{"id":3223,"date":"2023-08-07T08:52:04","date_gmt":"2023-08-07T00:52:04","guid":{"rendered":"https:\/\/www.qualitester.com\/?post_type=product&#038;p=3223"},"modified":"2024-12-04T16:01:26","modified_gmt":"2024-12-04T08:01:26","slug":"how-to-test-the-force-about-ampoule-breaking","status":"publish","type":"product","link":"https:\/\/www.qualitester.com\/et\/toode\/how-to-test-the-force-about-ampoule-breaking\/","title":{"rendered":"BST-01 Ampullide purunemise tester"},"content":{"rendered":"<h2><strong>Introduction to the Ampoule Break Force Tester<\/strong><\/h2>\n<p>The <strong>ampulli purunemise j\u00f5u tester<\/strong> on oluline vahend farmaatsia- ja meditsiinipakendit\u00f6\u00f6stuses, mis on m\u00f5eldud ampulli kaela murdmiseks vajaliku j\u00f5u m\u00f5\u00f5tmiseks. Ampullid on hermeetiliselt suletud mahutid, mida kasutatakse tundlike farmaatsiatoodete s\u00e4ilitamiseks. Kaela purunemistugevus m\u00e4ngib olulist rolli selles sisalduva toote ohutuse ja terviklikkuse tagamisel. T\u00e4pne ja usaldusv\u00e4\u00e4rne tester on oluline, et ampullid vastaksid ohutuks kasutamiseks ja k\u00e4sitsemiseks vajalikele standarditele.<\/p>\n<h2><strong>Understanding ISO 9187: Standard for Ampoule Break Force Testing<\/strong><\/h2>\n<p><a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noopener nofollow\">ISO 9187<\/a> is the international standard that specifies the method for testing the breaking force of ampoules. It provides detailed guidelines on how the testing process should be conducted, the necessary equipment, and the parameters to be measured to ensure consistent and accurate results. By following ISO 9187, manufacturers can be confident that their ampoules will meet safety requirements, reducing the risk of breakage during storage and handling.<\/p>\n<h3><strong>Test Method According to <a href=\"https:\/\/www.qualitester.com\/et\/tootekategooria\/iso\/iso-9187\/\" target=\"_blank\" rel=\"noopener\">ISO 9187<\/a><\/strong><\/h3>\n<p>The test involves placing an ampoule on a fixture and applying a downward force to the neck using the testing machine. The <strong>BST-01 Ampoule Break Force Tester<\/strong> uses a high-precision load cell to measure the force required to break the neck of the ampoule. The test ensures the ampoules are not only safe to handle but also meet the required standards for pharmaceutical applications.<\/p>\n<h2><strong>Test Process of the Ampoule Break Force Tester<\/strong><\/h2>\n<ul>\n<li><strong>Step 1<\/strong>: Place the ampoule on the dedicated fixture designed for different ampoule sizes (1ml, 2ml, 5ml, 10ml, 20ml).<\/li>\n<li><strong>Step 2<\/strong>: Start the test, where the pressing head moves down at a consistent rate of 10 mm\/min (adjustable from 1\u2013500 mm\/min).<\/li>\n<li><strong>Step 3<\/strong>: The high-precision load cell detects the force required to break the ampoule neck.<\/li>\n<li><strong>Step 4<\/strong>: The breaking force is recorded, and results are displayed on the HMI touch screen or printed via the integrated microprinter.<\/li>\n<\/ul>\n<p>This process ensures the breaking force of ampoules is accurately measured according to industry standards.<\/p>\n<h2><strong>Technical Features of the BST-01 Ampoule Breaking Strength Tester<\/strong><\/h2>\n<p>The <strong>BST-01 Ampoule Breaking Strength Tester<\/strong> is equipped with a range of advanced features that enhance its accuracy and versatility:<\/p>\n<ul>\n<li><strong>K\u00f5rge t\u00e4psusega koormusandur<\/strong>: Ensures reliable and precise force measurements with a resolution of 0.1N.<\/li>\n<li><strong>Multiple Fixture Options<\/strong>: Test fixtures for 1ml, 2ml, 5ml, 10ml, and 20ml ampoules allow the tester to accommodate various ampoule sizes.<\/li>\n<li><strong>Reguleeritav testikiirus<\/strong>: The test speed is adjustable between 1 and 500 mm\/min, catering to different testing requirements.<\/li>\n<li><strong>PLC juhtimine ja HMI puuteekraan<\/strong>: For easy operation and automation of the testing process.<\/li>\n<li><strong>Stepper Motor with Precision Ball-Lead Screw<\/strong>: Provides accurate speed control for precise testing.<\/li>\n<li><strong>Ohutusfunktsioonid<\/strong>: Includes a protective cover to prevent sample jump, a collection tube for broken ampoule samples, and automatic return functionality.<\/li>\n<li><strong>Optional Connectivity<\/strong>: RS 232 connectivity for integration with professional software and systems.<\/li>\n<\/ul>\n<h2><strong>Other Relevant Standards and Compliance<\/strong><\/h2>\n<p>Lisaks <strong>ISO 9187<\/strong>, ... <strong>BST-01 Ampoule Break Force Tester<\/strong> complies with several other industry standards, including:<\/p>\n<ul>\n<li><strong>GB 2637<\/strong>: A Chinese national standard for ampoule testing.