{"id":7929,"date":"2026-04-22T11:23:21","date_gmt":"2026-04-22T03:23:21","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7929"},"modified":"2026-04-22T11:23:21","modified_gmt":"2026-04-22T03:23:21","slug":"astm-f2824","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/cs\/standards\/astm-f2824\/","title":{"rendered":"ASTM F2824"},"content":{"rendered":"<h2 data-section-id=\"1u91ctg\" data-start=\"462\" data-end=\"517\">Porozum\u011bn\u00ed norm\u011b ASTM F2824 v oblasti integrity t\u011bsn\u011bn\u00ed obal\u016f<\/h2>\n<p data-start=\"519\" data-end=\"838\"><strong data-start=\"519\" data-end=\"533\">ASTM F2824<\/strong> definuje standardizovan\u00fd p\u0159\u00edstup k hodnocen\u00ed <strong data-start=\"582\" data-end=\"672\">mechanick\u00e1 pevnost t\u011bsn\u011bn\u00ed kulat\u00fdch hrnk\u016f a misek s pru\u017en\u00fdmi odlupovac\u00edmi v\u00ed\u010dky.<\/strong>. Na rozd\u00edl od test\u016f \u010d\u00e1ste\u010dn\u00e9 t\u011bsnosti tato metoda hodnot\u00ed. <strong data-start=\"726\" data-end=\"754\">cel\u00e9 t\u011bsnic\u00ed rozhran\u00ed<\/strong>, co\u017e poskytuje realisti\u010dt\u011bj\u0161\u00ed zobrazen\u00ed vlastnost\u00ed obalu b\u011bhem otev\u00edr\u00e1n\u00ed.<\/p>\n<p data-start=\"840\" data-end=\"1180\">Toto rozli\u0161en\u00ed je d\u016fle\u017eit\u00e9 v odv\u011btv\u00edch, jako je potravin\u00e1\u0159stv\u00ed, farmacie a spot\u0159ebn\u00ed zbo\u017e\u00ed, kde <strong data-start=\"935\" data-end=\"975\">konzistence t\u011bsn\u011bn\u00ed a u\u017eivatelsk\u00fd komfort<\/strong> p\u0159\u00edmo ovliv\u0148uj\u00ed bezpe\u010dnost v\u00fdrobku a vn\u00edm\u00e1n\u00ed zna\u010dky. M\u011b\u0159en\u00edm obou <strong data-start=\"1047\" data-end=\"1085\">maxim\u00e1ln\u00ed s\u00edla a trval\u00e1 s\u00edla<\/strong>, ASTM F2824 poskytuje komplexn\u00ed soubor \u00fadaj\u016f, kter\u00fd pom\u00e1h\u00e1 in\u017een\u00fdr\u016fm optimalizovat parametry t\u011bsn\u011bn\u00ed.<\/p>\n<h2 data-section-id=\"hwu0f4\" data-start=\"1187\" data-end=\"1241\">Zkou\u0161ka odlupov\u00e1n\u00ed ohebn\u00e9ho v\u00edka: Metoda hodnocen\u00ed \u00fapln\u00e9ho ut\u011bsn\u011bn\u00ed<\/h2>\n<p data-start=\"1243\" data-end=\"1527\">Na str\u00e1nk\u00e1ch <strong data-start=\"1247\" data-end=\"1273\">zkou\u0161ka odlupov\u00e1n\u00ed pru\u017en\u00e9ho v\u00edka<\/strong> popsan\u00fd v norm\u011b ASTM F2824 se zam\u011b\u0159uje na odd\u011blen\u00ed v\u00edka od n\u00e1doby pod\u00e9l definovan\u00e9 linie odlupov\u00e1n\u00ed. Metoda pou\u017e\u00edv\u00e1 <strong data-start=\"1392\" data-end=\"1433\">\u0159\u00edzen\u00fd \u00fahel odlupov\u00e1n\u00ed (obvykle 45\u00b0)<\/strong> a <strong data-start=\"1440\" data-end=\"1482\">konstantn\u00ed separa\u010dn\u00ed rychlost 300 mm\/min<\/strong>, co\u017e zaji\u0161\u0165uje opakovateln\u00e9 a srovnateln\u00e9 v\u00fdsledky.