{"id":7754,"date":"2025-12-26T14:04:58","date_gmt":"2025-12-26T06:04:58","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7754"},"modified":"2025-12-26T14:06:03","modified_gmt":"2025-12-26T06:06:03","slug":"astm-d6653","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/cs\/standards\/astm-d6653\/","title":{"rendered":"ASTM D6653"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"388\" data-end=\"734\">ASTM D6653<\/h1>\n<h1 style=\"text-align: center;\" data-start=\"388\" data-end=\"734\">Vakuov\u00e1 zkou\u0161ka t\u011bsnosti<\/h1>\n<p data-start=\"6041\" data-end=\"6231\">Na str\u00e1nk\u00e1ch <a href=\"https:\/\/www.qualitester.com\/cs\/applications\/vacuum-leak-test-for-bottles\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"398\" data-end=\"412\">ASTM D6653<\/strong><\/a> Norma popisuje metodu pro zkou\u0161en\u00ed integrity obalov\u00fdch syst\u00e9m\u016f vystaven\u00fdch podm\u00ednk\u00e1m ve vysok\u00fdch nadmo\u0159sk\u00fdch v\u00fd\u0161k\u00e1ch. Tato zkou\u0161ka je kl\u00ed\u010dov\u00e1 pro ur\u010den\u00ed toho, jak si v\u00fdrobky a jejich obalov\u00e9 syst\u00e9my vedou p\u0159i tlakov\u00fdch rozd\u00edlech, ke kter\u00fdm doch\u00e1z\u00ed b\u011bhem p\u0159epravy, zejm\u00e9na v dopravn\u00edch letadlech p\u0159el\u00e9t\u00e1vaj\u00edc\u00edch vysokohorsk\u00e9 pr\u016fsmyky. Tato <strong data-start=\"740\" data-end=\"760\">zkou\u0161ka t\u011bsnosti ve vakuu<\/strong> Metoda, stanoven\u00e1 v t\u00e9to norm\u011b, posuzuje odolnost obalov\u00fdch syst\u00e9m\u016f p\u0159i takov\u00fdch zm\u011bn\u00e1ch tlaku.<\/p>\n<hr \/>\n<h2 data-start=\"6041\" data-end=\"6231\">Porozum\u011bn\u00ed norm\u011b ASTM D6653 a jej\u00edmu v\u00fdznamu<\/h2>\n<p data-start=\"956\" data-end=\"1425\"><strong data-start=\"956\" data-end=\"970\">ASTM D6653<\/strong> jedn\u00e1 se o standardn\u00ed zku\u0161ebn\u00ed metodu pro hodnocen\u00ed vlivu podm\u00ednek ve vysok\u00fdch nadmo\u0159sk\u00fdch v\u00fd\u0161k\u00e1ch na obalov\u00e9 syst\u00e9my. Zkou\u0161ka simuluje tlakov\u00e9 rozd\u00edly, kter\u00fdm jsou v\u00fdrobky vystaveny b\u011bhem leteck\u00e9 p\u0159epravy, nap\u0159\u00edklad v dopravn\u00edch letadlech, kter\u00e1 mohou dosahovat nadmo\u0159sk\u00fdch v\u00fd\u0161ek 5 791 metr\u016f (19 000 stop) nebo v\u00edce. Tato zku\u0161ebn\u00ed metoda prim\u00e1rn\u011b posuzuje <strong data-start=\"1297\" data-end=\"1322\">detekce \u00fanik\u016f ve vakuu<\/strong> v balic\u00edch syst\u00e9mech, kter\u00e9 si mus\u00ed zachovat svou neporu\u0161enost i p\u0159i vystaven\u00ed t\u011bmto extr\u00e9mn\u00edm podm\u00ednk\u00e1m.