{"id":7938,"date":"2026-04-22T16:36:11","date_gmt":"2026-04-22T08:36:11","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7938"},"modified":"2026-04-22T16:37:10","modified_gmt":"2026-04-22T08:37:10","slug":"astm-d2732","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/fr\/standards\/astm-d2732\/","title":{"rendered":"ASTM D2732"},"content":{"rendered":"<p data-start=\"5813\" data-end=\"6401\">L'ASTM D2732 fournit une m\u00e9thode normalis\u00e9e pour mesurer le retrait thermique sans contrainte des films plastiques en immergeant les sp\u00e9cimens dans un milieu chauff\u00e9 contr\u00f4l\u00e9. Le test quantifie les changements dimensionnels dans les directions m\u00e9canique et transversale, r\u00e9v\u00e9lant le comportement des contraintes internes et les caract\u00e9ristiques du traitement. Une ex\u00e9cution pr\u00e9cise n\u00e9cessite une temp\u00e9rature contr\u00f4l\u00e9e, une dur\u00e9e et des conditions sans contrainte, g\u00e9n\u00e9ralement obtenues \u00e0 l'aide d'un testeur de r\u00e9traction de film. Cette m\u00e9thode permet de comparer les mat\u00e9riaux, d'optimiser les processus et de contr\u00f4ler la qualit\u00e9 dans les domaines de l'emballage, de la m\u00e9decine et de l'industrie.<\/p>\n<h2 data-section-id=\"4pxvza\" data-start=\"492\" data-end=\"532\">Qu'est-ce que l'ASTM D2732 et pourquoi est-elle importante ?<\/h2>\n<p data-start=\"534\" data-end=\"843\"><strong data-start=\"534\" data-end=\"548\">ASTM D2732<\/strong> d\u00e9finit une approche standardis\u00e9e pour \u00e9valuer les <strong data-start=\"597\" data-end=\"638\">retrait thermique lin\u00e9aire non contraint<\/strong> des films et feuilles plastiques d'une \u00e9paisseur \u22640,76 mm. Cette m\u00e9thode aide les ing\u00e9nieurs et les \u00e9quipes de contr\u00f4le de la qualit\u00e9 \u00e0 quantifier le comportement des films lorsqu'ils sont expos\u00e9s \u00e0 des temp\u00e9ratures \u00e9lev\u00e9es sans contraintes m\u00e9caniques.<\/p>\n<p data-start=\"845\" data-end=\"1036\">Lors de la production de films, des processus tels que l'extrusion et l'orientation introduisent de l'humidit\u00e9 dans le film. <strong data-start=\"923\" data-end=\"944\">contraintes internes<\/strong>. Sous l'effet de la chaleur, ces contraintes se rel\u00e2chent, ce qui provoque un retrait. L'ASTM D2732 vous permet de :<\/p>\n<ul data-start=\"1038\" data-end=\"1258\">\n<li data-section-id=\"11tgcs5\" data-start=\"1038\" data-end=\"1098\"><strong data-start=\"1040\" data-end=\"1098\">Quantifier le pourcentage de r\u00e9tr\u00e9cissement \u00e0 des temp\u00e9ratures sp\u00e9cifiques<\/strong><\/li>\n<li data-section-id=\"1ucr8f6\" data-start=\"1099\" data-end=\"1150\">Comprendre <strong data-start=\"1112\" data-end=\"1150\">le comportement de stress induit par la transformation<\/strong><\/li>\n<li data-section-id=\"1awnhim\" data-start=\"1151\" data-end=\"1213\">Comparer les mat\u00e9riaux entre eux <strong data-start=\"1178\" data-end=\"1213\">diff\u00e9rentes conditions de production<\/strong><\/li>\n<li data-section-id=\"w0sk05\" data-start=\"1214\" data-end=\"1258\">Garantir <strong data-start=\"1223\" data-end=\"1258\">coh\u00e9rence des performances au niveau de l'utilisation finale<\/strong><\/li>\n<\/ul>\n<p data-start=\"1260\" data-end=\"1416\">L'ASTM D2732 est donc tr\u00e8s utile dans les industries o\u00f9 la stabilit\u00e9 dimensionnelle a un impact direct sur l'int\u00e9grit\u00e9 du produit, comme l'emballage et les mat\u00e9riaux m\u00e9dicaux.