{"id":6644,"date":"2025-05-07T11:30:19","date_gmt":"2025-05-07T03:30:19","guid":{"rendered":"https:\/\/www.qualitester.com\/?post_type=product&#038;p=6644"},"modified":"2025-05-07T11:30:19","modified_gmt":"2025-05-07T03:30:19","slug":"medical-needle-tubing-stiffness-tester","status":"publish","type":"product","link":"https:\/\/www.qualitester.com\/et\/toode\/medical-needle-tubing-stiffness-tester\/","title":{"rendered":"TS-01 toru j\u00e4ikuse tester"},"content":{"rendered":"<h2 data-start=\"393\" data-end=\"1063\">Introduction to Medical Needle Tubing Stiffness Tester<\/h2>\n<p class=\"\" data-start=\"393\" data-end=\"1063\">Ensuring the mechanical integrity of hypodermic needles is critical in the medical field. One essential property that influences performance, safety, and usability is <em data-start=\"621\" data-end=\"639\">tubing stiffness<\/em>. . <strong data-start=\"645\" data-end=\"687\">medical needle tubing stiffness tester<\/strong> provides a standardized, precise method to evaluate the stiffness of stainless steel tubing used in needle manufacturing. With the rise in global medical standards, especially compliance with <a href=\"https:\/\/www.qualitester.com\/et\/standards\/iso-9626\/\"><strong data-start=\"880\" data-end=\"892\">ISO 9626<\/strong><\/a> ja <strong data-start=\"897\" data-end=\"917\">ISO 9626 Annex B<\/strong>, reliable testing solutions have become indispensable for medical device manufacturers, quality control professionals, and research institutions.<\/p>\n<hr class=\"\" data-start=\"1065\" data-end=\"1068\" \/>\n<h2 data-start=\"1070\" data-end=\"1624\">Importance of Needle Tubing Stiffness in Medical Applications<\/h2>\n<p class=\"\" data-start=\"1070\" data-end=\"1624\">Stiffness directly affects a needle&#8217;s <strong data-start=\"1176\" data-end=\"1219\">insertion ability, structural integrity<\/strong>, ja <strong data-start=\"1225\" data-end=\"1241\">user control<\/strong>. A needle tube that is too soft may bend or break, risking patient injury or improper medication delivery. Conversely, an overly stiff needle may snap or cause unnecessary trauma during insertion. Therefore, achieving an optimal balance is essential. The <strong data-start=\"1497\" data-end=\"1539\">medical needle tubing stiffness tester<\/strong> plays a vital role in quantifying this balance and maintaining production standards.<\/p>\n<hr class=\"\" data-start=\"1626\" data-end=\"1629\" \/>\n<h2 data-start=\"1631\" data-end=\"1921\"><strong data-start=\"1631\" data-end=\"1697\">ISO 9626 Testing &#8211; <\/strong><strong data-start=\"1631\" data-end=\"1697\">ISO 9626 Annex B<\/strong><\/h2>\n<p class=\"\" data-start=\"1631\" data-end=\"1921\">The international standard <strong data-start=\"1727\" data-end=\"1744\">ISO 9626:2016<\/strong> outlines the mechanical and dimensional requirements for stainless steel tubing intended for hypodermic needles. <strong data-start=\"1858\" data-end=\"1869\">B lisa<\/strong> provides a specific method for measuring stiffness:<\/p>\n<ul data-start=\"1923\" data-end=\"2213\">\n<li class=\"\" data-start=\"1923\" data-end=\"2014\">\n<p class=\"\" data-start=\"1925\" data-end=\"2014\">A <strong data-start=\"1927\" data-end=\"1955\">known force (up to 60 N)<\/strong> is applied centrally to the tubing supported at both ends.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2015\" data-end=\"2085\">\n<p class=\"\" data-start=\"2017\" data-end=\"2085\">The resulting <strong data-start=\"2031\" data-end=\"2045\">deflection<\/strong> is measured with <strong data-start=\"2063\" data-end=\"2084\">0.01 mm precision<\/strong>.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2086\" data-end=\"2213\">\n<p class=\"\" data-start=\"2088\" data-end=\"2213\">The apparatus must include a blunt wedge-shaped <strong data-start=\"2136\" data-end=\"2147\">plunger<\/strong>, inclined at <strong data-start=\"2161\" data-end=\"2168\">60\u00b0<\/strong>, with a <strong data-start=\"2177\" data-end=\"2212\">1 mm radius cylindrical surface<\/strong>.