<\/p>\n<p data-start=\"1427\" data-end=\"1762\">Tento test je nezbytn\u00fd pro v\u00fdrobce obal\u016f, zejm\u00e9na pro ty, kte\u0159\u00ed pracuj\u00ed s citliv\u00fdmi produkty, jako jsou l\u00e9\u010diva, zdravotnick\u00e9 prost\u0159edky nebo potraviny, u nich\u017e je neporu\u0161enost obalu z\u00e1sadn\u00ed. Simulac\u00ed re\u00e1ln\u00fdch podm\u00ednek tento test zaji\u0161\u0165uje, \u017ee obalov\u00fd syst\u00e9m nesel\u017ee ani nedojde ke kontaminaci v d\u016fsledku zm\u011bn tlaku.<\/p>\n<hr \/>\n<h2 data-start=\"1427\" data-end=\"1762\">Hlavn\u00ed sou\u010d\u00e1sti zku\u0161ebn\u00ed metody ASTM D6653<a href=\"https:\/\/www.qualitester.com\/cs\/applications\/vacuum-leak-test-for-bottles\/\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-7757 alignright\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test-300x300.webp\" alt=\"ASTM D6653 \u2013 Zkou\u0161ka t\u011bsnosti ve vakuu\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/12\/ASTM-D6653-Vacuum-Leak-Test.webp 600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/h2>\n<p>Na str\u00e1nk\u00e1ch <strong data-start=\"1822\" data-end=\"1842\">zkou\u0161ka t\u011bsnosti ve vakuu<\/strong> pops\u00e1no v <strong data-start=\"1856\" data-end=\"1870\">ASTM D6653<\/strong> spo\u010d\u00edv\u00e1 v tom, \u017ee se zku\u0161ebn\u00ed vzorek, j\u00edm\u017e je sestaven\u00fd obalov\u00fd syst\u00e9m, vystav\u00ed simulovan\u00fdm podm\u00ednk\u00e1m ve vysok\u00e9 nadmo\u0159sk\u00e9 v\u00fd\u0161ce. Tlakov\u00fd rozd\u00edl zp\u016fsob\u00ed rozta\u017een\u00ed obalov\u00e9ho syst\u00e9mu a jeho neporu\u0161enost se ov\u011b\u0159uje m\u011b\u0159en\u00edm <strong data-start=\"2100\" data-end=\"2120\">t\u011bsnost vakuov\u00e9ho syst\u00e9mu<\/strong> a p\u0159\u00edpadn\u00e9 \u00faniky \u010di deformace, k nim\u017e m\u016f\u017ee doj\u00edt.<\/p>\n<hr \/>\n<h2>P\u0159\u00edstroje pot\u0159ebn\u00e9 pro zkou\u0161ku<\/h2>\n<p data-start=\"2210\" data-end=\"2271\">K proveden\u00ed vakuov\u00e9 zkou\u0161ky t\u011bsnosti je zapot\u0159eb\u00ed n\u00e1sleduj\u00edc\u00ed vybaven\u00ed:<\/p>\n<ol data-start=\"2273\" data-end=\"2831\">\n<li data-start=\"2273\" data-end=\"2510\">\n<p data-start=\"2276\" data-end=\"2510\"><strong data-start=\"2276\" data-end=\"2294\">Vakuov\u00e1 komora<\/strong> \u2013 Komora schopn\u00e1 odolat tlakov\u00e9mu rozd\u00edlu p\u0159ibli\u017en\u011b jedn\u00e9 atmosf\u00e9ry. Tato komora mus\u00ed m\u00edt vakuov\u011b t\u011bsn\u00e9 v\u00edko a mus\u00ed b\u00fdt dostate\u010dn\u011b velk\u00e1, aby pojala zku\u0161ebn\u00ed vzorek a z\u00e1rove\u0148 umo\u017enila jeho rozta\u017een\u00ed.<\/p>\n<\/li>\n<li data-start=\"2515\" data-end=\"2718\">\n<p data-start=\"2518\" data-end=\"2718\"><strong data-start=\"2518\" data-end=\"2545\">Vakuometr a zdroj vakua<\/strong> \u2013 Vysoce p\u0159esn\u00fd vakuometr s m\u011b\u0159ic\u00edm rozsahem 0 a\u017e 100 kPa (0 a\u017e 30 in. Hg), p\u0159esnost\u00ed \u00b12%, vstupn\u00ed trubic\u00ed napojenou na zdroj vakua a v\u00fdstupn\u00ed trubic\u00ed vedouc\u00ed do atmosf\u00e9ry.