{"id":7471,"date":"2025-09-17T10:39:11","date_gmt":"2025-09-17T02:39:11","guid":{"rendered":"https:\/\/www.qualitester.com\/?page_id=7471"},"modified":"2025-09-17T10:50:09","modified_gmt":"2025-09-17T02:50:09","slug":"astm-f2338","status":"publish","type":"page","link":"https:\/\/www.qualitester.com\/cs\/standards\/astm-f2338\/","title":{"rendered":"ASTM F2338"},"content":{"rendered":"<h1 style=\"text-align: center;\" data-start=\"245\" data-end=\"755\">ASTM F2338<br \/>\n<small>Metoda vakuov\u00e9ho rozpadu<\/small><\/h1>\n<p data-start=\"245\" data-end=\"755\">Integrita obalu m\u00e1 z\u00e1sadn\u00ed v\u00fdznam v odv\u011btv\u00edch, jako je farmaceutick\u00fd pr\u016fmysl, zdravotnick\u00e9 prost\u0159edky a potravin\u00e1\u0159stv\u00ed. I ten nejmen\u0161\u00ed \u00fanik m\u016f\u017ee ohrozit sterilitu, zkr\u00e1tit dobu trvanlivosti nebo v\u00e9st k selh\u00e1n\u00ed produktu. <a href=\"https:\/\/www.qualitester.com\/cs\/standards\/astm-f2338\/\"><strong data-start=\"439\" data-end=\"453\">ASTM F2338<\/strong><\/a> je celosv\u011btov\u011b uzn\u00e1van\u00e1 norma, kter\u00e1 stanovuje nedestruktivn\u00ed metodu detekce net\u011bsnost\u00ed v r\u016fzn\u00fdch obalov\u00fdch syst\u00e9mech.<\/p>\n<hr data-start=\"757\" data-end=\"760\" \/>\n<h2 data-start=\"762\" data-end=\"786\">Co je norma ASTM F2338?<\/h2>\n<p data-start=\"788\" data-end=\"1077\">ASTM F2338, jeho\u017e ofici\u00e1ln\u00ed n\u00e1zev zn\u00ed <em data-start=\"816\" data-end=\"911\">Standardn\u00ed zku\u0161ebn\u00ed metoda pro nedestruktivn\u00ed detekci net\u011bsnost\u00ed v obalech metodou poklesu vakua<\/em>, definuje p\u0159esn\u00fd a citliv\u00fd postup pro detekci net\u011bsnost\u00ed. Tato metoda spo\u010d\u00edv\u00e1 v vytvo\u0159en\u00ed \u0159\u00edzen\u00e9ho vakua kolem obalu a sledov\u00e1n\u00ed zm\u011bn tlaku ve zku\u0161ebn\u00ed komo\u0159e.<\/p>\n<p data-start=\"1079\" data-end=\"1233\">Pokud dojde k \u00faniku, plyny unikaj\u00ed z obalu do komory, co\u017e zp\u016fsobuje m\u011b\u0159iteln\u00fd <strong data-start=\"1166\" data-end=\"1182\">vakuov\u00fd rozpad<\/strong>. Tato technika je \u0161iroce vyu\u017e\u00edv\u00e1na, proto\u017ee:<\/p>\n<ul>\n<li data-start=\"1237\" data-end=\"1315\"><strong data-start=\"1237\" data-end=\"1255\">Nede\u0161truktivn\u00ed<\/strong> \u2013 bal\u00ed\u010dky z\u016fst\u00e1vaj\u00ed neporu\u0161en\u00e9 pro dal\u0161\u00ed pou\u017eit\u00ed nebo distribuci.<\/li>\n<li data-start=\"1318\" data-end=\"1397\"><strong data-start=\"1318\" data-end=\"1338\">Vysoce citliv\u00fd<\/strong> \u2013 schopn\u00fd odhalit \u00faniky, kter\u00e9 nejsou viditeln\u00e9 pouh\u00fdm okem.<\/li>\n<li data-start=\"1400\" data-end=\"1488\"><strong data-start=\"1400\" data-end=\"1436\">Vhodn\u00e9 pro mnoho typ\u016f balen\u00ed<\/strong> \u2013 pru\u017en\u00e9, tuh\u00e9, por\u00e9zn\u00ed a nepor\u00e9zn\u00ed konstrukce.