{"id":6648,"date":"2025-05-09T11:42:03","date_gmt":"2025-05-09T03:42:03","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=6648"},"modified":"2025-11-13T09:38:29","modified_gmt":"2025-11-13T01:38:29","slug":"iso-7886-1","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/it\/standards\/iso-7886-1\/","title":{"rendered":"ISO 7886-1"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"370\" data-end=\"882\"><small>ISO 7886-1<\/small><\/h1>\n<h1 style=\"text-align: center;\" data-start=\"370\" data-end=\"882\"><small>Hypodermic Syringe Test<\/small><\/h1>\n<p class=\"\" data-start=\"370\" data-end=\"882\">Il <strong data-start=\"349\" data-end=\"363\">ISO 7886-1<\/strong> standard defines the performance and safety requirements for <em data-start=\"425\" data-end=\"446\">hypodermic syringes<\/em> intended for single use, emphasizing aspects like <em data-start=\"497\" data-end=\"514\">leak resistance<\/em>, <em data-start=\"516\" data-end=\"528\">dead space<\/em>, e <em data-start=\"534\" data-end=\"547\">glide force<\/em>. Manufacturers and quality assurance teams must understand the testing procedures outlined in ISO 7886-1 to ensure product compliance and patient safety.<\/p>\n<p class=\"\" data-start=\"1369\" data-end=\"1391\">ISO 7886-1 applies to:<\/p>\n<ul data-start=\"1393\" data-end=\"1559\">\n<li class=\"\" data-start=\"1393\" data-end=\"1438\">\n<p class=\"\" data-start=\"1395\" data-end=\"1438\">Sterile syringes made of plastic materials.<\/p>\n<\/li>\n<li class=\"\" data-start=\"1439\" data-end=\"1523\">\n<p class=\"\" data-start=\"1441\" data-end=\"1523\">Syringes used with hypodermic needles for subcutaneous or intramuscular injection.<\/p>\n<\/li>\n<li class=\"\" data-start=\"1524\" data-end=\"1559\">\n<p class=\"\" data-start=\"1526\" data-end=\"1559\">Syringes intended for single use.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"1561\" data-end=\"1706\">This standard does <strong data-start=\"1580\" data-end=\"1593\">not apply<\/strong> to syringes for insulin (covered by ISO 8537), dental use (covered by ISO 7885), or syringes for infusion pumps.<\/p>\n<hr class=\"\" data-start=\"884\" data-end=\"887\" \/>\n<h2 class=\"\" data-start=\"912\" data-end=\"952\">ISO 7886 Testing and Its Significance<\/h2>\n<p class=\"\" data-start=\"954\" data-end=\"1117\"><strong data-start=\"954\" data-end=\"968\">ISO 7886-1<\/strong> focuses on performance requirements and test methods for <em data-start=\"1026\" data-end=\"1047\">hypodermic syringes<\/em>, particularly those used with or without needles. These tests ensure:<\/p>\n<h3 class=\"\" data-start=\"1861\" data-end=\"1895\">1. <strong data-start=\"1868\" data-end=\"1895\">Design and Construction<\/strong><\/h3>\n<ul data-start=\"1896\" data-end=\"2054\">\n<li class=\"\" data-start=\"1896\" data-end=\"1951\">\n<p class=\"\" data-start=\"1898\" data-end=\"1951\">Transparent barrel for visual inspection of contents.<\/p>\n<\/li>\n<li class=\"\" data-start=\"1952\" data-end=\"1997\">\n<p class=\"\" data-start=\"1954\" data-end=\"1997\">Graduated scale printed with permanent ink.<\/p>\n<\/li>\n<li class=\"\" data-start=\"1998\" data-end=\"2054\">\n<p class=\"\" data-start=\"2000\" data-end=\"2054\">Secure plunger fit to prevent leakage or dislodgement.<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2056\" data-end=\"2082\">2. <strong data-start=\"2063\" data-end=\"2082\">Volume Accuracy<\/strong><\/h3>\n<ul data-start=\"2083\" data-end=\"2260\">\n<li class=\"\" data-start=\"2083\" data-end=\"2192\">\n<p class=\"\" data-start=\"2085\" data-end=\"2192\">The actual delivered volume must match the nominal volume marked on the barrel within specified tolerances.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2193\" data-end=\"2260\">\n<p class=\"\" data-start=\"2195\" data-end=\"2260\">Accuracy is tested at 10%, 50%, and 100% of the nominal capacity.<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2262\" data-end=\"2286\">3. <strong data-start=\"2269\" data-end=\"2286\">Leakage Tests<\/strong><\/h3>\n<ul data-start=\"2287\" data-end=\"2457\">\n<li class=\"\" data-start=\"2287\" data-end=\"2384\">\n<p class=\"\" data-start=\"2289\" data-end=\"2384\"><strong data-start=\"2289\" data-end=\"2304\">Air leakage<\/strong> e <strong data-start=\"2309\" data-end=\"2327\">liquid leakage<\/strong> are tested under defined pressure and volume conditions.