<\/li>\n<li><strong>YBB00332002<\/strong>: A Chinese standard for ampoules used in pharmaceutical packaging.<\/li>\n<\/ul>\n<p>These standards ensure the device&#8217;s versatility and compliance with global testing requirements.<\/p>\n<h2><strong>Main Parameters of the Ampoule Break Force Tester<\/strong><\/h2>\n<table>\n<tbody>\n<tr>\n<td style=\"text-align: center;\" width=\"87\">Katse ulatus<\/td>\n<td style=\"text-align: center;\" width=\"188\">0~200N (v\u00f5i vastavalt vajadusele)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"87\">Kiirus<\/td>\n<td style=\"text-align: center;\" width=\"188\">1~500mm\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"87\">Resolutsioon<\/td>\n<td style=\"text-align: center;\" width=\"188\">0.1N<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"87\">T\u00e4psus<\/td>\n<td style=\"text-align: center;\" width=\"188\">0,5% F.S.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"87\">V\u00f5imsus<\/td>\n<td style=\"text-align: center;\" width=\"188\">110~ 220V 50\/60Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The <strong>BST-01 Ampoule Break Force Tester<\/strong> is a reliable, versatile, and highly accurate device designed to meet the rigorous testing requirements of the pharmaceutical and medical packaging industries. By adhering to international standards such as <strong>ISO 9187<\/strong>, the tester ensures that ampoules are safe to use and meet the necessary breaking force specifications. With its advanced features, flexibility in testing different ampoule sizes, and ease of use, the BST-01 is an indispensable tool for manufacturers and quality control labs.<\/p>\n<h4><strong>KKK jaotis<\/strong><\/h4>\n<ol>\n<li><strong>What is the purpose of an ampoule break force tester?<\/strong><br \/>\nThe tester measures the force required to break the neck of an ampoule, ensuring its strength and safety during handling and use.<\/li>\n<li><strong>How does ISO 9187 relate to ampoule testing?<\/strong><br \/>\nISO 9187 outlines the method and guidelines for testing the breaking force of ampoules, ensuring consistency and reliability in the testing process.<\/li>\n<li><strong>What are the key technical features of the BST-01 Ampoule Break Force Tester?<\/strong><br \/>\nThe tester features a high-precision load cell, multiple fixture sizes, adjustable test speeds, PLC control, and safety features such as protective covers and collection tubes.<\/li>\n<li><strong>Can the BST-01 be used to test other materials besides ampoules?<\/strong><br \/>\nYes, the BST-01 is versatile and can test other medical packaging materials such as syringes, caps, and stoppers.<\/li>\n<li><strong>What is the accuracy of the BST-01 Ampoule Break Force Tester?<\/strong><br \/>\nThe tester offers an accuracy of 0.5% full scale (F.S.), providing precise and reliable test results.<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>The <strong>ampulli purunemise j\u00f5u tester<\/strong> on oluline vahend farmaatsia- ja meditsiinipakendit\u00f6\u00f6stuses, mis on m\u00f5eldud ampulli kaela murdmiseks vajaliku j\u00f5u m\u00f5\u00f5tmiseks. Ampullid on hermeetiliselt suletud mahutid, mida kasutatakse tundlike farmaatsiatoodete s\u00e4ilitamiseks. Kaela purunemistugevus m\u00e4ngib olulist rolli selles sisalduva toote ohutuse ja terviklikkuse tagamisel. T\u00e4pne ja usaldusv\u00e4\u00e4rne tester on oluline, et ampullid vastaksid ohutuks kasutamiseks ja k\u00e4sitsemiseks vajalikele standarditele.<\/p>","protected":false},"featured_media":6120,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":""},"product_cat":[933,845,149,173,95],"product_tag":[],"class_list":{"0":"post-3223","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ampoule-breaking-tester","7":"product_cat-customization","8":"product_cat-pharma-and-medical-testers","9":"product_cat-iso-9187","10":"product_cat-products","11":"desktop-align-left","12":"tablet-align-left","13":"mobile-align-left","15":"first","16":"instock","17":"shipping-taxable","18":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/product\/3223","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/comments?post=3223"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/product\/3223\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/media\/6120"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/media?parent=3223"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/product_cat?post=3223"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.qualitester.com\/et\/wp-json\/wp\/v2\/product_tag?post=3223"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}