<\/p>\n<\/li>\n<li data-start=\"2723\" data-end=\"2831\">\n<p data-start=\"2726\" data-end=\"2831\"><strong data-start=\"2726\" data-end=\"2745\">Ovl\u00e1dac\u00ed prvky vakuov\u00e9ho syst\u00e9mu<\/strong> \u2013 Ru\u010dn\u00ed ventily pro \u0159\u00edzen\u00ed uvol\u0148ov\u00e1n\u00ed a vytv\u00e1\u0159en\u00ed podtlaku stanovenou rychlost\u00ed.<\/p>\n<\/li>\n<\/ol>\n<hr \/>\n<h2>Postup p\u0159i prov\u00e1d\u011bn\u00ed testu<\/h2>\n<ul>\n<li data-start=\"2876\" data-end=\"3095\">\n<p data-start=\"2879\" data-end=\"3095\"><strong data-start=\"2879\" data-end=\"2904\">P\u0159\u00edprava vzorku:<\/strong><br data-start=\"2904\" data-end=\"2907\" \/>Testovan\u00fd obalov\u00fd syst\u00e9m se pe\u010dliv\u011b p\u0159iprav\u00ed tak, aby odpov\u00eddal typick\u00e9 v\u00fdrobn\u00ed s\u00e9rii. Zku\u0161ebn\u00ed vzorek se nech\u00e1 kondicionovat p\u0159i teplot\u011b 5,6 \u00b1 2 \u00b0C [42 \u00b1 3,6 \u00b0F] po dobu nejm\u00e9n\u011b 24 hodin.<\/p>\n<\/li>\n<li data-start=\"3097\" data-end=\"3291\">\n<p data-start=\"3100\" data-end=\"3291\"><strong data-start=\"3100\" data-end=\"3125\">Nastaven\u00ed vakuov\u00e9 komory:<\/strong><br data-start=\"3125\" data-end=\"3128\" \/>Vlo\u017ete vzorek do vakuov\u00e9 komory a ujist\u011bte se, \u017ee je komora ut\u011bsn\u011bna. Vstupn\u00ed ventil komory je uzav\u0159en a v\u00fdstupn\u00ed ventil je otev\u0159en, aby bylo mo\u017en\u00e9 vytvo\u0159it vakuum.<\/p>\n<\/li>\n<li data-start=\"3293\" data-end=\"3543\">\n<p data-start=\"3296\" data-end=\"3543\"><strong data-start=\"3296\" data-end=\"3321\">P\u016fsoben\u00ed tlaku:<\/strong><br data-start=\"3321\" data-end=\"3324\" \/>Vakuum se vytv\u00e1\u0159\u00ed rychlost\u00ed p\u0159ibli\u017en\u011b 305 metr\u016f (1 000 stop) za 30\u201360 sekund. Tlak uvnit\u0159 komory se p\u0159i standardn\u00ed zkou\u0161ce sn\u00ed\u017e\u00ed na \u00farove\u0148 odpov\u00eddaj\u00edc\u00ed nadmo\u0159sk\u00e9 v\u00fd\u0161ce 16 000 stop \u00b15%.<\/p>\n<\/li>\n<li data-start=\"3545\" data-end=\"3677\">\n<p data-start=\"3548\" data-end=\"3677\"><strong data-start=\"3548\" data-end=\"3566\">Doba trv\u00e1n\u00ed testu:<\/strong><br data-start=\"3566\" data-end=\"3569\" \/>Vzorek je vystaven tomuto vakuu po dobu 60 minut, \u010d\u00edm\u017e se simuluj\u00ed \u00fa\u010dinky p\u0159epravy ve vysok\u00fdch nadmo\u0159sk\u00fdch v\u00fd\u0161k\u00e1ch.<\/p>\n<\/li>\n<li data-start=\"3679\" data-end=\"3835\">\n<p data-start=\"3682\" data-end=\"3835\"><strong data-start=\"3682\" data-end=\"3704\">Uvoln\u011bn\u00ed podtlaku:<\/strong><br data-start=\"3704\" data-end=\"3707\" \/>Po uplynut\u00ed doby trv\u00e1n\u00ed zkou\u0161ky se podtlak pomalu uvol\u0148uje a vzorek se zkontroluje, zda nevykazuje zn\u00e1mky po\u0161kozen\u00ed nebo deformace.