{"id":7147,"date":"2025-07-21T15:38:38","date_gmt":"2025-07-21T07:38:38","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7147"},"modified":"2025-07-23T14:11:17","modified_gmt":"2025-07-23T06:11:17","slug":"iso-12048-compression-tester","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/it\/applications\/iso-12048-compression-tester\/","title":{"rendered":"Tester di compressione ISO 12048"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"7147\" class=\"elementor elementor-7147\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c3dde40 e-flex e-con-boxed e-con e-parent\" data-id=\"c3dde40\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8df9979 elementor-widget elementor-widget-heading\" data-id=\"8df9979\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Tester di compressione ISO 12048<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4a6f8e0 e-flex e-con-boxed e-con e-parent\" data-id=\"4a6f8e0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7f357f7 elementor-widget elementor-widget-text-editor\" data-id=\"7f357f7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"565\" data-end=\"1140\">In industries such as <strong data-start=\"587\" data-end=\"606\">medical devices<\/strong>, <strong data-start=\"608\" data-end=\"627\">prodotti farmaceutici<\/strong>, <strong data-start=\"629\" data-end=\"637\">cibo<\/strong>, e <strong data-start=\"643\" data-end=\"656\">logistics<\/strong>, packaging failure can lead to significant losses and safety risks. One of the most effective ways to prevent this is through the use of an <strong data-start=\"797\" data-end=\"829\">ISO 12048 compression tester<\/strong>, which provides standardized, repeatable methods for evaluating the structural resilience of packaging materials. This article explains how these testers work, how they align with international standards, and how they support high-precision <strong data-start=\"1071\" data-end=\"1113\">packaging compressive strength testing<\/strong> across various industries.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8280a96 e-flex e-con-boxed e-con e-parent\" data-id=\"8280a96\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-42c5037 elementor-widget elementor-widget-heading\" data-id=\"42c5037\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Understanding the Importance of ISO 12048 Compression Tester<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-19464bb e-flex e-con-boxed e-con e-parent\" data-id=\"19464bb\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-003944b elementor-widget elementor-widget-text-editor\" data-id=\"003944b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1213\" data-end=\"1579\">Il <strong data-start=\"1217\" data-end=\"1249\">ISO 12048 compression tester<\/strong> plays a pivotal role in packaging engineering. It is specifically designed to simulate vertical stacking forces that packages endure during storage and transportation. This testing is crucial for verifying whether a packaging system can <strong data-start=\"1487\" data-end=\"1516\">sustain compression loads<\/strong> without deforming, collapsing, or compromising product safety.<\/p><p data-start=\"1581\" data-end=\"1695\">Unlike generic load-bearing devices, ISO 12048-compliant testers adhere to strict performance guidelines, such as:<\/p><ul data-start=\"1697\" data-end=\"1866\"><li data-start=\"1697\" data-end=\"1728\"><p data-start=\"1699\" data-end=\"1728\"><strong data-start=\"1699\" data-end=\"1728\">Force accuracy within \u00b12%<\/strong><\/p><\/li><li data-start=\"1729\" data-end=\"1771\"><p data-start=\"1731\" data-end=\"1771\"><strong data-start=\"1731\" data-end=\"1771\">Parallelism of platens within 1:1000<\/strong><\/p><\/li><li data-start=\"1772\" data-end=\"1816\"><p data-start=\"1774\" data-end=\"1816\"><strong data-start=\"1774\" data-end=\"1816\">Constant test speed at (10 \u00b1 3) mm\/min<\/strong><\/p><\/li><li data-start=\"1817\" data-end=\"1866\"><p data-start=\"1819\" data-end=\"1866\"><strong data-start=\"1819\" data-end=\"1866\">Continuous force-deformation data recording<\/strong><\/p><\/li><\/ul><p data-start=\"1868\" data-end=\"2023\">These requirements ensure that test results are not only accurate but also internationally comparable\u2014vital for global supply chains and regulatory audits.