{"id":7100,"date":"2025-07-21T10:05:32","date_gmt":"2025-07-21T02:05:32","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7100"},"modified":"2025-07-23T13:48:05","modified_gmt":"2025-07-23T05:48:05","slug":"iso-12048","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/hu\/standards\/iso-12048\/","title":{"rendered":"ISO 12048"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"509\" data-end=\"574\"><strong data-start=\"509\" data-end=\"572\">ISO 12048<\/strong><\/h1>\n<h1 style=\"text-align: center;\" data-start=\"509\" data-end=\"574\"><strong data-start=\"509\" data-end=\"572\">Csomagok nyom\u00e1s\u00e1ll\u00f3s\u00e1gi vizsg\u00e1lata<\/strong><\/h1>\n<h2 data-start=\"576\" data-end=\"968\">Bevezet\u00e9s<\/h2>\n<p data-start=\"576\" data-end=\"968\">Az ISO 12048 egy sz\u00e9les k\u00f6rben elismert nemzetk\u00f6zi szabv\u00e1ny, amely meghat\u00e1rozza a <em data-start=\"729\" data-end=\"767\">t\u00f6m\u00f6r\u00edt\u00e9si \u00e9s egym\u00e1sra rak\u00e1si teljes\u00edtm\u00e9ny<\/em> a teljes, megt\u00f6lt\u00f6tt sz\u00e1ll\u00edt\u00e1si csomagokb\u00f3l. Ez fontos szerepet j\u00e1tszik <strong data-start=\"819\" data-end=\"869\">d\u00f6nt\u0151 szerepet j\u00e1tszik a csomagol\u00e1s tart\u00f3ss\u00e1g\u00e1nak \u00e9rt\u00e9kel\u00e9s\u00e9ben<\/strong>, k\u00fcl\u00f6n\u00f6sen a t\u00f6r\u00e9keny vagy \u00e9rz\u00e9keny \u00e1ruk eset\u00e9ben, ide\u00e9rtve <strong data-start=\"925\" data-end=\"942\">inf\u00fazi\u00f3s zs\u00e1kok<\/strong> orvosi k\u00f6rnyezetben haszn\u00e1lj\u00e1k.<\/p>\n<p data-start=\"970\" data-end=\"1348\">Mivel a term\u00e9kbiztons\u00e1gi \u00e9s megfelel\u0151s\u00e9gi k\u00f6vetelm\u00e9nyek egyre szigor\u00fabb\u00e1 v\u00e1lnak, k\u00fcl\u00f6n\u00f6sen a <strong data-start=\"1040\" data-end=\"1080\">eg\u00e9szs\u00e9g\u00fcgyi \u00e9s gy\u00f3gyszeripari logisztika<\/strong>, az ISO 12048 szabv\u00e1ny egy\u00e9rtelm\u0171 m\u00f3dszertant k\u00edn\u00e1l annak \u00e9rt\u00e9kel\u00e9s\u00e9re, hogy egy csomag k\u00e9pes-e ellen\u00e1llni a t\u00e1rol\u00e1s \u00e9s a sz\u00e1ll\u00edt\u00e1s sor\u00e1n fell\u00e9p\u0151 mechanikai nyom\u00e1soknak. Ez a szabv\u00e1ny sz\u00e1mos vizsg\u00e1lati elj\u00e1r\u00e1s alapj\u00e1t k\u00e9pezi, t\u00f6bbek k\u00f6z\u00f6tt <strong data-start=\"1270\" data-end=\"1298\">csomag-nyom\u00e1spr\u00f3ba<\/strong>, amely a val\u00f3s k\u00f6r\u00fclm\u00e9nyek k\u00f6z\u00f6tt fell\u00e9p\u0151 ig\u00e9nybev\u00e9telek szimul\u00e1l\u00e1s\u00e1nak egyik legfontosabb m\u00f3dszere.<\/p>\n<hr data-start=\"1350\" data-end=\"1353\" \/>\n<h2 data-start=\"1355\" data-end=\"1432\"><strong data-start=\"1355\" data-end=\"1430\">Mi\u00e9rt fontos a csomagol\u00e1s t\u00f6m\u00f6rs\u00e9gi vizsg\u00e1lata a csomagol\u00e1s tart\u00f3ss\u00e1g\u00e1nak \u00e9rt\u00e9kel\u00e9s\u00e9ben?