/li>\n<\/ul>\n<p data-start=\"2146\" data-end=\"2272\">\u201eCell Instruments\u201c iesaka <strong data-start=\"2178\" data-end=\"2212\">BST-01 Ampu\u013cu lau\u0161anas testeris<\/strong> k\u0101 uzticamu, standartiem atbilsto\u0161u risin\u0101jumu \u0161iem testiem.<\/p>\n<hr \/>\n<h2 data-start=\"2146\" data-end=\"2272\">Soli pa solim: k\u0101 lietot ampulu p\u0101rrau\u0161anas testeri<\/h2>\n<p>Lai nodro\u0161in\u0101tu prec\u012bzus un atbilsto\u0161us testa rezult\u0101tus, iev\u0113rojiet \u0161os s\u012bki izkl\u0101st\u012btos so\u013cus:<\/p>\n<h3>1. <strong data-start=\"2412\" data-end=\"2437\">Sagatavojiet apr\u012bkojumu<\/strong><\/h3>\n<p data-start=\"2438\" data-end=\"2500\">P\u0101rliecinieties, ka iztur\u012bbas test\u0113t\u0101js atbilst standarta ISO 7500-1 pras\u012bb\u0101m:<\/p>\n<ul>\n<li data-start=\"2503\" data-end=\"2537\">Kalibr\u0113ts 200 N sp\u0113ka diapazonam<\/li>\n<li data-start=\"2540\" data-end=\"2578\">Kontrol\u0113ta kust\u012bba pie <strong data-start=\"2563\" data-end=\"2576\">10 mm\/min<\/strong><\/li>\n<li data-start=\"2581\" data-end=\"2643\">Ier\u012bce, kas paredz\u0113ta sp\u0113ka pielieto\u0161anai pie <strong data-start=\"2616\" data-end=\"2623\">90\u00b0<\/strong> uz ampulas asi<\/li>\n<\/ul>\n<p data-start=\"2645\" data-end=\"2775\">Izmantojiet t\u0101du testeri k\u0101 <strong data-start=\"2667\" data-end=\"2694\">Cell Instruments BST-01<\/strong>, kas apr\u012bkots ar ergonomisku nostiprin\u0101\u0161anas sist\u0113mu un digit\u0101lo vad\u012bbu, kas nodro\u0161ina precizit\u0101ti.<\/p>\n<h3 data-start=\"2645\" data-end=\"2775\">2. <strong data-start=\"2784\" data-end=\"2807\">Parauga kondicion\u0113\u0161ana<\/strong><\/h3>\n<p data-start=\"2808\" data-end=\"2851\">Saska\u0146\u0101 ar <strong data-start=\"2821\" data-end=\"2850\">ISO 9187-1, 6.3.2. punkts<\/strong>:<\/p>\n<ul>\n<li data-start=\"2854\" data-end=\"2925\">Ampulas glab\u0101jiet <strong data-start=\"2872\" data-end=\"2885\">20 \u00b1 5 \u00b0C<\/strong> vismaz 24 stundas pirms p\u0101rbaudes.<\/li>\n<li data-start=\"2928\" data-end=\"2999\">Izlases veid\u0101 atlas\u012bt ampulas, pamatojoties uz <strong data-start=\"2962\" data-end=\"2998\">ISO 2859-1, p\u0101rbaudes l\u012bmenis S-4<\/strong>.<\/li>\n<\/ul>\n<h3>3. <strong data-start=\"3008\" data-end=\"3039\">Testa parametru iestat\u012b\u0161ana<\/strong><\/h3>\n<p data-start=\"3040\" data-end=\"3069\">Noregul\u0113jiet testeri \u0161\u0101di:<\/p>\n<ul>\n<li data-start=\"3072\" data-end=\"3114\">Iestatiet sp\u0113ka pielik\u0161anu uz <strong data-start=\"3101\" data-end=\"3114\">10 mm\/min<\/strong><\/li>\n<li data-start=\"3117\" data-end=\"3235\">Novietojiet ampulu t\u0101, lai <strong data-start=\"3147\" data-end=\"3179\">iepriek\u0161 noteikts l\u016bzuma punkts<\/strong> (piem., keramiskais gredzens) ir novietots pa vidu starp met\u0101la stie\u0146iem<\/li>\n<li data-start=\"3238\" data-end=\"3297\">Ir j\u0101pieliek sp\u0113ks <strong data-start=\"3260\" data-end=\"3277\">perpendikul\u0101rs<\/strong> uz ampulas asi<\/li>\n<\/ul>\n<h3>4. <strong data-start=\"3306\" data-end=\"3326\">Veikt testu<\/strong><\/h3>\n<ul>\n<li data-start=\"3329\" data-end=\"3392\">Nostipriniet ampulu ar sa\u0161aurin\u0101jumu starp div\u0101m met\u0101la skav\u0101m<\/li>\n<li data-start=\"3395\" data-end=\"3480\">Iesl\u0113dziet ier\u012bci; t\u0101 autom\u0101tiski piem\u0113ros stiepes sp\u0113ku, l\u012bdz ampula sapl\u012bst<\/li>\n<li data-start=\"3483\" data-end=\"3576\">Re\u0123istr\u0113jiet <strong data-start=\"3494\" data-end=\"3518\">l\u016bzuma sp\u0113ka v\u0113rt\u012bba<\/strong> un nov\u0113rt\u0113jiet l\u016bzuma kvalit\u0101ti (t\u012brs l\u016bzums vai sadrag\u0101ts)\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"ISO 9187-1 ampulu lau\u0161anas testeris BST-01\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/fL78KBZwj3g?