<\/p>\n<h2 data-section-id=\"1wvkf60\" data-start=\"1423\" data-end=\"1473\">M\u00e9thode d'essai de r\u00e9traction et testeur de r\u00e9traction de film<\/h2>\n<h3 data-section-id=\"az5naf\" data-start=\"1475\" data-end=\"1523\">Principes fondamentaux de la m\u00e9thode d'essai de r\u00e9traction<\/h3>\n<p data-start=\"1525\" data-end=\"1729\">Le <strong data-start=\"1529\" data-end=\"1554\">m\u00e9thode d'essai de r\u00e9tr\u00e9cissement<\/strong> d\u00e9crit dans la norme ASTM D2732 \u00e9value la fa\u00e7on dont un film se contracte lorsqu'il est immerg\u00e9 dans un fluide chauff\u00e9. Le test permet de s'assurer que <strong data-start=\"1666\" data-end=\"1691\">pas de contrainte ext\u00e9rieure<\/strong>, ce qui permet un comportement de r\u00e9tr\u00e9cissement naturel.<\/p>\n<p data-start=\"1731\" data-end=\"1765\">Les principaux points de proc\u00e9dure sont les suivants :<\/p>\n<ul data-start=\"1767\" data-end=\"1976\">\n<li data-section-id=\"yy7m96\" data-start=\"1767\" data-end=\"1803\">Taille de l'\u00e9chantillon : <strong data-start=\"1784\" data-end=\"1803\">100 mm \u00d7 100 mm<\/strong><\/li>\n<li data-section-id=\"bejdp2\" data-start=\"1804\" data-end=\"1846\">Minimum : <strong data-start=\"1815\" data-end=\"1846\">deux \u00e9chantillons par temp\u00e9rature<\/strong><\/li>\n<li data-section-id=\"wekmg4\" data-start=\"1847\" data-end=\"1893\">Dur\u00e9e d'immersion : typiquement <strong data-start=\"1879\" data-end=\"1893\">10 secondes<\/strong><\/li>\n<li data-section-id=\"1tcxhof\" data-start=\"1894\" data-end=\"1976\">Directives de mesure :\n<ul data-start=\"1922\" data-end=\"1976\">\n<li data-section-id=\"1szsrts\" data-start=\"1922\" data-end=\"1946\">Direction de la machine (MD)<\/li>\n<li data-section-id=\"37bj75\" data-start=\"1949\" data-end=\"1976\">Direction transversale (TD)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p data-start=\"1978\" data-end=\"2146\">Le test utilise un <strong data-start=\"1994\" data-end=\"2025\">bain \u00e0 temp\u00e9rature contr\u00f4l\u00e9e<\/strong>, Les \u00e9chantillons sont ensuite refroidis rapidement et mesur\u00e9s pour d\u00e9terminer le changement de dimensions. Apr\u00e8s avoir \u00e9t\u00e9 chauff\u00e9s, les \u00e9chantillons sont refroidis rapidement et mesur\u00e9s pour d\u00e9terminer les changements dimensionnels.<\/p>\n<h3 data-section-id=\"12n5odv\" data-start=\"2148\" data-end=\"2183\">R\u00f4le d'un testeur de r\u00e9traction de film<\/h3>\n<p data-start=\"2185\" data-end=\"2295\">Un professionnel <strong data-start=\"2200\" data-end=\"2225\">testeur de r\u00e9tr\u00e9cissement de film<\/strong> garantit la r\u00e9p\u00e9tabilit\u00e9 et la pr\u00e9cision en contr\u00f4lant les variables critiques :<\/p>\n<ul data-start=\"2297\" data-end=\"2413\">\n<li data-section-id=\"t6acap\" data-start=\"2297\" data-end=\"2324\"><strong data-start=\"2299\" data-end=\"2324\">Stabilit\u00e9 de la temp\u00e9rature<\/strong><\/li>\n<li data-section-id=\"w4s8ig\" data-start=\"2325\" data-end=\"2345\"><strong data-start=\"2327\" data-end=\"2345\">Dur\u00e9e d'immersion<\/strong><\/li>\n<li data-section-id=\"1pq9qku\" data-start=\"2346\" data-end=\"2377\"><strong data-start=\"2348\" data-end=\"2377\">Distribution uniforme de la chaleur<\/strong><\/li>\n<li