{"id":7637,"date":"2025-12-17T17:06:35","date_gmt":"2025-12-17T09:06:35","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7637"},"modified":"2025-12-18T08:17:51","modified_gmt":"2025-12-18T00:17:51","slug":"astm-d5587","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/lt\/standards\/astm-d5587\/","title":{"rendered":"ASTM D5587"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"381\" data-end=\"855\">ASTM D5587<br \/>\n<small>Trapecijos formos audinio ply\u0161imo bandymas<\/small><\/h1>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-7646 alignleft\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D-271x300.webp\" alt=\"ASTM D5587 Trapecijos formos audinio ply\u0161imo bandymas\" width=\"219\" height=\"243\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D-271x300.webp 271w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D-11x12.webp 11w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D.webp 385w\" sizes=\"(max-width: 219px) 100vw, 219px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p data-start=\"479\" data-end=\"979\"><strong data-start=\"479\" data-end=\"493\">ASTM D5587<\/strong> yra pla\u010diai pripa\u017eintas standartas, naudojamas tekstil\u0117s med\u017eiag\u0173 ply\u0161imo savyb\u0117ms nustatyti, kai ply\u0161imas jau yra prasid\u0117j\u0119s. Praktikoje audiniai retai kada ply\u0161ta nuo visi\u0161kai nepa\u017eeisto kra\u0161to. Vietoj to prie\u0161 apkrov\u0105 da\u017enai atsiranda nedideli \u012fpjovimai, defektai arba \u012ftempimo ta\u0161kai. ASTM D5587 standartas atsi\u017evelgia \u012f \u0161i\u0105 realyb\u0119, nes daugiausia d\u0117mesio skiria kontroliuojamam ply\u0161imo plitimui, tod\u0117l jis labai svarbus kokyb\u0117s kontrolei, gamini\u0173 k\u016brimui ir pri\u0117mimo bandymams visoje tekstil\u0117s tiekimo grandin\u0117je.<\/p>\n<p data-start=\"981\" data-end=\"1286\">Gamintojams ir laboratorijoms ASTM D5587 pateikia ai\u0161ki\u0105 sistem\u0105, pagal kuri\u0105 galima gauti palyginamus ir pakartojamus duomenis. Tinkamai \u012fgyvendinta ji padeda in\u017einieriams ir kokyb\u0117s specialistams suprasti, kaip audinio strukt\u016bra, apdaila ir pluo\u0161to sud\u0117tis veikia atsparum\u0105 ply\u0161imui esant tempimo apkrovai.<\/p>\n<h2 data-start=\"1293\" data-end=\"1400\">Paai\u0161kintas audinio ply\u0161imo stiprumo standartas<\/h2>\n<p data-start=\"1402\" data-end=\"1827\">Kaip <strong data-start=\"1407\" data-end=\"1440\">audinio atsparumo ply\u0161imui standartas<\/strong>, ASTM D5587 nurodo<a href=\"https:\/\/www.qualitester.com\/lt\/produktas-2\/tst-01-universal-testing-machine\/\"> <strong data-start=\"1467\" data-end=\"1492\">trapecijos formos ply\u0161imo testas<\/strong> <\/a>atliktas pastovaus tempimo grei\u010dio tempimo testeriu. Skirtingai nuo audini\u0173 tempimo stiprumo bandym\u0173, kai vertinamas tolygus tempimas iki ply\u0161imo, \u0161iuo metodu j\u0117ga sutelkiama i\u0161ilgai apibr\u0117\u017eto ply\u0161imo kelio. Trapecijos formos geometrija u\u017etikrina, kad \u012ftempiai i\u0161likt\u0173 lokalizuoti, tod\u0117l ply\u0161imas tolygiai plinta per vis\u0105 bandinio plot\u012f.<\/p>\n<p data-start=\"1829\" data-end=\"2254\">Standartas taikomas \u012fvairioms med\u017eiagoms, \u012fskaitant audinius, mezginius, sluoksniuotus audinius, plunksnuotus tekstil\u0117s gaminius ir padengtus arba derva apdorotus audinius. Prireikus galima vertinti ir sausas, ir dr\u0117gnas s\u0105lygas. Svarbu tai, kad pagal ASTM D5587 n\u0117ra matuojama j\u0117ga, kurios reikia ply\u0161imui prad\u0117ti, o matuojama j\u0117ga, kurios reikia ply\u0161imui t\u0119sti, o tai da\u017enai labiau atitinka realaus naudojimo savybes.