<\/strong><\/h2>\n<p data-start=\"1434\" data-end=\"1769\">A <strong data-start=\"1438\" data-end=\"1466\">csomag-nyom\u00e1spr\u00f3ba<\/strong>, az ISO 12048 szabv\u00e1ny alapj\u00e1n, szimul\u00e1lja azokat a f\u00fcgg\u0151leges r\u00e9tegez\u00e9si er\u0151ket, amelyeknek egy csomag a rakt\u00e1roz\u00e1s \u00e9s a sz\u00e1ll\u00edt\u00e1s sor\u00e1n ki lehet t\u00e9ve. K\u00f6rnyezeti el\u0151k\u00e9sz\u00edt\u00e9ssel (23\u00b12 \u2103, 50\u00b15% relat\u00edv p\u00e1ratartalom, legal\u00e1bb 24 \u00f3r\u00e1n \u00e1t) kombin\u00e1lva ez a vizsg\u00e1lat \u00e9rt\u00e9kes inform\u00e1ci\u00f3kat ny\u00fajthat mind a <strong data-start=\"1713\" data-end=\"1737\">szerkezeti integrit\u00e1s<\/strong> \u00e9s <strong data-start=\"1742\" data-end=\"1768\">m\u0171k\u00f6d\u00e9si megb\u00edzhat\u00f3s\u00e1g<\/strong>.<\/p>\n<p data-start=\"1771\" data-end=\"2067\">Az olyan nagy \u00e9rt\u00e9k\u0171 \u00e1gazatok, mint p\u00e9ld\u00e1ul <strong data-start=\"1798\" data-end=\"1844\">gy\u00f3gyszerek, \u00e9lelmiszerek \u00e9s orvostechnikai eszk\u00f6z\u00f6k<\/strong> a szennyez\u0151d\u00e9s \u00e9s a mechanikai meghib\u00e1sod\u00e1s elleni v\u00e9delmet a csomagol\u00e1sra b\u00edzz\u00e1k. A <strong data-start=\"1924\" data-end=\"1959\">a csomagol\u00e1s tart\u00f3ss\u00e1g\u00e1nak \u00e9rt\u00e9kel\u00e9se<\/strong> seg\u00edt biztos\u00edtani, hogy a term\u00e9k sterilit\u00e1sa \u00e9s haszn\u00e1lhat\u00f3s\u00e1ga a gy\u00e1rt\u00e1st\u00f3l a betegell\u00e1t\u00e1si helyre t\u00f6rt\u00e9n\u0151 kisz\u00e1ll\u00edt\u00e1sig v\u00e1ltozatlan maradjon.<\/p>\n<p data-start=\"2069\" data-end=\"2103\">A leggyakrabban m\u00e9rt mutat\u00f3k a k\u00f6vetkez\u0151k:<\/p>\n<ul data-start=\"2104\" data-end=\"2342\">\n<li data-start=\"2104\" data-end=\"2166\">\n<p data-start=\"2106\" data-end=\"2166\">A deform\u00e1ci\u00f3 kezdeti pontja (a szerkezet k\u00e1rosod\u00e1s\u00e1nak kezdete)<\/p>\n<\/li>\n<li data-start=\"2167\" data-end=\"2222\">\n<p data-start=\"2169\" data-end=\"2222\">Teljes t\u00f6r\u00e9spont (maxim\u00e1lis ellen\u00e1ll\u00e1si k\u00fcsz\u00f6b)<\/p>\n<\/li>\n<li data-start=\"2223\" data-end=\"2296\">\n<p data-start=\"2225\" data-end=\"2296\">Deform\u00e1ci\u00f3s hat\u00e1r\u00e9rt\u00e9kek (pl. magass\u00e1gcs\u00f6kken\u00e9s \u226410%, illetve inf\u00fazi\u00f3s zs\u00e1kok eset\u00e9ben \u22645%)<\/p>\n<\/li>\n<li data-start=\"2297\" data-end=\"2342\">\n<p data-start=\"2299\" data-end=\"2342\">M\u0171k\u00f6d\u00e9si hib\u00e1k (t\u00f6m\u00edt\u00e9sreped\u00e9s, sziv\u00e1rg\u00e1s)<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2344\" data-end=\"2666\"><a href=\"https:\/\/www.qualitester.com\/hu\/applications\/package-testing-equipment\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"2344\" data-end=\"2373\">A Cell Instruments PCT-01 modellje <\/strong><\/a>az ISO 12048 szabv\u00e1nynak megfelel\u0151, rendk\u00edv\u00fcl pontos eredm\u00e9nyeket biztos\u00edt. A \u00b10,5%-en bel\u00fcli er\u0151m\u00e9r\u00e9si hiba \u00e9s a \u22640,05%-es nyom\u00f3lemez-p\u00e1rhuzamoss\u00e1gi elt\u00e9r\u00e9s r\u00e9v\u00e9n garant\u00e1lja az egyenletes terhel\u00e9seloszl\u00e1st. Ezenk\u00edv\u00fcl t\u00e1mogatja az 5 mm\/perc alatti cs\u00f6kkentett terhel\u00e9si sebess\u00e9geket is olyan t\u00f6r\u00e9keny anyagok eset\u00e9ben, mint p\u00e9ld\u00e1ul a puha f\u00f3li\u00e1b\u00f3l k\u00e9sz\u00fclt inf\u00fazi\u00f3s tasakok.