data-section-id=\"rkvg5i\" data-start=\"2378\" data-end=\"2413\"><strong data-start=\"2380\" data-end=\"2413\">Conservation de l'\u00e9chantillon sans contrainte<\/strong><\/li>\n<\/ul>\n<p data-start=\"2415\" data-end=\"2498\">Par exemple, le <strong data-start=\"2432\" data-end=\"2466\">Testeur de r\u00e9traction sans film FST-01<\/strong> de Cell Instruments fournit :<\/p>\n<ul data-start=\"2500\" data-end=\"2647\">\n<li data-section-id=\"15r0wly\" data-start=\"2500\" data-end=\"2538\">Contr\u00f4le pr\u00e9cis de la temp\u00e9rature (\u00b10,3\u00b0C)<\/li>\n<li data-section-id=\"1993y2p\" data-start=\"2539\" data-end=\"2565\">Chauffage uniforme par bain d'huile<\/li>\n<li data-section-id=\"31wen9\" data-start=\"2566\" data-end=\"2599\">Support standardis\u00e9 \u00e0 r\u00e9traction libre<\/li>\n<li data-section-id=\"1kkpvhx\" data-start=\"2600\" data-end=\"2647\">Minutage automatis\u00e9 pour des p\u00e9riodes d'attente coh\u00e9rentes<\/li>\n<\/ul>\n<p data-start=\"2649\" data-end=\"2797\">Ce type de syst\u00e8me r\u00e9duit la variabilit\u00e9 de l'op\u00e9rateur et garantit la conformit\u00e9 aux exigences de la norme ASTM D2732, en particulier dans les environnements de contr\u00f4le qualit\u00e9 \u00e0 haut d\u00e9bit.<\/p>\n<h2 data-section-id=\"1xx1u9e\" data-start=\"2804\" data-end=\"2852\">Aper\u00e7u \u00e9tape par \u00e9tape de la proc\u00e9dure ASTM D2732<\/h2>\n<h3 data-section-id=\"1ug6n21\" data-start=\"2854\" data-end=\"2876\">Pr\u00e9paration des \u00e9chantillons<\/h3>\n<ul data-start=\"2878\" data-end=\"2996\">\n<li data-section-id=\"brgikf\" data-start=\"2878\" data-end=\"2916\">Couper les sp\u00e9cimens en <strong data-start=\"2897\" data-end=\"2916\">100 mm \u00d7 100 mm<\/strong><\/li>\n<li data-section-id=\"1g4dwfw\" data-start=\"2917\" data-end=\"2943\">Mark orientation (MD\/TD)<\/li>\n<li data-section-id=\"1rl990v\" data-start=\"2944\" data-end=\"2996\">\u00c9viter d'introduire des contraintes m\u00e9caniques lors de la coupe<\/li>\n<\/ul>\n<h3 data-section-id=\"1ssswpn\" data-start=\"2998\" data-end=\"3017\">Processus de test<\/h3>\n<ol data-start=\"3019\" data-end=\"3266\">\n<li data-section-id=\"1kohjw\" data-start=\"3019\" data-end=\"3066\">Pr\u00e9chauffer le bain \u00e0 la temp\u00e9rature cible<\/li>\n<li data-section-id=\"71hptq\" data-start=\"3067\" data-end=\"3118\">Placer l'\u00e9chantillon dans un <strong data-start=\"3094\" data-end=\"3116\">porte-r\u00e9tr\u00e9cissement gratuit<\/strong><\/li>\n<li data-section-id=\"g2vhlw\" data-start=\"3119\" data-end=\"3160\">Immerger l'\u00e9chantillon pendant ~10 secondes<\/li>\n<li data-section-id=\"mdgqwl\" data-start=\"3161\" data-end=\"3216\">Retirer et refroidir imm\u00e9diatement dans un liquide compatible.<\/li>\n<li data-section-id=\"18ohwgy\" data-start=\"3217\" data-end=\"3266\">Mesurer les dimensions finales apr\u00e8s stabilisation<\/li>\n<\/ol>\n<p data-start=\"3268\" data-end=\"3356\"><strong data-start=\"3268\" data-end=\"3282\">Important :<\/strong> \u00c9vitez de pr\u00e9chauffer ou d'\u00e9tirer l'\u00e9chantillon, car cela peut fausser les r\u00e9sultats.