<\/p>\n<p data-start=\"1529\" data-end=\"1560\">Mezi hlavn\u00ed m\u011b\u0159iteln\u00e9 v\u00fdstupy pat\u0159\u00ed:<\/p>\n<ul data-start=\"1562\" data-end=\"1752\">\n<li data-section-id=\"1mrfg10\" data-start=\"1562\" data-end=\"1622\"><strong data-start=\"1564\" data-end=\"1589\">Maxim\u00e1ln\u00ed pevnost t\u011bsn\u011bn\u00ed<\/strong> - \u0161pi\u010dkov\u00e1 s\u00edla p\u0159i odd\u011blov\u00e1n\u00ed<\/li>\n<li data-section-id=\"1vir9r4\" data-start=\"1623\" data-end=\"1688\"><strong data-start=\"1625\" data-end=\"1650\">Pr\u016fm\u011brn\u00e1 pevnost t\u011bsn\u011bn\u00ed<\/strong> - pr\u016fm\u011brn\u00e1 s\u00edla v cel\u00e9m t\u011bsn\u011bn\u00ed<\/li>\n<li data-section-id=\"zagy5r\" data-start=\"1689\" data-end=\"1752\"><strong data-start=\"1691\" data-end=\"1708\">Pr\u00e1ce (energie)<\/strong> - plocha pod k\u0159ivkou s\u00edla-posun<\/li>\n<\/ul>\n<p data-start=\"1754\" data-end=\"1961\"><strong data-start=\"1754\" data-end=\"1773\">Pro\u010d je to d\u016fle\u017eit\u00e9:<\/strong><br data-start=\"1773\" data-end=\"1776\" \/>Testov\u00e1n\u00ed cel\u00e9ho t\u011bsn\u011bn\u00ed odhal\u00ed slab\u00e1 m\u00edsta, kter\u00e1 by \u010d\u00e1ste\u010dn\u00e9 testov\u00e1n\u00ed mohlo p\u0159ehl\u00e9dnout. Tento p\u0159\u00edstup zlep\u0161uje <strong data-start=\"1877\" data-end=\"1905\">p\u0159esnost kontroly kvality<\/strong> a sni\u017euje riziko selh\u00e1n\u00ed t\u011bsn\u011bn\u00ed v re\u00e1ln\u00e9m provozu.<\/p>\n<h2 data-section-id=\"17vdz0y\" data-start=\"1968\" data-end=\"2028\">Zkou\u0161ka pevnosti t\u011bsn\u011bn\u00ed poh\u00e1r\u016f: Postup a kl\u00ed\u010dov\u00e9 parametry<\/h2>\n<p data-start=\"2030\" data-end=\"2124\">Na str\u00e1nk\u00e1ch <strong data-start=\"2034\" data-end=\"2065\">zkou\u0161ka pevnosti t\u011bsn\u011bn\u00ed \u0161\u00e1lk\u016f<\/strong> se \u0159\u00edd\u00ed strukturovan\u00fdm postupem, aby byla zaji\u0161t\u011bna spolehlivost \u00fadaj\u016f:<\/p>\n<h3 data-section-id=\"15ji579\" data-start=\"2126\" data-end=\"2158\">P\u0159\u00edprava a nastaven\u00ed vzorku<\/h3>\n<ul data-start=\"2159\" data-end=\"2313\">\n<li data-section-id=\"1rp1ybn\" data-start=\"2159\" data-end=\"2203\">N\u00e1dobu pevn\u011b zajist\u011bte v dr\u017e\u00e1ku<\/li>\n<li data-section-id=\"1g5n0yd\" data-start=\"2204\" data-end=\"2256\">P\u0159ipevn\u011bte v\u00fdstupek v\u00edka k \u00fachytu pro m\u011b\u0159en\u00ed s\u00edly.<\/li>\n<li data-section-id=\"1gj5r50\" data-start=\"2257\" data-end=\"2313\">Vyrovnejte sm\u011br loup\u00e1n\u00ed pod\u00e9l definovan\u00e9 linie loup\u00e1n\u00ed.