<\/p>\n<p data-start=\"2256\" data-end=\"2444\">Rezultatams prane\u0161ti laboratorijos gali naudoti <strong data-start=\"2307\" data-end=\"2336\">vieno maksimumo ply\u0161imo j\u0117ga<\/strong> arba <strong data-start=\"2344\" data-end=\"2387\">penki\u0173 did\u017eiausi\u0173 maksimali\u0173 j\u0117g\u0173 vidurkis<\/strong>, atsi\u017evelgiant \u012f sutartinius ar specifikacij\u0173 reikalavimus.<\/p>\n<h2 data-start=\"1293\" data-end=\"1400\">Trapecijos formos ply\u0161imo bandymo metodo principas ir pagrindiniai paruo\u0161imo aspektai<\/h2>\n<p data-start=\"2512\" data-end=\"2861\">Trapecijos formos ply\u0161imo bandymas pradedamas kruop\u0161\u010diai paruo\u0161us pavyzd\u012f. Ant sta\u010diakampio formos audinio bandinio pa\u017eymimi lygiakra\u0161\u010dio trapecijos kont\u016brai. Trumpas ply\u0161elis ma\u017eiausio pagrindo centre sukuria kontroliuojam\u0105 pradin\u012f ply\u0161imo ta\u0161k\u0105. Atliekant bandym\u0105 nelygiagre\u010dios trapecijos kra\u0161tin\u0117s u\u017espaud\u017eiamos tempimo bandymo ma\u0161inos \u017enypl\u0117se.<\/p>\n<p data-start=\"2863\" data-end=\"2916\">Keletas paruo\u0161imo detali\u0173 turi tiesiogin\u0117s \u012ftakos tikslumui:<\/p>\n<ul data-start=\"2918\" data-end=\"3164\">\n<li data-start=\"2918\" data-end=\"2991\">\n<p data-start=\"2920\" data-end=\"2991\"><strong data-start=\"2920\" data-end=\"2942\">Bandini\u0173 lyginimas<\/strong> turi i\u0161likti pastovus, kad b\u016bt\u0173 i\u0161vengta netolygaus apkrovimo.<\/p>\n<\/li>\n<li data-start=\"2992\" data-end=\"3069\">\n<p data-start=\"2994\" data-end=\"3069\"><strong data-start=\"2994\" data-end=\"3015\">Prispaudimo sl\u0117gis<\/strong> tur\u0117t\u0173 apsaugoti nuo slydimo, nepa\u017eeisdami audinio.<\/p>\n<\/li>\n<li data-start=\"3070\" data-end=\"3164\">\n<p data-start=\"3072\" data-end=\"3164\"><strong data-start=\"3072\" data-end=\"3102\">Aplinkos kondicionavimas<\/strong> esant standartinei temperat\u016brai ir dr\u0117gmei pagerina pakartojamum\u0105.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3166\" data-end=\"3291\">Atkreipus d\u0117mes\u012f \u012f \u0161iuos veiksnius, galima labiau pasitik\u0117ti ASTM D5587 rezultatais, ypa\u010d lyginant skirting\u0173 laboratorij\u0173 duomenis.<\/p>\n<h2 data-start=\"3298\" data-end=\"3350\">ASTM D5587 proced\u016bros ap\u017evalga \u017eingsnis po \u017eingsnio<\/h2>\n<p data-start=\"3352\" data-end=\"3443\">ASTM D5587 proced\u016br\u0105 galima apibendrinti taip:<\/p>\n<ol data-start=\"3445\" data-end=\"4028\">\n<li data-start=\"3445\" data-end=\"3538\">\n<p data-start=\"3448\" data-end=\"3538\">Jei nenurodyta kitaip, bandinius laikykite standartin\u0117je tekstil\u0117s bandym\u0173 aplinkoje.<\/p>\n<\/li>\n<li data-start=\"3539\" data-end=\"3636\">\n<p data-start=\"3542\" data-end=\"3636\">Pritvirtinkite bandin\u012f tempimo testerio \u017enypl\u0117se i\u0161ilgai nelygiagre\u010di\u0173 trapecijos \u0161on\u0173.<\/p>\n<\/li>\n<li data-start=\"3637\" data-end=\"3712\">\n<p data-start=\"3640\" data-end=\"3712\">Laikykite trump\u0105j\u012f kra\u0161t\u0105 \u012ftempt\u0105 ir u\u017etikrinkite, kad i\u0161 anksto i\u0161pjautas ply\u0161ys likt\u0173 centre.<\/p>\n<\/li>\n<li data-start=\"3713\" data-end=\"3787\">\n<p data-start=\"3716\" data-end=\"3787\">\u012ejunkite tempimo tester\u012f ir pastoviu tempimo grei\u010diu \u012ftempkite apkrov\u0105.<\/p>\n<\/li>\n<li data-start=\"3788\" data-end=\"3861\">\n<p data-start=\"3791\" data-end=\"3861\">Registruokite ply\u0161imo j\u0117g\u0105 plintant ply\u0161iui, atkreipdami d\u0117mes\u012f \u012f did\u017eiausias vertes.<\/p>\n<\/li>\n<li data-start=\"3862\" data-end=\"3941\">\n<p data-start=\"3865\" data-end=\"3941\">Sustabdykite bandym\u0105, kai audinys suply\u0161ta ma\u017edaug 75 mm arba visi\u0161kai suply\u0161ta.