<\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h2>Vyhodnocen\u00ed v\u00fdsledk\u016f<\/h2>\n<p>Po zkou\u0161ce se balic\u00ed syst\u00e9m pe\u010dliv\u011b zkontroluje, zda nevykazuje n\u011bjak\u00e9 zn\u00e1mky <strong data-start=\"3944\" data-end=\"3955\">\u00fanik<\/strong> nebo <strong data-start=\"3959\" data-end=\"3974\">deformace<\/strong>. Pokud obal zachov\u00e1 svou celistvost bez v\u00fdrazn\u00e9ho zdeformov\u00e1n\u00ed nebo \u00faniku, zkou\u0161ku spln\u00ed, co\u017e znamen\u00e1, \u017ee je schopen odolat podm\u00ednk\u00e1m ve vysok\u00fdch nadmo\u0159sk\u00fdch v\u00fd\u0161k\u00e1ch b\u011bhem p\u0159epravy. Pokud vzorek vykazuje zn\u00e1mky po\u0161kozen\u00ed, mohou v\u00fdrobci posoudit, zda tlakov\u00fd rozd\u00edl ovlivnil spoje nebo celistvost obalu.<\/p>\n<hr \/>\n<h2>Pro\u010d je vakuov\u00e1 zkou\u0161ka t\u011bsnosti d\u016fle\u017eit\u00e1 pro obaly?<\/h2>\n<p data-start=\"5053\" data-end=\"5309\">Obal hraje kl\u00ed\u010dovou roli p\u0159i ochran\u011b v\u00fdrobk\u016f, zejm\u00e9na v odv\u011btv\u00edch, jako je farmaceutick\u00fd pr\u016fmysl a potravin\u00e1\u0159stv\u00ed. <strong data-start=\"5164\" data-end=\"5187\">Vakuov\u00e9 zkou\u0161ky t\u011bsnosti<\/strong> zaji\u0161\u0165uje, \u017ee obal vydr\u017e\u00ed zm\u011bny tlaku, \u010d\u00edm\u017e zaru\u010duje, \u017ee produkty z\u016fstanou b\u011bhem p\u0159epravy v bezpe\u010d\u00ed a nezne\u010di\u0161t\u011bn\u00e9.<\/p>\n<p data-start=\"5311\" data-end=\"5582\">Pro v\u00fdrobce, <strong data-start=\"5330\" data-end=\"5344\">ASTM D6653<\/strong> poskytuje cenn\u00e9 \u00fadaje o v\u00fdkonu obal\u016f v extr\u00e9mn\u00edch podm\u00ednk\u00e1ch. Pomoc\u00ed t\u00e9to zkou\u0161ky mohou podniky ov\u011b\u0159it, zda jejich obalov\u00e1 \u0159e\u0161en\u00ed spl\u0148uj\u00ed pr\u016fmyslov\u00e9 normy pro p\u0159epravu ve vysok\u00fdch nadmo\u0159sk\u00fdch v\u00fd\u0161k\u00e1ch, a p\u0159edej\u00edt tak mo\u017en\u00fdm poruch\u00e1m v\u00fdrobk\u016f.<\/p>\n<hr \/>\n<h2 data-start=\"5311\" data-end=\"5582\">Z\u00e1v\u011br<\/h2>\n<p>Na str\u00e1nk\u00e1ch <strong data-start=\"5608\" data-end=\"5628\">zkou\u0161ka t\u011bsnosti ve vakuu<\/strong> jak je uvedeno v <strong data-start=\"5641\" data-end=\"5655\">ASTM D6653<\/strong> je pro v\u00fdrobce a odborn\u00edky na kontrolu kvality kl\u00ed\u010dov\u00fdm postupem pro posouzen\u00ed integrity obalov\u00fdch syst\u00e9m\u016f. Simulac\u00ed podm\u00ednek ve vysok\u00fdch nadmo\u0159sk\u00fdch v\u00fd\u0161k\u00e1ch tento test pom\u00e1h\u00e1 zajistit, aby v\u00fdrobky z\u016fstaly b\u011bhem p\u0159epravy bezpe\u010dn\u00e9 a nepo\u0161kozen\u00e9. Vyu\u017eit\u00edm <strong data-start=\"5906\" data-end=\"5940\">P\u0159\u00edstroje pro zkou\u0161ku t\u011bsnosti od spole\u010dnosti Cell Instruments<\/strong>, mohou v\u00fdrobci tyto zkou\u0161ky prov\u00e1d\u011bt s vysokou p\u0159esnost\u00ed a zajistit tak, \u017ee jejich obalov\u00e9 syst\u00e9my spl\u0148uj\u00ed p\u0159\u00edsn\u00e9 po\u017eadavky modern\u00edch p\u0159epravn\u00edch a distribu\u010dn\u00edch s\u00edt\u00ed.