<\/p>\n<hr data-start=\"2668\" data-end=\"2671\" \/>\n<h2 data-start=\"2673\" data-end=\"2737\"><strong data-start=\"2673\" data-end=\"2735\">Inf\u00fazi\u00f3s zs\u00e1kok nyom\u00e1spr\u00f3b\u00e1ja: az ISO 12048 szabv\u00e1ny egyik speci\u00e1lis esete<\/strong><\/h2>\n<p data-start=\"2739\" data-end=\"3121\">A <strong data-start=\"2743\" data-end=\"2776\">inf\u00fazi\u00f3s zs\u00e1k nyom\u00e1spr\u00f3ba<\/strong> a csomagol\u00e1s-nyom\u00e1s\u00e1ll\u00f3s\u00e1gi vizsg\u00e1latok egy speci\u00e1lis r\u00e9szter\u00fclete. Az orvosi min\u0151s\u00e9g\u0171 f\u00f3lia puha \u00e9s rugalmas jellege miatt az ilyen csomagol\u00e1sok k\u00fcl\u00f6n\u00f6sen hajlamosak a deform\u00e1l\u00f3d\u00e1sra \u00e9s a szakad\u00e1sra. Az ISO 12048 szabv\u00e1ny megb\u00edzhat\u00f3 vizsg\u00e1lati keretrendszert biztos\u00edt, \u00e9s sok esetben integr\u00e1lva van a <strong data-start=\"3047\" data-end=\"3062\">YY\/T 0681.3<\/strong>, amely a steril g\u00e1tl\u00f3 rendszerek sziv\u00e1rg\u00e1svizsg\u00e1lat\u00e1ra \u00f6sszpontos\u00edt.<\/p>\n<p>&nbsp;<\/p>\n<p data-start=\"3123\" data-end=\"3158\">A tesztel\u00e9s fontos szempontjai a k\u00f6vetkez\u0151k:<\/p>\n<ul data-start=\"3159\" data-end=\"3335\">\n<li data-start=\"3159\" data-end=\"3202\">\n<p data-start=\"3161\" data-end=\"3202\">Magass\u00e1gcs\u00f6kken\u00e9si hat\u00e1r\u00e9rt\u00e9kek (\u22645% puha csomagok eset\u00e9ben)<\/p>\n<\/li>\n<li data-start=\"3203\" data-end=\"3250\">\n<p data-start=\"3205\" data-end=\"3250\">A t\u00f6m\u00edt\u00e9s \u00e9ps\u00e9g\u00e9nek \u00e9s a folyad\u00e9k sziv\u00e1rg\u00e1s\u00e1nak \u00e9rt\u00e9kel\u00e9se<\/p>\n<\/li>\n<li data-start=\"3251\" data-end=\"3294\">\n<p data-start=\"3253\" data-end=\"3294\">Az alkalmaz\u00e1st 5 mm\/percn\u00e9l kisebb sebess\u00e9ggel kell bet\u00f6lteni<\/p>\n<\/li>\n<li data-start=\"3295\" data-end=\"3335\">\n<p data-start=\"3297\" data-end=\"3335\">Az ISO 7500-1 szabv\u00e1nynak val\u00f3 megfelel\u00e9s a kalibr\u00e1l\u00e1s ter\u00e9n<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3337\" data-end=\"3606\">PIT-01P-k <strong data-start=\"3347\" data-end=\"3378\">alacsony fordulatsz\u00e1m\u00fa prec\u00edzi\u00f3s vez\u00e9rl\u00e9s<\/strong> \u00e9s <strong data-start=\"3383\" data-end=\"3405\">lapos nyom\u00f3lemez-kialak\u00edt\u00e1s<\/strong> (Ra \u2264 3,2 \u03bcm) \u00e9rt\u00e9ke miatt ide\u00e1lis ilyen \u00e9rz\u00e9keny alkalmaz\u00e1sokhoz. A vizsg\u00e1lati eredm\u00e9nyeket a k\u00f6vetkez\u0151 form\u00e1ban adja ki: <strong data-start=\"3494\" data-end=\"3524\">nyom\u00e1s\u2013deform\u00e1ci\u00f3 g\u00f6rbe<\/strong> kiemelve a legfontosabb meghib\u00e1sod\u00e1si m\u00f3dokat, bele\u00e9rtve a tartalom kisziv\u00e1rg\u00e1s\u00e1t vagy a szerkezet \u00f6sszeoml\u00e1s\u00e1t.