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c65465b e-flex e-con-boxed e-con e-parent\" data-id=\"c65465b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-843cca8 elementor-widget elementor-widget-heading\" data-id=\"843cca8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Packaging Compressive Strength Testing: Core Applications and Process<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4d4cb21 e-flex e-con-boxed e-con e-parent\" data-id=\"4d4cb21\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9b2432a elementor-widget elementor-widget-text-editor\" data-id=\"9b2432a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2105\" data-end=\"2381\"><strong data-start=\"2105\" data-end=\"2147\">Packaging compressive strength testing<\/strong> involves applying a vertical force to a fully packed sample until it either deforms, collapses, or reaches a predefined threshold. The goal is to assess how well a packaging design can protect its contents when stacked or under load.<\/p><p data-start=\"2383\" data-end=\"2440\">This method applies to various packaging types including:<\/p><ul data-start=\"2442\" data-end=\"2599\"><li data-start=\"2442\" data-end=\"2476\"><p data-start=\"2444\" data-end=\"2476\"><strong data-start=\"2444\" data-end=\"2476\">Infusion bags and blood bags<\/strong><\/p><\/li><li data-start=\"2477\" data-end=\"2525\"><p data-start=\"2479\" data-end=\"2525\"><strong data-start=\"2479\" data-end=\"2525\">Plastic bottles and laminated film pouches<\/strong><\/p><\/li><li data-start=\"2526\" data-end=\"2565\"><p data-start=\"2528\" data-end=\"2565\"><strong data-start=\"2528\" data-end=\"2565\">Corrugated boxes, trays, and cups<\/strong><\/p><\/li><li data-start=\"2566\" data-end=\"2599\"><p data-start=\"2568\" data-end=\"2599\"><strong data-start=\"2568\" data-end=\"2599\">Composite medical packaging<\/strong><\/p><\/li><\/ul><p data-start=\"2601\" data-end=\"2727\">A <strong data-start=\"2604\" data-end=\"2624\">Strumenti a cella<\/strong>, we offer the <strong data-start=\"2639\" data-end=\"2676\">PCT-01 Tester di compressione dei pacchetti<\/strong>\u2014a powerful tool engineered for this exact purpose.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-71e6554 e-flex e-con-boxed e-con e-parent\" data-id=\"71e6554\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-14c12df elementor-widget elementor-widget-heading\" data-id=\"14c12df\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Step-by-Step: Conducting a Standardized Compression Test<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c8b4f13 e-flex e-con-boxed e-con e-parent\" data-id=\"c8b4f13\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7bf2180 elementor-widget elementor-widget-text-editor\" data-id=\"7bf2180\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2796\" data-end=\"2866\">To ensure compliance with <a href=\"https:\/\/www.packqc.com\/standards-iso-12048\/\" target=\"_blank\" rel=\"noopener nofollow\"><strong data-start=\"2822\" data-end=\"2835\">ISO 12048<\/strong><\/a>, follow these essential steps:<\/p><p data-start=\"2868\" data-end=\"3091\"><strong data-start=\"2868\" data-end=\"2894\">1. Sample Conditioning<\/strong><br data-start=\"2894\" data-end=\"2897\" \/>Before testing, all specimens must be conditioned for at least 48 hours at <strong data-start=\"2972\" data-end=\"3006\">23\u00b0C and 50% relative humidity<\/strong>. This ensures consistency by stabilizing moisture content and mechanical properties.<\/p><p data-start=\"3093\" data-end=\"3259\"><strong data-start=\"3093\" data-end=\"3116\">2. Instrument Setup<\/strong><br data-start=\"3116\" data-end=\"3119\" \/>Position the sample securely between <strong data-start=\"3156\" data-end=\"3188\">parallel compression platens<\/strong>. Misalignment can cause stress concentrations and inaccurate readings.