<\/li>\n<\/ul>\n<h3 data-section-id=\"10bgihu\" data-start=\"2315\" data-end=\"2333\">Proveden\u00ed testu<\/h3>\n<ul data-start=\"2334\" data-end=\"2499\">\n<li data-section-id=\"5vmwcl\" data-start=\"2334\" data-end=\"2384\">Nastavte rychlost loup\u00e1n\u00ed na <strong data-start=\"2354\" data-end=\"2382\">300 mm\/min (\u00b1 tolerance)<\/strong><\/li>\n<li data-section-id=\"1420z8g\" data-start=\"2385\" data-end=\"2445\">Udr\u017eujte <strong data-start=\"2398\" data-end=\"2416\">\u00dahel odlupov\u00e1n\u00ed 45\u00b0<\/strong> pokud nen\u00ed potvrzeno jinak<\/li>\n<li data-section-id=\"15vb11n\" data-start=\"2446\" data-end=\"2499\">Zahajte nep\u0159etr\u017eit\u00e9 odlupov\u00e1n\u00ed a\u017e do \u00fapln\u00e9ho odd\u011blen\u00ed<\/li>\n<\/ul>\n<h3 data-section-id=\"1wi3bsw\" data-start=\"2501\" data-end=\"2520\">Sb\u011br dat<\/h3>\n<ul data-start=\"2521\" data-end=\"2678\">\n<li data-section-id=\"1815teb\" data-start=\"2521\" data-end=\"2560\">Z\u00e1znam k\u0159ivky z\u00e1vislosti s\u00edly na posunu<\/li>\n<li data-section-id=\"1k9tvtq\" data-start=\"2561\" data-end=\"2616\">V\u00fdpis <strong data-start=\"2571\" data-end=\"2614\">maxim\u00e1ln\u00ed, pr\u016fm\u011brn\u00e9 a celkov\u00e9 hodnoty pr\u00e1ce<\/strong><\/li>\n<li data-section-id=\"1fq8wg1\" data-start=\"2617\" data-end=\"2678\">Opakov\u00e1n\u00ed u v\u00edce vzork\u016f pro statistickou spolehlivost<\/li>\n<\/ul>\n<p data-start=\"2680\" data-end=\"2786\"><strong data-start=\"2680\" data-end=\"2694\">D\u016fle\u017eit\u00e9:<\/strong> Kalibrace syst\u00e9mu m\u011b\u0159en\u00ed s\u00edly p\u0159ed testov\u00e1n\u00edm zaji\u0161\u0165uje p\u0159esnost a shodu.<\/p>\n<h2 data-section-id=\"xwx2gl\" data-start=\"2793\" data-end=\"2849\">Stroj na testov\u00e1n\u00ed odlupov\u00e1n\u00ed kontejner\u016f<\/h2>\n<p data-start=\"2851\" data-end=\"2999\">V\u00fdb\u011br spr\u00e1vn\u00e9ho <strong data-start=\"2870\" data-end=\"2906\">stroj na zkou\u0161en\u00ed loup\u00e1n\u00ed kontejner\u016f<\/strong> p\u0159\u00edmo ovliv\u0148uje opakovatelnost test\u016f a integritu dat. Vhodn\u00fd syst\u00e9m by m\u011bl poskytovat:<\/p>\n<ul data-start=\"3001\" data-end=\"3213\">\n<li data-section-id=\"r2uwqm\" data-start=\"3001\" data-end=\"3058\"><strong data-start=\"3003\" data-end=\"3034\">Stabiln\u00ed mechanick\u00e1 konstrukce<\/strong> pro konzistentn\u00ed pohyb<\/li>\n<li data-section-id=\"196ogz1\" data-start=\"3059\" data-end=\"3108\"><strong data-start=\"3061\" data-end=\"3086\">P\u0159esn\u00e1 regulace ot\u00e1\u010dek<\/strong> v \u0161irok\u00e9 \u0161k\u00e1le<\/li>\n<li data-section-id=\"omtz22\" data-start=\"3109\" data-end=\"3152\"><strong