<\/p>\n<hr data-start=\"3608\" data-end=\"3611\" \/>\n<h2 data-start=\"3613\" data-end=\"3679\"><strong data-start=\"3613\" data-end=\"3677\">Vizsg\u00e1lati m\u00f3dszertan \u00e9s jelent\u00e9sk\u00e9sz\u00edt\u00e9s: az ISO 12048 szabv\u00e1ny el\u0151\u00edr\u00e1sainak megfelel\u0151en<\/strong><\/h2>\n<p data-start=\"3681\" data-end=\"3710\"><strong data-start=\"3681\" data-end=\"3708\">Nyom\u00e1spr\u00f3ba-m\u00f3dszer:<\/strong><\/p>\n<ol data-start=\"3711\" data-end=\"4135\">\n<li data-start=\"3711\" data-end=\"3830\">\n<p data-start=\"3714\" data-end=\"3830\"><strong data-start=\"3714\" data-end=\"3737\">Minta kondicion\u00e1l\u00e1s<\/strong>: A mint\u00e1kat legal\u00e1bb 24 \u00f3r\u00e1n \u00e1t szab\u00e1lyozott k\u00f6r\u00fclm\u00e9nyek k\u00f6z\u00f6tt (23 \u00b0C \u00b12 \/ 50% relat\u00edv p\u00e1ratartalom \u00b15) kell t\u00e1rolni.<\/p>\n<\/li>\n<li data-start=\"3831\" data-end=\"3945\">\n<p data-start=\"3834\" data-end=\"3945\"><strong data-start=\"3834\" data-end=\"3852\">Bet\u00f6lt\u00e9si m\u00f3dszer<\/strong>: A terhel\u00e9st f\u00fcgg\u0151legesen, \u00e1lland\u00f3 sebess\u00e9ggel kell alkalmazni (10 \u00b13 mm\/perc; \u00e9rz\u00e9keny anyagok eset\u00e9n lassabban).<\/p>\n<\/li>\n<li data-start=\"3946\" data-end=\"4019\">\n<p data-start=\"3949\" data-end=\"4019\"><strong data-start=\"3949\" data-end=\"3965\">Adatgy\u0171jt\u00e9s<\/strong>: Figyelj\u00fck meg \u00e9s r\u00f6gz\u00edts\u00fck a nyom\u00e1s\u2013deform\u00e1ci\u00f3 g\u00f6rb\u00e9t.<\/p>\n<\/li>\n<li data-start=\"4020\" data-end=\"4135\">\n<p data-start=\"4023\" data-end=\"4135\"><strong data-start=\"4023\" data-end=\"4046\">\u00c9rt\u00e9kel\u00e9si krit\u00e9riumok<\/strong>: Jel\u00f6lje meg a kezdeti deform\u00e1ci\u00f3t \u00e9s a t\u00f6r\u00e9spontot, majd ellen\u0151rizze, hogy nincsenek-e m\u0171k\u00f6d\u00e9si probl\u00e9m\u00e1k, p\u00e9ld\u00e1ul sziv\u00e1rg\u00e1s.<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"4137\" data-end=\"4246\"><strong data-start=\"4137\" data-end=\"4163\">Jelent\u00e9st\u00e9teli k\u00f6vetelm\u00e9nyek:<\/strong><br \/>\nAz ISO 12048 szabv\u00e1nynak \u00e9s az ipar\u00e1gi bev\u00e1lt gyakorlatoknak megfelel\u0151en a jelent\u00e9snek a k\u00f6vetkez\u0151ket kell tartalmaznia:<\/p>\n<ul data-start=\"4247\" data-end=\"4429\">\n<li data-start=\"4247\" data-end=\"4275\" data-wp-editing=\"1\"><span style=\"font-size: 16px;\">A tesztk\u00f6rnyezet r\u00e9szletei<\/span><\/li>\n<li data-start=\"4276\" data-end=\"4293\">\n<p data-start=\"4278\" data-end=\"4293\">Bet\u00f6lt\u00e9si sebess\u00e9g<\/p>\n<\/li>\n<li data-start=\"4294\" data-end=\"4314\">\n<p data-start=\"4296\" data-end=\"4314\">A lemez m\u00e9retei<\/p>\n<\/li>\n<li data-start=\"4315\" data-end=\"4341\">\n<p data-start=\"4317\" data-end=\"4341\">Deform\u00e1ci\u00f3s k\u00fcsz\u00f6b\u00e9rt\u00e9kek<\/p>\n<\/li>\n<li