<\/p><p data-start=\"3261\" data-end=\"3341\"><strong data-start=\"3261\" data-end=\"3291\">3. Parameter Configuration<\/strong><br data-start=\"3291\" data-end=\"3294\" \/>Set the test to one of the following endpoints:<\/p><ul data-start=\"3342\" data-end=\"3430\"><li data-start=\"3342\" data-end=\"3372\"><p data-start=\"3344\" data-end=\"3372\">A specified <strong data-start=\"3356\" data-end=\"3372\">maximum load<\/strong><\/p><\/li><li data-start=\"3373\" data-end=\"3406\"><p data-start=\"3375\" data-end=\"3406\">A defined <strong data-start=\"3385\" data-end=\"3406\">deformation level<\/strong><\/p><\/li><li data-start=\"3407\" data-end=\"3430\"><p data-start=\"3409\" data-end=\"3430\"><strong data-start=\"3409\" data-end=\"3430\">Complete collapse<\/strong><\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0b9b55f e-flex e-con-boxed e-con e-parent\" data-id=\"0b9b55f\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-fb558dc e-con-full e-flex e-con e-child\" data-id=\"fb558dc\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-be67aa2 elementor-widget elementor-widget-video\" data-id=\"be67aa2\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=Zcv0ejzEkW0&quot;,&quot;autoplay&quot;:&quot;yes&quot;,&quot;play_on_mobile&quot;:&quot;yes&quot;,&quot;mute&quot;:&quot;yes&quot;,&quot;loop&quot;:&quot;yes&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-239301a e-con-full e-flex e-con e-child\" data-id=\"239301a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8884a0a elementor-widget elementor-widget-text-editor\" data-id=\"8884a0a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3432\" data-end=\"3562\">Configure the compression speed at <strong data-start=\"3467\" data-end=\"3490\">10 mm\/min \u00b13 mm\/min<\/strong>, and ensure overload protection and emergency stop features are active.<\/p><p data-start=\"3564\" data-end=\"3700\"><strong data-start=\"3564\" data-end=\"3585\">4. Test Execution<\/strong><br data-start=\"3585\" data-end=\"3588\" \/>Start the test. The machine will compress the sample while recording a <strong data-start=\"3659\" data-end=\"3686\">force-deformation curve<\/strong> in real time.<\/p><p data-start=\"3702\" data-end=\"3758\"><strong data-start=\"3702\" data-end=\"3722\">5. Data Analysis<\/strong><br data-start=\"3722\" data-end=\"3725\" \/>Interpret results by identifying:<\/p><ul data-start=\"3759\" data-end=\"3877\"><li data-start=\"3759\" data-end=\"3800\"><p data-start=\"3761\" data-end=\"3800\"><strong data-start=\"3761\" data-end=\"3775\">Peak force<\/strong> sustained before failure<\/p><\/li><li data-start=\"3801\" data-end=\"3826\"><p data-start=\"3803\" data-end=\"3826\"><strong data-start=\"3803\" data-end=\"3826\">Percent deformation<\/strong><\/p><\/li><li data-start=\"3827\" data-end=\"3877\"><p data-start=\"3829\" data-end=\"3877\"><strong data-start=\"3829\" data-end=\"3845\">Failure mode<\/strong> (buckling, rupture, or leakage)<\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d181b8e e-flex e-con-boxed e-con e-parent\" data-id=\"d181b8e\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a7cb7f elementor-widget elementor-widget-heading\" data-id=\"3a7cb7f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How Cell Instruments\u2019 PCT-01 Elevates Packaging Strength Testing<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-42342f5 e-flex e-con-boxed e-con e-parent\" data-id=\"42342f5\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-1c8d40c e-con-full e-flex e-con e-child\" data-id=\"1c8d40c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b4c2171 elementor-widget elementor-widget-image\" data-id=\"b4c2171\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"768\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.PCT-01-Compression-Tester_11zon-768x768.webp\" class=\"attachment-medium_large size-medium_large wp-image-7152\" alt=\"ISO 12048 compression tester via packaging compressive strength testing.\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.PCT-01-Compression-Tester_11zon-768x768.webp 768w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.PCT-01-Compression-Tester_11zon-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.PCT-01-Compression-Tester_11zon-1024x1024.webp 1024w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.PCT-01-Compression-Tester_11zon-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.PCT-01-Compression-Tester_11zon-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.PCT-01-Compression-Tester_11zon-600x600.webp 600w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.PCT-01-Compression-Tester_11zon-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/07\/3.PCT-01-Compression-Tester_11zon.webp 1080w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f25fe95 e-con-full e-flex e-con e-child\" data-id=\"f25fe95\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4c895f4 