<\/p>\n<\/li>\n<li data-start=\"3942\" data-end=\"4028\">\n<p data-start=\"3945\" data-end=\"4028\">Pakartokite bandymus su keliais bandiniais ir kryptimis, kad gautum\u0117te reprezentatyvius duomenis.<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"4030\" data-end=\"4120\">\u0160is strukt\u016brizuotas metodas u\u017etikrina, kad ASTM D5587 rezultatai i\u0161likt\u0173 prasmingi ir palyginami.<\/p>\n<h2 data-start=\"4127\" data-end=\"4190\">Praktin\u0117 reik\u0161m\u0117 kokyb\u0117s kontrolei ir gamybai<\/h2>\n<p data-start=\"4192\" data-end=\"4589\">ASTM D5587 atlieka svarb\u0173 vaidmen\u012f <strong data-start=\"4228\" data-end=\"4281\">komercini\u0173 audini\u0173 siunt\u0173 pri\u0117mimo bandymai<\/strong>. Kilus gin\u010dams tarp tiek\u0117j\u0173 ir pirk\u0117j\u0173, standartas suteikia statisti\u0161kai patikim\u0105 palyginimo pagrind\u0105. Trapecijos formos \u012ftempimo bandymas i\u0161ilgai apibr\u0117\u017eto ruo\u017eo i\u0161ry\u0161kina audimo, verpal\u0173 suri\u0161imo ir apdailos skirtumus, kurie gali nepasireik\u0161ti atliekant kitus mechaninius bandymus.<\/p>\n<p data-start=\"4591\" data-end=\"4774\">Tokiose pramon\u0117s \u0161akose kaip technin\u0117 tekstil\u0117, apsauginiai audiniai, automobili\u0173 interjeras ir pramonin\u0117 pakavimo tekstil\u0117, siekiant patikrinti patvarum\u0105 ir eksploatacini\u0173 savybi\u0173 nuoseklum\u0105, remiamasi ASTM D5587 standartu.<\/p>\n<h2 data-start=\"4781\" data-end=\"4832\">Tinkamo tempimo testerio pasirinkimas pagal ASTM D5587 standart\u0105<\/h2>\n<p data-start=\"4834\" data-end=\"5249\">S\u0117kmingas ASTM D5587 standarto taikymas priklauso nuo stabilios ir tikslios CRE tempimo bandymo ma\u0161inos. . <a href=\"https:\/\/www.qualitester.com\/lt\/produktas-2\/tst-01-tensile-tester\/\"><strong data-start=\"4936\" data-end=\"4971\">\"Cell Instruments\" tempimo testeris<\/strong><\/a> (\"TST-01\") padeda atlikti trapecijos formos ply\u0161imo bandymus, nes u\u017etikrina tiksl\u0173 grei\u010dio valdym\u0105, nuosekl\u0173 poslink\u012f ir patikim\u0105 j\u0117gos matavim\u0105. D\u0117l lankstaus laikikli\u0173 suderinamumo laboratorijos gali greitai prisitaikyti prie skirting\u0173 audini\u0173 tip\u0173, i\u0161laikydamos atitikt\u012f standartiniams reikalavimams.<\/p>\n<p data-start=\"5251\" data-end=\"5410\">Organizacijoms, siekian\u010dioms atlikti patikimus ASTM D5587 bandymus, pasirinkus patikim\u0105 tempimo tester\u012f, padid\u0117ja efektyvumas, duomen\u0173 kokyb\u0117 ir ilgalaikis bandym\u0173 patikimumas.<\/p>\n<figure id=\"attachment_7652\" aria-describedby=\"caption-attachment-7652\" style=\"width: 506px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.qualitester.com\/lt\/produktas-2\/tst-01-universal-testing-machine\/\"><img decoding=\"async\" class=\"wp-image-7652\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/Tearing-Strength-of-Fabric-Testing-1-300x120.webp\" alt=\"Audini\u0173 atsparumo ply\u0161imui bandymai\" width=\"506\" height=\"202\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/Tearing-Strength-of-Fabric-Testing-1-300x120.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/Tearing-Strength-of-Fabric-Testing-1-768x307.webp 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/Tearing-Strength-of-Fabric-Testing-1-18x7.webp 18w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/Tearing-Strength-of-Fabric-Testing-1-600x240.webp 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/Tearing-Strength-of-Fabric-Testing-1.webp 1000w\" sizes=\"(max-width: 506px) 100vw, 506px\" \/><\/a><figcaption id=\"caption-attachment-7652\" class=\"wp-caption-text\">TST-01<\/figcaption><\/figure>\n<h2 data-start=\"5417\" data-end=\"5430\">I\u0161vada<\/h2>\n<p data-start=\"5293\" data-end=\"5594\">ASTM D5587 standarte pateikiamas patikrintas praktinis metodas, skirtas \u012fvertinti audinio atsparum\u0105 ply\u0161imui realiomis s\u0105lygomis. Suderinus standartizuot\u0105 bandini\u0173 geometrij\u0105, kontroliuojam\u0105 apkrov\u0105 ir ai\u0161kias ataskait\u0173 pateikimo galimybes, gamintojai ir laboratorijos gali u\u017etikrintai \u012fvertinti med\u017eiagos eksploatacines savybes. Kartu su auk\u0161tos kokyb\u0117s CRE tempimo testeriu ASTM D5587 tampa galinga audini\u0173 kokyb\u0117s u\u017etikrinimo ir gamini\u0173 optimizavimo priemone.