{"id":6640,"date":"2025-05-07T10:25:05","date_gmt":"2025-05-07T02:25:05","guid":{"rendered":"https:\/\/www.qualitester.com\/?post_type=product&#038;p=6640"},"modified":"2025-05-07T10:25:05","modified_gmt":"2025-05-07T02:25:05","slug":"syringe-piston-glide-force-tester","status":"publish","type":"product","link":"https:\/\/www.qualitester.com\/hu\/termek\/syringe-piston-glide-force-tester\/","title":{"rendered":"SSR-01 fecskend\u0151 cs\u00fasz\u00f3 ellen\u00e1ll\u00e1s teszter"},"content":{"rendered":"<h2 data-start=\"378\" data-end=\"1083\">The Importance of Glide Force in Syringe Performance<\/h2>\n<p class=\"\" data-start=\"378\" data-end=\"1083\">In syringe manufacturing and quality control, <em data-start=\"497\" data-end=\"510\">glide force<\/em> plays a pivotal role in determining how smoothly and consistently a syringe\u2019s piston moves during drug administration. It directly impacts usability, patient comfort, and dosing accuracy. This article introduces the <strong data-start=\"727\" data-end=\"764\">Syringe Piston Glide Force Tester<\/strong>, a specialized instrument designed to quantify this crucial parameter in accordance with <strong data-start=\"854\" data-end=\"876\">ISO 7886-1 Annex E<\/strong>. We will delve into its testing method, technical capabilities, and how it supports compliance with <strong data-start=\"977\" data-end=\"997\"><a href=\"https:\/\/www.qualitester.com\/hu\/standards\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\">ISO 7886<\/a> tesztel\u00e9s<\/strong> requirements\u2014essential for syringe manufacturers and quality assurance professionals.<\/p>\n<hr class=\"\" data-start=\"1085\" data-end=\"1088\" \/>\n<h2 data-start=\"1090\" data-end=\"1367\">Syringe Piston Glide Force Tester and ISO 7886 Testing Explained<\/h2>\n<p class=\"\" data-start=\"1090\" data-end=\"1367\">A <strong data-start=\"1165\" data-end=\"1202\">Syringe Piston Glide Force Tester<\/strong>\u2014also referred to as the <strong data-start=\"1227\" data-end=\"1271\">SSR-01 fecskend\u0151 cs\u00fasz\u00f3 ellen\u00e1ll\u00e1s teszter<\/strong>\u2014is designed to perform precision tests on hypodermic syringes. Its core function is to measure:<\/p>\n<ul data-start=\"1369\" data-end=\"1537\">\n<li class=\"\" data-start=\"1369\" data-end=\"1431\">\n<p class=\"\" data-start=\"1371\" data-end=\"1431\">A <strong data-start=\"1375\" data-end=\"1395\">initiating force<\/strong> required to start piston movement<\/p>\n<\/li>\n<li class=\"\" data-start=\"1432\" data-end=\"1481\">\n<p class=\"\" data-start=\"1434\" data-end=\"1481\">A <strong data-start=\"1438\" data-end=\"1452\">mean force<\/strong> during continuous movement<\/p>\n<\/li>\n<li class=\"\" data-start=\"1482\" data-end=\"1537\">\n<p class=\"\" data-start=\"1484\" data-end=\"1537\">A <strong data-start=\"1488\" data-end=\"1505\">maximum force<\/strong> encountered throughout the test<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"1539\" data-end=\"1878\">These parameters are central to the glide force profile outlined in <strong data-start=\"1607\" data-end=\"1629\">ISO 7886-1 Annex E<\/strong>, the international standard governing manual-use sterile hypodermic syringes. Annex E details the method for evaluating how much resistance a piston presents when fluid is expelled at a constant rate, using distilled water and a standardized setup.<\/p>\n<p class=\"\" data-start=\"1880\" data-end=\"2117\">By aligning with ISO 7886, manufacturers can ensure that their products meet global safety and performance expectations. This is critical for sterile medical devices intended for widespread use in hospitals, clinics, and home healthcare.