elementor-widget elementor-widget-text-editor\" data-id=\"4c895f4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3954\" data-end=\"4149\">Il <a href=\"https:\/\/www.qualitester.com\/it\/prodotto-2\/sale-bag-compression-tester\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"3958\" data-end=\"3995\">PCT-01 Tester di compressione dei pacchetti<\/strong> <\/a>da <strong data-start=\"4001\" data-end=\"4021\">Strumenti a cella<\/strong> offers superior performance for <a href=\"https:\/\/www.packqc.com\/standards-iso-12048\/\" target=\"_blank\" rel=\"noopener nofollow\"><strong data-start=\"4054\" data-end=\"4085\">ISO 12048 compression tests<\/strong><\/a>, with tailored features that address real-world industry needs:<\/p><ul data-start=\"4151\" data-end=\"4633\"><li data-start=\"4151\" data-end=\"4211\"><p data-start=\"4153\" data-end=\"4211\"><strong data-start=\"4153\" data-end=\"4172\">HMI touchscreen<\/strong> interface for easy parameter setting<\/p><\/li><li data-start=\"4212\" data-end=\"4270\"><p data-start=\"4214\" data-end=\"4270\"><strong data-start=\"4214\" data-end=\"4240\">Industrial PLC control<\/strong> for stability and precision<\/p><\/li><li data-start=\"4271\" data-end=\"4331\"><p data-start=\"4273\" data-end=\"4331\"><strong data-start=\"4273\" data-end=\"4291\">Two test modes<\/strong>: bursting force and constant pressure<\/p><\/li><li data-start=\"4332\" data-end=\"4394\"><p data-start=\"4334\" data-end=\"4394\"><strong data-start=\"4334\" data-end=\"4369\">Automatic pressure compensation<\/strong> for repeatable results<\/p><\/li><li data-start=\"4395\" data-end=\"4487\"><p data-start=\"4397\" data-end=\"4487\"><strong data-start=\"4397\" data-end=\"4432\">Built-in liquid collection tray<\/strong> for testing flexible packaging (e.g., infusion bags)<\/p><\/li><li data-start=\"4488\" data-end=\"4551\"><p data-start=\"4490\" data-end=\"4551\"><strong data-start=\"4490\" data-end=\"4524\">Customizable platen dimensions<\/strong> for non-standard samples<\/p><\/li><li data-start=\"4552\" data-end=\"4633\"><p data-start=\"4554\" data-end=\"4633\">Opzionale <strong data-start=\"4563\" data-end=\"4593\">RS232 port and PC software<\/strong> for seamless data export and analysis<\/p><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-513273d e-flex e-con-boxed e-con e-parent\" data-id=\"513273d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c09063b elementor-widget elementor-widget-text-editor\" data-id=\"c09063b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>This instrument supports both <strong data-start=\"4665\" data-end=\"4689\">quality control labs<\/strong> e <strong data-start=\"4694\" data-end=\"4707\">R&amp;D teams<\/strong> in sectors where packaging performance directly impacts <strong data-start=\"4764\" data-end=\"4782\">patient safety<\/strong>, <strong data-start=\"4784\" data-end=\"4805\">product integrity<\/strong>, e <strong data-start=\"4811\" data-end=\"4836\">regulatory compliance<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e834e54 e-flex e-con-boxed e-con e-parent\" data-id=\"e834e54\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7f4aa9a elementor-widget elementor-widget-heading\" data-id=\"7f4aa9a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standard References: ISO 12048 and ASTM D642<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c02010a e-flex e-con-boxed e-con e-parent\" data-id=\"c02010a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c2df08f elementor-widget elementor-widget-text-editor\" data-id=\"c2df08f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4894\" data-end=\"5022\">Entrambi <strong data-start=\"4899\" data-end=\"4912\">ISO 12048<\/strong> e <strong data-start=\"4917\" data-end=\"4930\">ASTM D642<\/strong> define methodologies for compression and stacking tests. These standards are essential for:<\/p><ul data-start=\"5024\" data-end=\"5141\"><li data-start=\"5024\" data-end=\"5057\"><p data-start=\"5026\" data-end=\"5057\"><strong data-start=\"5026\" data-end=\"5057\">Packaging design validation<\/strong><\/p><\/li><li data-start=\"5058\" data-end=\"5083\"><p data-start=\"5060\" data-end=\"5083\"><strong data-start=\"5060\" data-end=\"5083\">Material comparison<\/strong><\/p><\/li><li data-start=\"5084\" data-end=\"5113\"><p