data-start=\"3111\" data-end=\"3150\">Vizualizace k\u0159ivky s\u00edly v re\u00e1ln\u00e9m \u010dase<\/strong><\/li>\n<li data-section-id=\"bx7jgq\" data-start=\"3153\" data-end=\"3213\"><strong data-start=\"3155\" data-end=\"3176\">Flexibiln\u00ed p\u0159\u00edslu\u0161enstv\u00ed<\/strong> pro r\u016fzn\u00e9 geometrie kontejner\u016f<\/li>\n<\/ul>\n<p data-start=\"3215\" data-end=\"3321\">Praktick\u00fdm \u0159e\u0161en\u00edm je <strong data-start=\"3243\" data-end=\"3304\">Cell Instruments CCPT-01 <a href=\"https:\/\/www.qualitester.com\/cs\/produkt-2\/sale-yogurt-container-lid-film-peel-tester\/\">Tester loup\u00e1n\u00ed poh\u00e1rk\u016f a n\u00e1dob<\/a><\/strong>, kter\u00fd podporuje:<\/p>\n<ul data-start=\"3323\" data-end=\"3586\">\n<li data-section-id=\"nwgosf\" data-start=\"3323\" data-end=\"3379\">P\u0159esn\u00e9 m\u011b\u0159en\u00ed s\u00edly s programovateln\u00fdm \u0159\u00edzen\u00edm<\/li>\n<li data-section-id=\"gl9x7i\" data-start=\"3380\" data-end=\"3443\">Nastaviteln\u00e9 zku\u0161ebn\u00ed rychlosti v souladu s po\u017eadavky normy ASTM F2824<\/li>\n<li data-section-id=\"k65zb2\" data-start=\"3444\" data-end=\"3512\">Automatick\u00fd v\u00fdpo\u010det <strong data-start=\"3471\" data-end=\"3510\">maxim\u00e1ln\u00ed, minim\u00e1ln\u00ed a pr\u016fm\u011brn\u00e1 s\u00edla<\/strong><\/li>\n<li data-section-id=\"1iq1s3u\" data-start=\"3513\" data-end=\"3586\">P\u0159\u00edpravky na zak\u00e1zku, v\u010detn\u011b vakuov\u00e9ho up\u00edn\u00e1n\u00ed pro specializovan\u00e9 n\u00e1doby<\/li>\n<\/ul>\n<p data-start=\"3588\" data-end=\"3713\">Tento typ syst\u00e9mu pom\u00e1h\u00e1 laborato\u0159\u00edm dos\u00e1hnout <strong data-start=\"3635\" data-end=\"3677\">opakovateln\u00e9 v\u00fdsledky v souladu s normami<\/strong> a z\u00e1rove\u0148 zv\u00fd\u0161it efektivitu testov\u00e1n\u00ed.<\/p>\n<h2 data-section-id=\"pfpup2\" data-start=\"3720\" data-end=\"3771\">ASTM F2824 vs. tradi\u010dn\u00ed metody pevnosti t\u011bsn\u011bn\u00ed<\/h2>\n<p data-start=\"3773\" data-end=\"3880\">\u010casto se objevuje srovn\u00e1n\u00ed mezi <strong data-start=\"3808\" data-end=\"3822\">ASTM F2824<\/strong> a tradi\u010dn\u00ed metody, jako je testov\u00e1n\u00ed t\u011bsnosti pomoc\u00ed prou\u017ek\u016f.<\/p>\n<p data-start=\"3882\" data-end=\"3901\"><strong data-start=\"3882\" data-end=\"3901\">Hlavn\u00ed rozd\u00edl:<\/strong><\/p>\n<ul data-start=\"3903\" data-end=\"4016\">\n<li data-section-id=\"1urh6d9\" data-start=\"3903\" data-end=\"3952\">ASTM F2824 \u2192 hodnot\u00ed <strong data-start=\"3928\" data-end=\"3950\">odstran\u011bn\u00ed cel\u00e9ho v\u00edka<\/strong><\/li>\n<li