<\/p>\n<h2 data-section-id=\"ubu0ln\" data-start=\"3363\" data-end=\"3406\">Calcul et interpr\u00e9tation de la r\u00e9traction<\/h2>\n<p data-start=\"3408\" data-end=\"3453\">Le pourcentage de r\u00e9tr\u00e9cissement est calcul\u00e9 \u00e0 l'aide de la formule suivante<\/p>\n<p data-start=\"3455\" data-end=\"3492\"><span class=\"inline-block align-middle\"><span class=\"katex\"><span class=\"katex-mathml\">Retrait (%)=Lo-LfLo\u00d7100\\text{Retrait (\\%)} = \\frac{L_o - L_f}{L_o} \\Nfois 100<\/span><span class=\"katex-html\" aria-hidden=\"true\"><span class=\"base\"><span class=\"mord text\"><span class=\"mord\">R\u00e9tr\u00e9cissement (%)<\/span><\/span><span class=\"mrel\">=<\/span><\/span><span class=\"base\"><span class=\"mord\"><span class=\"mfrac\"><span class=\"vlist-t vlist-t2\"><span class=\"vlist-r\"><span class=\"vlist\"><span class=\"sizing reset-size6 size3 mtight\"><span class=\"mord mtight\"><span class=\"mord mathnormal mtight\">L<\/span><span class=\"msupsub\"><span class=\"sizing reset-size3 size1 mtight\"><span class=\"mord mathnormal mtight\">o<\/span><\/span><span class=\"vlist-s\">\u200b<\/span><\/span><\/span><\/span><span class=\"sizing reset-size6 size3 mtight\"><span class=\"mord mtight\"><span class=\"mord mathnormal mtight\">L<\/span><span class=\"msupsub\"><span class=\"sizing reset-size3 size1 mtight\"><span class=\"mord mathnormal mtight\">o<\/span><\/span><span class=\"vlist-s\">\u200b<\/span><\/span><span class=\"mbin mtight\">\u2212<\/span><span class=\"mord mathnormal mtight\">L<\/span><span class=\"msupsub\"><span class=\"sizing reset-size3 size1 mtight\"><span class=\"mord mathnormal mtight\">f<\/span><\/span><span class=\"vlist-s\">\u200b<\/span><\/span><\/span><\/span><\/span><span class=\"vlist-s\">\u200b<\/span><\/span><\/span><\/span><\/span><span class=\"mbin\">\u00d7<\/span><\/span><span class=\"base\"><span class=\"mord\">100<\/span><\/span><\/span><\/span><\/span><\/p>\n<p data-start=\"3494\" data-end=\"3500\">O\u00f9:<\/p>\n<ul data-start=\"3502\" data-end=\"3591\">\n<li data-section-id=\"6pfx3g\" data-start=\"3502\" data-end=\"3549\"><strong data-start=\"3504\" data-end=\"3510\">Lo<\/strong> = Longueur originale (typiquement 100 mm)<\/li>\n<li data-section-id=\"nvy54d\" data-start=\"3550\" data-end=\"3591\"><strong data-start=\"3552\" data-end=\"3558\">Lf<\/strong> = Longueur finale apr\u00e8s r\u00e9tr\u00e9cissement<\/li>\n<\/ul>\n<h3 data-section-id=\"zng66x\" data-start=\"3593\" data-end=\"3620\">Interpr\u00e9tation<\/h3>\n<ul data-start=\"3622\" data-end=\"3828\">\n<li data-section-id=\"2e7lah\" data-start=\"3622\" data-end=\"3680\"><strong data-start=\"3624\" data-end=\"3644\">R\u00e9tr\u00e9cissement plus important<\/strong> \u2192 une plus grande lib\u00e9ration du stress interne<\/li>\n<li data-section-id=\"1usnagp\" data-start=\"3681\" data-end=\"3758\"><strong data-start=\"3683\" data-end=\"3717\">Comportement en fonction de la temp\u00e9rature<\/strong> \u2192 indique les caract\u00e9ristiques de transformation<\/li>\n<li data-section-id=\"ljyaos\" data-start=\"3759\" data-end=\"3828\"><strong data-start=\"3761\" data-end=\"3799\">Diff\u00e9rences directionnelles (MD vs TD)<\/strong> \u2192 refl\u00e9ter l'orientation du film<\/li>\n<\/ul>\n<p data-start=\"3830\" data-end=\"3976\">Les tests effectu\u00e9s sur plusieurs temp\u00e9ratures permettent de cartographier les <strong data-start=\"3889\" data-end=\"3908\">courbe de r\u00e9tr\u00e9cissement<\/strong>, ce qui est essentiel pour la s\u00e9lection des mat\u00e9riaux et l'optimisation des processus.