<\/p>\n<hr class=\"\" data-start=\"2119\" data-end=\"2122\" \/>\n<h2 data-start=\"2124\" data-end=\"2358\">How Glide Force is Measured: ISO 7886-1 Annex E Procedure<\/h2>\n<p class=\"\" data-start=\"2124\" data-end=\"2358\">To determine the glide force accurately, the <strong data-start=\"2233\" data-end=\"2277\">SSR-01 Syringe Piston Glide Force Tester<\/strong> uses the procedure prescribed in <strong data-start=\"2311\" data-end=\"2333\">ISO 7886-1 Annex E<\/strong>. The core steps include:<\/p>\n<ul data-start=\"2360\" data-end=\"2688\">\n<li class=\"\" data-start=\"2360\" data-end=\"2438\">\n<p class=\"\" data-start=\"2362\" data-end=\"2438\">Filling the syringe with <strong data-start=\"2387\" data-end=\"2406\">distilled water<\/strong> to beyond its nominal capacity.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2439\" data-end=\"2547\">\n<p class=\"\" data-start=\"2441\" data-end=\"2547\">Mounting it to the test fixture while aligning the reservoir\u2019s water level to the syringe barrel midpoint.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2548\" data-end=\"2591\">\n<p class=\"\" data-start=\"2550\" data-end=\"2591\">Setting the <strong data-start=\"2562\" data-end=\"2590\">test speed at 100 mm\/min<\/strong>.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2592\" data-end=\"2688\">\n<p class=\"\" data-start=\"2594\" data-end=\"2688\">Activating the mechanical drive to depress the piston while continuously recording force data.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"2690\" data-end=\"2710\">The system captures:<\/p>\n<ul data-start=\"2712\" data-end=\"2929\">\n<li class=\"\" data-start=\"2712\" data-end=\"2784\">\n<p class=\"\" data-start=\"2714\" data-end=\"2784\"><strong data-start=\"2714\" data-end=\"2740\">Initiating force (fs):<\/strong> the force needed to start plunger movement.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2785\" data-end=\"2855\">\n<p class=\"\" data-start=\"2787\" data-end=\"2855\"><strong data-start=\"2787\" data-end=\"2812\">Mean glide force (F):<\/strong> average force throughout plunger movement.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2856\" data-end=\"2929\">\n<p class=\"\" data-start=\"2858\" data-end=\"2929\"><strong data-start=\"2858\" data-end=\"2883\">Maximum force (Fmax):<\/strong> the peak force required during piston travel.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"2931\" data-end=\"3036\">This standardized process ensures precise repeatability and data integrity for quality control reporting.<\/p>\n<hr class=\"\" data-start=\"3038\" data-end=\"3041\" \/>\n<h2 data-start=\"3043\" data-end=\"3268\">Key Features of SSR-01 Syringe Sliding Resistance Tester<\/h2>\n<p class=\"\" data-start=\"3043\" data-end=\"3268\">Cell Instruments\u2019 <strong data-start=\"3124\" data-end=\"3134\">SSR-01<\/strong> model brings automation, reliability, and high-resolution data to syringe glide force testing. Some of its standout features include:<\/p>\n<ul data-start=\"3270\" data-end=\"3842\">\n<li class=\"\" data-start=\"3270\" data-end=\"3340\">\n<p class=\"\" data-start=\"3272\" data-end=\"3340\"><strong data-start=\"3272\" data-end=\"3290\">High Accuracy:<\/strong> \u00b10.5% full-scale reading for force measurements<\/p>\n<\/li>\n<li class=\"\" data-start=\"3341\" data-end=\"3420\">\n<p class=\"\" data-start=\"3343\" data-end=\"3420\"><strong data-start=\"3343\" data-end=\"3371\">User-Friendly Interface:<\/strong> 7-inch HMI touchscreen with intuitive controls<\/p>\n<\/li>\n<li class=\"\" data-start=\"3421\" data-end=\"3502\">\n<p class=\"\" data-start=\"3423\" data-end=\"3502\"><strong data-start=\"3423\" data-end=\"3450\">Precision Drive System:<\/strong> Ball lead screw mechanism and variable test speed<\/p>\n<\/li>\n<li class=\"\" data-start=\"3503\" data-end=\"3595\">\n<p class=\"\" data-start=\"3505\" data-end=\"3595\"><strong data-start=\"3505\" data-end=\"3526\">Data Rich