data-section-id=\"66chi5\" data-start=\"3953\" data-end=\"4016\">Konven\u010dn\u00ed metody \u2192 vyhodnotit <strong data-start=\"3987\" data-end=\"4014\">lokalizovan\u00e9 \u00faseky t\u011bsn\u011bn\u00ed<\/strong><\/li>\n<\/ul>\n<p data-start=\"4018\" data-end=\"4195\"><strong data-start=\"4018\" data-end=\"4034\">D\u016fsledky:<\/strong><br data-start=\"4034\" data-end=\"4037\" \/>Norma ASTM F2824 nab\u00edz\u00ed <strong data-start=\"4057\" data-end=\"4094\">holistick\u00fd pohled na v\u00fdkonnost t\u011bsn\u011bn\u00ed<\/strong>, tak\u017ee je vhodn\u011bj\u0161\u00ed pro <strong data-start=\"4124\" data-end=\"4157\">validace spot\u0159ebitelsk\u00fdch obal\u016f<\/strong>, kde z\u00e1le\u017e\u00ed na chov\u00e1n\u00ed p\u0159i \u00fapln\u00e9m otev\u0159en\u00ed.<\/p>\n<h2 data-section-id=\"15s9sbd\" data-start=\"4555\" data-end=\"4604\">Z\u00edskejte spolehliv\u00e9 \u0159e\u0161en\u00ed pro testov\u00e1n\u00ed ASTM F2824<\/h2>\n<p data-start=\"6408\" data-end=\"6879\">Zajist\u011bte, aby va\u0161e obaly spl\u0148ovaly po\u017eadavky normy ASTM F2824 pomoc\u00ed p\u0159esn\u00e9ho a opakovateln\u00e9ho testov\u00e1n\u00ed pevnosti t\u011bsn\u011bn\u00ed. Tato metoda simuluje skute\u010dn\u00e9 odstran\u011bn\u00ed v\u00edka a pom\u00e1h\u00e1 identifikovat slab\u00e9 t\u011bsn\u011bn\u00ed, optimalizovat v\u00fdrobn\u00ed parametry a zlep\u0161it u\u017eivatelsk\u00fd komfort. S pokro\u010dil\u00fdmi testovac\u00edmi \u0159e\u0161en\u00edmi, jako je CCPT-01, m\u016f\u017eete dos\u00e1hnout p\u0159esn\u00e9ho m\u011b\u0159en\u00ed s\u00edly, d\u016fsledn\u00e9 kontroly odlepov\u00e1n\u00ed a spolehliv\u00e9 anal\u00fdzy dat - co\u017e podporuje zaji\u0161t\u011bn\u00ed kvality a shody v n\u00e1ro\u010dn\u00fdch obalov\u00fdch aplikac\u00edch.<\/p>\n<h2 data-section-id=\"w1c0q0\" data-start=\"4965\" data-end=\"5000\">Nej\u010dast\u011bj\u0161\u00ed dotazy<\/h2>\n<p data-start=\"5002\" data-end=\"5188\"><strong data-start=\"5002\" data-end=\"5063\">1. V \u010dem se ASTM F2824 li\u0161\u00ed od jin\u00fdch test\u016f t\u011bsnosti?<\/strong><br data-start=\"5063\" data-end=\"5066\" \/>Norma ASTM F2824 hodnot\u00ed <strong data-start=\"5091\" data-end=\"5113\">odstran\u011bn\u00ed cel\u00e9ho v\u00edka<\/strong>, nikoliv pouze \u010d\u00e1st t\u011bsn\u011bn\u00ed, kter\u00e1 poskytuje kompletn\u00ed v\u00fdkonnostn\u00ed profil.<\/p>\n<p data-start=\"5190\" data-end=\"5354\"><strong data-start=\"5190\" data-end=\"5233\">2. Pro\u010d je d\u016fle\u017eit\u00fd \u00fahel odlupov\u00e1n\u00ed 45\u00b0?<\/strong><br data-start=\"5233\" data-end=\"5236\" \/>Standardizuje podm\u00ednky testov\u00e1n\u00ed a zaji\u0161\u0165uje <strong data-start=\"5283\" data-end=\"5305\">srovnateln\u00e9 v\u00fdsledky<\/strong>, a\u010dkoli lze pou\u017e\u00edt i jin\u00e9 \u00fahly, pokud se potvrd\u00ed.