{"id":6552,"date":"2025-03-12T15:27:02","date_gmt":"2025-03-12T07:27:02","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=6552"},"modified":"2025-03-12T15:29:18","modified_gmt":"2025-03-12T07:29:18","slug":"astm-d3078","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/lv\/standards\/astm-d3078\/","title":{"rendered":"ASTM D3078"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-pm-slice=\"1 1 []\">ASTM D3078<\/h1>\n<p data-pm-slice=\"1 1 []\">Iepakojuma ra\u017eo\u0161anas nozar\u0113 izstr\u0101d\u0101juma integrit\u0101tes nodro\u0161in\u0101\u0161ana ir \u0101rk\u0101rt\u012bgi svar\u012bga. Standarts ASTM D3078, <strong>Standarta test\u0113\u0161anas metode nopl\u016b\u017eu noteik\u0161anai elast\u012bgajos iepakojumos, izmantojot burbu\u013cu emisiju<\/strong>, tiek pla\u0161i izmantots, lai <strong>nopl\u016b\u017eu noteik\u0161ana<\/strong> herm\u0113tiski nosl\u0113gtos iepakojumos. \u0160\u012b metode pal\u012bdz ra\u017eot\u0101jiem saglab\u0101t <a href=\"https:\/\/www.qualitester.com\/lv\/\" target=\"_blank\" rel=\"noopener\"><strong>kvalit\u0101tes kontrole<\/strong><\/a> un atbilst\u012bba nozares standartiem.<\/p>\n<h2 data-pm-slice=\"1 1 []\">Kas ir ASTM D3078?<\/h2>\n<p data-pm-slice=\"1 1 []\"><a href=\"https:\/\/www.qualitester.com\/lv\/produkta-kategorija\/astm\/astm-d3078\/\" target=\"_blank\" rel=\"noopener\">ASTM D3078<\/a> ir <strong>neradot boj\u0101jumus<\/strong> test\u0113\u0161anas metode, kas paredz\u0113ta nopl\u016b\u017eu noteik\u0161anai <strong>elast\u012bgais iepakojums<\/strong> caur <strong>burbu\u013cu izdal\u012b\u0161an\u0101s<\/strong> kad tiek pak\u013cauts vakuuma apst\u0101k\u013ciem. Tas ir \u012bpa\u0161i efekt\u012bvs, lai identific\u0113tu probl\u0113mas ar bl\u012bv\u0113juma integrit\u0101ti <strong>p\u0101rtikas, farmaceitisko un medic\u012bnisko izstr\u0101d\u0101jumu iepakojums<\/strong>.<\/p>\n<h2 data-pm-slice=\"1 1 []\">Burbu\u013cu emisijas tests: darb\u012bbas princips un apr\u012bkojums<\/h2>\n<p data-pm-slice=\"1 1 []\">Port\u0101ls <strong>burbu\u013cu emisijas tests<\/strong> balst\u0101s uz vizu\u0101lu gaisa nopl\u016bdes noteik\u0161anu no zem \u016bdens eso\u0161a iepakojuma, kur\u0101 valda vakuuma spiediens. Nepiecie\u0161amais apr\u012bkojums ietver:<\/p>\n<ul data-spread=\"false\">\n<li><strong>Vakuuma kamera<\/strong>: Caursp\u012bd\u012bgs, vakuumiztur\u012bgs trauks ar iepl\u016bdes\/izpl\u016bdes v\u0101rstu un vakuummetru.<\/li>\n<li><strong>Testa \u0161\u0137idrums<\/strong>: Parasti <strong>\u016bdens<\/strong> vai virsmas akt\u012bv\u0101s vielas \u0161\u0137\u012bdums.<\/li>\n<li><strong>Paraugi<\/strong>: Elast\u012bgs iepakojums ar saturu vai bez t\u0101.<\/li>\n<\/ul>\n<h2>Burbu\u013cu nopl\u016bdes p\u0101rbaudes proced\u016bra<\/h2>\n<p>Port\u0101ls <strong>burbu\u013cu nopl\u016bdes p\u0101rbaudes proced\u016bra<\/strong> veic \u0161\u0101dus so\u013cus:<\/p>\n<ol start=\"1\" data-spread=\"false\">\n<li><strong>Sagatavo\u0161ana<\/strong>: P\u0101rliecinieties, ka testa paraugs un \u0161\u0137idrums atrodas <strong>istabas temperat\u016bra<\/strong>.<\/li>\n<li><strong>Iegremd\u0113\u0161ana<\/strong>: Ievietojiet paraugu vakuuma kamer\u0101 un <strong>piln\u012bb\u0101 iegremd\u0113t<\/strong> to ievietot testa \u0161\u0137idrum\u0101 (vismaz <strong>1 colla\/25 mm<\/strong> (apdro\u0161in\u0101\u0161anas segums).<\/li>\n<li><strong>Vakuuma pielietojums<\/strong>:\n<ul data-spread=\"false\">\n<li>Aizv\u0113rtiet kameru un l\u0113n\u0101m <strong>izveidot vakuumu<\/strong> aptuveni <strong>1 collas Hg\/s<\/strong>.<\/li>\n<li>Piev\u0113rsiet uzman\u012bbu <strong>nep\u0101rtraukta burbu\u013co\u0161ana<\/strong>, kas liecina par nopl\u016bdi.