<\/li>\n<li data-start=\"1491\" data-end=\"1575\"><strong data-start=\"1491\" data-end=\"1504\">\u00da\u010dinn\u00fd<\/strong> \u2013 vhodn\u00e9 jak pro laboratorn\u00ed v\u00fdzkum, tak pro odb\u011br vzork\u016f ve v\u00fdrobn\u00edm procesu.<\/li>\n<\/ul>\n<p data-start=\"1577\" data-end=\"1775\">Norma ASTM F2338 je obzvl\u00e1\u0161t\u011b d\u016fle\u017eit\u00e1 pro <strong data-start=\"1616\" data-end=\"1719\">farmaceutick\u00e9 blistrov\u00e9 obaly, steriln\u00ed zdravotnick\u00e9 prost\u0159edky, uzav\u0159en\u00e9 potravinov\u00e9 vani\u010dky a obaly na elektroniku<\/strong> kde je prevence \u00fanik\u016f z\u00e1sadn\u00ed pro bezpe\u010dnost v\u00fdrobku.<\/p>\n<hr data-start=\"1777\" data-end=\"1780\" \/>\n<h2 data-start=\"1782\" data-end=\"1824\">Porozum\u011bn\u00ed metod\u011b vakuov\u00e9ho rozpadu<\/h2>\n<p data-start=\"1826\" data-end=\"1904\">Na str\u00e1nk\u00e1ch <strong data-start=\"1830\" data-end=\"1853\">metoda vakuov\u00e9ho rozpadu<\/strong> je j\u00e1drem normy ASTM F2338. Tento proces zahrnuje:<\/p>\n<ol>\n<li data-start=\"1909\" data-end=\"1956\">Um\u00edst\u011bn\u00ed bal\u00edku do ut\u011bsn\u011bn\u00e9 zku\u0161ebn\u00ed komory.<\/li>\n<li data-start=\"1960\" data-end=\"2020\">Uplat\u0148ov\u00e1n\u00ed podtlaku a\u017e do dosa\u017een\u00ed stanoven\u00e9 hodnoty tlaku.<\/li>\n<li data-start=\"2024\" data-end=\"2071\">Odpojen\u00ed komory od zdroje vakua.<\/li>\n<li data-start=\"2075\" data-end=\"2140\">Sledov\u00e1n\u00ed stability tlaku pomoc\u00ed vysoce p\u0159esn\u00e9ho sn\u00edma\u010de.<\/li>\n<\/ol>\n<p data-start=\"2142\" data-end=\"2253\">N\u00e1r\u016fst tlaku nazna\u010duje, \u017ee vzduchem nebo parou doch\u00e1z\u00ed k \u00faniku p\u0159es net\u011bsnost. Citlivost zkou\u0161ky z\u00e1vis\u00ed na:<\/p>\n<ul>\n<li data-start=\"2257\" data-end=\"2287\">Konstrukce komory a t\u011bsnost<\/li>\n<li data-start=\"2290\" data-end=\"2320\">P\u0159esnost tlakov\u00e9ho sn\u00edma\u010de<\/li>\n<li data-start=\"2323\" data-end=\"2374\">Zku\u0161ebn\u00ed parametry, jako je \u00farove\u0148 vakua a doba trv\u00e1n\u00ed<\/li>\n<li data-start=\"2377\" data-end=\"2445\">Vlastnosti obalu (tuh\u00fd vs. pru\u017en\u00fd, por\u00e9zn\u00ed vs. nepor\u00e9zn\u00ed)<\/li>\n<\/ul>\n<p data-start=\"2447\" data-end=\"2566\">D\u00edky tomu je tato metoda univerz\u00e1ln\u011b pou\u017eiteln\u00e1 nap\u0159\u00ed\u010d r\u016fzn\u00fdmi odv\u011btv\u00edmi, proto\u017ee parametry lze p\u0159izp\u016fsobit konkr\u00e9tn\u00edm syst\u00e9m\u016fm v\u00fdrobk\u016f a obal\u016f.