data-start=\"4342\" data-end=\"4385\">\n<p data-start=\"4344\" data-end=\"4385\">A meghib\u00e1sod\u00e1s t\u00edpusa (szerkezeti vagy m\u0171k\u00f6d\u00e9si)<\/p>\n<\/li>\n<li data-start=\"4386\" data-end=\"4429\">\n<p data-start=\"4388\" data-end=\"4429\"><strong data-start=\"4388\" data-end=\"4429\">A t\u00f6m\u00f6r\u00edt\u00e9si g\u00f6rbe grafikus \u00e1br\u00e1zol\u00e1sa<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4431\" data-end=\"4557\">A Cell Instruments PCT-01 k\u00e9sz\u00fcl\u00e9ke t\u00e1mogatja <strong data-start=\"4466\" data-end=\"4515\">automatiz\u00e1lt adatgy\u0171jt\u00e9s \u00e9s grafikus elemz\u00e9s<\/strong>, biztos\u00edtva ezzel a szab\u00e1lyoknak val\u00f3 megfelel\u00e9st \u00e9s a reproduk\u00e1lhat\u00f3s\u00e1got.<\/p>\n<hr data-start=\"4559\" data-end=\"4562\" \/>\n<h2 data-start=\"4564\" data-end=\"4626\"><strong data-start=\"4564\" data-end=\"4624\">A csomagol\u00e1s tart\u00f3ss\u00e1g\u00e1nak jav\u00edt\u00e1sa az ISO 12048 szerinti vizsg\u00e1latokkal<\/strong><\/h2>\n<p data-start=\"4628\" data-end=\"4945\">Olyan versenyk\u00e9pes \u00e1gazatokban, mint <strong data-start=\"4656\" data-end=\"4715\">elektronika, italok, h\u00e1ztart\u00e1si vegyszerek \u00e9s eg\u00e9szs\u00e9g\u00fcgy<\/strong>, a csomagol\u00e1si hiba nem csup\u00e1n apr\u00f3 probl\u00e9ma \u2014 szennyez\u0151d\u00e9shez, anyagi vesztes\u00e9ghez vagy a betegek eg\u00e9szs\u00e9g\u00e9t vesz\u00e9lyeztet\u0151 kock\u00e1zathoz vezethet. <strong data-start=\"4825\" data-end=\"4856\">ISO 12048 szabv\u00e1nynak megfelel\u0151 vizsg\u00e1lat<\/strong>, \u2026teh\u00e1t nem csup\u00e1n egy szab\u00e1lyoz\u00e1si k\u00f6vetelm\u00e9ny, hanem a min\u0151s\u00e9gbiztos\u00edt\u00e1s strat\u00e9giai eszk\u00f6ze.<\/p>\n<p data-start=\"4947\" data-end=\"5149\">Ak\u00e1r egy \u00faj <strong data-start=\"4980\" data-end=\"5003\">kartonv\u00e1z<\/strong>, elemz\u00e9s\u00e9vel <strong data-start=\"5015\" data-end=\"5044\">a t\u00f6bbr\u00e9teg\u0171 f\u00f3lia viselked\u00e9se<\/strong>, vagy egy <strong data-start=\"5062\" data-end=\"5086\">orvosi inf\u00fazi\u00f3s zs\u00e1k<\/strong>, az ISO 12048 szabv\u00e1ny betart\u00e1sa hozz\u00e1j\u00e1rul a csomagol\u00e1s megb\u00edzhat\u00f3s\u00e1g\u00e1nak n\u00f6vel\u00e9s\u00e9hez.<\/p>\n<p data-start=\"5151\" data-end=\"5347\">Azoknak az \u00fcgyfeleknek, akiknek sz\u00fcks\u00e9g\u00fck van <strong data-start=\"5173\" data-end=\"5200\">egyedi tesztfejleszt\u00e9s<\/strong> vagy <strong data-start=\"5204\" data-end=\"5233\">automatiz\u00e1l\u00e1si \u00e1talakul\u00e1s<\/strong>, A Cell Instruments a PIT-01P-n alapul\u00f3, testre szabott megold\u00e1sokat \u00e9s prec\u00edzi\u00f3s tesztel\u00e9si platformok sz\u00e9les v\u00e1laszt\u00e9k\u00e1t k\u00edn\u00e1lja.