<\/p>\n<h2 data-section-id=\"b4nch9\" data-start=\"4483\" data-end=\"4526\">Choisir le bon testeur de r\u00e9traction de film<\/h2>\n<p><a href=\"https:\/\/www.qualitester.com\/fr\/produit\/film-free-shrink-tester-fst-01\/\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-7939 alignleft\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2026\/04\/ASTM-D2732-Film-Shrinkage-Test-Method-Tester-300x300.webp\" alt=\"ASTM D2732 Film Shrinkage Test Method &amp; Tester\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2026\/04\/ASTM-D2732-Film-Shrinkage-Test-Method-Tester-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2026\/04\/ASTM-D2732-Film-Shrinkage-Test-Method-Tester-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2026\/04\/ASTM-D2732-Film-Shrinkage-Test-Method-Tester-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2026\/04\/ASTM-D2732-Film-Shrinkage-Test-Method-Tester-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2026\/04\/ASTM-D2732-Film-Shrinkage-Test-Method-Tester.webp 600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p data-start=\"4528\" data-end=\"4581\">Lors de la s\u00e9lection d'un <a href=\"https:\/\/www.qualitester.com\/fr\/produit\/film-free-shrink-tester-fst-01\/\"><strong data-start=\"4545\" data-end=\"4570\">testeur de r\u00e9tr\u00e9cissement de film<\/strong><\/a>, consid\u00e9rer :<\/p>\n<ul data-start=\"4583\" data-end=\"4724\">\n<li data-section-id=\"1vstu0i\" data-start=\"4583\" data-end=\"4624\"><strong data-start=\"4585\" data-end=\"4624\">Pr\u00e9cision et uniformit\u00e9 de la temp\u00e9rature<\/strong><\/li>\n<li data-section-id=\"yd5al2\" data-start=\"4625\" data-end=\"4656\"><strong data-start=\"4627\" data-end=\"4656\">Facilit\u00e9 de manipulation des \u00e9chantillons<\/strong><\/li>\n<li data-section-id=\"1c47k7w\" data-start=\"4657\" data-end=\"4689\"><strong data-start=\"4659\" data-end=\"4689\">Conformit\u00e9 \u00e0 la norme ASTM D2732<\/strong><\/li>\n<li data-section-id=\"a7gq09\" data-start=\"4690\" data-end=\"4724\"><strong data-start=\"4692\" data-end=\"4724\">Automatisation et reproductibilit\u00e9<\/strong><\/li>\n<\/ul>\n<p data-start=\"4726\" data-end=\"4777\">Le <strong data-start=\"4730\" data-end=\"4757\">Cell Instruments FST-01<\/strong> se distingue par son :<\/p>\n<ul data-start=\"4779\" data-end=\"4921\">\n<li data-section-id=\"1149hgz\" data-start=\"4779\" data-end=\"4813\">Contr\u00f4le stable de la temp\u00e9rature par PID<\/li>\n<li data-section-id=\"5ygw1j\" data-start=\"4814\" data-end=\"4854\">Environnement homog\u00e8ne pour le chauffage des fluides<\/li>\n<li data-section-id=\"1h1cr5i\" data-start=\"4855\" data-end=\"4882\">Interface conviviale<\/li>\n<li data-section-id=\"1s25mwg\" data-start=\"4883\" data-end=\"4921\">R\u00e9p\u00e9tabilit\u00e9 fiable pour les laboratoires de contr\u00f4le de la qualit\u00e9<\/li>\n<\/ul>\n<p data-start=\"4923\" data-end=\"4990\">Il convient donc aussi bien \u00e0 la recherche et au d\u00e9veloppement qu'\u00e0 l'inspection de routine de la qualit\u00e9.<\/p>\n<p data-start=\"6416\" data-end=\"6858\">\u00c9valuez les performances de votre film avec une m\u00e9thode de test de r\u00e9tr\u00e9cissement fiable bas\u00e9e sur la norme ASTM D2732. En utilisant un testeur de r\u00e9traction de film de pr\u00e9cision comme le FST-01, vous pouvez mesurer la r\u00e9traction avec pr\u00e9cision dans des conditions thermiques contr\u00f4l\u00e9es, ce qui garantit une qualit\u00e9 de produit et une conformit\u00e9 constantes. Am\u00e9liorez votre s\u00e9lection de mat\u00e9riaux, r\u00e9duisez les risques de production et gagnez en confiance dans vos applications d'emballage ou de film industriel gr\u00e2ce \u00e0 des tests r\u00e9p\u00e9tables et bas\u00e9s sur des normes.