<\/p>\n<hr data-start=\"2568\" data-end=\"2571\" \/>\n<h2 data-start=\"2573\" data-end=\"2623\">Vyu\u017eit\u00ed p\u0159\u00edstroje pro m\u011b\u0159en\u00ed poklesu vakua v obalech<\/h2>\n<p><a href=\"https:\/\/www.qualitester.com\/cs\/produkt-2\/sale-non-destructive-leak-testing-equipment\/\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignleft wp-image-7474 size-medium\" src=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/09\/ASTM-F2338-Vacuum-Decay-Method-Packaging-Vacuum-Decay-Tester-300x300.webp\" alt=\"ASTM F2338 Metoda m\u011b\u0159en\u00ed \u00fabytku vakua \u2013 P\u0159\u00edstroj pro m\u011b\u0159en\u00ed \u00fabytku vakua v obalech\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/09\/ASTM-F2338-Vacuum-Decay-Method-Packaging-Vacuum-Decay-Tester-300x300.webp 300w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/09\/ASTM-F2338-Vacuum-Decay-Method-Packaging-Vacuum-Decay-Tester-150x150.webp 150w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/09\/ASTM-F2338-Vacuum-Decay-Method-Packaging-Vacuum-Decay-Tester-12x12.webp 12w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/09\/ASTM-F2338-Vacuum-Decay-Method-Packaging-Vacuum-Decay-Tester-100x100.webp 100w, https:\/\/www.qualitester.com\/wp-content\/uploads\/2025\/09\/ASTM-F2338-Vacuum-Decay-Method-Packaging-Vacuum-Decay-Tester.webp 600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p data-start=\"2625\" data-end=\"2739\">Pou\u017eit\u00ed <a href=\"https:\/\/www.qualitester.com\/cs\/produkt-2\/sale-non-destructive-leak-testing-equipment\/\"><strong data-start=\"2633\" data-end=\"2666\">p\u0159\u00edstroj pro m\u011b\u0159en\u00ed poklesu vakua v obalech<\/strong><\/a> zaji\u0161\u0165uje d\u016fv\u011bru v neporu\u0161enost v\u00fdrobku. Mezi b\u011b\u017en\u00e9 oblasti pou\u017eit\u00ed pat\u0159\u00ed:<\/p>\n<ul>\n<li data-start=\"2743\" data-end=\"2854\"><strong data-start=\"2743\" data-end=\"2783\">Obaly pro zdravotnictv\u00ed a farmaceutick\u00fd pr\u016fmysl<\/strong> \u2013 zaji\u0161t\u011bn\u00ed sterility injek\u010dn\u00edch st\u0159\u00edka\u010dek, lahvi\u010dek, blistrov\u00fdch balen\u00ed a infuzn\u00edch vak\u016f.<\/li>\n<li data-start=\"2857\" data-end=\"2975\"><strong data-start=\"2857\" data-end=\"2878\">J\u00eddlo a n\u00e1poje<\/strong> \u2013 zachov\u00e1n\u00ed \u010derstvosti a zabr\u00e1n\u011bn\u00ed mikrobi\u00e1ln\u00ed kontaminaci v t\u00e1ck\u00e1ch, s\u00e1\u010dc\u00edch a lahv\u00edch.<\/li>\n<li data-start=\"2978\" data-end=\"3098\"><strong data-start=\"2978\" data-end=\"3021\">Elektronika a v\u00fdrobky ka\u017edodenn\u00ed chemick\u00e9 pot\u0159eby<\/strong> \u2013 zabr\u00e1n\u011bn\u00ed vniknut\u00ed vlhkosti nebo plynu, kter\u00e9 by mohly m\u00edt vliv na citliv\u00e9 v\u00fdrobky.<\/li>\n<\/ul>\n<p data-start=\"3100\" data-end=\"3245\">Jeliko\u017e se jedn\u00e1 o nedestruktivn\u00ed metodu, mohou v\u00fdrobci prov\u00e1d\u011bt <strong data-start=\"3164\" data-end=\"3188\">In-line testov\u00e1n\u00ed 100%<\/strong> nebo statistick\u00e9 testov\u00e1n\u00ed \u0161ar\u017e\u00ed bez pl\u00fdtv\u00e1n\u00ed v\u00fdrobky.