<\/p>\n<hr \/>\n<h2>\u010cASTO KLADEN\u00c9 DOTAZY<\/h2>\n<p>&nbsp;<\/p>\n<p data-start=\"92\" data-end=\"165\"><strong data-start=\"92\" data-end=\"165\">Ot\u00e1zka 1: Co je norma ASTM D6653 a pro\u010d je d\u016fle\u017eit\u00e1 pro obalov\u00e9 syst\u00e9my?<\/strong><\/p>\n<p data-start=\"167\" data-end=\"730\"><strong data-start=\"167\" data-end=\"174\">A1:<\/strong><br data-start=\"174\" data-end=\"177\" \/>ASTM D6653 je standardn\u00ed zku\u0161ebn\u00ed metoda, kter\u00e1 hodnot\u00ed vliv podm\u00ednek ve vysok\u00fdch nadmo\u0159sk\u00fdch v\u00fd\u0161k\u00e1ch na obalov\u00e9 syst\u00e9my, zejm\u00e9na u produkt\u016f p\u0159epravovan\u00fdch letadlem p\u0159es vysokohorsk\u00e9 pr\u016fsmyky. Tato zkou\u0161ka simuluje tlakov\u00e9 rozd\u00edly, ke kter\u00fdm doch\u00e1z\u00ed, kdy\u017e jsou obalov\u00e9 syst\u00e9my vystaveny vysok\u00fdm nadmo\u0159sk\u00fdm v\u00fd\u0161k\u00e1m, a zaji\u0161\u0165uje, \u017ee obal si zachov\u00e1 svou neporu\u0161enost a zabr\u00e1n\u00ed po\u0161kozen\u00ed b\u011bhem p\u0159epravy. Je to z\u00e1sadn\u00ed pro obalov\u00e9 syst\u00e9my v odv\u011btv\u00edch, jako je farmaceutick\u00fd pr\u016fmysl, potravin\u00e1\u0159stv\u00ed a elektronika, kde by selh\u00e1n\u00ed obalu mohlo ohrozit bezpe\u010dnost nebo kvalitu v\u00fdrobku.<\/p>\n<hr data-start=\"732\" data-end=\"735\" \/>\n<p data-start=\"737\" data-end=\"794\"><strong data-start=\"737\" data-end=\"794\">Ot\u00e1zka \u010d. 2: Jak funguje zkou\u0161ka t\u011bsnosti pomoc\u00ed vakua podle normy ASTM D6653?<\/strong><\/p>\n<p data-start=\"796\" data-end=\"1338\"><strong data-start=\"796\" data-end=\"803\">A2:<\/strong><br data-start=\"803\" data-end=\"806\" \/>Zkou\u0161ka t\u011bsnosti ve vakuu podle normy ASTM D6653 spo\u010d\u00edv\u00e1 v tom, \u017ee se zabalen\u00fd v\u00fdrobek vystav\u00ed simulovan\u00e9mu prost\u0159ed\u00ed ve vysok\u00e9 nadmo\u0159sk\u00e9 v\u00fd\u0161ce uvnit\u0159 vakuov\u00e9 komory. Sou\u010d\u00e1st\u00ed zkou\u0161ky je vytvo\u0159en\u00ed vakua v obalov\u00e9m syst\u00e9mu, \u010d\u00edm\u017e se simuluje tlakov\u00fd rozd\u00edl, kter\u00e9mu je v\u00fdrobek vystaven b\u011bhem leteck\u00e9 p\u0159epravy ve vysok\u00fdch nadmo\u0159sk\u00fdch v\u00fd\u0161k\u00e1ch. N\u00e1sledn\u011b se obal po vystaven\u00ed vakuu zkontroluje, zda nevykazuje zn\u00e1mky deformace, net\u011bsnosti nebo po\u0161kozen\u00ed. To pom\u00e1h\u00e1 ur\u010dit, zda obal dok\u00e1\u017ee odolat tlakov\u00fdm zm\u011bn\u00e1m, ani\u017e by byla ohro\u017eena jeho schopnost chr\u00e1nit v\u00fdrobek.