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2385\" data-end=\"2457\">\n<p class=\"\" data-start=\"2387\" data-end=\"2457\">No visible leakage should occur from the barrel or between components.<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2459\" data-end=\"2480\">4. <strong data-start=\"2466\" data-end=\"2480\">Dead Space<\/strong><\/h3>\n<ul data-start=\"2481\" data-end=\"2614\">\n<li class=\"\" data-start=\"2481\" data-end=\"2614\">\n<p class=\"\" data-start=\"2483\" data-end=\"2614\">The volume remaining in the syringe after full depression of the plunger must not exceed the specified maximum (usually \u2264 0.07 mL).<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2616\" data-end=\"2643\">5. <strong data-start=\"2623\" data-end=\"2643\">Plunger Function<\/strong><\/h3>\n<ul data-start=\"2644\" data-end=\"2782\">\n<li class=\"\" data-start=\"2644\" data-end=\"2708\">\n<p class=\"\" data-start=\"2646\" data-end=\"2708\">The plunger should move smoothly without sticking or slipping.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2709\" data-end=\"2782\">\n<p class=\"\" data-start=\"2711\" data-end=\"2782\">There must be no leakage or separation under normal operating pressure.<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2784\" data-end=\"2827\">6. <strong data-start=\"2791\" data-end=\"2827\">Break Force and Separation Force<\/strong><\/h3>\n<ul data-start=\"2828\" data-end=\"2945\">\n<li class=\"\" data-start=\"2828\" data-end=\"2945\">\n<p class=\"\" data-start=\"2830\" data-end=\"2945\">The maximum force required to break the plunger or separate the components should not fall below safety thresholds.<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"\" data-start=\"2947\" data-end=\"2974\">7. <strong data-start=\"2954\" data-end=\"2974\">Biocompatibility<\/strong><\/h3>\n<ul data-start=\"2975\" data-end=\"3080\">\n<li class=\"\" data-start=\"2975\" data-end=\"3080\">\n<p class=\"\" data-start=\"2977\" data-end=\"3080\">Materials in contact with the drug or injection site must pass ISO 10993 series biocompatibility tests.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"1313\" data-end=\"1462\">Each test helps determine if a syringe is safe, reliable, and consistent in performance.<\/p>\n<hr class=\"\" data-start=\"1766\" data-end=\"1769\" \/>\n<h2 class=\"\" data-start=\"1568\" data-end=\"1616\">Hypodermic Syringe Test Methods in ISO 7886-1<\/h2>\n<h3 class=\"\" data-start=\"1618\" data-end=\"1673\">1. Hypodermic Syringe Leak Test Under Vacuum (Annex B)<img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-6651 alignright\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-B.webp\" alt=\"ISO 7886-1 Annex B\" width=\"398\" height=\"327\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-B.webp 694w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-B-300x246.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-B-15x12.webp 15w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-B-600x493.webp 600w\" sizes=\"(max-width: 398px) 100vw, 398px\" \/><\/h3>\n<p class=\"\" data-start=\"1675\" data-end=\"1866\">Leakage past the plunger stopper under negative pressure must be tested to avoid contamination or air intrusion. This <strong data-start=\"1793\" data-end=\"1825\">hypodermic syringe leak test<\/strong> is essential for verifying airtightness.<\/p>\n<ul data-start=\"1868\" data-end=\"2062\">\n<li class=\"\" data-start=\"1868\" data-end=\"1979\">\n<p class=\"\" data-start=\"1870\" data-end=\"1979\"><strong data-start=\"1870\" data-end=\"1881\">Method:<\/strong> Fill the syringe with water (at least 25% capacity), clamp the plunger, and apply -88 kPa vacuum.<\/p>\n<\/li>\n<li class=\"\" data-start=\"1980\" data-end=\"2062\">\n<p class=\"\" data-start=\"1982\" data-end=\"2062\"><strong data-start=\"1982\" data-end=\"1998\">Observation:<\/strong> Inspect for any air leaks or detachment of the plunger stopper.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"2064\" data-end=\"2229\"><strong data-start=\"2064\" data-end=\"2090\">Attrezzatura consigliata:<\/strong><br data-start=\"2090\" data-end=\"2093\" \/>Strumenti di cella <strong data-start=\"2111\" data-end=\"2141\">SLT-02 <a href=\"https:\/\/www.qualitester.com\/it\/prodotto-2\/syringe-air-leakage-tester-iso-7886-1\/\">Tester per siringhe<\/a><\/strong> offers precise vacuum control and automated readings, ensuring compliance with Annex B.