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Aiztur\u0113\u0161ana un nov\u0113ro\u0161ana<\/strong>:\n<ul data-spread=\"false\">\n<li>Uzturiet vakuumu vismaz <strong>30 sekundes<\/strong>.<\/li>\n<li>P\u0101rbaudiet, vai <strong>\u0161\u0137idruma iek\u013c\u016b\u0161ana<\/strong> iepakojuma iek\u0161pus\u0113.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Atbr\u012bvo\u0161ana un p\u0101rbaude<\/strong>: Atvienojiet vakuumu, iz\u0146emiet paraugu un p\u0101rbaudiet, vai taj\u0101 nav palicis testa \u0161\u0137idrums.<\/li>\n<\/ol>\n<h3>Rezult\u0101tu interpret\u0113\u0161ana<\/h3>\n<ul data-spread=\"false\">\n<li><strong>Neiztur p\u0101rbaudi<\/strong>: Ja par\u0101d\u0101s nep\u0101rtrauktas burbu\u013ci vai iepakojum\u0101 iek\u013c\u016bst \u0161\u0137idrums.<\/li>\n<li><strong>Izk\u0101rtojis p\u0101rbaudi<\/strong>: Ja nerodas burbu\u013ci vai \u0161\u0137idruma iek\u013c\u016b\u0161ana.<\/li>\n<\/ul>\n<h2>Standarta ASTM D3078 noz\u012bme iepakojuma kvalit\u0101tes kontrol\u0113<\/h2>\n<ol start=\"1\" data-spread=\"false\">\n<li><strong>Nodro\u0161ina produktu dro\u0161\u012bbu<\/strong>: Nov\u0113r\u0161 pies\u0101r\u0146ojumu <strong>p\u0101rtikas un farmaceitisko produktu iepakojums<\/strong>.<\/li>\n<li><strong>Uzlabo atbilst\u012bbu<\/strong>: Atbilst nozares normat\u012bviem un <strong>kvalit\u0101tes nodro\u0161in\u0101\u0161ana<\/strong> standarti.<\/li>\n<li><strong>Uzlabo iepakojuma integrit\u0101ti<\/strong>: Atkl\u0101j <strong>ra\u017eo\u0161anas defekti<\/strong> agr\u0101k.<\/li>\n<li><strong>Izmaksu zi\u0146\u0101 izdev\u012bgs<\/strong>: Pied\u0101v\u0101 <strong>\u0101tri, uzticami<\/strong> rut\u012bnisko p\u0101rbau\u017eu metode.<\/li>\n<\/ol>\n<h2>Ierobe\u017eojumi un apsv\u0113rumi<\/h2>\n<ul data-spread=\"false\">\n<li>Nav piem\u0113rots <strong>ciets vai pusciets<\/strong> paketes.<\/li>\n<li><strong>Tilpuma palielin\u0101\u0161an\u0101s<\/strong> \u013coti elast\u012bgi risin\u0101jumi var <strong>samazin\u0101t testa jut\u012bbu<\/strong>.<\/li>\n<li>Vakuuma l\u012bmenis j\u0101noregul\u0113 l\u012bdz <strong>izvair\u012bties no trauslu iepakojumu boj\u0101jumiem<\/strong>.<\/li>\n<\/ul>\n<p>Standarts ASTM D3078 ir \u013coti svar\u012bgs <strong>nopl\u016bdes noteik\u0161anas metode<\/strong> elast\u012bgajiem iepakojumiem, nodro\u0161inot <strong>produkta integrit\u0101te un atbilst\u012bba<\/strong>. Tas <strong>burbu\u013cu emisijas tests<\/strong> nodro\u0161ina efekt\u012bvu veidu, k\u0101 identific\u0113t bl\u012bvju defektus, pal\u012bdzot ra\u017eot\u0101jiem uztur\u0113t augstu <strong>kvalit\u0101tes standarti<\/strong> savos iepako\u0161anas procesos.<\/p>","protected":false},"excerpt":{"rendered":"<p>ASTM D3078 In the packaging industry, ensuring product integrity is crucial. ASTM D3078, the Standard Test Method for Determination of Leaks in Flexible Packaging by Bubble Emission, is widely used for leak detection in sealed packages. This method helps manufacturers maintain quality control and compliance with industry standards. What is ASTM D3078? ASTM D3078 is &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/lv\/standards\/astm-d3078\/\"> <span class=\"screen-reader-text\">ASTM D3078<\/span> Las\u012bt vair\u0101k \"<\/a><\/p>","protected":false},"author":4,"featured_media":0,"parent":4948,"menu_order":42,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-6552","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/6552","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/comments?post=6552"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/6552\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/lv\/wp-json\/wp\/v2\/media?parent=6552"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}