<\/p>\n<hr data-start=\"3247\" data-end=\"3250\" \/>\n<h2 data-start=\"3252\" data-end=\"3295\">Pro\u010d si vybrat p\u0159\u00edstroj Cell Instruments MLT-01<\/h2>\n<p data-start=\"3297\" data-end=\"3461\">Pro spole\u010dnosti, kter\u00e9 hledaj\u00ed spolehlivou detekci net\u011bsnost\u00ed podle normy ASTM F2338, je <strong data-start=\"3365\" data-end=\"3410\">Mikro\u00fanikov\u00fd tester Cell Instruments MLT-01<\/strong> je pokro\u010dil\u00e9 \u0159e\u0161en\u00ed. Mezi jeho hlavn\u00ed v\u00fdhody pat\u0159\u00ed:<\/p>\n<ul>\n<li data-start=\"3465\" data-end=\"3531\"><strong data-start=\"3465\" data-end=\"3485\">Vysok\u00e1 citlivost<\/strong> s rozli\u0161ovac\u00ed schopnost\u00ed v rozmez\u00ed 1\u20133 \u03bcm.<\/li>\n<li data-start=\"3534\" data-end=\"3601\"><strong data-start=\"3534\" data-end=\"3560\">Flexibiln\u00ed velikosti komor<\/strong> p\u0159izp\u016fsoben\u00e9 r\u016fzn\u00fdm form\u00e1m balen\u00ed.<\/li>\n<li data-start=\"3604\" data-end=\"3667\"><strong data-start=\"3604\" data-end=\"3629\">Rozhran\u00ed PLC a HMI<\/strong> pro p\u0159esn\u00e9 a u\u017eivatelsky p\u0159\u00edv\u011btiv\u00e9 ovl\u00e1d\u00e1n\u00ed.<\/li>\n<li data-start=\"3670\" data-end=\"3744\"><strong data-start=\"3670\" data-end=\"3697\">Efektivn\u00ed testovac\u00ed cyklus<\/strong> v\u010detn\u011b krok\u016f pln\u011bn\u00ed, usazov\u00e1n\u00ed a m\u011b\u0159en\u00ed.<\/li>\n<li data-start=\"3747\" data-end=\"3812\"><strong data-start=\"3747\" data-end=\"3782\">V\u00fdpo\u010det efektivn\u00ed m\u00edry \u00faniku<\/strong> pro p\u0159esnou anal\u00fdzu dat.<\/li>\n<\/ul>\n<p data-start=\"3814\" data-end=\"3965\">D\u00edky za\u010dlen\u011bn\u00ed za\u0159\u00edzen\u00ed MLT-01 do proces\u016f kontroly kvality mohou v\u00fdrobci v\u00fdrazn\u011b sn\u00ed\u017eit riziko, \u017ee se na trh dostanou vadn\u00e9 obaly.<\/p>\n<hr data-start=\"3967\" data-end=\"3970\" \/>\n<h2 data-start=\"3972\" data-end=\"4024\">V\u00fdznam normy ASTM F2338 v oblasti zaji\u0161t\u011bn\u00ed kvality<\/h2>\n<p data-start=\"4026\" data-end=\"4148\">Dodr\u017eov\u00e1n\u00ed normy ASTM F2338 zaru\u010duje, \u017ee obaly spl\u0148uj\u00ed p\u0159\u00edsn\u00e9 bezpe\u010dnostn\u00ed a regula\u010dn\u00ed po\u017eadavky. Mezi jej\u00ed v\u00fdhody pat\u0159\u00ed:<\/p>\n<ul>\n<li data-start=\"4152\" data-end=\"4226\"><strong data-start=\"4152\" data-end=\"4177\">Schv\u00e1len\u00ed regula\u010dn\u00edm org\u00e1nem<\/strong> \u2013 m\u00e1 d\u016fv\u011bru FDA, EMA a dal\u0161\u00edch sv\u011btov\u00fdch regula\u010dn\u00edch org\u00e1n\u016f.<\/li>\n<li data-start=\"4229\" data-end=\"4307\"><strong data-start=\"4229\" data-end=\"4257\">Zv\u00fd\u0161en\u00e1 bezpe\u010dnost spot\u0159ebitel\u016f<\/strong> \u2013 p\u0159edch\u00e1zen\u00ed kontaminaci a stahov\u00e1n\u00ed v\u00fdrobk\u016f z trhu.<\/li>\n<li data-start=\"4310\" data-end=\"4393\"><strong data-start=\"4310\" data-end=\"4326\">\u00daspory n\u00e1klad\u016f<\/strong> \u2013 sn\u00ed\u017een\u00ed mno\u017estv\u00ed odpadu a zabr\u00e1n\u011bn\u00ed vr\u00e1cen\u00ed zbo\u017e\u00ed v d\u016fsledku vad obal\u016f.