<\/p>\n<hr data-start=\"5349\" data-end=\"5352\" \/>\n<h2 data-start=\"5354\" data-end=\"5700\"><strong data-start=\"5354\" data-end=\"5368\">K\u00f6vetkeztet\u00e9s<\/strong><\/h2>\n<p data-start=\"5354\" data-end=\"5700\"><br data-start=\"5368\" data-end=\"5371\" \/>Az\u00e1ltal, hogy a csomagol\u00e1s \u00e9rt\u00e9kel\u00e9s\u00e9t az ISO 12048 szabv\u00e1nyra alapozz\u00e1k, a gy\u00e1rt\u00f3k biztos\u00edthatj\u00e1k, hogy term\u00e9keik megfeleljenek a nyom\u00e1s\u00e1ll\u00f3s\u00e1gra \u00e9s a tart\u00f3ss\u00e1gra vonatkoz\u00f3 glob\u00e1lis szabv\u00e1nyoknak. Olyan ter\u00fcleteken, mint <strong data-start=\"5543\" data-end=\"5576\">inf\u00fazi\u00f3s zs\u00e1k nyom\u00e1spr\u00f3ba<\/strong> vagy <strong data-start=\"5580\" data-end=\"5615\">a csomagol\u00e1s tart\u00f3ss\u00e1g\u00e1nak \u00e9rt\u00e9kel\u00e9se<\/strong>, a szab\u00e1lyok betart\u00e1sa nemcsak a term\u00e9k v\u00e9delm\u00e9t garant\u00e1lja, hanem a v\u00e1s\u00e1rl\u00f3k bizalm\u00e1t is er\u0151s\u00edti.<\/p>\n<p data-start=\"5702\" data-end=\"5917\">Ha megb\u00edzhat\u00f3, az ISO-szabv\u00e1nyoknak megfelel\u0151 tesztel\u00e9si megold\u00e1sokat keres, akkor a <strong data-start=\"5753\" data-end=\"5781\"><a href=\"https:\/\/www.celtec.cn\" target=\"_blank\" rel=\"noopener nofollow\">Cell Instruments<\/a><a href=\"https:\/\/www.qualitester.com\/hu\/applications\/package-testing-equipment\/\" target=\"_blank\" rel=\"noopener\"> PCT-01 <\/a><\/strong>\u00a0kiemelkedik \u2013 pontoss\u00e1got, rugalmass\u00e1got \u00e9s professzion\u00e1lis szint\u0171 t\u00e1mogat\u00e1st ny\u00fajt azoknak az ipar\u00e1gaknak, amelyek nem el\u00e9gednek meg kevesebbel, mint a kiv\u00e1l\u00f3s\u00e1g.<\/p>\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"PCT-01 kett\u0151s \u00fcreg\u0171 csomagol\u00e1s-nyom\u00e1svizsg\u00e1l\u00f3 \u2013 Folyad\u00e9klev\u00e1laszt\u00f3 zs\u00e1k nyom\u00e1s\u00e1ll\u00f3s\u00e1ga\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/Zcv0ejzEkW0?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 12048 Package Compression Testing Introduction ISO 12048 is a widely recognized international standard that specifies test methods for the compression and stacking performance of complete, filled transport packages. It plays a crucial role in assessing packaging durability, particularly for fragile or critical goods, including infusion bags used in medical settings. As product safety and &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/hu\/standards\/iso-12048\/\"> <span class=\"screen-reader-text\">ISO 12048<\/span> Olvass tov\u00e1bb \"<\/a><\/p>","protected":false},"author":3,"featured_media":7119,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7100","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/pages\/7100","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/comments?post=7100"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/pages\/7100\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/pages\/4948"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/media\/7119"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/hu\/wp-json\/wp\/v2\/media?parent=7100"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}