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"2215\" data-end=\"2371\">The <strong data-start=\"2219\" data-end=\"2267\">TS-01 Medical Needle Tubing Stiffness Tester<\/strong> is designed specifically to fulfill this testing method, ensuring strict compliance with ISO standards.<\/p>\n<hr class=\"\" data-start=\"2373\" data-end=\"2376\" \/>\n<h2 data-start=\"2378\" data-end=\"2515\"><strong data-start=\"2378\" data-end=\"2418\">Test Principle and Working Mechanism<\/strong><\/h2>\n<p class=\"\" data-start=\"2378\" data-end=\"2515\">The <strong data-start=\"2425\" data-end=\"2467\">medical needle tubing stiffness tester<\/strong> operates on a simple yet effective principle:<\/p>\n<p class=\"\" data-start=\"2517\" data-end=\"2702\"><em data-start=\"2517\" data-end=\"2702\">A precise force is applied to the midpoint of the tubing, which is symmetrically supported. The instrument then records the vertical deflection, providing quantitative stiffness data.<\/em><\/p>\n<p class=\"\" data-start=\"2704\" data-end=\"2753\">The <strong data-start=\"2708\" data-end=\"2723\">TS-01 model<\/strong> by Cell Instruments features:<\/p>\n<ul data-start=\"2754\" data-end=\"3112\">\n<li class=\"\" data-start=\"2754\" data-end=\"2864\">\n<p class=\"\" data-start=\"2756\" data-end=\"2864\">A blunt wedge-shaped <strong data-start=\"2777\" data-end=\"2788\">plunger<\/strong> connected to a <strong data-start=\"2804\" data-end=\"2817\">load cell<\/strong>, ensuring high measurement accuracy (\u00b10.01 N).<\/p>\n<\/li>\n<li class=\"\" data-start=\"2865\" data-end=\"2930\">\n<p class=\"\" data-start=\"2867\" data-end=\"2930\">A movable crosshead powered by a <strong data-start=\"2900\" data-end=\"2929\">precision ball lead screw<\/strong>.<\/p>\n<\/li>\n<li class=\"\" data-start=\"2931\" data-end=\"3018\">\n<p class=\"\" data-start=\"2933\" data-end=\"3018\">A tubing holder (pan) that aligns the test sample accurately under the force plunger.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3019\" data-end=\"3112\">\n<p class=\"\" data-start=\"3021\" data-end=\"3112\">Variable <strong data-start=\"3030\" data-end=\"3044\">test speed<\/strong> (1\u2013500 mm\/min) to accommodate different tubing sizes and materials.<\/p>\n<\/li>\n<\/ul>\n<hr class=\"\" data-start=\"3114\" data-end=\"3117\" \/>\n<h2 data-start=\"3119\" data-end=\"3349\">Why Choose the TS-01 Medical Needle Tubing Stiffness Tester<\/h2>\n<p class=\"\" data-start=\"3119\" data-end=\"3349\">As a manufacturer of precision testing instruments, <strong data-start=\"3237\" data-end=\"3257\">Cell Instruments<\/strong> designed the <strong data-start=\"3271\" data-end=\"3280\">TS-01<\/strong> specifically for medical needle manufacturers. Key benefits include:<\/p>\n<ul data-start=\"3351\" data-end=\"3682\">\n<li class=\"\" data-start=\"3351\" data-end=\"3408\">\n<p class=\"\" data-start=\"3353\" data-end=\"3408\"><strong data-start=\"3353\" data-end=\"3407\">Full compliance with ISO 9626 and ISO 9626 Annex B<\/strong>.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3409\" data-end=\"3468\">\n<p class=\"\" data-start=\"3411\" data-end=\"3468\">High-resolution <strong data-start=\"3427\" data-end=\"3453\">deflection measurement<\/strong> up to 0.01 mm.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3469\" data-end=\"3549\">\n<p class=\"\" data-start=\"3471\" data-end=\"3549\">Robust design with <strong data-start=\"3490\" data-end=\"3513\">overload protection<\/strong> ja <strong data-start=\"3518\" data-end=\"3538\">automatic return<\/strong> functions.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3550\" data-end=\"3627\">\n<p class=\"\" data-start=\"3552\" data-end=\"3627\">User-friendly <strong data-start=\"3566\" data-end=\"3593\">7-inch touch screen HMI<\/strong> for test control and data review.