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/li>\n<\/ul>\n<h3>5. <strong data-start=\"3585\" data-end=\"3609\">Nov\u0113rt\u0113\u0161ana p\u0113c testa<\/strong><\/h3>\n<p data-start=\"3610\" data-end=\"3722\">Sal\u012bdziniet rezult\u0101tus ar ISO 9187-1 2. tabul\u0101 nor\u0101d\u012btaj\u0101m sp\u0113ka v\u0113rt\u012bb\u0101m. Papildu valid\u0101cija var ietvert:<\/p>\n<ul>\n<li data-start=\"3725\" data-end=\"3766\">P\u0101rbaude, vai l\u016bzuma vietas ir saska\u0146otas<\/li>\n<li data-start=\"3769\" data-end=\"3812\">L\u016bzuma t\u012br\u012bbas nov\u0113ro\u0161ana<\/li>\n<li data-start=\"3815\" data-end=\"3864\">P\u0101rbaude, vai bremz\u0113\u0161anas sp\u0113ks ir vienm\u0113r\u012bgs vis\u0101s partij\u0101s<\/li>\n<\/ul>\n<hr \/>\n<h2>ISO 9187 ampulu l\u016bzuma sp\u0113ka p\u0101rbaudes krit\u0113riji<\/h2>\n<p data-start=\"3917\" data-end=\"4007\">Lai nodro\u0161in\u0101tu atbilst\u012bbu standartiem ISO 9187-1 un 9187-2, j\u016bsu p\u0101rr\u0101vuma sp\u0113ka rezult\u0101tiem j\u0101atbilst \u0161\u0101d\u0101m pras\u012bb\u0101m:<\/p>\n<ul>\n<li data-start=\"4011\" data-end=\"4077\"><strong data-start=\"4011\" data-end=\"4058\">Vienm\u0113r\u012bga bremz\u0113\u0161ana nor\u0101d\u012btaj\u0101 viet\u0101<\/strong> (izcentr\u0113ts \u00b11 mm)<\/li>\n<li data-start=\"4080\" data-end=\"4189\">Iztur\u012bba pret steriliz\u0101ciju: kars\u0113\u0161ana pie <strong data-start=\"4120\" data-end=\"4145\">120 \u00b0C 30 min\u016btes<\/strong>, p\u0113c tam iegremd\u0113jot <strong data-start=\"4172\" data-end=\"4187\">30 \u00b0C \u016bdens<\/strong><\/li>\n<li data-start=\"4192\" data-end=\"4230\">Iztur\u012bba t\u012br\u012b\u0161anas procesu laik\u0101<\/li>\n<li data-start=\"4233\" data-end=\"4297\">Nedr\u012bkst p\u0101rsniegt <strong data-start=\"4246\" data-end=\"4280\">optiskais nob\u012bdums &gt; 50 nm\/mm<\/strong> p\u0113c atkaulo\u0161anas<\/li>\n<\/ul>\n<p data-start=\"4299\" data-end=\"4413\">Ja \u0161ie krit\u0113riji netiek iev\u0113roti, var b\u016bt nepiecie\u0161ams piel\u0101got ampulas ra\u017eo\u0161anas procesu vai l\u016bzuma punkta konstrukciju.<\/p>\n<hr \/>\n<h2 data-start=\"4299\" data-end=\"4413\">K\u0101p\u0113c izv\u0113l\u0113ties \u201eCell Instruments\u201c? <a href=\"https:\/\/www.qualitester.com\/lv\/products-2\/how-to-test-the-force-about-ampoule-breaking\/\">BST-01 Ampu\u013cu lau\u0161anas testeris<\/a>?<\/h2>\n<figure id=\"attachment_7097\" aria-describedby=\"caption-attachment-7097\" style=\"width: 308px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.qualitester.com\/lv\/products-2\/how-to-test-the-force-about-ampoule-breaking\/\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-7097\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Best-ISO-9187-Ampoule-Break-Force-Tester-300x300.webp\" alt=\"k\u0101 lietot ampulu salau\u0161anas