<\/li>\n<li data-start=\"4396\" data-end=\"4494\"><strong data-start=\"4396\" data-end=\"4420\">Optimalizace proces\u016f<\/strong> \u2013 poskytuje informace o t\u011bsnic\u00edch vlastnostech a vhodnosti materi\u00e1l\u016f.<\/li>\n<\/ul>\n<p data-start=\"4496\" data-end=\"4675\">Stru\u010dn\u011b \u0159e\u010deno, p\u0159ijet\u00ed normy ASTM F2338 a vyu\u017eit\u00ed pokro\u010dil\u00fdch n\u00e1stroj\u016f, jako je MLT-01, umo\u017e\u0148uje firm\u00e1m pos\u00edlit jejich <strong data-start=\"4604\" data-end=\"4634\">programy zaji\u0161t\u011bn\u00ed kvality<\/strong> a z\u00e1rove\u0148 spl\u0148ovat mezin\u00e1rodn\u00ed normy.<\/p>\n<hr data-start=\"4677\" data-end=\"4680\" \/>\n<p data-start=\"4699\" data-end=\"5144\"><a href=\"https:\/\/www.astm.org\/f2338-09r20.html\" target=\"_blank\" rel=\"noopener nofollow\"><strong data-start=\"4699\" data-end=\"4713\">ASTM F2338<\/strong><\/a> stanovuje standard pro nedestruktivn\u00ed testov\u00e1n\u00ed t\u011bsnosti obal\u016f prost\u0159ednictv\u00edm <strong data-start=\"4785\" data-end=\"4808\">metoda vakuov\u00e9ho rozpadu<\/strong>. D\u00edky sv\u00e9 p\u0159esnosti a p\u0159izp\u016fsobivosti chr\u00e1n\u00ed v\u00fdrobky v odv\u011btv\u00edch, kde nelze slevit z bezpe\u010dnosti a spolehlivosti. Vyu\u017eit\u00edm <strong data-start=\"4949\" data-end=\"4982\">p\u0159\u00edstroj pro m\u011b\u0159en\u00ed poklesu vakua v obalech<\/strong> jako nap\u0159\u00edklad <strong data-start=\"4995\" data-end=\"5022\">Cell Instruments MLT-01<\/strong>, spole\u010dnosti tak z\u00edsk\u00e1vaj\u00ed \u00fa\u010dinn\u00fd n\u00e1stroj k detekci mikro\u00fanik\u016f, optimalizaci proces\u016f a zaji\u0161t\u011bn\u00ed souladu s glob\u00e1ln\u00edmi standardy.<\/p>\n<p data-start=\"5146\" data-end=\"5338\">Pro v\u00fdrobce obal\u016f, zdravotnick\u00fdch prost\u0159edk\u016f, l\u00e9\u010div a potravin nen\u00ed zaveden\u00ed zkou\u0161ek podle normy ASTM F2338 pouze osv\u011bd\u010den\u00fdm postupem \u2013 je to z\u00e1sadn\u00ed krok k zaji\u0161t\u011bn\u00ed kvality a d\u016fv\u011bry spot\u0159ebitel\u016f.<\/p>\n<h2 data-start=\"155\" data-end=\"192\">\u010casto kladen\u00e9 ot\u00e1zky (FAQ)<\/h2>\n<p data-start=\"194\" data-end=\"455\"><strong data-start=\"194\" data-end=\"229\">1. K \u010demu se norma ASTM F2338 pou\u017e\u00edv\u00e1?<\/strong><br data-start=\"229\" data-end=\"232\" \/>ASTM F2338 je metoda nedestruktivn\u00edho testov\u00e1n\u00ed pou\u017e\u00edvan\u00e1 k detekci net\u011bsnost\u00ed v obalech. Je \u0161iroce vyu\u017e\u00edv\u00e1na ve farmaceutick\u00e9m pr\u016fmyslu, v odv\u011btv\u00ed zdravotnick\u00fdch prost\u0159edk\u016f, potravin\u00e1\u0159stv\u00ed a elektronick\u00e9m pr\u016fmyslu k zaji\u0161t\u011bn\u00ed integrity v\u00fdrobk\u016f a dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f.