<\/p>\n<hr data-start=\"1340\" data-end=\"1343\" \/>\n<p data-start=\"1345\" data-end=\"1433\"><strong data-start=\"1345\" data-end=\"1433\">Ot\u00e1zka 3: Jak\u00e9 jsou kl\u00ed\u010dov\u00e9 p\u0159\u00edstroje pot\u0159ebn\u00e9 k prov\u00e1d\u011bn\u00ed vakuov\u00fdch zkou\u0161ek t\u011bsnosti podle normy ASTM D6653?<\/strong><\/p>\n<p data-start=\"1435\" data-end=\"1523\"><strong data-start=\"1435\" data-end=\"1442\">A3:<\/strong><br data-start=\"1442\" data-end=\"1445\" \/>K proveden\u00ed zkou\u0161ek t\u011bsnosti ve vakuu podle normy ASTM D6653 je zapot\u0159eb\u00ed n\u00e1sleduj\u00edc\u00ed vybaven\u00ed:<\/p>\n<ol>\n<li data-start=\"1527\" data-end=\"1658\"><strong data-start=\"1527\" data-end=\"1546\">Vakuov\u00e1 komora:<\/strong> Komora schopn\u00e1 odolat tlakov\u00e9mu rozd\u00edlu p\u0159ibli\u017en\u011b jedn\u00e9 atmosf\u00e9ry, vybaven\u00e1 vakuov\u011b t\u011bsn\u00fdm krytem.<\/li>\n<li data-start=\"1662\" data-end=\"1783\"><strong data-start=\"1662\" data-end=\"1679\">Vakuometr:<\/strong> Vakuometr laboratorn\u00ed kvality s m\u011b\u0159ic\u00edm rozsahem od 0 do 100 kPa (0 a\u017e 30 palc\u016f Hg) a p\u0159esnost\u00ed \u00b12%.<\/li>\n<li data-start=\"1787\" data-end=\"1924\"><strong data-start=\"1787\" data-end=\"1817\">Zdroj vakua a \u0159\u00edzen\u00ed:<\/strong> Vstupn\u00ed a v\u00fdstupn\u00ed trubky, vybaven\u00e9 ru\u010dn\u011b ovl\u00e1dan\u00fdmi ventily, slou\u017e\u00edc\u00ed k \u0159\u00edzen\u00ed vytv\u00e1\u0159en\u00ed a uvol\u0148ov\u00e1n\u00ed vakua.<\/li>\n<li data-start=\"1925\" data-end=\"2035\">\n<p data-start=\"1928\" data-end=\"2035\"><strong data-start=\"1928\" data-end=\"1946\">Dr\u017e\u00e1k vzork\u016f:<\/strong> Dr\u017e\u00e1k dostate\u010dn\u011b velk\u00fd, aby pojmul zku\u0161ebn\u00ed vzorek a umo\u017enil jeho rozta\u017een\u00ed b\u011bhem zkou\u0161ky.<\/p>\n<\/li>\n<\/ol>\n<hr data-start=\"2037\" data-end=\"2040\" \/>\n<p data-start=\"2042\" data-end=\"2114\"><strong data-start=\"2042\" data-end=\"2114\">Ot\u00e1zka \u010d. 4: Jak dlouho by m\u011bla trvat zkou\u0161ka t\u011bsnosti pomoc\u00ed vakua podle normy ASTM D6653?<\/strong><\/p>\n<p data-start=\"2116\" data-end=\"2463\"><strong data-start=\"2116\" data-end=\"2123\">A4:<\/strong><br data-start=\"2123\" data-end=\"2126\" \/>Podle normy ASTM D6653 by m\u011bla zkou\u0161ka t\u011bsnosti ve vakuu trvat 60 minut, b\u011bhem nich\u017e je zku\u0161ebn\u00ed vzorek vystaven vakuov\u00e9mu tlaku odpov\u00eddaj\u00edc\u00edmu vysokohorsk\u00fdm podm\u00ednk\u00e1m (nap\u0159\u00edklad 16 000 stop \u00b1 5%). Tato doba umo\u017e\u0148uje dostate\u010dn\u011b simulovat podm\u00ednky, kter\u00fdm m\u016f\u017ee b\u00fdt obal vystaven b\u011bhem p\u0159epravy v oblastech s vysokou nadmo\u0159skou v\u00fd\u0161kou.