testeri\" width=\"308\" height=\"308\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Best-ISO-9187-Ampoule-Break-Force-Tester-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Best-ISO-9187-Ampoule-Break-Force-Tester-1024x1024.webp 1024w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Best-ISO-9187-Ampoule-Break-Force-Tester-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Best-ISO-9187-Ampoule-Break-Force-Tester-768x768.webp 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Best-ISO-9187-Ampoule-Break-Force-Tester-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Best-ISO-9187-Ampoule-Break-Force-Tester-600x600.webp 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Best-ISO-9187-Ampoule-Break-Force-Tester-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/Best-ISO-9187-Ampoule-Break-Force-Tester.webp 1200w\" sizes=\"(max-width: 308px) 100vw, 308px\" \/><\/a><figcaption id=\"caption-attachment-7097\" class=\"wp-caption-text\">BST-01 Ampu\u013cu lau\u0161anas testeris<\/figcaption><\/figure>\n<p data-start=\"4476\" data-end=\"4677\">Ja j\u016bs izv\u0113rt\u0113jat <strong data-start=\"4497\" data-end=\"4531\">k\u0101 lietot l\u016bzuma testeri<\/strong> lai nodro\u0161in\u0101tu atbilst\u012bbu standartam ISO 9187, <strong data-start=\"4565\" data-end=\"4599\">BST-01 Ampu\u013cu lau\u0161anas testeris<\/strong> no <strong data-start=\"4605\" data-end=\"4625\">\u0160\u016bnu instrumenti<\/strong> ir uzticams un lietot\u0101jam draudz\u012bgs risin\u0101jums. Galven\u0101s funkcijas:<\/p>\n<ul>\n<li data-start=\"4681\" data-end=\"4730\">Atbilst <strong data-start=\"4687\" data-end=\"4701\">ISO 7500-1<\/strong> stiepes izm\u0113\u0123in\u0101jumu iek\u0101rtas tehniskie parametri<\/li>\n<li data-start=\"4733\" data-end=\"4779\">Optimiz\u0113ts ampulu kakli\u0146u l\u016bzumu anal\u012bzei<\/li>\n<li data-start=\"4782\" data-end=\"4834\">Piem\u0113rots kvalit\u0101tes nodro\u0161in\u0101\u0161anas laboratorij\u0101m, p\u0113tniec\u012bbas un att\u012bst\u012bbas noda\u013c\u0101m, k\u0101 ar\u012b partiju sertific\u0113\u0161anai<\/li>\n<li data-start=\"4837\" data-end=\"4888\">Papildu datu eksport\u0113\u0161anas un grafiku izveides funkcijas<\/li>\n<\/ul>\n<p data-start=\"4890\" data-end=\"5006\">Uzticama testera izmanto\u0161ana ne tikai nodro\u0161ina atbilst\u012bbu normat\u012bvaj\u0101m pras\u012bb\u0101m, bet ar\u012b stiprina p\u0101rliec\u012bbu par iek\u0161\u0113jo kvalit\u0101tes kontroli.<\/p>\n<hr \/>\n<h2 data-start=\"4890\" data-end=\"5006\">Secin\u0101jums<\/h2>\n<p data-start=\"5028\" data-end=\"5449\">Izpratne par <strong data-start=\"5042\" data-end=\"5076\">k\u0101 lietot l\u016bzuma testeri<\/strong> efekt\u012bvi nodro\u0161ina atbilst\u012bbu <strong data-start=\"5113\" data-end=\"5125\">ISO 9187<\/strong>, nodro\u0161ina produkta integrit\u0101ti un garant\u0113 gala lietot\u0101ja dro\u0161\u012bbu. No pareiz\u0101 testa \u0101truma iestat\u012b\u0161anas l\u012bdz p\u0101rr\u0101vuma kvalit\u0101tes nov\u0113rt\u0113\u0161anai \u2014 katrs solis ir svar\u012bgs. Izmantojot sertific\u0113tu <strong data-start=\"5300\" data-end=\"5330\">Ampulu l\u016bzuma sp\u0113ka test\u0113\u0161anas iek\u0101rta<\/strong> iek\u013caut sav\u0101 darba pl\u016bsm\u0101, piem\u0113ram, <strong data-start=\"5363\" data-end=\"5393\">BST-01, autors <a href=\"https:\/\/www.qualitester.com\/lv\/\">\u0160\u016bnu instrumenti<\/a><\/strong>, nodro\u0161ina efekt\u012bvu un prec\u012bzu ampulu stipr\u012bbas p\u0101rbaudi.