<\/p>\n<\/li>\n<li class=\"\" data-start=\"3628\" data-end=\"3682\">\n<p class=\"\" data-start=\"3630\" data-end=\"3682\">Built-in <strong data-start=\"3639\" data-end=\"3655\">microprinter<\/strong> for instant report output.<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"3684\" data-end=\"3857\">These features not only streamline testing but also improve the <strong data-start=\"3748\" data-end=\"3794\">accuracy, repeatability, and documentation<\/strong> required for medical product validation and regulatory audits.<\/p>\n<hr class=\"\" data-start=\"3859\" data-end=\"3862\" \/>\n<h2 data-start=\"3864\" data-end=\"3996\">Applications Across Medical Manufacturing and Research<\/h2>\n<p class=\"\" data-start=\"3864\" data-end=\"3996\">The <strong data-start=\"3929\" data-end=\"3971\">medical needle tubing stiffness tester<\/strong> is widely applicable in:<\/p>\n<ul data-start=\"3997\" data-end=\"4271\">\n<li class=\"\" data-start=\"3997\" data-end=\"4038\">\n<p class=\"\" data-start=\"3999\" data-end=\"4038\">Hypodermic and pen needle manufacturing<\/p>\n<\/li>\n<li class=\"\" data-start=\"4039\" data-end=\"4097\">\n<p class=\"\" data-start=\"4041\" data-end=\"4097\">Quality control departments in medical device production<\/p>\n<\/li>\n<li class=\"\" data-start=\"4098\" data-end=\"4166\">\n<p class=\"\" data-start=\"4100\" data-end=\"4166\">Research and development labs working on innovative needle designs<\/p>\n<\/li>\n<li class=\"\" data-start=\"4167\" data-end=\"4218\">\n<p class=\"\" data-start=\"4169\" data-end=\"4218\">Regulatory testing agencies and inspection bodies<\/p>\n<\/li>\n<li class=\"\" data-start=\"4219\" data-end=\"4271\">\n<p class=\"\" data-start=\"4221\" data-end=\"4271\">OEMs and private-label medical component suppliers<\/p>\n<\/li>\n<\/ul>\n<p class=\"\" data-start=\"4273\" data-end=\"4388\">It provides critical mechanical data that ensures each needle tube performs reliably under clinical use conditions.<\/p>\n<hr class=\"\" data-start=\"4390\" data-end=\"4393\" \/>\n<h2 data-start=\"4395\" data-end=\"4437\">Technical Specifications at a Glance<\/h2>\n<div class=\"_tableContainer_16hzy_1\">\n<div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"4438\" data-end=\"4972\">\n<thead data-start=\"4438\" data-end=\"4503\">\n<tr data-start=\"4438\" data-end=\"4503\">\n<th data-start=\"4438\" data-end=\"4466\" data-col-size=\"sm\"><strong data-start=\"4440\" data-end=\"4453\">Parameeter<\/strong><\/th>\n<th data-start=\"4466\" data-end=\"4503\" data-col-size=\"sm\"><strong data-start=\"4468\" data-end=\"4485\">Spetsifikatsioon<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"4570\" data-end=\"4972\">\n<tr data-start=\"4570\" data-end=\"4635\">\n<td data-start=\"4570\" data-end=\"4598\" data-col-size=\"sm\">Maximum Test Force<\/td>\n<td data-col-size=\"sm\" data-start=\"4598\" data-end=\"4635\">60 N (customizable)<\/td>\n<\/tr>\n<tr data-start=\"4636\" data-end=\"4701\">\n<td data-start=\"4636\" data-end=\"4664\" data-col-size=\"sm\">Kiiruse vahemik<\/td>\n<td data-col-size=\"sm\" data-start=\"4664\" data-end=\"4701\">1\u2013500 mm\/min<\/td>\n<\/tr>\n<tr data-start=\"4702\" data-end=\"4767\">\n<td data-start=\"4702\" data-end=\"4730\" data-col-size=\"sm\">Measurement Accuracy<\/td>\n<td data-col-size=\"sm\" data-start=\"4730\" data-end=\"4767\">\u00b10.01 mm<\/td>\n<\/tr>\n<tr data-start=\"4768\" data-end=\"4833\">\n<td data-start=\"4768\" data-end=\"4796\" data-col-size=\"sm\">Toiteallikas<\/td>\n<td data-col-size=\"sm\" data-start=\"4796\" data-end=\"4833\">110~220V<\/td>\n<\/tr>\n<tr data-start=\"4834\" data-end=\"4899\">\n<td data-start=\"4834\" data-end=\"4862\" data-col-size=\"sm\">Control Interface<\/td>\n<td data-col-size=\"sm\" data-start=\"4862\" data-end=\"4899\">PLC with 7\u201d HMI touch screen<\/td>\n<\/tr>\n<tr data-start=\"4900\" data-end=\"4972\">\n<td data-start=\"4900\" data-end=\"4928\" data-col-size=\"sm\">Included Accessories<\/td>\n<td