<\/p>\n<hr data-start=\"2465\" data-end=\"2468\" \/>\n<p data-start=\"2470\" data-end=\"2556\"><strong data-start=\"2470\" data-end=\"2556\">Ot\u00e1zka \u010d. 5: Jak\u00e9 kl\u00ed\u010dov\u00e9 v\u00fdsledky je t\u0159eba sledovat po proveden\u00ed vakuov\u00e9 zkou\u0161ky t\u011bsnosti?<\/strong><\/p>\n<p data-start=\"2558\" data-end=\"2647\"><strong data-start=\"2558\" data-end=\"2565\">A5:<\/strong><br data-start=\"2565\" data-end=\"2568\" \/>Po proveden\u00ed vakuov\u00e9 zkou\u0161ky t\u011bsnosti je t\u0159eba zkontrolovat zejm\u00e9na n\u00e1sleduj\u00edc\u00ed v\u00fdsledky:<\/p>\n<ol>\n<li data-start=\"2651\" data-end=\"2802\"><strong data-start=\"2651\" data-end=\"2667\">Deformace:<\/strong> Zkontrolujte, zda se obal v d\u016fsledku zm\u011bn tlaku nezdeformoval. Obal, kter\u00fd se v\u00fdrazn\u011b roztahuje nebo m\u011bn\u00ed tvar, m\u016f\u017ee b\u00fdt po\u0161kozen.<\/li>\n<li data-start=\"2806\" data-end=\"2949\"><strong data-start=\"2806\" data-end=\"2818\">\u00danik:<\/strong> Zkontrolujte, zda na obalu nejsou patrn\u00e9 zn\u00e1mky \u00faniku, kter\u00e9 by nazna\u010dovaly, \u017ee nedo\u0161lo k zachov\u00e1n\u00ed neporu\u0161enosti uzav\u0159en\u00e9ho obalu.<\/li>\n<li data-start=\"2953\" data-end=\"3097\"><strong data-start=\"2953\" data-end=\"2978\">Konstruk\u010dn\u00ed integrita:<\/strong> Ujist\u011bte se, \u017ee v\u0161echny \u0161vy, uz\u00e1v\u011bry a sou\u010d\u00e1sti obalu z\u016fst\u00e1vaj\u00ed neporu\u0161en\u00e9 a nevykazuj\u00ed \u017e\u00e1dn\u00e9 viditeln\u00e9 praskliny ani po\u0161kozen\u00ed.<\/li>\n<\/ol>\n<p data-start=\"3099\" data-end=\"3224\">Pokud nejsou zji\u0161t\u011bna \u017e\u00e1dn\u00e1 v\u00fdznamn\u00e1 po\u0161kozen\u00ed ani \u00faniky, lze balic\u00ed syst\u00e9m pova\u017eovat za vhodn\u00fd pro p\u0159epravu ve vysok\u00fdch nadmo\u0159sk\u00fdch v\u00fd\u0161k\u00e1ch.<\/p>","protected":false},"excerpt":{"rendered":"<p>ASTM D6653 Vacuum Leak Test The ASTM D6653 standard outlines a method for testing the integrity of packaging systems exposed to high-altitude conditions. This test is crucial for determining how products and their packaging systems perform under pressure differentials encountered during transport, especially in feeder aircraft traveling over high mountain passes. The vacuum leak test &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/cs\/standards\/astm-d6653\/\"> <span class=\"screen-reader-text\">ASTM D6653<\/span> Pokra\u010dovat ve \u010dten\u00ed \"<\/a><\/p>","protected":false},"author":4,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7754","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages\/7754","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/comments?post=7754"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages\/7754\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/media?parent=7754"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}