<\/p>\n<hr class=\"\" data-start=\"2231\" data-end=\"2234\" \/>\n<h3 class=\"\" data-start=\"2236\" data-end=\"2303\">2. Hypodermic Syringe Liquid Leak Test Under Compression (Annex D)<\/h3>\n<p class=\"\" data-start=\"2305\" data-end=\"2418\">Il <strong data-start=\"2309\" data-end=\"2348\">hypodermic syringe liquid leak test<\/strong> examines syringe integrity under axial and lateral mechanical stress.<\/p>\n<ul data-start=\"2420\" data-end=\"2647\">\n<li class=\"\" data-start=\"2420\" data-end=\"2565\">\n<p class=\"\" data-start=\"2422\" data-end=\"2565\"><strong data-start=\"2422\" data-end=\"2433\">Method:<\/strong> After sealing the nozzle, a side force is applied to deflect the plunger, followed by axial compression to simulate user operation.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2566\" data-end=\"2647\">\n<p class=\"\" data-start=\"2568\" data-end=\"2647\"><strong data-start=\"2568\" data-end=\"2584\">Observation:<\/strong> Monitor for fluid leakage at pressures of 200 kPa and 300 kPa.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"2649\" data-end=\"2835\"><strong data-start=\"2649\" data-end=\"2675\">Attrezzatura consigliata:<\/strong><br data-start=\"2675\" data-end=\"2678\" \/>Use <strong data-start=\"2682\" data-end=\"2728\">SPPT-01 <a href=\"https:\/\/www.qualitester.com\/it\/prodotto-2\/syringe-liquid-leakage-tester\/\">Syringe Positive Pressure Tightness Tester<\/a><\/strong>\u00a0from Cell Instruments to apply controlled mechanical forces and monitor for any failure in seal integrity.<\/p>\n<hr class=\"\" data-start=\"2837\" data-end=\"2840\" \/>\n<h3 data-start=\"2842\" data-end=\"2907\">3. Syringe Dead Space Test: Minimizing Medication Waste (Annex C)<\/h3>\n<p class=\"\" data-start=\"2909\" data-end=\"3067\">Dead space refers to the volume of fluid that remains in the syringe after complete expulsion. High dead space can lead to drug wastage and inaccurate dosing.<\/p>\n<ul data-start=\"3069\" data-end=\"3238\">\n<li class=\"\" data-start=\"3069\" data-end=\"3162\">\n<p class=\"\" data-start=\"3071\" data-end=\"3162\"><strong data-start=\"3071\" data-end=\"3082\">Method:<\/strong> Weigh the empty syringe, then weigh it after being filled and emptied of water.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3163\" data-end=\"3238\">\n<p class=\"\" data-start=\"3165\" data-end=\"3238\"><strong data-start=\"3165\" data-end=\"3181\">Calcolo:<\/strong> The difference in weight indicates <strong data-start=\"3217\" data-end=\"3231\">dead space<\/strong> in mL.<\/p>\n<\/li>\n<\/ul>\n<hr class=\"\" data-start=\"3437\" data-end=\"3440\" \/>\n<h3 data-start=\"3442\" data-end=\"3490\">4. Glide Force Test for Syringe Piston (Annex E)<img decoding=\"async\" class=\"wp-image-6652 alignright\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-E.webp\" alt=\"ISO 7886-1 Annex E\" width=\"272\" height=\"358\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-E.webp 546w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-E-228x300.webp 228w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/05\/ISO-7886-1-Annex-E-9x12.webp 9w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/><\/h3>\n<p class=\"\" data-start=\"3492\" data-end=\"3683\">Smooth piston movement is critical for user comfort and precise dosage control. The <strong data-start=\"3576\" data-end=\"3596\">glide force test<\/strong> measures the force required to operate the piston consistently across the full stroke.<\/p>\n<ul data-start=\"3685\" data-end=\"3873\">\n<li class=\"\" data-start=\"3685\" data-end=\"3798\">\n<p class=\"\" data-start=\"3687\" data-end=\"3798\"><strong data-start=\"3687\" data-end=\"3698\">Method:<\/strong> A mechanical testing machine depresses the plunger at a fixed rate, recording real-time resistance.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3799\" data-end=\"3873\">\n<p class=\"\" data-start=\"3801\" data-end=\"3873\"><strong data-start=\"3801\" data-end=\"3813\">Purpose:<\/strong> Verifies the syringe usability and consistency across lots.