<\/p>\n<p data-start=\"5451\" data-end=\"5593\">Apg\u016bstot \u0161\u012bs metodes, j\u016bsu laboratorija vai ra\u017eotne var uzlabot kvalit\u0101tes nodro\u0161in\u0101\u0161anu un iev\u0113rot farmaceitisko iepakojumu standartus.<\/p>\n<hr \/>\n<h2 data-start=\"5451\" data-end=\"5593\">Bie\u017ei uzdotie jaut\u0101jumi<\/h2>\n<p data-start=\"5632\" data-end=\"5826\"><strong data-start=\"5632\" data-end=\"5708\">1. jaut\u0101jums: K\u0101ds ir ide\u0101lais ampulu l\u016bzuma sp\u0113ks saska\u0146\u0101 ar standartu ISO 9187?<\/strong><br data-start=\"5708\" data-end=\"5711\" \/>A1: Standart\u0101 ISO 9187 ir noteiktas v\u0113rt\u012bbas atkar\u012bb\u0101 no ampulas veida un izm\u0113ra. Prec\u012bzas pras\u012bbas skatiet standarta ISO 9187-1 2. tabul\u0101.<\/p>\n<p data-start=\"5828\" data-end=\"5976\"><strong data-start=\"5828\" data-end=\"5887\">2. jaut\u0101jums: Vai 10 mm\/min viet\u0101 var izmantot citus testa \u0101trumus?<\/strong><br data-start=\"5887\" data-end=\"5890\" \/>A2: J\u0101, standarts ISO 9187 at\u013cauj izmantot alternat\u012bvas, piem\u0113ram, 20 N\/s, ja tiek apstiprin\u0101ts, ka rezult\u0101ti ir l\u012bdzv\u0113rt\u012bgi.<\/p>\n<p data-start=\"5978\" data-end=\"6146\"><strong data-start=\"5978\" data-end=\"6037\">3. jaut\u0101jums: Cik bie\u017ei j\u0101kalibr\u0113 iztur\u012bbas test\u0113t\u0101js?<\/strong><br data-start=\"6037\" data-end=\"6040\" \/>A3: To vajadz\u0113tu regul\u0101ri kalibr\u0113t atkar\u012bb\u0101 no izmanto\u0161anas bie\u017euma un vismaz reizi gad\u0101 saska\u0146\u0101 ar standartu ISO 7500-1.<\/p>\n<p data-start=\"6148\" data-end=\"6301\"><strong data-start=\"6148\" data-end=\"6200\">4. jaut\u0101jums: Vai ier\u012bci BST-01 var izmantot plastmasas ampul\u0101m?<\/strong><br data-start=\"6200\" data-end=\"6203\" \/>A4: Tas ir optimiz\u0113ts stikla ampul\u0101m, ta\u010du p\u0113c piepras\u012bjuma var b\u016bt pieejami piel\u0101gojumi plastmasas ampul\u0101m.<\/p>\n<p data-start=\"6303\" data-end=\"6464\"><strong data-start=\"6303\" data-end=\"6362\">5. jaut\u0101jums: Kas notiek, ja ampula nesapl\u012bst vienm\u0113r\u012bgi?<\/strong><br data-start=\"6362\" data-end=\"6365\" \/>A5: Tas var liecin\u0101t par ra\u017eo\u0161anas defektiem vai nepareizu atkaulo\u0161anu. \u0160\u0101di paraugi ir j\u0101noraida.<\/p>","protected":false},"excerpt":{"rendered":"<p>How to use the Ampoule Breaking Tester ISO 9187 Testing the mechanical integrity of ampoules is critical to ensure safe drug delivery, especially for injectable pharmaceuticals. This article offers a detailed and professional guide on how to use the ampoule breaking tester for ampoules, in accordance with ISO 9187 standards. It also explains the role &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/lv\/applications\/breaking-tester\/\"> <span class=\"screen-reader-text\">K\u0101 lietot ampulu salau\u0161anas testeri: ISO 9187<\/span> Las\u012bt vair\u0101k \"<\/a><\/p>","protected":false},"author":3,"featured_media":0,"parent":6794,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7087","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/7087","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/comments?post=7087"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/7087\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/6794"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/media?parent=7087"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}