<\/p>\n<p data-start=\"5356\" data-end=\"5523\"><strong data-start=\"5356\" data-end=\"5408\">3. Pro jak\u00e1 odv\u011btv\u00ed je norma ASTM F2824 nejp\u0159\u00ednosn\u011bj\u0161\u00ed?<\/strong><br data-start=\"5408\" data-end=\"5411\" \/>Potravin\u00e1\u0159sk\u00fd, farmaceutick\u00fd a spot\u0159ebn\u00ed pr\u016fmysl t\u011b\u017e\u00ed ze sv\u00e9 z\u00e1vislosti na <strong data-start=\"5496\" data-end=\"5522\">obaly s odlupovac\u00edm v\u00edkem<\/strong>.<\/p>\n<p data-start=\"5525\" data-end=\"5671\"><strong data-start=\"5525\" data-end=\"5579\">4. Jak\u00e9 parametry jsou p\u0159i tomto testu nejkriti\u010dt\u011bj\u0161\u00ed?<\/strong><br data-start=\"5579\" data-end=\"5582\" \/><strong data-start=\"5582\" data-end=\"5635\">P\u0159esnost m\u011b\u0159en\u00ed rychlosti, \u00fahlu a s\u00edly loup\u00e1n\u00ed<\/strong> jsou nezbytn\u00e9 pro spolehliv\u00e9 v\u00fdsledky.<\/p>\n<p data-start=\"5673\" data-end=\"5835\"><strong data-start=\"5673\" data-end=\"5715\">5. Lze testovat i jin\u00e9 ne\u017e kulat\u00e9 n\u00e1doby?<\/strong><br data-start=\"5715\" data-end=\"5718\" \/>Zat\u00edmco <a href=\"https:\/\/store.astm.org\/f2824-10r25.html\" target=\"_blank\" rel=\"noopener nofollow\">ASTM F2824<\/a> se zam\u011b\u0159uje na kulat\u00e9 kontejnery, podobn\u00e9 metody lze po n\u00e1le\u017eit\u00e9 validaci p\u0159izp\u016fsobit i pro jin\u00e9 tvary.<\/p>","protected":false},"excerpt":{"rendered":"<p>Understanding ASTM F2824 in Packaging Seal Integrity ASTM F2824 defines a standardized approach to evaluate the mechanical seal strength of round cups and bowl containers with flexible peelable lids. Unlike partial seal tests, this method assesses the entire sealing interface, providing a more realistic representation of packaging performance during opening. This distinction matters in industries &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/cs\/standards\/astm-f2824\/\"> <span class=\"screen-reader-text\">ASTM F2824<\/span> Pokra\u010dovat ve \u010dten\u00ed \"<\/a><\/p>","protected":false},"author":4,"featured_media":7931,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7929","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages\/7929","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/comments?post=7929"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages\/7929\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages\/4948"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/media\/7931"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/media?parent=7929"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}