Output:<\/strong> Simultaneous capture of initiating, mean, and maximum glide forces<\/p>\n<\/li>\n<li class=\"\" data-start=\"3596\" data-end=\"3673\">\n<p class=\"\" data-start=\"3598\" data-end=\"3673\"><strong data-start=\"3598\" data-end=\"3624\">Customizable Fixtures:<\/strong> Adaptable to different syringe types and sizes<\/p>\n<\/li>\n<li class=\"\" data-start=\"3674\" data-end=\"3733\">\n<p class=\"\" data-start=\"3676\" data-end=\"3733\"><strong data-start=\"3676\" data-end=\"3700\">Overload Protection:<\/strong> Enhances safety during testing<\/p>\n<\/li>\n<li class=\"\" data-start=\"3734\" data-end=\"3842\">\n<p class=\"\" data-start=\"3736\" data-end=\"3842\"><strong data-start=\"3736\" data-end=\"3763\">Auto Return &amp; Printing:<\/strong> Returns to start position and prints test results with a built-in microprinter<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"3844\" data-end=\"3975\">These capabilities not only simplify compliance with <strong data-start=\"3897\" data-end=\"3911\">ISO 7886-1<\/strong> but also optimize workflow efficiency and reduce manual errors.<\/p>\n<hr class=\"\" data-start=\"3977\" data-end=\"3980\" \/>\n<h2 data-start=\"3982\" data-end=\"4120\">Applications Across Multiple Industries<\/h2>\n<p class=\"\" data-start=\"3982\" data-end=\"4120\">Glide force testing is essential in multiple sectors where syringes are critical components:<\/p>\n<ul data-start=\"4122\" data-end=\"4446\">\n<li class=\"\" data-start=\"4122\" data-end=\"4205\">\n<p class=\"\" data-start=\"4124\" data-end=\"4205\"><strong data-start=\"4124\" data-end=\"4157\">Medical device manufacturing:<\/strong> Ensures smooth performance and patient safety<\/p>\n<\/li>\n<li class=\"\" data-start=\"4206\" data-end=\"4275\">\n<p class=\"\" data-start=\"4208\" data-end=\"4275\"><strong data-start=\"4208\" data-end=\"4237\">Pharmaceutical packaging:<\/strong> Verifies proper delivery mechanisms<\/p>\n<\/li>\n<li class=\"\" data-start=\"4276\" data-end=\"4365\">\n<p class=\"\" data-start=\"4278\" data-end=\"4365\"><strong data-start=\"4278\" data-end=\"4314\">Regulatory testing laboratories:<\/strong> Confirms conformity with international standards<\/p>\n<\/li>\n<li class=\"\" data-start=\"4366\" data-end=\"4446\">\n<p class=\"\" data-start=\"4368\" data-end=\"4446\"><strong data-start=\"4368\" data-end=\"4394\">Quality control units:<\/strong> Identifies defective syringes early in production<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"4448\" data-end=\"4583\">With applications spanning hospitals, laboratories, and industrial production lines, the SSR-01 proves its versatility and reliability.<\/p>\n<hr class=\"\" data-start=\"4585\" data-end=\"4588\" \/>\n<h2 data-start=\"4590\" data-end=\"5050\">Why Choose Cell Instruments\u2019 SSR-01 for Glide Force Testing?<\/h2>\n<p class=\"\" data-start=\"4590\" data-end=\"5050\">Cell Instruments has extensive experience in <strong data-start=\"4702\" data-end=\"4736\">material and packaging testing<\/strong> and offers full customization to meet specialized testing requirements. The SSR-01 represents our commitment to <strong data-start=\"4849\" data-end=\"4909\">innovation, quality assurance, and regulatory compliance<\/strong>. By choosing our solution, syringe manufacturers gain a reliable partner to support ISO 7886-1 adherence and continuous product improvement.<\/p>\n<p class=\"\" data-start=\"5057\" data-end=\"5513\">Understanding and controlling <em data-start=\"5104\" data-end=\"5117\">glide force<\/em> is not just about meeting standards\u2014it\u2019s about delivering quality and safety to end-users. With Cell Instruments\u2019 <strong data-start=\"5232\" data-end=\"5269\">Syringe Piston Glide Force Tester<\/strong>, compliance with <strong data-start=\"5287\" data-end=\"5309\"><a href=\"https:\/\/www.iso.org\/standard\/64790.