data-col-size=\"sm\" data-start=\"4928\" data-end=\"4972\">Plunger, tubing holder, power cord, fuse<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\">\n<div class=\"absolute end-0 flex items-end\"><span style=\"font-size: 16px;\">Stiffness testing is essential to guarantee the <\/span><strong style=\"font-size: 16px;\" data-start=\"5044\" data-end=\"5090\">mechanical reliability and clinical safety<\/strong><span style=\"font-size: 16px;\"> of hypodermic needles. By complying with <\/span><strong style=\"font-size: 16px;\" data-start=\"5132\" data-end=\"5152\"><a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 9626<\/a> testimine<\/strong><span style=\"font-size: 16px;\"> protocols, manufacturers can ensure that their tubing meets global performance standards. The <\/span><strong style=\"font-size: 16px;\" data-start=\"5247\" data-end=\"5295\">TS-01 medical needle tubing stiffness tester<\/strong><span style=\"font-size: 16px;\"> aadressilt <\/span><strong style=\"font-size: 16px;\" data-start=\"5301\" data-end=\"5321\">Cell Instruments<\/strong><span style=\"font-size: 16px;\"> offers a professional, precise, and easy-to-operate solution for stiffness measurement. Whether for compliance, R&amp;D, or quality assurance, TS-01 is the trusted choice for needle tubing evaluation.<\/span><\/div>\n<\/div>\n<\/div>\n<\/div>\n<hr class=\"\" data-start=\"5520\" data-end=\"5523\" \/>\n<h2 data-start=\"5525\" data-end=\"5572\">FAQ: Medical Needle Tubing Stiffness Tester<\/h2>\n<p class=\"\" data-start=\"5755\" data-end=\"5933\"><strong data-start=\"5755\" data-end=\"5829\">Q1: What type of needles or tubing can be tested with this instrument?<\/strong><br data-start=\"5829\" data-end=\"5832\" \/>A1: It is suitable for stainless steel needle tubing used in hypodermic, pen, or intravenous needles.<\/p>\n<p class=\"\" data-start=\"6096\" data-end=\"6253\"><strong data-start=\"6096\" data-end=\"6138\">Q2: Can I test different tubing sizes?<\/strong><br data-start=\"6138\" data-end=\"6141\" \/>A2: Yes, the tester includes adjustable fixtures and supports different spans as per ISO Table 2 specifications.<\/p>","protected":false},"excerpt":{"rendered":"<p>Sissejuhatus meditsiinilise n\u00f5elatoru j\u00e4ikuse testerisse Meditsiinivaldkonnas on h\u00fcpodermiliste n\u00f5elte mehaanilise terviklikkuse tagamine kriitilise t\u00e4htsusega. \u00dcks oluline omadus, mis m\u00f5jutab toimivust, ohutust ja kasutatavust, on torude j\u00e4ikus. Meditsiiniliste n\u00f5elatorude j\u00e4ikuse tester pakub standardiseeritud ja t\u00e4pset meetodit n\u00f5elte valmistamisel kasutatavate roostevabast terasest torude j\u00e4ikuse hindamiseks. ...<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/et\/toode\/medical-needle-tubing-stiffness-tester\/\"> <span class=\"screen-reader-text\">TS-01 toru j\u00e4ikuse tester<\/span> Loe edasi \u00bb<\/a><\/p>","protected":false},"featured_media":6646,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":""},"product_cat":[1180,845,934,149],"product_tag":[],"class_list":{"0":"post-6644","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-iso-9626","7":"product_cat-customization","8":"product_cat-medical-packaging-tester","9":"product_cat-pharma-and-medical-testers","10":"desktop-align-left","11":"tablet-align-left","12":"mobile-align-left","14":"first","15":"instock","16":"shipping-taxable","17":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/product\/6644","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/comments?post=6644"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/product\/6644\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/media\/6646"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/media?parent=6644"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/product_cat?post=6644"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/product_tag?post=6644"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}