<\/p>\n<h2 data-start=\"5293\" data-end=\"5594\">Da\u017enai u\u017eduodami klausimai<\/h2>\n<p data-start=\"31\" data-end=\"363\"><strong data-start=\"31\" data-end=\"85\">1. K\u0105 ASTM D5587 matuoja atliekant audini\u0173 bandymus?<\/strong><br data-start=\"85\" data-end=\"88\" \/>ASTM D5587 matuoja <em data-start=\"112\" data-end=\"140\">audinio atsparumas ply\u0161imui<\/em> po to, kai jau buvo prad\u0117tas a\u0161arojimas. Daugiausia d\u0117mesio skiriama ply\u0161imo plitimui, o ne ply\u0161imo prad\u017eiai, tod\u0117l rezultatai geriau atspindi realias naudojimo s\u0105lygas, kai audiniuose da\u017enai b\u016bna ma\u017e\u0173 \u012fpjovim\u0173 ar defekt\u0173.<\/p>\n<p data-start=\"365\" data-end=\"746\"><strong data-start=\"365\" data-end=\"453\">2. Kuo skiriasi trapecijos formos ply\u0161imo bandymas nuo audinio tempimo stiprumo bandym\u0173?<\/strong><br data-start=\"453\" data-end=\"456\" \/>Trapecijos formos ply\u0161imo bandymo metu \u012ftempiai sutelkiami i\u0161 anksto nustatytoje ply\u0161imo trajektorijoje, tod\u0117l ply\u0161imas plinta per vis\u0105 bandinio plot\u012f. Prie\u0161ingai, atliekant audinio atsparumo tempimui bandymus, \u012ftempimas yra tolygus iki ply\u0161imo, tod\u0117l \u012fvertinamas bendras stipris, bet ne atsparumas tolesniam ply\u0161imui.<\/p>\n<p data-start=\"748\" data-end=\"1064\"><strong data-start=\"748\" data-end=\"815\">3. Koki\u0173 tip\u0173 audiniai gali b\u016bti bandomi pagal ASTM D5587 standart\u0105?<\/strong><br data-start=\"815\" data-end=\"818\" \/>ASTM D5587 standartas taikomas daugumai tekstil\u0117s audini\u0173, \u012fskaitant austus, megztus, sluoksniuotus, plau\u0161inius, plau\u0161inius ir dengtus audinius. Jis taip pat taikomas neapdorotiems, didelio dyd\u017eio, derva apdorotiems ir specialiesiems tekstil\u0117s gaminiams, numatant bandymus sausomis ir dr\u0117gnomis s\u0105lygomis.<\/p>","protected":false},"excerpt":{"rendered":"<p>ASTM D5587 Trapecijos formos audinio ply\u0161imo bandymas ASTM D5587 yra pla\u010diai pripa\u017eintas standartas, naudojamas tekstil\u0117s med\u017eiag\u0173 ply\u0161imo savyb\u0117ms nustatyti, kai ply\u0161imas jau prasid\u0117jo. Praktikoje audiniai retai kada ply\u0161ta nuo visi\u0161kai nepa\u017eeisto kra\u0161to. Vietoj to prie\u0161 apkrov\u0105 da\u017enai atsiranda nedideli \u012fpjovimai, defektai arba \u012ftempimo ta\u0161kai. ASTM ...<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/lt\/standards\/astm-d5587\/\"> <span class=\"screen-reader-text\">ASTM D5587<\/span> Skaityti daugiau \"<\/a><\/p>","protected":false},"author":8,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7637","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/lt\/wp-json\/wp\/v2\/pages\/7637","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/lt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/lt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lt\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lt\/wp-json\/wp\/v2\/comments?post=7637"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/lt\/wp-json\/wp\/v2\/pages\/7637\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/lt\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/lt\/wp-json\/wp\/v2\/media?parent=7637"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}