<\/p>\n<p data-start=\"457\" data-end=\"703\"><strong data-start=\"457\" data-end=\"502\">2. Jak funguje metoda vakuov\u00e9ho rozpadu?<\/strong><br data-start=\"502\" data-end=\"505\" \/>P\u0159i metod\u011b m\u011b\u0159en\u00ed poklesu vakua se obal um\u00edst\u00ed do ut\u011bsn\u011bn\u00e9 zku\u0161ebn\u00ed komory, vytvo\u0159\u00ed se vakuum a n\u00e1sledn\u011b se sleduje tlak v komo\u0159e. Jak\u00fdkoli n\u00e1r\u016fst tlaku signalizuje \u00fanik plynu z obalu prost\u0159ednictv\u00edm net\u011bsnosti.<\/p>\n<p data-start=\"705\" data-end=\"934\"><strong data-start=\"705\" data-end=\"760\">3. Lze pomoc\u00ed normy ASTM F2338 odhalit net\u011bsnosti v por\u00e9zn\u00edch obalech?<\/strong><br data-start=\"760\" data-end=\"763\" \/>Ano, norma ASTM F2338 umo\u017e\u0148uje testovat obaly s por\u00e9zn\u00ed bari\u00e9rou, av\u0161ak por\u00e9zn\u00ed povrch mus\u00ed b\u00fdt zakryt\u00fd nebo zablokovan\u00fd, aby se zabr\u00e1nilo fale\u0161n\u00fdm sign\u00e1l\u016fm zp\u016fsoben\u00fdm migrac\u00ed plynu materi\u00e1lem.<\/p>\n<p data-start=\"936\" data-end=\"1222\"><strong data-start=\"936\" data-end=\"1013\">4. Pro\u010d se pro zkou\u0161ky podle normy ASTM F2338 doporu\u010duje p\u0159\u00edstroj Cell Instruments MLT-01?<\/strong><br data-start=\"1013\" data-end=\"1016\" \/>P\u0159\u00edstroj MLT-01 se vyzna\u010duje vysokou citlivost\u00ed (a\u017e 1\u20133 \u03bcm), komorami p\u0159izp\u016fsoben\u00fdmi na m\u00edru a p\u0159esn\u00fdm provozem \u0159\u00edzen\u00fdm programovateln\u00fdm logick\u00fdm kontrol\u00e9rem (PLC), d\u00edky \u010demu\u017e spolehliv\u011b detekuje i ty nejmen\u0161\u00ed \u00faniky a z\u00e1rove\u0148 spl\u0148uje normy ASTM F2338.<\/p>","protected":false},"excerpt":{"rendered":"<p>ASTM F2338 Vacuum Decay Method Packaging integrity is critical in industries such as pharmaceuticals, medical devices, and food. Even the smallest leak can compromise sterility, reduce shelf life, or lead to product failure. ASTM F2338 is the globally recognized standard that provides a nondestructive method for detecting leaks in various packaging systems. What Is ASTM &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/www.qualitester.com\/cs\/standards\/astm-f2338\/\"> <span class=\"screen-reader-text\">ASTM F2338<\/span> Pokra\u010dovat ve \u010dten\u00ed \"<\/a><\/p>","protected":false},"author":4,"featured_media":0,"parent":4948,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"class_list":["post-7471","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages\/7471","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/comments?post=7471"}],"version-history":[{"count":0,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages\/7471\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/pages\/4948"}],"wp:attachment":[{"href":"https:\/\/www.qualitester.com\/cs\/wp-json\/wp\/v2\/media?parent=7471"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}