<\/p>\n<h2 data-section-id=\"1qsfy1n\" data-start=\"4997\" data-end=\"5033\">FAQ<\/h2>\n<p data-section-id=\"jyw0jp\" data-start=\"5035\" data-end=\"5090\">1. Quels mat\u00e9riaux peuvent \u00eatre test\u00e9s \u00e0 l'aide de la norme ASTM D2732 ?<br \/>\nFilms et feuilles en plastique d'une \u00e9paisseur allant jusqu'\u00e0 0,76 mm, y compris PE, PET, PVC et lamin\u00e9s multicouches.<\/p>\n<p data-section-id=\"1n1ctqf\" data-start=\"5190\" data-end=\"5239\">2. Pourquoi le retrait non contraint est-il important ?<br \/>\nIl refl\u00e8te les caract\u00e9ristiques du mat\u00e9riau <strong data-start=\"5267\" data-end=\"5292\">r\u00e9ponse thermique r\u00e9elle<\/strong>, sans subir d'influence m\u00e9canique ext\u00e9rieure.<\/p>\n<p data-section-id=\"spsikp\" data-start=\"5336\" data-end=\"5384\">3. Combien de temp\u00e9ratures doivent \u00eatre test\u00e9es ?<br \/>\nLes essais \u00e0 plusieurs temp\u00e9ratures permettent de d\u00e9finir le <strong data-start=\"5435\" data-end=\"5465\">profil de r\u00e9tr\u00e9cissement complet<\/strong> de la mati\u00e8re.<\/p>\n<p data-section-id=\"2capjl\" data-start=\"5484\" data-end=\"5536\">4. Quelles sont les causes de la variation des r\u00e9sultats de r\u00e9tr\u00e9cissement ?<br \/>\nLes facteurs sont les suivants <strong data-start=\"5553\" data-end=\"5632\">l'orientation, l'\u00e9paisseur, la vitesse de chauffage et la distribution des contraintes internes du film<\/strong>.<\/p>\n<p data-section-id=\"9x0lys\" data-start=\"5635\" data-end=\"5687\">5. Peut <a href=\"https:\/\/store.astm.org\/d2732-14r25.html\" target=\"_blank\" rel=\"noopener nofollow\">ASTM D2732<\/a> \u00eatre utilis\u00e9 pour le contr\u00f4le de la qualit\u00e9 ?<br \/>\nOui. Il est largement utilis\u00e9 dans le cadre du contr\u00f4le de qualit\u00e9 pour s'assurer que <strong data-start=\"5727\" data-end=\"5783\">la coh\u00e9rence des lots et le respect des sp\u00e9cifications<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>ASTM D2732 provides a standardized method to measure the unrestrained thermal shrinkage of plastic films by immersing specimens in a controlled heated medium. The test quantifies dimensional changes in both machine and transverse directions, revealing internal stress behavior and processing characteristics. Accurate execution requires controlled temperature, timing, and non-restrained conditions, typically achieved using a film &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/fr\/standards\/astm-d2732\/\"> <span class=\"screen-reader-text\">ASTM D2732<\/span> Lire la suite \"<\/a><\/p>","protected":false},"author":4,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7938","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/fr\/wp-json\/wp\/v2\/pages\/7938","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/fr\/wp-json\/wp\/v2\/comments?post=7938"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/fr\/wp-json\/wp\/v2\/pages\/7938\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/fr\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/fr\/wp-json\/wp\/v2\/media?parent=7938"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}