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 7886-1<\/a> Annex E<\/strong> becomes both straightforward and reliable. Whether you&#8217;re in pharmaceutical production, medical device QA, or laboratory validation, the <strong data-start=\"5447\" data-end=\"5457\">SSR-01<\/strong> is your solution for precision, consistency, and trust.<\/p>\n<hr class=\"\" data-start=\"5515\" data-end=\"5518\" \/>\n<h2 data-start=\"5520\" data-end=\"5530\">GYIK<\/h2>\n<p class=\"\" data-start=\"5532\" data-end=\"5765\"><strong data-start=\"5532\" data-end=\"5603\">1. What is glide force, and why is it important in syringe testing?<\/strong><br data-start=\"5603\" data-end=\"5606\" \/>Glide force is the resistance encountered when moving the syringe piston. It&#8217;s critical for ensuring smooth medication delivery and preventing user discomfort.<\/p>\n<p class=\"\" data-start=\"5962\" data-end=\"6133\"><strong data-start=\"5962\" data-end=\"6018\">2. What forces are measured using the SSR-01 tester?<\/strong><br data-start=\"6018\" data-end=\"6021\" \/>The SSR-01 measures the <strong data-start=\"6045\" data-end=\"6065\">initiating force<\/strong>, <strong data-start=\"6067\" data-end=\"6087\">mean<\/strong>, \u00e9s <strong data-start=\"6093\" data-end=\"6116\">maximum glide force<\/strong> during the test.<\/p>\n<p class=\"\" data-start=\"6135\" data-end=\"6287\"><strong data-start=\"6135\" data-end=\"6190\">3. Can the SSR-01 test syringes of different sizes?<\/strong><br data-start=\"6190\" data-end=\"6193\" \/>Yes, the system includes multiple fixtures that accommodate various syringe sizes and volumes.<\/p>\n<p class=\"\" data-start=\"6289\" data-end=\"6506\"><strong data-start=\"6289\" data-end=\"6351\">4. How does Cell Instruments support custom testing needs?<\/strong><br data-start=\"6351\" data-end=\"6354\" \/>We provide <strong data-start=\"6365\" data-end=\"6442\">custom fixture development, automation upgrades, and software integration<\/strong> to meet specific client requirements across diverse industries.<\/p>","protected":false},"excerpt":{"rendered":"<p>The Importance of Glide Force in Syringe Performance In syringe manufacturing and quality control, glide force plays a pivotal role in determining how smoothly and consistently a syringe\u2019s piston moves during drug administration. It directly impacts usability, patient comfort, and dosing accuracy. This article introduces the Syringe Piston Glide Force Tester, a specialized instrument designed &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/hu\/termek\/syringe-piston-glide-force-tester\/\"> <span class=\"screen-reader-text\">SSR-01 fecskend\u0151 cs\u00fasz\u00f3 ellen\u00e1ll\u00e1s teszter<\/span> Olvass tov\u00e1bb \"<\/a><\/p>","protected":false},"featured_media":6642,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":""},"product_cat":[1053,934,149],"product_tag":[],"class_list":{"0":"post-6640","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-iso-7886-1","7":"product_cat-medical-packaging-tester","8":"product_cat-pharma-and-medical-testers","9":"desktop-align-left","10":"tablet-align-left","11":"mobile-align-left","13":"first","14":"instock","15":"shipping-taxable","16":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/product\/6640","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/comments?post=6640"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/product\/6640\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/media\/6642"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/media?parent=6640"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/product_cat?post=6640"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/product_tag?post=6640"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}