data-start=\"5086\" data-end=\"5113\"><strong data-start=\"5086\" data-end=\"5113\">Supply chain robustness<\/strong><\/p><\/li><li data-start=\"5114\" data-end=\"5141\"><p data-start=\"5116\" data-end=\"5141\"><strong data-start=\"5116\" data-end=\"5141\">Regulatory submission<\/strong><\/p><\/li><\/ul><p data-start=\"5143\" data-end=\"5177\">Key points from ISO 12048 include:<\/p><ul data-start=\"5179\" data-end=\"5376\"><li data-start=\"5179\" data-end=\"5232\"><p data-start=\"5181\" data-end=\"5232\">Continuous recording of <strong data-start=\"5205\" data-end=\"5230\">force vs. deformation<\/strong><\/p><\/li><li data-start=\"5233\" data-end=\"5308\"><p data-start=\"5235\" data-end=\"5308\">Detailed reporting of <strong data-start=\"5257\" data-end=\"5306\">test speed, preconditioning, and failure mode<\/strong><\/p><\/li><li data-start=\"5309\" data-end=\"5376\"><p data-start=\"5311\" data-end=\"5376\">Evaluation of <strong data-start=\"5325\" data-end=\"5376\">structural integrity and protection performance<\/strong><\/p><\/li><\/ul><p data-start=\"5378\" data-end=\"5508\">Adhering to these standards enhances credibility and ensures global compliance\u2014especially for exporters or contract manufacturers.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-955a872 e-flex e-con-boxed e-con e-parent\" data-id=\"955a872\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-69ab887 elementor-widget elementor-widget-heading\" data-id=\"69ab887\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusione<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-332471c e-flex e-con-boxed e-con e-parent\" data-id=\"332471c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-39ce74a elementor-widget elementor-widget-text-editor\" data-id=\"39ce74a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>An <strong data-start=\"5534\" data-end=\"5566\">ISO 12048 compression tester<\/strong> is not just a tool\u2014it\u2019s a gateway to better packaging performance, fewer product losses, and stronger regulatory confidence. By mastering<a href=\"https:\/\/www.pharmacopoeiatest.com\/packaging-compression-strength-tester\/\" target=\"_blank\" rel=\"noopener nofollow\"> <strong data-start=\"5705\" data-end=\"5747\">packaging compressive strength testing<\/strong><\/a>, companies can make data-driven decisions, optimize material usage, and enhance the durability of their packaging designs.<\/p><p><strong data-start=\"5872\" data-end=\"5902\">Strumenti a cella <\/strong>provides world-class testing solutions that are <strong data-start=\"5951\" data-end=\"5963\">accurate<\/strong>, <strong data-start=\"5965\" data-end=\"5977\">reliable<\/strong>, e <strong data-start=\"5983\" data-end=\"6005\">standard-compliant<\/strong>. Whether you\u2019re developing packaging for infusion bags or shipping cartons, the <a href=\"https:\/\/www.qualitester.com\/it\/prodotto-2\/sale-bag-compression-tester\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"6086\" data-end=\"6096\">PCT-01<\/strong><\/a> will empower your team to achieve precise, repeatable results that stand up to global demands.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Tester di compressione ISO 12048 In settori quali i dispositivi medici, i prodotti farmaceutici, gli alimenti e la logistica, i guasti agli imballaggi possono comportare perdite significative e rischi per la sicurezza. Uno dei modi pi\u00f9 efficaci per prevenirli \u00e8 l'uso di un tester di compressione ISO 12048, che fornisce metodi standardizzati e ripetibili per valutare la resistenza strutturale degli imballaggi ...<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/it\/applications\/iso-12048-compression-tester\/\"> <span class=\"screen-reader-text\">Tester di compressione ISO 12048<\/span> Leggi altro \u00bb<\/a><\/p>","protected":false},"author":3,"featured_media":0,"parent":6794,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7147","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/pages\/7147","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/comments?post=7147"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/pages\/7147\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/pages\/6794"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/media?parent=7147"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}