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"3875\" data-end=\"4084\"><strong data-start=\"3875\" data-end=\"3901\">Attrezzatura consigliata:<\/strong><br data-start=\"3901\" data-end=\"3904\" \/><strong data-start=\"3904\" data-end=\"3958\">Cell Instruments MST-01 <a href=\"https:\/\/www.qualitester.com\/it\/prodotto-2\/sale-syringe-plunger-glide-force-tester\/\">Medical Syringe Tester<\/a><\/strong>\u00a0is ideal for <strong data-start=\"3972\" data-end=\"3992\">glide force test<\/strong> applications. It records force profiles and complies with ISO 7886-1 accuracy requirements.<\/p>\n<hr class=\"\" data-start=\"4086\" data-end=\"4089\" \/>\n<h2 class=\"\" data-start=\"4091\" data-end=\"4143\">Why Choose Cell Instruments for ISO 7886 Testing?<\/h2>\n<p class=\"\" data-start=\"4145\" data-end=\"4312\">Cell Instruments offers a complete suite of syringe testing solutions to help manufacturers meet and exceed <strong data-start=\"4253\" data-end=\"4267\">ISO 7886-1<\/strong> requirements. Our equipment is designed for:<\/p>\n<ul data-start=\"4313\" data-end=\"4476\">\n<li class=\"\" data-start=\"4313\" data-end=\"4344\">\n<p class=\"\" data-start=\"4315\" data-end=\"4344\">High precision and automation<\/p>\n<\/li>\n<li class=\"\" data-start=\"4345\" data-end=\"4386\">\n<p class=\"\" data-start=\"4347\" data-end=\"4386\">Compliance with international standards<\/p>\n<\/li>\n<li class=\"\" data-start=\"4387\" data-end=\"4422\">\n<p class=\"\" data-start=\"4389\" data-end=\"4422\">Easy operation and data recording<\/p>\n<\/li>\n<li class=\"\" data-start=\"4423\" data-end=\"4476\">\n<p class=\"\" data-start=\"4425\" data-end=\"4476\">Flexible customization to meet specific test setups<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"4478\" data-end=\"4682\">Whether you&#8217;re validating product design or managing batch release testing, <strong data-start=\"4554\" data-end=\"4564\">SLT-01<\/strong>, <strong data-start=\"4566\" data-end=\"4577\">SPPT-01<\/strong>, e <strong data-start=\"4583\" data-end=\"4593\">MST-01<\/strong> deliver reliable and repeatable results tailored to the medical device industry&#8217;s needs.<\/p>\n<hr class=\"\" data-start=\"4684\" data-end=\"4687\" \/>\n<p class=\"\" data-start=\"4704\" data-end=\"5183\">Achieving compliance with <a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\"><strong data-start=\"4730\" data-end=\"4744\">ISO 7886-1<\/strong><\/a> is not just a regulatory hurdle\u2014it\u2019s a commitment to quality and patient safety. By understanding and implementing essential tests like the <strong data-start=\"4885\" data-end=\"4912\">hypodermic syringe test<\/strong>, <strong data-start=\"4914\" data-end=\"4927\">test di tenuta<\/strong>, <strong data-start=\"4929\" data-end=\"4956\">syringe dead space test<\/strong>, e <strong data-start=\"4962\" data-end=\"4982\">glide force test<\/strong>, manufacturers can confidently release products to the market. Equip your lab with Cell Instruments\u2019 advanced testers to streamline testing and ensure accuracy across all stages of syringe production.<\/p>\n<p class=\"\" data-start=\"5185\" data-end=\"5296\"><strong data-start=\"5185\" data-end=\"5296\">For technical consultations, instrument selection, or customized solutions, contact Cell Instruments today.<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>Test sulle siringhe ipodermiche ISO 7886-1 Lo standard ISO 7886-1 definisce i requisiti di prestazione e sicurezza per le siringhe ipodermiche monouso, sottolineando aspetti quali la resistenza alle perdite, lo spazio morto e la forza di scorrimento. I produttori e i team di garanzia della qualit\u00e0 devono comprendere le procedure di test delineate dalla norma ISO 7886-1 per garantire la conformit\u00e0 del prodotto e la sicurezza del paziente. ISO 7886-1 ...<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/it\/standards\/iso-7886-1\/\"> <span class=\"screen-reader-text\">ISO 7886-1<\/span> Leggi altro \u00bb<\/a><\/p>","protected":false},"author":4,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-6648","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/pages\/6648","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/comments?post=6648"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/pages\/6648\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/it\/wp-json\/wp\/v2\/media?parent=6648"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}